首页 | 官方网站   微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
本文阐述了双联滑移齿轮在适当传动出情况下,轴向移动一个齿轮宽度就可以进行变速的可行性及适用场合。而一般书籍介绍,双联滑移齿轮的变速轴向至少移动二个齿宽。  相似文献   

2.
3.
从齿轮受力和失效特点出发,通过金相检验分析,指出了渗碳层中的碳化物对齿轮强度有害,渗碳淬火后的齿面应避免出现碳化物.在实际生产中为了使齿根含碳量接近共析成分,以齿顶部出现少量碳化物为宜.  相似文献   

4.
综合考虑了齿轮传动系统振动影响、润滑流体的可压缩性 ,以及滑动速度和曲率半径随时间和坐标的变化 ;进行了动载荷下的直齿轮传动弹流润滑数值分析 ,获得了齿轮传动沿啮合线的中心油膜及摩擦系数的分布 ,并给出了 7个特殊啮合点上的压力分布及油膜形状 .  相似文献   

5.
A displacement blood pump to support the natural heart of patients for recovery from end-stage heart failure has been developed. This electromechanical pusher plate pump has a very compact and extremely flat design. The design goal was achieved by developing a novel gear system based on the principle of a swash plate. The blood pump and cannulae can be placed within the thoracic cavity between the lungs and ribcage. The first labtype model delivers an output of 3.1 L/min against an aortic pressure of 100 mm Hg at 120 bpm.  相似文献   

6.
We present a numerical method and results for a recently published benchmark problem (Optim. Contr. Appl. Met. 2005; 26 :1–18; Optim. Contr. Appl. Met. 2006; 27 (3):169–182) in mixed‐integer optimal control. The problem has its origin in automobile test‐driving and involves discrete controls for the choice of gears. Our approach is based on a convexification and relaxation of the integer controls constraint. Using the direct multiple shooting method we solve the reformulated benchmark problem for two cases: (a) As proposed in (Optim. Contr. Appl. Met. 2005; 26 :1–18), for a fixed, equidistant control discretization grid and (b) As formulated in (Optim. Contr. Appl. Met. 2006; 27 (3):169–182), taking into account free switching times. For the first case, we reproduce the results obtained in (Optim. Contr. Appl. Met. 2005; 26 :1–18) with a speed‐up of several orders of magnitude compared with the Branch&Bound approach applied there (taking into account precision and the different computing environments). For the second case we optimize the switching times and propose to use an initialization based on the solution of (a). Compared with (Optim. Contr. Appl. Met. 2006; 27 (3):169–182) we were able to reduce the overall computing time considerably, applying our algorithm. We give theoretical evidence on why our convex reformulation is highly beneficial in the case of time‐optimal mixed‐integer control problems as the chosen benchmark problem basically is (neglecting a small regularization term). Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

7.
Abstract Immunoadsorption (1A) therapy with tryptophan (TR-350) or phenylalanine (PH-350) adsorbents has been used to reduce the concentration of serum antibodies in human lymphocyte antigen (HLA)-immunized patients. Other forms of plasma purification have been reported to reduce the level of fibrinogen, which affects the blood properties. In this study we investigated the effects of IA therapy using both adsorbents on plasma fibrinogen and immunoglobulins G and M in 13 patients (8 patients were treated with TR-350, and 5 patients were treated with PH-350). During each session 1 plasma volume (2.8 ± 0.4 L of plasma) was processed through the immunocolumn and then returned to the patient together with the blood cells. Compared with the pretreatment values, the plasma fibrinogen, IgG, and IgM concentrations were significantly reduced after IA therapy (p < 0.01 for TR-350; p < 0.04 for PH-350). There was a positive correlation between the degree of reduction of plasma proteins and the number of IA treatments given. A nonpara-metric test (Wilcoxon's signed-rank test or the Mann-Whitney test) was used for statistical analysis. We conclude from our study that IA therapy effectively lowers the plasma levels of fibrinogen, IgG, and IgM and thus can be considered a valuable alternative to other blood purification methods.  相似文献   

