 共查询到18条相似文献,搜索用时 187 毫秒
1.
目的 探讨能谱成像技术(GSI)减少金属伪影的价值.方法 选取离体附肉猪腰椎骨模型1具,在相同CT剂量指数(CTDI)条件下分别行GSI和常规120kVp扫描;随后于L2、L4水平植入钛钉并行重复扫描.金属植入前后的GSI图像均以间距为10 keV在40~140 keV间重建11种单能量(Mono)+金属伪影消除技术(MARs)图像.主观评定钛钉植入后120kVp组和GSI组图像质量差异,并量化分析:(1)在金属伪影最重层面自金属边缘由近及远选取3个面积相同的ROI,依次记为ROI近、ROI中、ROI远,分别测量植入前120kVp和Mono组、植入后120 kVp、Mono+MARs组的CT值及CT标准差(SD)值,并采用LSD检验和Bonferroni检验比较3个ROI植入前Mono组和植入后Mono+MARs组CT值的差异.(2)计算对比噪声比(CNR)和伪影指数(AI);比较不同组金属植入前后的CT值、SD值和CNR值;通过伪影指数确定观察金属伪影的最佳keV范围.结果 (1)GSI组图像质量优于常规120kVp组.(2)伪影指数最小的keV范围是80~100 keV.(3)ROI近的植入前Mono组和植入后Mono+MARs组CT值分别为(80.25±16.00)和(30.10±10.45)HU,差异有统计学意义(Z=2.978,P<0.05);ROI中和ROI远的植入前Mono组、植入后Mono+MARs组CT值分别为(63.21±6.61)和(54.84±10.60)HU、(76.54±9.07)和(73.20±5.39)HU,差异均无统计学意义(t值分别为0.530、0.822,P值均>0.05).结论 能谱成像技术能准确校正距离金属3 cm范围外的伪影,并提供准确的CT值.  相似文献   

2.
目的:探讨宝石CT能谱成像(GSI)在减除脊柱金属植入物伪影的应用价值;同时研究应用能谱曲线寻找最佳keV值的可行性。方法:对6例脊柱金属植入术患者行宝石CT GSI扫描,并以10keV为间隔重建11组单能量(Mono)图像质量的客观指标。通过比较140kVp(QC)和各级别Mono图像的客观指标伪影指数(AI)和对比噪声比(CNR)、软组织和骨质以及金属植入物图像质量的主观评分(4分法,1分图像最优,4分图像最差),寻找GSI去金属伪影最佳成像条件。并以最佳图像为对照,比较利用能谱曲线寻得最佳Mono图像的质量和诊断效能。结果:AI在90~140keV时减低,在100~130keV达最低;CNR在100~120keV时减低且最低。能谱成像技术在90~140keV对软组织、骨质及金属植入物诊断效能提高,在110~130keV对软组织观察最优,在110~140keV对骨质及植入金属观察最优。利用能谱曲线寻得最佳单能量成像条件为100~120keV,范围落在普通方法确定的电压值区间内,其图像均能满足诊断。结论:宝石能谱CT GSI在高电压区可有效减除脊柱金属植入物伪影,最佳成像区间为100~120keV。利用能谱曲线可快速有效获得最佳单能量成像。  相似文献   

3.
目的:研究宝石CT能谱扫描在减少金属伪影方面的临床价值。方法:对31例体内含有金属植入物的受检者行能谱扫描(Gemstone spectral imaging,GSI),扫描后获得混合能量图像(140kVp),用能谱分析软件(GSI Viewer)进行分析,以10keV为间距在40~140keV间进行11种不同能量的单能量图像重建,选取最优单能量图像,再行金属伪影消除重建(Metal-Artifacts Reduction System,MARs),对混合能量图像及能谱图像(110keV单能量图像或单能量+MARs图像)进行感兴趣区(ROI)SD值的测定,计算出伪影的SD值。并且所有图像均由三位有经验的放射医师采用盲法进行独立评分,按金属伪影对图像质量的影响程度予以记3、2、1、0分(3分为基本无伪影;2分为图像质量较好,有部分伪影;1分为图像伪影较重,尚能观察;0分为伪影很重,图像无法观察)。对所获数据采用SPSS 17.0进行配对t检验分析。结果:在110keV单能量区图像信噪比较高,因此所有图像均于110keV行MARs重建。能谱图像(110keV单能量图像或单能量+MARs图像)的评分与混合能量图像的评分之间,以及能谱图像组与混合能量图像组金属伪影的SD值之间均存在显著性差异(P=0.000〈0.05),即能量图像的金属伪影明显降低,图像质量优于混合能量的图像质量。结论:宝石CT能谱扫描能显著减少受检部位的金属伪影与硬化伪影,使含金属植入物的受检部位CT图像质量明显提高,具有较高的临床价值。  相似文献   

