共查询到20条相似文献,搜索用时 320 毫秒
1.
Michael A. Bergen Kevin C. Wall Charles Y. Kim Grant E. Garrigues 《The Journal of arthroplasty》2019,34(2):375-378
Background
Left common iliac vein (LCIV) compression by the right or left common iliac artery (RCIA, LCIA) is known to cause venous thromboembolism (VTE), but the extent to which occult LCIV compression synergizes with lower extremity orthopedic surgery is unknown. We hypothesize that occult LCIV compression is associated with increased VTE risk following total hip or knee arthroplasty (THA, TKA).Methods
This case-control study involves all patients at our institution who underwent primary or revision THA or TKA from 2009 to 2017 who had computed tomography or magnetic resonance imaging of the abdomen or pelvis available preoperatively. VTE cases (pulmonary embolism or left-sided deep vein thrombosis) within 30 days of surgery were matched to a control by age, gender, body mass index, Charlson Comorbidity Index, surgical site, and hypercoagulable risk factors. LCIV compression by the right common iliac artery and/or the left common iliac artery was measured in a blinded fashion and was considered present at 50% diameter reduction.Results
One hundred twelve patients (22 cases, 90 controls) were included for analysis. Nineteen (86.4%) cases and 46 (51.1%) controls demonstrated LCIV compression. The overall sample odds ratio of postoperative VTE in the presence of LCIV compression was 5.97 (95% confidence interval 1.59-33.67, P = .003). In patients who underwent THA (n = 75), LCIV compression was highly predictive of VTE (odds ratio ∞, 95% confidence interval 2.83-∞, P < .001). Compression in the TKA patients did not significantly predict VTE.Conclusion
Compression of the LCIV significantly increases odds of developing postoperative VTE following THA. This effect may suggest a new method of stratifying VTE risk in the orthopedic population to reduce VTE-associated morbidity and mortality. 相似文献2.
3.
Ibrahim Sultan Valentino Bianco Arman Kilic Danny Chu Forozan Navid Thomas G. Gleason 《The Journal of thoracic and cardiovascular surgery》2019,157(1):45-50
Objective
To study mid-term survival in patients with infective endocarditis as a result of IV drug use undergoing aortic root replacement with cryopreserved aortic homograft.Methods
Patients undergoing aortic root homograft replacement from 2011-2017 were studied retrospectively. Aortic root replacement was performed using a modified Bentall technique. Primary outcomes included both short-term and mid-term survival. Secondary outcomes included immediate postoperative complications.Results
A total of 138 patients underwent cryopreserved homograft replacement of the aortic root for aortic root abscesses. Eighty-five patients (61.6%) underwent reoperative sternotomy, and 12 patients (8.7%) underwent second or third reoperative sternotomy. Sixty-seven (48.5%) patients had severe aortic insufficiency preoperatively. Operative mortality was 12.3% (17 patients). Five patients (3.6%) sustained a permanent stroke. Twenty-one patients (15.2%) required dialysis for renal failure, and 21 patients (15.2%) had complete heart block necessitating a permanent pacemaker. Estimated 5-year mortality for the cohort was 43%.Conclusions
Cryopreserved homograft replacement is a safe and desirable option for high-risk patients with infective endocarditis and aortic root abscess. Homograft accommodation for a widely debrided aortic annular bed provides a reasonable surgical strategy for patients needing aortic root replacement with annular abscess. 相似文献4.
G. Peluso P. Incollingo N. Carlomagno V. DAlessandro V. Tammaro M. Caggiano M.L. Sandoval Sotelo N. Rupealta M. Candida G. Mazzoni S. Campanile G. Chiacchio A. Scotti M.L. Santangelo 《Transplantation proceedings》2019,51(1):160-163
Background
Patients on peritoneal dialysis treatment represent 15% of the global dialysis population. The major complication of peritoneal dialysis is catheter and peritoneal infection. Peritoneal dialysis patients who receive kidney transplants are at increased risk of infection because of immunosuppressive therapy.Aim
The purpose of this study is to show our ideal timing to remove peritoneal catheter after kidney transplant, which gives adequate security on renal function recovery and reduction of septic risk.Method of Study
We analyzed the outcomes of 65 patients on peritoneal dialysis who underwent kidney transplant between 2000 and 2016.Results
In 61 cases there was an immediate graft functional recovery. In 4 cases there was a delayed graft function (DGF), and we performed a hemodialysis with temporary placement of a venous catheter. In all patients we removed peritoneal dialysis catheter 30 to 45 days after transplant. There has been 1 case of catheter infection, which was treated with antibiotic therapy.Discussion
Our average time to remove the peritoneal dialysis catheter was shorter than times in previous studies, between the 30th and 45th postoperative day. In the 4 cases in which there has been a DGF, we performed hemodialysis treatment to avoid, in the immediate postoperative period, direct insults to the peritoneum by local dialysis procedures.Conclusion
Our experience show that the 30th to 45th postoperative day is a good time frame, better yet a good watershed between the safe removal of peritoneal catheter when patients have a stabilized renal function and the possibility of leaving it in situ, to resume peritoneal dialysis in case of persistent DGF. 相似文献5.
