首页 | 官方网站   微博 | 高级检索  
相似文献
 共查询到17条相似文献,搜索用时 567 毫秒
1.
目的:观察和比较非球面型人工晶状体及球面型人工晶状体植入术后对波阵面像差、对比敏感度的影响.方法:连续收集接受白内障超声乳化人工晶状体植入手术,术后随访时间大于3个月,最佳矫正视力≥0.8的患者53例,72只眼,其中植入非球面型人工晶状体(Tecnis Z9001,AMO)25例(38只眼),男10例,女15例,平均年龄(69.92±8.24)岁;植入球面型人工晶状体(Sensar AR40e,AMO)28例(34只眼),男12例,女16例,平均年龄(67.08±6.91)岁.在术后3个月时进行裸眼视力、最佳矫正视力、眼压、裂隙灯眼前节、眼底等一般检查,并应用客观波阵面像差仪(Wavelight Laser Technologic AG,德国)检查客观像差,应用德国罗兰对比敏感度仪(ROLAND BA-4 Contrastometer,德国)进行暗室无眩光和暗室有眩光对比敏感度阈值检测.结果:非球面型人工晶状体组的球面像差C12(构成4阶像差的主要成分)及第4阶像差均方根RMS4均低于球面型人工晶状体组,差异具有统计学意义;总高阶相差RMSh两组间差异无统计学意义.非球面型人工晶状体组的暗室无眩光对比敏感度阈值正常眼所占百分比为51.7%,暗室有眩光对比敏感度阈值正常眼所占百分比为58.6%;球面型人工晶体组暗室无眩光对比敏感度阈值正常眼所占百分比为32.0%,暗室有眩光对比敏感度阈值正常眼所占百分比为52.0%,两组分布差异无统计学意义.结论:非球面人工晶状体植入可明显减少球面像差,但对暗室对比敏感度无明显影响.  相似文献   

2.
目的:比较球面和非球面人工晶状体(IOL)植入术后患者的视觉质量。方法:选取老年性白内障患者36例(72眼)作为观察对象,根据植入的IOL不同将其分为620H组(球面IOL)和970C组(非球面IOL)。比较两组角膜Q值和IOL偏心值;术后6个月瞳孔6 mm的高阶像差、敏感度(CS)、眩光敏感度(GS)和高阶像差包括四阶球差(Z40)、四阶球差均方根(RMS4)、高阶像差均方根(RMSh)和四阶彗差(Z7、Z8)。结果:970C组Z40、RMS4、RMSh均明显低于620H组,在6.3°、4.0°视角的CS及GS均明显大于620H,差异均具有统计学意义(P<0.05),两组角膜Q值和IOL偏心值比较差异无统计学意义(P>0.05)。结论:非球面IOL植入术后的视觉质量优于球面IOL植入术。  相似文献   

3.
目的 评价非球面人工晶状体(IOL)AcrySof IQ IOL植入术后年龄相关性白内障患者的视觉质量.方法 年龄相关性白内障患者42例55眼,按随机数字表法将患者分成两组.其中非球面人工晶体组24例(28眼),植入AcrySof IQ IOL;球面人工晶体组18例(27眼),植入AcrySof Natural IOL.术后随访3个月的裸眼视力(UCVA)、最佳矫正远视力(BCVA),不同亮度环境下的对比敏感度等.结果 手术后3个月非球面组UCVA为0.76±0.18,优于球面组的0.66±0.17,差异有统计学意义(P<0.05).非球面组BCVA为0.85±0.19,优于球面组的0.74±0.19,差异有统计学意义(P<0.05).两组球镜、柱镜差异无统计学意义(P>0.05).在明视觉条件下,非球面组在12.0 cpd、18.0 cpd的对比敏感度明显优于球面组(P<0.01).在暗视觉条件下非球面组所有空间频率的对比敏感度非球面组均优于球面组(P<0.05).非球面组眩光、光晕等的发生率均低于球面组(P<0.05).结论 白内障术后早期,非球面人工晶状体能够提供较好的术后裸眼视力、最佳矫正远视力、亮环境下高频对比敏感度和暗环境下的所有空间频率的对比敏感度,提示非球面人工晶状体能够提供较好的视觉质量.  相似文献   