8.
Background: The duration of action of muscle relaxants is poorly correlated to the rate of decay of their plasma concentration. The plasma concentration of mivacurium may rapidly decrease below its active concentration because of the extensive hydrolysis of mivacurium. By inflating a tourniquet on one upper limb for 3 min after the administration of atracurium, mivacurium or vecuronium, we studied the influence of the initial decline of their plasma concentration on their effect. Methods: In 50 patients anaesthetised with thiopental, isoflurane and fentanyl, the effect of bolus doses of 0.15 or 0.25 mg . kg?1 mivacurium (MIV 15, MIV 25), 0.3 or 0.5 mg . kg?1 atracurium (ATR 30, ATR 50) and 0.06 or 0.1 mg . kg?1 vecuronium (VEC 06, VEC 10) were measured on both arms (evoked response of the adductor pollicis to train-of-four stimulation every 12 s), a tourniquet being applied on one arm just before and during 3 min after the muscle relaxant bolus. Results: Tourniquet inflation of 3 min almost abolished the neuromuscular effect of mivacurium. In the vecuronium groups and in the ATR 50 group, tourniquet inflation did not modify the maximum degree of depression of the twitch response. Also, the duration of action of vecuronium was unaffected by the tourniquet. In the ATR 30 group, times to return of the twitch response to 25% (duration 25%) and 75% (duration 75%) of control response were significantly shorter in the cuffed arm, 23 min vs 27 min, and 41 min vs 45 min, respectively. In the ATR 50 group, only duration 25% was significantly shorter in the cuffed arm (41 min vs 45 min). Conclusion: The results suggest that the rate of decline of the plasma concentration of mivacurium is so rapid, that a very low and almost clinically ineffective concentration is present as soon as 3 min after its administration. The results also indicate that the recovery from a mivacurium-induced neuromuscular blockade is not influenced by the rate of decay of its plasma concentration in patients with genotypically normal plasma cholinesterase.  相似文献   

9.
Abstract: Membrane processes play a pivotal and enabling role in modern replacement therapy for acute and chronic organ failure and in the management of immunologic diseases. In fact, virtually all contemporary extracorporeal blood purification methods employ membrane devices, and the next generation of artificial organs and tissue engineering therapies are almost certain to be similarly grounded in membrane technology. In this short essay, we comment on the similarities and differences among synthetic membranes and their natural counterparts and also provide a critical overview of the demographics and technology of hemodialysis, hemofiltration, apheresis, oxygenation, and emerging membrane technologies and applications.  相似文献   

10.
Blunt trauma is the principal cause of childhood death in many developed countries. This review outlines the differences between adults and children with respect to resuscitation and treatment of orthopaedic injuries in a child with polytrauma. Recent advances in techniques of fracture stabilization are reported.  相似文献   

11.
12.
Abstract: Numerous articles have been published on the multiple use of dialyzers and on the effect of different reprocessing chemicals and techniques on the dialyzer biocompatibility and performance. The results often appear contradictory, especially those comparing standard biocompatibility parameters. Despite this confusion, a discerning review of the published works allows certain limited conclusions to be drawn. Reprocessing of used hemodialyzers changes the biocompatibility profile of a dialyzer as defined by the parameters complement activation. leukopenia, and cytokine release. The effect of reprocessing depends on the chemicals and reprocessing technique applied and also on the type of membrane polymer being subjected to the reprocessing procedure. Reports of pyrogenic reactions indicate that the flux of the membrane also influences how suitable it is for safe reuse. An increased risk of allergic and pyrogenic reactions appears to be associated with dialyzer reuse. Furthermore, there has been a lack of investigations into the immunologic effect of the layer of adsorbed and chemically altered proteins that remains on the inner surface of reprocessed dialyzers. We conclude that the clinical benefit of dialyzer reuse cannot be generally accepted from a biocompatibility point of view.  相似文献   

13.
Background : Ketamine in sub-dissociative doses has been shown to have analgesic and phantom-Limb pain, where conventional treatment has often failed. Chronic ischemic pain due to lower extremity arteriosclerosis obliterans often responds poorly to analgesics, and the pain-generating mechanisms are not well understood.
Methods : Eight patients with rest pain in the lower extremity due to arteriosclerosis obliterans were given sub-dissociative doses of 0.15, 0.30, or 0.45 mg/kg racemic ketamine and morphine 10 mg as a 5-min infusion on four separate days in a cross-over, double-blind, randomised protocol. Plasma levels of (S)- and (R)-ketamine and their nor-metabolites were analysed with an enantioselective high-performance liquid chromatography (HPLC) method. Pain levels were evaluated with a visual analogue scale (VAS).
Results : Individual pain levels were highly variable during and after all the infusions but the pooled pain levels showed a dose-dependent analgesic effect of ketamine with a transient but complete pain relief in all patients at the highest dose (0.45 mg/ kg). Side-effects, mainly disturbed cognition and perception, were pronounced and dose-dependent. Morphine 10 mg had an analgesic peak at 20 min and 5/8 patients had complete pain relief. The remaining 3 patients also had high baseline pain scores, indicating a higher analgesic potency for the 0.30 and 0.45 mg/ kg ketamine doses than for morphine 10 mg.
Conclusion : We have demonstrated a potent dose-dependent analgesic effect of racemic ketamine in clinical ischemic pain. Due to a narrow therapeutic window, this analgesic effect is probably best utilised in combination with other analgesics.  相似文献   