Ger Bennink Sho Torii Marieke Brugmans Martijn Cox Oleg Svanidze Elena Ladich Thierry Carrel Renu Virmani 《The Journal of thoracic and cardiovascular surgery》2018,155(6):2591-2601.e3
Objective
To evaluate the safety and the short-term function of a novel pulmonary valved conduit (Xeltis Pulmonary Valved Conduit; XPV) up to 12 months in a sheep model.Methods
XPV and Hancock bioprosthetic valved conduits (H, used as control) were implanted in adult sheep in the pulmonary artery position. Animals were killed at 2 months (n = 6 XPV), 6 months (n = 6 XPV and n = 3 H), and 12 months (n = 6 XPV) and examined histologically. During follow-up, function of the device as well as diameter of both XPV and H were assessed by transthoracic echocardiography.Results
Of 18 animals that received an XPV, 15 survived until they were killed; 3 animals that received H survived the planned observational interval. XPV showed mild neointimal thickening and degradation beginning at 2 months with an ongoing process until 12 months. Only 1 of the 18 animals with XPV had significant calcification at 6 months. Pathologic specimen did not show any significant narrowing of the conduit whereas neointimal thickness showed a peak at 6 months. Inflammatory process reached a maximum at 6 months and the degradation process at 12 months. Gel permeation chromatography analysis showed molecular weight loss beginning at 2 months with a peak at 12 months for the conduit with slower absorption for the leaflets. The wall of the H conduits showed more neointimal thickening, narrowing, and calcification compared with XPV, but the leaflets demonstrated minimal changes.Conclusions
Both conduits demonstrated an acceptable safety and functionality. Significant calcification was rarely observed in the XPV, whereas the H developed more neointimal thickness with calcification of the porcine aortic root portion of the wall. 相似文献6.
Hong-En Chen Cheyenne C. Sonntag David F. Pepley Rohan S. Prabhu David C. Han Jason Z. Moore Scarlett R. Miller 《American journal of surgery》2019,217(2):362-367
Background
The objective of this study was to determine whether gaze patterns could differentiate expertise during simulated ultrasound-guided Internal Jugular Central Venous Catheterization (US-IJCVC) and if expert gazes were different between simulators of varying functional and structural fidelity.Methods
A 2017 study compared eye gaze patterns of expert surgeons (n?=?11), senior residents (n?=?4), and novices (n?=?7) during CVC needle insertions using the dynamic haptic robotic trainer (DHRT), a system which simulates US-IJCVC. Expert gaze patterns were also compared between a manikin and the DHRT.Results
Expert gaze patterns were consistent between the manikin and DHRT environments (p?=?0.401). On the DHRT system, CVC experience significantly impacted the percent of time participants spent gazing at the ultrasound screen (p?<?0.0005) and the needle and ultrasound probe (p?<?0.0005).Conclusion
Gaze patterns differentiate expertise during ultrasound-guided IJCVC placement and the fidelity of the simulator does not impact gaze patterns. 相似文献7.