4.
目的白内障术后的视觉质量因人工晶状体的设计改进而显著改善。文中研究非球面人工晶状体植入术后患眼高阶像差及对比敏感度的特点,评价非球面人工晶状体对术眼视觉质量的影响。方法患者共80只眼分为2组,一组植入非球面人工晶状体Acrysoft SN60WF,一组植入球面人工晶状体Acrysoft SA60AT。术后进行角膜地形图波前像差及对比敏感度的测量。结果术后的最佳矫正视力及角膜高阶像差比较组间差异无统计学意义(P>0.05)。术后的高阶像差测量显示球面像差Zernike C12、4阶高阶像差及总体像差比较中SA60AT组大于SN60WF组,组间差异均具有统计学意义。眩光对比敏感度,在空间频率6、12、18c/d时,SN60WF组大于SA60AT组(P<0.05)。结论非球面人工晶状体可以减少球面像差,增加对比敏感度。  相似文献   

5.
目的前瞻对比性研究Akreos^TM系列人工晶状体植入术后视力、术眼波前像差的表现。方法选择年龄相关性白内障患者36例(40只眼),随机将患者分为2组:A组20例(20只眼)植入非球面(消像差)Akreos^TMAO人工晶状体、B组16例(20只眼)植入传统正球面Akreos^TM人工晶状体,分别于术前、术后一周和一月检查,采用ZEIZZ波前像差仪测量波前像差,并进行统计分析。结果2组患者术后矫正视力均大于0.9;非球面(消像差)Akreos^TMAO人工晶状体组术后四阶像差(S4)低于植入传统正球面Akreos^TM人工晶状组,两组术后的波前像差值中的四阶像差S4和Zern ike多项式中的Z(2,0)、Z(4,0)、Z(5,1)和Z(6,0)有统计上的差异,其它指标无统计学差异。结论白内障超声乳化术植入消像差Akreos^TMAO人工晶状体在夜视条件下即瞳孔直径大时,较植入传统正球面人工晶状体Akreos^TM的波前像差稍低,成像质量更好。  相似文献   

6.
目的 检测白内障三种单焦球面人工晶状体植入术后所获得视觉质量的差异.方法 选取行超声乳化联合折叠式人工晶状体植入术的单纯老年性白内障患者120人(120眼),分别植入肝素表面处理亲水性丙烯酸酯人工晶状体(HQ-201HEP组,n=40)、疏水性丙烯酸酯人工晶状体(Sensar AR40e组,n=40)或蓝光滤过人工晶状体(AcrySof Natural SN60AT组,n=40);另选取年龄相近的正常人40眼作为对照组.应用CSV-1000E对比敏感度仪测量对比敏感度及眩光对比敏感度,鹰视波前像差仪测定高阶像差,比较各组对比敏感度和眩光敏感度以及各级高阶像差之间的差异.结果 三组患者对比敏感度及眩光对比敏感度在各空间频率的差异均无统计学意义(P>0.05),但均低于对照组(P<0.05或P<0.01).三组患者间总高阶像差(RMSh)、三阶(RMS3)、四阶(RMS4)、五阶(RMS5)、六阶(RMS6)像差差异均无统计学意义(P>0.05);在球差(C12)、次级球差(C24)、RMSh、RMS3、RMS4、RMS5和RMS6均显著高于对照组(P<0.01).结论 白内障三种单焦球面人工晶状体植入术后对比敏感度功能和各级高阶像差无显著差异,视网膜成像质量无明显区别.植入单焦球面人工晶状体可部分恢复白内障患者的对比敏感度功能,但尚未达到正常同龄人水平.  相似文献   

7.
李永康  徐东 《中国现代医生》2013,51(12):41-42,45
目的 观察植入非球面人工晶状体和传统球面人工晶状体的临床效果.方法 选取我院收治的55例老年性白内障患者,按处理方法不同分为两组,观察组25例患者植入非球面人工晶状体;对照组30例患者植入传统球面人工晶状体.结果 观察组手术1周后患眼视力明显高于手术前,对照组手术1个月后明显高于手术前,观察组术后患眼视力恢复情况明显好于对照组(P 〈 0.05);手术后1个月和3个月,观察组患者的四阶球差和高阶像差都低于对照组,差异具有统计学意义(P 〈 0.05),且两组患者最佳矫正视力下的远、近立体视觉比较,差异具有统计学意义(P 〈 0.05).结论 非球面人工晶状体植入治疗白内障能够显著地减少球面像差,提高对比敏感度,改善手术后的视觉质量,值得临床推广应用.  相似文献   