4.
目的 评价能谱CT单能量成像(MONO)联合金属伪影去除软件(MARs)技术在去除颅内弹簧圈植入物伪影的临床应用价值.方法 选取15例头部弹簧圈介入术后患者,对其头部进行能谱成像(GSI)扫描,得到1组120 kVp混合能量(QC)图像、40 ~140 keV以10 keV为间隔的共11组MONO图像和11组MONO联合MARs图像.每组图像随机选择1个伪影较严重和1个无伪影的感兴趣区域(ROI),并测量出各自的SD值,并计算出各自伪影指数(AI),对SD值进行配对t检验,并对各自图像进行主观评分(0~3分).结果 120 kVp的QC图像、40~ 140 keV的11组MONO图像和11组MONO联合MARs图像,在60 ~140 keV范围内AI值表现为MONO联合MARs图像低于MONO图像,MONO图像低于QC图像,且MONO图像和MONO联合MARs图像在70 keV达到最低,往后AI值趋于平缓;三组图像的SD值配对t检验中,MONO图像中60 ~ 140 keV与QC图像无显著性差异(P>0.05),在MONO联合MARs图像中50 keV与QC无显著性差异(P=0.985,>0.05),而60 ~140 keV存在显著性差异且SD值均值小于QC均值,即MONO联合MARs图像中的60~140 keV组图像噪声明显低于其他组;在主观评价三组图像的配对t检验中,均存在显著性差异(P<0.05),并且MONO联合MARs图像的70 ~ 90 keV能量范围分别获得(2.85±0.15)、(2.78±0.18)和(2.75 ±0.20)分,远高于其他组.结论 在能谱CT中,MONO联合MARs在70 ~90 keV范围内去除颅内弹簧圈植入物伪影效果最为显著,其中70 keV是临床应用的最佳能量图像.  相似文献   

5.
目的 探讨Flash双能量CT单能谱成像技术去除颅内金属伪影用于颅内动脉瘤术后的临床应用价值.方法 对40例颅内动脉瘤术后复查的患者使用Flash双源CT双能量扫描,并以10 keV为间隔重组16组单能量图像.通过比较混合组和各keV组图像的客观指标伪影指数(AI)、对比噪声比(CNR)以及主观图像质量评分(4分法),寻找单能谱去金属伪影最佳的keV.结果 AI在120 keV时达最小,CNR在90 keV时最大,120 keV之后的单能谱图像的主观评分之间无明显差异.利用单能谱软件获得最佳单能量成像条件为90~ 120 keV,其图像均能满足诊断.结论 双能量单能谱成像技术能够有效去除金属伪影,清晰显示颅内动脉瘤术后的细微结构.  相似文献   

6.
刘卓  魏拓  洪楠  陈雷  张卓璐 《放射学实践》2019,34(3):332-336
【摘要】目的:通过体模研究,评价双能量CT扫描获得的虚拟单色谱图像(VMS)联合金属伪影削减(MAR)算法抑制股骨柄假体金属伪影的效果。方法:将人工股骨柄假体用细绳悬挂在水箱中心。以不同管电压(80、100、120、140kVp)单能量CT(SECT)及不同管电流(200、484mA)下的双能量CT(DECT)扫描假体。扫描设备选择单球管,单层探测器CT扫描仪。利用单球管双电压快速切换的双能量扫描获得的数据重建40、90、140keV单色谱图像(VMS),及经过金属伪影抑制算法处理的40、90、140keV单色谱图像(VMS+MAR)。对全部图像(16组)进行质量评价,包括伪影面积(AA),伪影指数(AI)。结果:16组图像(140kVp、120kVp、100kVp、80kVp、40keV 485mA、40keV 485mA MAR、90keV 485mA、90keV 485mA MAR、140keV 485mA、140keV 485mA MAR、40keV 200mA、40keV 200mA MAR、90keV 200mA、90keV 200mA MAR、140keV 200mA、140keV 200mA MAR)伪影面积分别为787、1088、1499、2133、5664、650、665、172、279、157、7603、886、803、238、423、172mm2,伪影指数分别为22.75、33.65、58.58、92.55、195.18、3.53、23.38、0.35、7.88、0.05、230.28、4.95、24.83、1.43、10.98、0.10HU。对于单能量扫描,随着管电压的降低,伪影逐步加重。对于双能量扫描单色谱图像,管电流越低伪影越严重;光子能量越低伪影越严重。经过金属伪影削减算法处理的单能量图像,金属伪影明显减轻。结论:与单能量扫描相比,双能量CT扫描高光子能量单色谱图像联合MAR算法能有效抑制股骨柄假体金属伪影。光子能量越高,金属伪影越小。  相似文献   