Robert P. Runner Michael B. Gottschalk Christopher A. Staley Aidin E. Pour James R. Roberson 《The Journal of arthroplasty》2019,34(4):729-734
Background
Many strategies for venous thromboembolism (VTE) prophylaxis following hip and knee arthroplasty exist, with extensive controversy regarding the optimum strategy to minimize risk of VTE and bleeding complications. Data from the American Board of Orthopedic Surgery Part II (oral) Examination case list database was analyzed to determine efficacy, complication rates, and prescribing patterns for different prophylactic strategies.Methods
The American Board of Orthopedic Surgery case database was queried utilizing Current Procedural Terminology codes 27447 and 27130 for primary total knee and hip arthroplasty, respectively. Geographic region, patient age, gender, deep vein thrombosis prophylaxis strategy, and complications were obtained. Less aggressive prophylaxis patterns were considered if only aspirin and/or sequential compression devises were utilized. More aggressive VTE prophylaxis patterns were considered if any of low-molecular-weight heparin (enoxaparin), warfarin, rivaroxaban, fondaparinux, or other strategies was used.Results
In total, 22,072 cases of primary joint arthroplasty were analyzed from 2014 to 2016. The national rate of less aggressive VTE prophylaxis strategies was 45.4%, while more aggressive strategies were used in 54.6% of patients. Significant regional differences in prophylactic strategy patterns exist between the 6 regions. The predominant less aggressive prophylaxis pattern was aspirin with sequential compression devises at 84.8% with 14.8% receiving aspirin alone. Use of less aggressive prophylaxis strategy was significantly associated with patients having no complications (95.5% vs 93.0%). Use of more aggressive prophylaxis patterns was associated with higher likelihood of mild thrombotic (0.9% vs 0.2%), mild bleeding (1.3% vs 0.4%), moderate thrombotic (1.2% vs 0.4%), moderate bleeding (2.7% vs 2.1%), severe thrombotic (0.1% vs 0.0%), severe bleeding events (1.2% vs 0.9%), infections (1.9% vs 1.3%), and death within 90 days (0.7% vs 0.3%). Similar results were found in subgroup analysis of total hip and knee arthroplasty patients.Conclusion
It was not possible to ascertain the individual rationale for use of more aggressive VTE prophylaxis strategies; however, more aggressive strategies were associated with higher rates of bleeding and thrombotic complications. Less aggressive strategies were not associated with a higher rate of thrombosis.Level of Evidence
Therapeutic Level III.Disclaimer
All views expressed in the study are the sole views of the authors and do not represent the views of the American Board of Orthopedic Surgery. 相似文献8.
Study Design
Case series.Introduction
Upper extremity (UE) trauma and subsequent immobilization affects functional performance.Purpose of the Study
Determine the usefulness and feasibility of unilateral hand training (UHT) on improving functional performance in patients with UE trauma.Methods
Nine participants received UHT within 10 days of immobilization. Functional performance, dexterity, grip, and pinch strength were measured at initial and 4-week visits. Qualitative interviews were coded to develop themes.Results
All Jebsen-Taylor hand function test subtests improved from pretest to post-test. Disabilities of the Arm, Shoulder and Hand scores of all 9 participants improved. Functional performance was more impaired for participants with dominant UE injury. Four themes emerged: participants were forced to alter or avoid most daily activities, had an increased dependency on others, took longer to perform activities, and felt UHT decreased the impact of UE trauma on function.Discussion
Functional performance was impaired for all participants. Participants believed that UHT was useful and contributed to improved function.Conclusion
This case series tracked a comprehensive intervention based on a holistic activities of daily living framework that considered the nuances of individual complexities of immobilization following hand trauma. Knowledge from this study supports an early intervention like UHT to educate clients on effective strategies to improve immediate activities of daily living functioning and potentially prevent longer term impairments. 相似文献9.