8.
白内障患者不同人工晶状体植入术后视觉质量比较   总被引:1,自引:0,他引:1  
目的检测白内障三种单焦球面人工晶状体植入术后所获得视觉质量的差异。方法选取行超声乳化联合折叠式人工晶状体植入术的单纯老年性白内障患者120人(120眼),分别植入肝素表面处理亲水性丙烯酸酯人工晶状体(HQ-201HEP组,n=40)、疏水性丙烯酸酯人工晶状体(Sensar AR40 e组,n=40)或蓝光滤过人工晶状体(AcrySof Natural SN60AT组,n=40);另选取年龄相近的正常人40眼作为对照组。应用CSV-1000E对比敏感度仪测量对比敏感度及眩光对比敏感度,鹰视波前像差仪测定高阶像差,比较各组对比敏感度和眩光敏感度以及各级高阶像差之间的差异。结果三组患者对比敏感度及眩光对比敏感度在各空间频率的差异均无统计学意义(P>0.05),但均低于对照组(P<0.05或P<0.01)。三组患者间总高阶像差(RMSh)、三阶(RMS3)、四阶(RMS4)、五阶(RMS5)、六阶(RMS6)像差差异均无统计学意义(P>0.05);在球差(C12)、次级球差(C24)、RMSh、RMS3、RMS4、RMS5和RMS6均显著高于对照组(P<0.01)。结论白内障三种单焦球面人工晶状体植入术后对比敏感度功能和各级高阶像差无显著差异,视网膜成像质量无明显区别。植入单焦球面人工晶状体可部分恢复白内障患者的对比敏感度功能,但尚未达到正常同龄人水平。  相似文献   

9.
目的:探讨非球面人工晶状体眼术后早期对比敏感度(CSF)的变化。方法:选择年龄相关性白内障患者40例(40眼),随机将患者分为A、B两组,两组均行白内障超声乳化摘除联合人工晶状体植入手术,A组为植入非球面消像差人工晶状体Akreos TM AO,B组为植入正球面人工晶状体Akreos TM。结果:白内障术后植入非球面消像差人工晶状体Akreos TM AO组CSF值与植入正球面人工晶状体Akreos TM组比较CSF值差异有显著性(P〈0.05)。结论:年龄相关性白内障患者术后,两组人工晶状体眼的CSF值明显有差异,植入非球面消像差人工晶状体Akreos TM AO患者术后CSF值明显好于植入正球面人工晶状体Akreos TM患者。  相似文献   

10.
目的评价非球面人工晶状体(IOL)AcrySof IQ IOL植入术后年龄相关性白内障患者的视觉质量。方法年龄相关性白内障患者42例55眼,按随机数字表法将患者分成两组。其中非球面人工晶体组24例(28眼),植入AcrySof IQ IOL;球面人工晶体组18例(27眼),植入AcrySof Natural IOL。术后随访3个月的裸眼视力(UCVA)、最佳矫正远视力(BCVA),不同亮度环境下的对比敏感度等。结果手术后3个月非球面组UCVA为0.76±0.18,优于球面组的0.66±0.17,差异有统计学意义(P<0.05)。非球面组BCVA为0.85±0.19,优于球面组的0.74±0.19,差异有统计学意义(P<0.05)。两组球镜、柱镜差异无统计学意义(P>0.05)。在明视觉条件下,非球面组在12.0 cpd、18.0 cpd的对比敏感度明显优于球面组(P<0.01)。在暗视觉条件下非球面组所有空间频率的对比敏感度非球面组均优于球面组(P<0.05)。非球面组眩光、光晕等的发生率均低于球面组(P<0.05)。结论白内障术后早期,非球面人工晶状体能够提供较好的术后裸眼视力、最佳矫正远视力、亮环境下高频对比敏感度和暗环境下的所有空间频率的对比敏感度,提示非球面人工晶状体能够提供较好的视觉质量。  相似文献   

11.
Background The advent of wavefront technology in the past five years has provided some insight into the optical outcomes of cataract surgery. The Tecnis Z9001 intraocular lens (Tecnis IOL, AMO) with a modified prolate anterior surface was claimed to reduce or even eliminate ocular spherical aberration to improve the visual quality. The purpose of this study was to determine whether Tecnis IOLs can improve the quality of vision as evaluated by measuring visual acuity, wavefront aberration, and contrast sensitivity. Methods In an intraindividual prospective study, 20 patients with bilateral cataract were randomly assigned to receive a modified prolate anterior surface IOL (Tecnis Z9001, AMO) in one eye and a biconvex spherical surface IOL (CeeOn 911A, AMO) in the other. After 3 months, the following were investigated: best corrected visual acuity, pupil diameter, photopic and mesopic contrast sensitivity, and wavefront aberration of the whole eye (ocular), cornea, and internal plane. Results The differences in the best corrected visual acuity and pupil diameter between the two groups were not statistically significant. Negative 4th-order spherical aberration (Z4^0) was found in the Tecnis group, whereas positive Z4^0 found in the CeeOn group for the internal and ocular plane. Statistically significant differences were found at the ocular higher-aberrations between the two IOLs. Contrast sensitivity testing showed significantly better results in the Tecnis group at visual angles higher than 1.0 degree under photopic conditions and at visual angles higher than 1.6 degree under mesopic conditions both without glare and with glare in comparison with the CeeOn group. Conclusions The Tecnis Z9001 IOL with a modified prolate anterior surface produces negative spherical aberration and consequently reduces the higher-order aberrations in pseudophakic eyes. This leads to enhanced contrast sensitivity and improved functional vision compared to conventional spherical IOLs.  相似文献   