7.
目的:探讨双能量CT虚拟单能量重建技术对肝癌经导管动脉化疗栓塞(TACE)术后碘油沉积的临床诊断价值。方法:对11例肝癌TACE术后患者进行双能量腹部CT平扫。在100 kVp、140 kVp、线性融合图像(M=0.5)和以9组虚拟单能量(40、60、80、100、120、140、160、180和190 keV)图像上,在碘油沉积最显著的层面,测量伪影区及正常肝实质区的CT值,计算图像噪声(SD)和伪影指数(AI)。对伪影大小、图像噪声、碘油形态及综合图像质量分别进行主观评分。结果:客观评估:80 keV 图像的AI 值最小;线性融合图像、80 keV 图像的噪声最小。主观评估:在140 kVp、100~190 keV图像上伪影较少;线性融合图像和80 keV 图像的噪声评分最小;碘油形态以140 kVp、线性融合图像、80及100 keV图像上显示较为清晰。整体综合评分以线性融合图像和80 keV图像最高。结论:双能量CT 虚拟单能量重建技术在肝癌TACE术后碘油沉积的显示中,可以改善图像质量,以80 keV的虚拟单能量重建图像为最佳。  相似文献   

8.
目的研究能谱成像技术(gemstone spectral imaging,GSI)和多种伪影去除系统(multi artifact reductionsystem,MARS)在减除脊柱金属植入物椎管内伪影方面的临床价值,获得图像质量最佳的单能量图像。方法选取本院15例脊柱金属植入物患者,行能谱CT的GSI扫描及单能量加MARS技术重组,每隔10 keV分别获得40~140 keV共11组单能量图像及11组单能量加MARS图像,每组图像分别选取伪影最重层面(A)和无伪影层面(B)的两幅图像,行感兴趣区(ROI)与邻近脂肪组织CT值和噪声(SD)值的测定,分别记录为CT1、CT2和SD1、SD2,计算对比噪声比(contrast noise ratio,CNR)值,SD值比较采用配对资料t检验。结果 40~140 keV 11组单能量图像中,110 keV单能量图像组,A、B两层面SD值分别为54.12±8.35和34.77±3.50,两者之间差异没有统计学意义(t=2.32,P>0.05),其他10组P值均<0.05,两者差异有统计学意义;40~140 keV 11组单能量加MARS图像中,各组A、B两层面SD值之间差异有统计学意义(P<0.05),不同keV单能量图像中,GSI能谱成像的70 keV图像脊柱椎管内组织与邻近脂肪组织CNR最佳(CNR=9.2±5.07);110 keV+MARS的图像金属植入物伪影有不同程度的消除,但产生一定的图像失真。结论 110 keV单能量图像在减除脊柱金属植入物椎管内伪影方面的效果最佳,110 keV单能量图像优于110 keV+MARS图像,70 keV图像虽然CNR最佳,但噪声明显高于110 keV图像,不利于临床诊断。  相似文献   

9.
目的:寻找CT能谱成像的最佳能量点以减少肺部增强CT扫描锁骨下腋静脉和锁骨下静脉对比剂伪影,并改善图像质量。方法:共66名病人接受能谱CT扫描。一次能谱成像获得12组图像:140kVp混合能量图像和11组单能量图像(40~140keV)。比较混合能量和单能量图像在肺部增强CT动脉期的伪影区噪声、信噪比(SNR)、对比噪声比(CNR)和平均线束硬化伪影指数(BHAs)。BHAs是感兴趣区和背景区噪声平方差的平方根。结果:与常规混合能量组相比,120keV可最大程度地减少硬化伪影(P=0.000),同时SNR、CNR明显减小,导致软组织对比度明显减低。70keV可以减小硬化伪影(P=0.042),且SNR、CNR最高,优于混合能量图像和其他单能量图像,而伪影区噪声减低,图像质量最好。结论:在肺部增强扫描中,120keV去除对比剂硬化伪影的能力优于混合能量图像及其他单能量图像,但是组织对比度较差,可以结合70keV图像共同进行诊断。  相似文献   