Micah W. Smith Agnes Ith Eugene J. Carragee Ivan Cheng Todd F. Alamin S. Raymond Golish Kyle Mitsunaga Gaetano J. Scuderi Matthew Smuck 《The spine journal》2019,19(2):e28-e33
Background context
Protein biomarkers associated with lumbar disc disease have been studied as diagnostic indicators and therapeutic targets. Recently, a cartilage degradation product, the fibronectin-aggrecan complex (FAC) identified in the epidural space, has been shown to predict response to lumbar epidural steroid injection in patients with radiculopathy from herniated nucleus pulposus (HNP).Purpose
Determine the ability of FAC to predict response to microdiscectomy for patients with radiculopathy due to lumbar disc herniationStudy design/setting
Single-center prospective consecutive cohort study.Patient sample
Patients with radiculopathy from HNP with concordant symptoms to MRI who underwent microdiscectomy.Outcomes measures
Oswestry disability index (ODI) and visual analog scores (VAS) were noted at baseline and at 3-month follow-up. Primary outcome of clinical improvement was defined as patients with both a decrease in VAS of at least 3 points and ODI >20 points.Methods
Intraoperative sampling was done via lavage of the excised fragment by ELISA for presence of FAC. Funding for the ELISA was provided by Cytonics, Inc.Results
Seventy-five patients had full complement of data and were included in this analysis. At 3-month follow-up, 57 (76%) patents were “better.” There was a statistically significant association of the presence of FAC and clinical improvement (p=.017) with an 85% positive predictive value. Receiver-operating-characteristic (ROC) curve plotting association of FAC and clinical improvement demonstrates an area under the curve (AUC) of 0.66±0.08 (p=.037). Subset analysis of those with weakness on physical examination (n=48) plotting the association of FAC and improvement shows AUC on ROC of 0.81±0.067 (p=.002).Conclusions
Patients who are “FAC+” are more likely to demonstrate clinical improvement following microdiscectomy. The data suggest that the inflammatory milieu plays a significant role regarding improvement in patients undergoing discectomy for radiculopathy in lumbar HNP, even in those with preoperative weakness. The FAC represents a potential target for treatment in HNP. 相似文献10.
Ignacio G. Berra Peter E. Hammer Sebastian Berra Alfredo Oscar Irusta Seok Chang Ryu Douglas P. Perrin Nikolay V. Vasilyev Carlos Javier Cornelis Pablo Garcia Delucis Pedro J. del Nido 《The Journal of thoracic and cardiovascular surgery》2019,157(1):126-132
Objective
Aortic valve repair is currently in transition from surgical improvisation to a reproducible operation and an option for many patients with aortic regurgitation. Our research efforts at improving reproducibility include development of methods for intraoperatively testing and visualizing the valve in its diastolic state.Methods
We developed a device that can be intraoperatively secured in the transected aorta allowing the aortic root to be pressurized and the closed valve to be inspected endoscopically. Our device includes a chamber that can be pressurized with crystalloid solution and ports for introduction of an endoscope and measuring gauges. We show use of the device in explanted porcine hearts to visualize the aortic valve and to measure leaflet coaptation height in normal valves and in valves that have undergone valve repair procedures.Results
The procedure of introducing and securing the device in the aorta, pressurizing the valve, and endoscopically visualizing the closed valve is done in less than 1 minute. The device easily and reversibly attaches to the aortic root and allows direct inspection of the aortic valve under conditions that mimic diastole. It enables the surgeon to intraoperatively study the valve immediately before repair to determine mechanisms of incompetence and immediately after the repair to assess competence. We also show its use in measuring valve leaflet coaptation height in the diastolic state.Conclusions
This device enables more relevant prerepair valve assessment and also enables a test of postrepair valve competence under physiological pressures. 相似文献11.
Nikolaus Johannes Wachter Martin Mentzel Gert D. Krischak Joachim Gülke 《Journal of hand therapy》2019,32(1):64-70
Study Design
A within-subject research design was used in this study. The difference of the range of motion (ROM) with and without ulnar nerve block was analyzed.Introduction
For the clinical evaluation of the functional effects of ulnar nerve palsy at the hand the relevance of clinical tests is in discussion.Purpose of the Study
The aim of the study was to evaluate the predictive value of 2 clinical tests for a simulated ulnar nerve lesion by motion analysis with a sensor glove.Methods
In 28 healthy subjects, dynamic measurements of the finger joints were performed by a sensor glove with and without ulnar nerve block at the wrist. In the 0° metacarpophalangeal (MCP) stabilization test, the subjects were asked to stabilize the MCP joints actively in 0° while moving the interphalangeal joints, whereas at the 90° MCP stabilization test, the subjects stabilized the MCP joints actively in the 90° position.Results
In the 0° MCP stabilization test, no remarkable changes of the ROM were found at the MCP joints; at the proximal interphalangeal joints 2-5, the ROM decreased with ulnar nerve block, significantly at the index, middle, and ring fingers (P < .05). In the 90° MCP stabilization test, the average ROM of the MCP joints 2-5 significantly increased with ulnar nerve block (P < .05), whereas at the PIP joints, the average ROM decreased (P < .05).Discussion
The 90° MCP stabilization test had a high predictive value for the discrimination between healthy subjects and subjects with a simulated peripheral ulnar nerve lesion.Conclusions
The results could be relevant for the determination of the functional effect of ulnar nerve palsy and the quantification of clawing in hand rehabilitation.Level of Evidence