12.
人工晶状体眼波阵面像差变化   总被引:1,自引:0,他引:1  
目的研究超声乳化联合人工晶状体植入术对术眼波前像差及成像质量的影响。方法选择白内障患者96人(104眼),随机分为两组进行手术(植入不同类型直径的人工晶状体)。术后分别于1W与4W及12W观察术眼波阵面像差及其他相关变化。结果不同光学结构的人工晶状体均存在单色光像差,其中球差的影响最明显。Z4、Z9、Z12和Z24值在手术前后有显著性差异(P<0.05);RMS1~6、RMSg、RMSh值术后较术前均呈显著性下降(P<0.001)。折叠人工晶状体的类型(三片、一片)与术后RMS 3(r=-0.319)、RMS 4(r=-0.475)、RMS 5(r=-0.304)和RMSh(r=-0.408)值呈显著相关性(P均<0.05)。结论波前像差技术可以帮助揭示术后出现相关视觉问题的原因。白内障术后各阶像差较术前均显著性减小,光学成像质量提高,具特征性的改变是三叶草形的像差和四阶球差;三片式折叠人工晶状体眼的高阶像差小于一片式折叠人工晶状体眼。*  相似文献   

13.
目的探讨球面IOL和非球面IOL在植入术后的倾斜和偏心与患者视觉质量的影响。方法收集2009年6月~2011年10月在我院住院并行超声乳化白内障吸除联合人工晶状体植入术的患者40例,共50只眼。随机分为两组,分别植入球面及非球面人丁晶体,术后3~4个月测量倾斜与偏心值及各像差值、MTF值。结果AR40e组人工晶体相对于视轴的倾斜与偏心值分别为(2.93±0.91)。和(0.29±0.11)mm,ZA9003组分别为(2.95±1.02)。和(0.30±0.13)mm。两组的倾斜值和偏心值比较,差异无统计学意义(P〉0.05)。两组波前像差、总高阶像差、总4阶球差、慧差和不同空间频率的MTF(HOA)值比较,差异均有统计学意义(P〈0.05)。结论在正常条件下,非球面人工晶体的倾斜和偏心值不会危害其对角膜球差的补偿,因此没有降低视网膜成像质量。  相似文献   

14.
非球面衍射型多焦点人工晶状体植入术后视觉质量评价   总被引:1,自引:0,他引:1  
目的 评价非球面多焦点人工晶状体(AcrySof IQ ReSTOR IOL SN6AD3)植入术后的视觉质量.方法 对植入非球面多焦点人工晶状体的老年性白内障患者30例(35只眼)(试验组)与植入球面多焦点人工晶状体(AcrySof ReSTOR 10L SN60D3)患者40例(56只眼)(对照组)进行对比研究.观察患者的术后视力(远视力,70 cm中距视力,近视力)、焦点深度、高阶像差、对比敏感度和眩光敏感度,问卷形式调查视觉不良症状及满意度.结果 术后3个月裸眼近、远、中间视力≥0.5者,试验组分别为80%(20/35)、82.9%(29/35)、45.7%(16/35),对照组分别为76.8%(43/56)、80.4%(45/56)、39.3%(22/56),两组比较差异无统计学意义(P>0.05);术后3个月最佳矫正远视力下近、远、中间视力≥0.5者,试验组分别为88.6%(31/35)、91.4%(32/35)、54.3%(19/35),对照组分别为81.5%(49/56)、91.1%(51/56)、42.9%(24/56),两组比较差异无统计学意义(P<0.05).术后3个月试验组各频段对比敏感度和眩光敏感度高于对照组,差异有统计学意义(P<0.05).在+1.00~-1.00D,-1.50D和-2.50~-3.50D调节范围内,视力≥0.5者试验组分别为94.3%(33/35)、97.1%(34/35)、85.7%(30/35),对照组分别92.9%(52/56)、94.6%(53/56)、83.9%(47/56),两组比较差异无统计学意义(P>0.05).高阶像差Zemike常数项中两组的Z(4,0)、Z(4,2)、S3+S4和S总系数差异有统计学意义(P<0.05),其余的Zernike常数项、三阶像差和四阶像差各指标间两组比较差异无统计学意义(P>0.05).两组均无严重眩光症状,对照组有3眼诉有光晕症状,试验组仅有1眼诉有光晕症状,满意程度较高.结论 AcrySof IQ ReSTOR非球面多焦点人工晶状体可为患者提供良好的近、中、远全程视力,该人工晶状体具有产生负球差的非球面设计,可平衡角膜的正球差,从而降低了术后总体像差,提高了术眼对比敏感度和眩光敏感度,全面改善患者的视觉质量.  相似文献   