10.
目的 探讨宝石能谱CT在儿童脊柱侧弯术后CT影像中去除金属植入物伪影的临床价值.方法 对8例行CT复查的脊柱侧弯术后患者行能谱CT扫描,采用GSI扫描模式,扫描后获得140 kVp混合能量图像(QC)及不同能量的单能量图像(MONO),同时使用单能金属伪影消除重建(MARs)技术对能谱数据进行去金属伪影获得图像(MONO+ MARs,共3组).8例共选取10个带有金属植入物的部位,再对每个部位选取2个伪影最大的层面(10个部位共计20层面)及1个伪影最小层面(作为背景)进行感兴趣区(ROI)客观噪声值(SD)的测定.每个层面选取2个ROI(椎管外软组织和椎管内软组织),由一位有经验的放射科医师独立评估图像质量并分别在工作站测量其SD值、计算伪影指数(AI).对所获数据采用SPSS 13.0进行统计学处理.使用非参数Wilcoxon秩和检验法进行组间差异统计学分析.结果 MONO组和MONO+ MARs组图像质量随着keV的升高明显改善.在120 ~140 keV水平可获得最小SD值及AI.对于椎管外组的SD值及AI值,MONO组SD值最低,QC组最高,两者之间差异有统计学意义(P<0.05),QC组及MONO+ MARs组两者差异无统计学意义(P>0.05).椎管内组的SD值及AI值,MONO+MARs组最低,QC组最高,两者之间差异有统计学意义(P<0.05),QC组与MONO组比较差异亦有统计学意义(P<0.05),MONO组与MONO+MARs组比较差异无统计学意义(P>0.05).结论 宝石能谱CT扫描及MARs后重建技术能显著改善儿童脊柱侧弯术后CT图像质量.对于椎管外软组织金属植入物伪影的去除,MONO组图像表现较突出;对于椎管内软组织的观察,MONO+ MARs组及MONO组图像质量均好于QC组,其中MONO+ MARs组图像质量略胜于MONO组.  相似文献   

11.

Purpose

To evaluate the effectiveness of spectral CT in reducing metal artifacts caused by pedicle screws in patients with scoliosis.

Materials and methods

Institutional review committee approval and written informed consents from patients were obtained. 18 scoliotic patients with a total of 228 pedicle screws who underwent spectral CT imaging were included in this study. Monochromatic image sets with and without the additional metal artifacts reduction software (MARS) correction were generated with photon energy at 65 keV and from 70 to 140 keV with 10 keV interval using the 80 kVp and 140 kVp projection sets. Polychromatic images corresponded to the conventional 140 kVp imaging were also generated from the same scan data as a control group. Both objective evaluation (screw width and quantitative artifacts index measurements) and subjective evaluation (depiction of pedicle screws, surrounding structures and their relationship) were performed.

Results

Image quality of monochromatic images in the range from 110 to 140 keV (0.97 ± 0.28) was rated superior to the conventional polychromatic images (2.53 ± 0.54) and also better than monochromatic images with lower energy. Images of energy above 100 keV also give accurate measurement of the width of screws and relatively low artifacts index. The form of screws was slightly distorted in MARS reconstruction.

Conclusions

Compared to conventional polychromatic images, monochromatic images acquired from dual-energy CT provided superior image quality with much reduced metal artifacts of pedicle screws in patients with scoliosis. Optimal energy range was found between 110 and 140 keV.  相似文献   