II. 相似文献12.
Study Design
Case series.Introduction
A salvaged limb is one that has undergone a major traumatic injury, followed by repeated surgical attempts in order to avoid amputation. Psychological recovery for individuals with lower extremity limb salvage has been examined in a number of studies. However, psychosocial reactions for individuals with upper extremity (UE) limb salvage are understudied in the literature.Purpose of the Study
The purpose of this study was to explore the process of psychosocial adaptation for 3 trauma cases after UE limb salvage.Methods
The Reactions to Impairment and Disability Inventory was used to assess psychosocial adaptation. Physical function outcomes (pain, range of motion, edema, sensation, and dexterity) are presented. The Disabilities of the Arm, Shoulder, and Hand measure was used to assess perceived disability. Medical and rehabilitation history are discussed for each case, in order to provide in-depth understanding of the impact of these injuries.Results
Reactions to injury varied across the cases; however, outcomes suggest that psychosocial adaptation may be influenced by the experience of pain, the ability to participate in valued roles and activities, and having a supportive social network.Discussion
For this population, therapists may consider emphasizing pain management, focusing on client-centered goals and interventions, and facilitating peer support. Providers should closely monitor patients for signs of poor adaptation, such as hand-hiding behaviors.Conclusions
This study is among the first to examine psychological outcomes for the UE limb salvage population. Future research would be beneficial to provide deeper understanding of the psychosocial challenges for these individuals. 相似文献13.
Study Design
Case report.Introduction
Development of extensor tendon adhesions is a common complication after intra-articular metacarpal head fracture. Whenever these adhesions cannot be mobilized by rehabilitation, tenolysis should be considered. However, the decision for tenolysis is often delayed. When the rehabilitation program comes to a plateau and clinical examination may not be sufficient to find out the cause, dynamic ultrasound (US) can show where the gliding mechanism is disrupted and help clinicians to give an accurate decision for determining the next steps.Purpose of the Study
To determine the role of dynamic US during hand rehabilitation.Methods
A 22-year-old woman presented with a fifth metacarpal intra-articular head fracture. Ten days after the surgery (open reduction and internal fixation) the hand rehabilitation program was commenced. After the third week, the metacarpophalangeal (MP) joint range of motion (ROM) gradually diminished. Dynamic US near the level of fifth MP joint revealed diminished extensor tendon excursion and capsular thickening.Results
Considering physical and sonographic findings, surgical tenolysis and capsular release was planned. After surgery, the DIP, PIP and MP joints reached full passive ROM.Conclusion(s)
Ultrasound is a quick and practical way to diagnose tendon adhesions. With this report, the authors suggest that clinicians may use dynamic US, especially in times when the patient comes to plateau during hand rehabilitation.Level of Evidence
IV. 相似文献14.
Hisayuki Hongu Masaaki Yamagishi Yoshinobu Maeda Keiichi Itatani Satoshi Asada Shuhei Fujita Hitoshi Yaku 《The Journal of thoracic and cardiovascular surgery》2019,157(5):1970-1977
Objective
Conventional procedures for partial anomalous pulmonary venous return (PAPVR) to the superior vena cava (SVC) still have serious complications, such as late SVC and/or pulmonary venous obstruction and supraventricular arrhythmia. We aimed to introduce our newly developed surgical technique with minimum right atriotomy and double-barreled arrangement of systemic and pulmonary venous channels (double-decker technique).Methods
From 1998 to 2018, 21 consecutive patients with PAPVR to the SVC underwent this new procedure. The patients' median age and body weight were 4.4 years and 16.5 kg, respectively. Two female patients underwent lateral thoracotomy. Postoperative hemodynamics of both venous channels were assessed using time-resolved 3-dimensional magnetic resonance phase contrast imaging in 6 patients.Results
The median follow-up period was 11.0 years. There was no early mortality and late death. No patient required reoperation and/or intervention. All patients maintained normal sinus rhythm, and supraventricular arrhythmia did not occur. The median blood flow velocity of the neo-SVC and neopulmonary venous channel was 0.40 and 0.30 m/s, respectively. Using time-resolved 3-dimensional magnetic resonance phase contrast imaging, the straight and nonrestrictive flow and low wall shear stress were visualized in both venous channels.Conclusions
Our newly developed double-decker technique is a useful alternative surgical procedure for PAPVR to the SVC. Late complications can be completely avoided using this method. Growth potential of both channels is also maintained. 相似文献15.