14.
Background : It is unclear whether activation of the inducible nitric oxide synthase (iNOS) increases or decreases the extravasation of plasma.
Methods : Chloralose anaesthetised male Wistar rats received E. coli lipopolysacharide (LPS), 3 mg kg-1 i.v., or the corresponding volume of saline, 3 or 5 h before the end of the experiment. Mean arterial pressure (MAP) and heart rate (HR) were recorded. Tissue clearance of radio-labelled albumin, during the last 2 h of each experiment, was determined by a double-isotope method. In separate animals, the serum concentration of nitrite and nitrate was determined, 5 h after LPS or the solvent.
Main Results : LPS initially decreased MAP and lastingly increased HR. In the 3-h LPS animals (n=8), tissue plasma clearance was lower in the heart and calf muscle and increased only in diaphragm, compared to corresponding control animals (n=8). In the 5-h LPS rats, clearance was lowered (n=8) in the entire gastrointestinal tract and in testes, compared to controls (n=8). The serum nitrite/nitrate concentration was higher in animals given LPS (n=6) than in controls (n=6).
Conclusion : After LPS, tissue clearance of albumin was not increased in any major tissue, in spite of increased serum levels of NO end products. Apparently, after activation of iNOS, the augmented release of NO is not necessarily associated with increased albumin extravasation.  相似文献   

15.
16.
Background: Basic pharmacological research indicates that there are synergistic antinociceptive effects at the spinal cord level between adrenaline, fentanyl and bupivacaine. Our clinical experience with such a mixture in a thoracic epidural infusion after major surgery confirms this. The objectives of the present study were to evaluate the effects on postoperative pain intensity, pain relief and side effects when removing adrenaline from this triple epidural mixture. Methods: A prospective, randomised, double-blind, cross-over study was carried out in 24 patients after major thoracic or abdominal surgery. Patients with only mild pain when coughing during a titrated thoracic epidural infusion of about 10 ml · h?1 of bupivacaine 1 mg · ml?1, fentanyl 2 μg · ml?1, and adrenaline 2 μg · ml?1 were included. On the 1st and 2nd postoperative days each patient was given a double-blind epidural infusion, at the same rate, with or without adrenaline. The effect was observed for 4 h or until pain when coughing became unacceptable in spite of a rescue analgesic procedure. Rescue analgesia consisted of up to two epidural bolus injections per hour and i.v. morphine if necessary. All patients received rectal paracetamol 1 g, every 8 h. Fentanyl serum concentrations were measured with a radioimmunoassay technique at the start and end of each study period. Main outcome measures were extent of sensory blockade and pain intensity at rest and when coughing, evaluated by a visual analogue scale, a verbal categorical rating scale, the Prince Henry Hospital pain score, and an overall quality of pain relief score. Results: The number of hypaesthetic dermatomal segments decreased (P <0.001) and pain intensity at rest and when coughing increased (P <0.001) when adrenaline was omitted from the triple epidural mixture. This change started within the first hour after removing adrenaline. After 3 h pain intensity when coughing had increased to unacceptable levels in spite of rescue analgesia (epidural bolus injections and i.v. morphine). Within 15–20 min after restarting the triple epidural mixture with adrenaline, pain intensity was again reduced to mild pain when coughing. Serum concentration of fentanyl doubled from 0.22 to 0.45 ng · ml?1 (P <0.01), and there was more sedation during the period without adrenaline. Conclusions: Adrenaline increases sensory block and improves the pain-relieving effect of a mixture of bupivacaine and fentanyl infused epidurally at a thoracic level after major thoracic or abdominal surgery. Serum fentanyl concentrations doubled and sedation increased when adrenaline was removed from the epidural infusion, indicating more rapid vascular absorption and systemic effects of fentanyl.  相似文献   