12.
PURPOSE: The purpose of this work was to use an extended CT scale technique (ECTS) to reduce artifacts due to metal implants and to optimize CT imaging parameters for metal implants using an experimental model. METHOD: Osteotomies were performed in 20 porcine femur specimens. One hundred cobalt-base screws and 24 steel plates were used for osteosynthesis in these specimens. Artificial lesions were produced in 50 screws, such as osteolysis near the screws (mimicking lysis due to infection, tumor, or loosening), displacement of the screws, as well as fractures of the screws. All specimens were examined using eight different CT protocols: four conventional (CCT) and four spiral (SCT) CT protocols with different milliampere-second values (130 and 480 mAs for CCT, 130 and 300 mAs for SCT), kilovolt potentials (120 and 140 kVp), and slice thicknesses (2 and 5 mm). The images were analyzed by three observers using a standard window (maximum window width 4,000 HU) and ECTS (maximum window width 40,000 HU). Receiver operating characteristic analysis was performed, and image quality was assessed according to a five level scale. RESULTS: Metal artifacts were significantly reduced using ECTS (p < 0.05). The highest diagnostic performance was obtained using ECTS with the thinnest slice thickness. Metal artifacts were more pronounced using SCT. In this experimental model, exposure dose and kilovolt potential had no significant impact on diagnostic performance (p > 0.05). CONCLUSION: ECTS improved imaging of metal implants. In this study, no significant effects of exposure dose and kilovolt potential were noted. Metal artifacts were more prominent using SCT than using CCT.  相似文献   

13.
目的探讨应用能谱CT最佳单能量成像联合ASIR及ASIR-V重建技术对胸部CT增强扫描动脉期图像质量的优化。方法搜集行胸部增强能谱CT检查的62例患者资料,使用能谱GSI模式进行扫描并重建,在传统重建模式(FBP)重建下,以间隔10 keV为一组重建出40~140 keV的11组单能量(MONO)图像,与140 kVp混合能量(QC)图像共组成12组图像。对12组图像的CNR、BHA采用单因素方差分析进行统计,并采用秩和检验分析其主观评分。得出能谱CT成像中伪影较小且图像质量较高的单能量图像。将其单能量图像分别与30%、50%、70%水平的ASIR及ASIR-V进行重建,得到6组新重建模式下的单能量图像,将其与FBP重建下QC及此单能量图像共组成8组图像并使用较前相同的统计学方法对其主观及客观评价进行分析比较。结果在FBP重建下,80 keV图像的CNR值为7.7±2.0,与QC图像无统计学差异(P>0.05);血管处的BHA值为44.4±22.0,低于QC图像(P<0.05);图像质量主观评分为4.50±0.62,与QC图像无差异(P>0.05);伪影主观评分为2.45±0.62,低于QC图像(P<0.05);具有较低的伪影水平并保持了较好的图像质量。因此选取80 keV做为最佳单能量值进行下一步研究。80 keV联合50%ASIR-V的CNR值为13.9±4.3,高于QC图像(P<0.05);BHA值与其他组差异无统计学意义;图像质量主观评分为4.90±0.298,高于其他组(P<0.05)。结论与常规胸部增强扫描动脉期图像相比,能谱CT 80 keV单能量联合50%ASIR-V图像能够减低对比剂硬化伪影,同时提高图像质量,可常规应用于胸部CT增强扫描。  相似文献   

14.
目的 探讨能谱CT在体外区分肾结石成分的价值.方法 168枚经外科手术取出的肾结石,分别置于猪肾中.行能谱扫描( GSI)及常规120 kVp扫描.测量计算GSI图像上结石的有效原子序数(Zeff)、钙水比值(CWR)、能谱衰减曲线斜率、50 keV单能量CT值及120 kVp混合能量CT值,并采用方差分析或秩和检验比较各组结石上述指标的差异.分别采用红外光谱分析仪测定其成分,成分单一的结石108枚,其中尿酸类结石组13枚、鸟粪石结石组24枚、胱氨酸结石组14枚、磷酸钙结石组18枚、草酸钙结石组39枚.结果 5组结石的Zeff、CWR、50 keV单能量CT值、120 kVp混合能量CT值及能谱衰减曲线斜率分别为:尿酸类结石组为7.4±0.4、0.0085±0.0021、(503±168) HU、(495±106) HU、-0.77、鸟粪石结石组为11.8±0.9、0.1743±0.0677、(1056±290) HU、(799±165) HU、18.72,胱氨酸结石组为11.2±0.6、0.1253±0.0297、(740±172)HU、(565±129) HU、12.79,磷酸钙结石组为16.0±0.4、0.6781±0.0952、(2567±178) HU、(1602±200) HU、37.14,草酸钙结石组为15.4 ±0.4、0.5683±0.0759、( 2267±385) HU、( 1489±284) HU、36.36,组间差异均有统计学意义(P值均<0.01).组内两两比较,有效原子序数、钙水比值及50 keV单能量CT值差异均有统计学意义(P值均<0.05).结论 能谱CT成像为区分肾结石成分提供了新的方法,有效原子序数、钙水比值及50 keV单能量CT值,3个指标均可以明显区分尿酸类、鸟粪石类、胱氨酸、磷酸钙类及草酸钙类结石.  相似文献   