15.
目的 探讨年龄相关性白内障患者手术前后角膜非球面系数Q值的改变及临床意义.方法 采用前瞻性研究方法,将217例(332眼)年龄相关性白内障患者分为巩膜隧道切口联合非球面人工晶体组、巩膜隧道切口联合球面人工晶体组、透明角膜切口联合非球面人工晶体组及透明角膜切口联合球面人工晶体组.对比观察术前和术后3个月时角膜Q值以及视力的变化情况.结果 所有患者术后角膜Q值较术前略小(P=0.013).采用巩膜隧道切口与透明角膜切口对角膜Q值的影响无统计学差异(P=o.462);植入非球面人工晶体较植入球面人工晶体可显著降低角膜Q值,差异有显著性(P <0.001).结论 年龄相关性白内障超声乳化联合人工晶体植入手术后患者的角膜Q值减小;这和手术切口的位置无关,而和植入晶体的类型有一定关系;非球面IOL植入术后视觉质量优于球面IOL植入,在一定程度上可能和其角膜Q值改变更接近于正常眼有关.  相似文献   

16.
目的探讨不同程度近视患者波前像差特征。方法抽取2008-03~07在广西视光中心就诊的105例近视患者,其中男54例,女51例;年龄16~36岁;屈光度-0.50~-10.50DS(等效球镜)。采用美国VISX公司生产的WaveScan波前像差仪对所有患者进行波前像差检测,收集每位患者的波前像差数据。将近视患者按低、中、高度近视分组后,使用SPSS13.0统计软件采用One-wayANOVA单因素方差分析,LSD法比较三组间波前像差的差异。结果低、中、高度近视三组间的总像差两两之间均不相同,差异有统计学意义(F=203.044,P〈0.01),并且近视程度越高,总像差越大。而总高阶像差、三叶草、彗差、球差等四项数据在三组间的差异均无统计学意义(P〉0.05)。各近视组波前像差成分中,总高阶像差、三叶草、彗差、球差这四项指标的数值在各组中均呈依次降低。结论近视患者的总像差随着近视程度而增大,但高阶像差具有个体差异性。  相似文献   

17.
目的:比较虹膜定位波前像差引导的准分子激光原位角膜磨镶术(LASIK)和传统LASIK矫正高度近视术后3个月时波前像差的变化与对比敏感度、眩光敏感度的关系,探讨像差对视觉质量的影响。方法:将行虹膜定位波前像差引导的LASIK的高度近视患者9例(17眼)作为试验组,行传统LASIK的近视患者8例(14眼)作为对照组。对试验组和对照组术后3个月的视力、波前像差、对比敏感度和眩光敏感度进行统计学分析。结果:(1)试验组、对照组术后3个月的视力无统计学意义(P〉0.05),波前像差Zernike函数c4(离焦)、C7(垂直彗差)、C8(水平彗差)、三叶草差(C6、C9)、C12(球差)、RMSg(总体像差均方根值)、RMSh(高阶像差均方根值)无统计学意义(P〉0.05)。(2)术后3个月比较对比敏感度,白天在低频区3.0c/d、中频区6.0c/d空间频率下,有统计学意义(P〈0.05);晚上在低频区3.0c/d空间频率下,有统计学意义(P〈0.05)。白天+眩光在低频区3.0c/d空间频率下,有统计学意义(P〈0.05)。结论:虹膜定位波前像差引导的LASIK较传统LASIK矫正高度近视无更好的视觉质量。  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司    京ICP备09084417号-23

京公网安备 11010802026262号