Joseph A. Gil Kerry Ebert Keri Blanchard Avi D. Goodman Joseph J. Crisco Julia A. Katarincic 《Journal of hand therapy》2019,32(1):80-85
Study Design
Basic research (biomechanics).Introduction
The high degree of motion that occurs at the thumb metacarpophalangeal (MCP) joint must be taken into account when immobilizing a partially torn or repaired thumb ulnar collateral ligament.Purpose of the Study
To determine the efficacy of a radial-based thumb MCP-stabilizing orthosis in resisting abduction across the thumb ulnar collateral ligament.Methods
Ten fresh cadaveric hands were mounted to a custom board. An anteroposterior radiograph of the thumb was obtained with a 2 N preload valgus force applied to the thumb, and the angle between the Kirschner wires was measured as a baseline. Subsequently, 20, 40, 60, 80, and 100 N valgus forces were applied 15 mm distal to the MCP joint. Anteroposterior radiographs of the thumb were obtained after each force was applied. The angle of displacement between the wires was measured and compared with the baseline angle. The angles were measured with an imaging processing tool. A custom radial-based thumb MCP-stabilizing orthosis was fashioned for each cadaveric thumb by a certified hand therapist. The aforementioned loading protocol was then repeated.Results
The radial-based thumb MCP-stabilizing orthosis significantly reduced mean abduction angles at each applied load.Discussion
We found that our orthosis, despite being hand-based and leaving the thumb IP and CMC joints free, significantly reduced mean abduction angles at each applied load.Conclusions
This investigation provides objective evidence that our radial-based thumb MCP-stabilizing orthosis effectively reduces the degree of abduction that occurs at the thumb MCP joint up to at least 100 N.Level of Evidence
n/a (cadaveric). 相似文献16.
Study Design
Clinical measurement (reliability and validity) study.Introduction
Forearm supination is important in many daily activities and is thus measured by therapists and researchers usually with a universal goniometer. DrGoniometer, a SmartPhone application, has been validated for other joint angles in the body.Purpose of the Study
To establish the reliability and validity of DrGoniometer (CDM S.r.L, Cagliari, Italy) for measuring forearm supination in healthy populations and those with forearm fractures.Methods
Participants had sustained a distal radius fracture that was treated non-surgically. Forearm supination of the participant’s fractured (n = 30) and healthy forearm (n = 30) was measured using DrGoniometer and the universal goniometer by two assessors. The assessors were blinded to each other’s measurements and their own previous measurements. Reliability was established by calculating Intra-class Correlation Coefficients, standard error of measurement and minimal detectable change. The validity of DrGoniometer was established against the universal goniometer using Pearson’s correlation co-efficient.Results
Intra-rater reliability of both DrGoniometer and the universal goniometer was high for both fractured and healthy forearms (ICCs ranged from 0.74-0.88). Inter-rater reliability of both DrGoniometer and the universal goniometer was also high in the fractured forearm group (0.76 and 0.72 respectively), but low in the healthy forearm group (0.34 and 0.42 respectively). Correlation between the tools was excellent across the fractured and healthy forearm groups (0.94 and 0.93 respectively).Discussion
Both goniometers demonstrated good-to-excellent intrarater and iner-rater reliability except in the healthy forearm group where both goniometers demonstrated poor inter-rater reliability which could be due to assessor instructions. The speed the photo can be taken and the digital record obtained are valuable aspects of DrGoniometer.Conclusion
DrGoniometer is a valid, alternate tool for measuring forearm supination. 相似文献17.