15.
钱玲玲  李真林  袁元  王紫薇   《放射学实践》2013,(12):1216-1219
目的:探讨双源CT单能谱成像技术减少脊柱金属内固定器伪影的可能性。方法:31例后路脊柱金属内固定植入术后复查患者行双源CT双能量扫描,获得100、140和120kV图像。其中颈椎9例,胸椎7例,腰椎l5例。扫描数据采用双能量软件内的单能谱技术(Monoenergetic)处理,每例患者数据分别重建成64、69、88、105keV共4组图像以及主观目测图像质量最好的keV图像。由2位有经验的放射诊断医师分别对上述4组图像和主观目测最佳keV(OPT-keV)图像,以及平均加权120kV等图像共6组图像按照4分法进行图像质量评分。采用Kruskal—wallis检验分别对上述各组不同keV图像的质量进行统计学分析;采用Kappa检验评价2位医师评分的一致性。结果:单能谱最佳图像评分在3分及以上者27例,平均加权120kV图像3分及以上者仅3例,两者之间差异有统计学意义(F=118.139,P〈0.01)。金属固定器CT值在不同脊柱节段问存在统计学差异(P〈0.01);与120kV图像相比,较高单能谱值组(105keV组)图像质量改善明显(V=0.62,P〈0.001);脊柱金属内固定成像最佳单能谱值为123~144keV。结论:双能量CT单能谱技术能够有效减少脊柱内固定器金属伪影,明显改善脊柱金属内固定术后的CT图像质量,此外还可根据脊柱金属内固定所在不同脊柱节段,采用个性化的单能谱值进行后处理,使图像质量进一步提高。  相似文献   

16.
目的 评估CT能谱成像在胰腺癌病灶显示中的价值.方法 选取本院行CT能谱检查,且病理证实为胰腺导管腺癌的113例患者.CT扫描期相分平扫、动脉晚期(AP)、门脉期(PP);增强采用能谱扫描(GSI)模式.将感兴趣区(ROI)分别放置于病灶和胰腺实质处,重复测量3次,求得3次的平均值,计算病灶及胰腺实质AP和PP 40~140 keV的单能量CT值(CTmono值)、归一化CTmono值(以胰腺实质为标准)、对比噪声比(CNR)值及最佳单能量keV值,比较胰腺癌与胰腺组织间的差异,并将最佳单能量与70 keV单能量(相当于常规CT 120 kVp能量水平)进行比较.统计方法为配对t检验和符号秩和检验.结果 胰腺导管腺癌在AP及PP的最佳单能量为40 keV,AP和PP的最佳CNR平均值为2.31±1.02和2.38±1.02,70 keV CNR值为2.08±0.98和2.12±0.96,2期最佳CNR值均高于70 keV的CNR值.胰腺癌在70 keV时AP和PP的CTmono值分别为(58±13) HU和(71±19) HU,PP高于AP,40 keV 时AP和PP的CTmono值分别为(111±44) HU和(155±57) HU;胰腺癌在40 keV 时AP和 PP的归一化CTmono值的中位数分别为47.0%和53.9%,70 keV时分别为57.7%和61.8%,40 keV归一化CTmono值低于70 keV,有显著性差异.结论 CT能谱成像显示胰腺癌为相对乏血供、进行性强化的病灶;最佳单能量成像能够提高胰腺癌病灶的显示效果.  相似文献   