17.
Abstract: Low-density lipoprotein (LDL) is widely recognized as one of the major risk factors for developing coronary heart diseases. Despite intensive development of LDL-lowering drugs, there still exist those patients with refractory hyperlipidemia whose plasma LDL levels are not sufficiently lowered by drugs. LDL apheresis, direct removal of plasma LDL from circulating blood, is thought to be the most promising treatment for such refractory patients. Various techniques, such as the use of an im-munoadsorbent utilizing an anti-LDL antibody, have been used in an attempt to achieve the selective removal of LDL. However, none were widely used because of complications, poor selectivity, and so forth. To establish a safe and effective LDL apheresis system, we chose a synthetic affinity adsorbent as the LDL-removing device. Synthetic polyanion compounds were used as the affinity ligands for LDL adsorbent to simulate the anion-rich sequence of LDL binding sites in the human LDL receptor. Among various polyanion compounds, those polyanions with sulfate or sulfonate groups and hydrophilic backbone were found to have strong affinity for LDL. In contrast, polyanions with carboxyl groups showed poor affinity. Dextran sulfate (DS) was selected as the affinity ligand of LDL adsorbent for its high affinity and low toxicity. The influence of its charge density and molecular weight on its affinity for LDL was suitable. The affinity rapidly increased as the charge density increased, then, reached a constant value. Little affinity was found for either the DS monomer (glucose sulfate) or DS with a molecular weight higher than 104 daltons whereas DS with molecular weights in the midrange showed strong affinity. DS with a midrange molecular weight was immobilized on cellulose hard gel to give LDL adsorbent clinical application. The adsorbent demonstrated an excellent selectivity for LDL and very low density lipoprotein (VLDL) in vitro. Adsorption of high-density lipoprotein and major plasma proteins was almost negligible. Additional study of the LDL-binding mechanism revealed that DS directly interacts with positively charged sites on LDL, which demonstrates that the nature of the interaction is the same as that of LDL receptor. An LDL adsorption column (Liposorber) packed with an LDL adsorbent and polysulfone hollow-fiber plasma separator (Sulflux) was developed as an efficient LDL apheresis system. Clinical investigation proved that this system is capable of intensively lowering the plasma LDL level without affecting major plasma components.  相似文献   

18.
In this Editor's Review, articles published in 2010 are organized by category and briefly summarized. As the official journal of The International Federation for Artificial Organs, The International Faculty for Artificial Organs, and the International Society for Rotary Blood Pumps, Artificial Organs continues in the original mission of its founders "to foster communications in the field of artificial organs on an international level."Artificial Organs continues to publish developments and clinical applications of artificial organ technologies in this broad and expanding field of organ Replacement, Recovery, and Regeneration from all over the world. We take this time also to express our gratitude to our authors for offering their work to this journal. We offer our very special thanks to our reviewers who give so generously of time and expertise to review, critique, and especially provide such meaningful suggestions to the author's work whether eventually accepted or rejected and especially to those whose native tongue is not English. Without these excellent and dedicated reviewers the quality expected from such a journal could not be possible. We also express our special thanks to our Publisher, Wiley-Blackwell, for their expert attention and support in the production and marketing of Artificial Organs. In this Editor's Review, that historically has been widely received by our readership, we aim to provide a brief reflection of the currently available worldwide knowledge that is intended to advance and better human life while providing insight for continued application of technologies and methods of organ Replacement, Recovery, and Regeneration. We look forward to recording further advances in the coming years.  相似文献   

19.

Background and objectives

The interactive approach of a journal club has been described in the medical education literature. The aim of this investigation is to present an assessment of journal club as a tool to address the question whether residents read more and critically.

Methods

This study reports the performance of medical residents in anesthesiology from the Clinics Hospital – University of São Paulo Medical School. All medical residents were invited to answer five questions derived from discussed papers. The answer sheet consisted of an affirmative statement with a Likert type scale (totally disagree–disagree–not sure–agree–totally agree), each related to one of the chosen articles. The results were evaluated by means of item analysis – difficulty index and discrimination power.

Results

Residents filled one hundred and seventy three evaluations in the months of December 2011 (n = 51), July 2012 (n = 66) and December 2012 (n = 56). The first exam presented all items with straight statement, second and third exams presented mixed items. Separating “totally agree” from “agree” increased the difficulty indices, but did not improve the discrimination power.

Conclusions

The use of a journal club assessment with straight and inverted statements and by means of five points scale for agreement has been shown to increase its item difficulty and discrimination power. This may reflect involvement either with the reading or the discussion during the journal meeting.  相似文献   

20.
Enteral feeding is often limited by gastric and intestinal motility disturbances in critically ill patients, particularly in patients with shock. So, promotility agents are frequently used to improve tolerance to enteral nutrition. This review summaries the pathophysiology, presents the available pharmacological strategies, the clinical data, the counter-indications and the principal limits. The clinical data are poor. No study demonstrates a positive effect on clinical outcomes. Metoclopramide and erythromycin seems to be the more effective. Considering the risk of antibiotic resistance, the first line use of erythromycin should be avoided in favor of metoclopramide.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司    京ICP备09084417号-23

京公网安备 11010802026262号