Study Design
Two-group randomized controlled trial.Introduction
Upper limb orthoses worn during functional tasks are commonly used in pediatric neurologic rehabilitation, despite a paucity of high-level evidence.Purpose of the Study
The purpose of this study was to investigate if a customized functional wrist orthosis, when placed on the limb, leads to an immediate improvement in hand function for children with cerebral palsy or brain injury.Methods
A 2-group randomized controlled trial involving 30 children was conducted. Participants were randomized to either receive a customized functional wrist orthosis (experimental, n = 15) or not receive an orthosis (control, n = 15). The box and blocks test was administered at baseline and repeated 1 hour after experimental intervention, with the orthosis on if randomized to the orthotic group.Results
After intervention, there were no significant differences on the box and blocks test between the orthotic group (mean, 10.13; standard deviation, 11.476) and the no orthotic group (mean, 14.07; standard deviation, 11.106; t[28], ?0.954; P = .348; and 95% confidence interval, ?12.380 to 4.513).Discussion
In contrast to the findings of previous studies, our results suggest that a functional wrist orthosis, when supporting the joint in a ‘typical’ position, may not lead to an immediate improvement in hand function.Conclusions
Wearing a functional wrist orthosis did not lead to an immediate improvement in the ability of children with cerebral palsy or brain injury to grasp and release. Further research is needed combining upper limb orthoses with task-specific training and measuring outcomes over the medium to long term. 相似文献18.
Michihiro Osumi Masahiko Sumitani Hiroaki Abe Yuko Otake Shin-ichiro Kumagaya Shu Morioka 《Journal of hand therapy》2019,32(1):41-47
Introduction
Chemotherapy-induced peripheral neuropathy (CIPN) usually affects both sensory and motor function of hands and feet, resulting in impaired skilled hand function (e.g., typing a keyboard). However, quantitative and objective evaluations for this condition have not been established.Purpose of the Study
We evaluated skilled hand function using a kinematic analysis and investigated relationships among hand kinematic function and the clinical sensory and motor features of CIPN.Study Designs
Clinical measurement.Methods
Twelve CIPN patients and 12 age-matched control participants were enrolled. We recorded their reach and grasp movements using a three-dimensional measurement system, and calculated the normalized jerk of these movements as quantitative indexes of skilled hand function. Additionally, we used the number of sequential hand grip–release cycles in 10 seconds as an evaluation of clinical motor function.Results
Our kinematic analyses revealed significant difference in normalized jerk of grasp movement (CIPN: 3.7 ± 0.2, control: 3.4 ± 0.1; P = .005), but this was not the case for reach movement (CIPN: 2.5 ± 0.1, control: 2.5 ± 0.2; P = .43), indicating that the distal part of the forearm is particularly affected in CIPN. Such disturbed grasp movement was directly correlated with poor scores on the hand grip–release test and the sensory tests.Discussion
We revealed deficit impaired hand function objectively and quantitatively in CIPN patients using a kinematic analysis. Further, the hand grip test could represent such kinematic abnormality and could be useful for evaluating skilled hand function of CIPN patients.Conclusions
Our kinematic and clinical measurements objectively and quantitatively evaluate skilled hand function in individuals with CIPN in clinical settings.Level of Evidence
Cross-sectional observational study. 相似文献19.
Tomoko Mizota Nicholas E. Anton Dimitrios Stefanidis 《American journal of surgery》2019,217(2):222-227
Background
This study aimed to identify differences in pattern recognition skill among individuals with varying surgical experience.Methods
Participants reviewed laparoscopic cholecystectomy videos of various difficulty, and paused them when the cystic duct or artery was identified to outline each structure on the monitor. Time taken to identify each structure, accuracy and work load, which was assessed using the NASA-Task Load Index (TLX), were compared among the three groups.Results
Ten students, ten residents and eight attendings participated in the study. Attendings identified the cystic duct and artery significantly faster and more accurately than students, and identified the cystic artery faster than residents. The NASA-TLX score of attendings was significantly lower than that of students and residents.Conclusions
Attendings identified anatomical structures faster, more accurately, and with less effort than students or residents. This platform may be valuable for the assessment and teaching of pattern recognition skill to novice surgeons.Short summary
Accurate anatomical recognition is paramount to proceeding safely in surgery. The assessment platform used in this study differentiated recognition skill among individuals with varing surgical experience. 相似文献20.
Patrick T. Hangge William W. Sheaffer Matthew Neville Nabil Wasif Richard J. Gray Barbara A. Pockaj Chee-Chee H. Stucky 《American journal of surgery》2019,217(1):78-82