17.
CT能谱成像在诊断肿瘤淋巴结转移和肿瘤性质中的作用   总被引:1,自引:0,他引:1  
目的 通过对淋巴瘤、肺腺癌、肺鳞癌及胆管癌的转移性淋巴结行能谱CT扫描,探讨能谱成像在鉴别不同肿瘤淋巴结转移性肿大中的应用价值.方法 回顾性分析2010年10月至12月间淋巴瘤3例(28个淋巴结)、肺腺癌5例(30个淋巴结)、肺鳞癌4例(24个淋巴结)及胆管癌2例(10个淋巴结)行能谱CT扫描,测量混合能量图像上各个淋巴结在不同能量水平下(40~140 keV,间隔10 keV)淋巴结的CT值及碘基图和水基图各个淋巴结的碘和水含量,分别对不同肿瘤转移性淋巴结在不同keV下淋巴结的CT值、碘和水含量进行方差分析和t检验.结果 观察肿大转移淋巴结的最佳对比噪声比对应的单能量水平是70 keV.70 keV下淋巴瘤、肺腺癌、肺鳞癌及胆管癌CT值分别(81.36±9.81)、(58.33±21.55)、(56.47±10.62)和(73.57±4.43)HU差异有统计学意义(F=17.29,P<0.01),其中淋巴瘤与肺腺癌、肺鳞癌及肺鳞癌与胆管癌在CT值之间差异有统计学意义(P<0.05),淋巴瘤与胆管癌及肺腺癌与胆管癌CT值差异有统计学意义(P<0.05),肺腺癌与肺鳞癌CT值的差异未见统计学意义(P>0.05).淋巴瘤、肺腺癌、肺鳞癌及胆管癌的碘含量分别为(1.93±0.05)、(1.16±0.15)、(1.25±0.21)和(1.44±0.04)g/L;淋巴瘤、肺腺癌、肺鳞癌及胆管癌的水含量分别为(1029.40±20.85)、(1024.98±11.19)、(1022.12±12.94)和(1030.87±10.10)g/L;肺腺癌与肺鳞癌的转移性淋巴结的碘含量之间差异未见统计学意义(t=1.77,P>0.05),其他不同肿瘤转移性淋巴结的碘含量之间有统计学意义(P均<0.05);各不同肿瘤转移性淋巴结的水含量之间未见统计学意义(P均>0.05).结论 CT能谱成像通过应用碘含量及低能量下的CT值,对不同来源的转移性淋巴结的鉴别有较大意义,70 keV单能量图像显示肿大转移性淋巴结最清楚.  相似文献   

18.
潘雪琳  李真林  程巍  袁元   《放射学实践》2013,(12):1212-1215
目的:探讨颅内动脉瘤夹植入术后,双源CT头部血管双能量成像中单能谱成像技术在降低伪影方面的临床应用价值,寻求图像质量最佳的单能量成像点。方法:对48例颅内动脉瘤颈夹闭术后患者行双能量头部血管扫描,获得双能量扫描数据后,采用双能量软件内的单能谱技术(Monoenergetic)进行后处理。对40~120keV的单能量数据每隔10keV进行重建,共9组单能量图像,对每组图像选取4个点(a^d)进行CT值测量。a点位于动脉瘤夹伪影最重的脑组织即动脉瘤夹长轴的尾部;b点为a点的对称点,位于无动脉瘤夹伪影的脑组织内;c点位于受动脉瘤夹伪影影响最重的血管;d点为c点的对称点,位于无动脉瘤夹伪影影响的血管内。测量CT值分别记录为CTa、CTb、CTc、CTd,计算a、b两点CT值的差值即|CTa-CTb|以及c、d两点CT值的差值即|CTc-CTd|。采用配对t检验比较CTa、CTb之间,CTc、CTd之间,以及|CTa-CTb|、|CTc-CTd|的差异。结果:9组单能量图像上,a与b点、c与d点的CT值差异均有统计学意义(P<0.05);|CTa-CTb|和|CTc-CTd|在9组单能量图像间差异均有统计学意义(P<0.05)。随能量的升高|CTa-CTb|逐渐降低,而|CTc-CTd|除70keV组(为最低)外呈逐渐增加,其中40keV组|CTa-CTb|和|CTc-CTd|分别为(270.54±9.08)和(9.64±2.46)HU,70keV组|CTa-CTb|和|CTc-CTd|分别为(65.85±1.99)和(1.03±0.24)HU,120keV组|CTa-CTb|和|CTc-CTd|分别为(10.51±2.79)和(8.32±0.84)HU。结论:颅内动脉瘤夹闭术后患者复查头部血管增强扫描,CT单能谱成像技术可明显降低颅内动脉瘤夹的伪影,采用70keV进行图像重建可获得较好的图像质量。  相似文献   