首页 | 官方网站   微博 | 高级检索  
相似文献
 共查询到18条相似文献,搜索用时 900 毫秒
1.
目的量化评估16层螺旋CT冠状动脉各分支图像质量,探讨冠状动脉CT成像的临床应用效果。方法采用16层螺旋CT对102例患者行回顾性心电门控冠状动脉成像,男60例,女42例,平均年龄(57.8±9.4)岁,平均心率(62.8±10.2)次/min。心率〈60次/min(n=40)为I组,60~70次/min(n=35)为Ⅱ组,〉70次/min(n=27)为Ⅲ组。4条冠状动脉分支(左主干、左前降支、左回旋支、右冠状动脉)分别用于图像质量分析。扫描原始数据以间隔10%在20%~80%时相分别回顾性重建冠状动脉图像,用横断面、曲面重建、容积再现等方法对冠状动脉显示率评估。用曲面重建方法测量冠状动脉各分支长度及近段和远段对比噪声比。结果①冠状动脉各分支平均显示长度:左主干(10.9±3.0)mm,左前降支(130.3±29.7)mm,左回旋支(82.8±19.8)mm,右冠状动脉(150.5±27.5)mm;②Ⅰ组60%和70%为最佳时相图像质量优,Ⅱ组60%时相为最佳时相图像质量优,Ⅲ组RCA较优的时相为40%,LM、LAD、LCX较优时相为60%。③所有冠状动脉分支平均对比噪声比10.9±3.2。结论16层螺旋CT有较好质量的冠状动脉图像,心率和时相影响冠状动脉的成像质量。  相似文献   

2.
赵静  蔡永兰 《医学信息》2008,21(3):368-371
目的 探讨八排螺旋CT冠状动脉造影三维重建技术在临床上的应用.方法 25例患者均行螺旋CT冠状动脉造影成像,心率均在60-75次/分进行多层面螺旋CT扫描在心动周期R-R间期的75%的心电相位上进行横断面重建.然后采集的 数据行最大密度投影MIP、客积重建技术VR、多平面重建MPR、内窥镜、曲面重建,观察其对冠状动脉病变的显示.结果 25例患者显示左冠状动脉主干100%,左前降支、回旋支、右冠状动脉近段均清楚显示,其中11例冠状动脉内支架手术后:前降支5例、回旋支3例、前降支回旋支各一例、右冠状动脉2例,在MIP、VR、MPR上均能显示支架的位置和形态:8例显示冠状动脉狭窄:其中左前降支呈阶段性狭窄4例、回旋支狭窄2例、右冠状动脉2例、对8例冠状动脉CT成像提示有狭窄的患者进行了有创冠状动脉造影DSA检查,显示冠状动脉狭窄程度与三维成像均相对应;2例搭桥手术后吻合口通常:3例冠脉平扫显示钙化而造影后三维成像均未引起狭窄;1例扫描失败,由于心率不齐无法扫描.结论 25例冠状动脉造影经三维重建技术不仅显示冠状动脉的钙化、狭窄、斑块,而且还能观查桥血管是否通常,支架位置形态,远端血管的情况.与有创冠状动脉相比较.安全、快捷且经济,X射线少,是进行手术后评价的一种非创伤性检查方法 ,也是一种重要无创筛查手段.越来越多的被患者和临床医生接受.  相似文献   

3.
目的:探讨双源CT(DSCT)冠脉成像在冠状动脉畸形(CAA)诊断中的价值。方法:回顾分析357例经DSCT冠脉成像检出的冠状动脉畸形患者的MPR、VR、MIP及CPR图像,其中31例患者的图像与常规冠状动脉血管造影(CAG)进行对照。结果:DSCT冠脉成像检出的357例冠状动脉畸形中,冠状动脉起源异常37例,包括冠状动脉高位起源15例,冠状动脉起源于对侧冠状窦13例,回旋支起自左冠状窦7例,回旋支起自右冠状窦1例,单一冠状动脉1例;本组冠状动脉走行异常均表现为心肌桥(MB),其发现MB319例326处;冠状动脉终止异常中冠状动脉瘘1例。其中31例于DSCT冠脉造影后行CAG检查,DSCT冠脉成像检出27例29处MB者CAG仅检出21例22处,但3例冠状动脉起源异常及1例冠状动脉瘘行CAG全部检出。结论:DSCT冠脉成像能清晰地显示各种冠状动脉畸形,为术前评估及预后判断提供重要信息,亦可作为随诊复查的可靠方法。  相似文献   

4.
张畅 《医学信息》2018,(17):101-103
目的 探讨冠状动脉介入治疗老年急性心肌梗死并心源性休克的临床价值。方法 回顾性分析2013年7月~2017年11月在我院接受治疗的155例老年急性心肌梗死并心源性休克患者的临床资料,根据治疗方式分为溶栓组(80例)与介入治疗组(75例)。比较两组患者尿量、心率、左心室射血分数(LVEF)以及血管开通率。结果 治疗后,介入组尿量多于溶栓组,HR值低于溶栓组,差异有统计学意义(P<0.05);住院前及出院6个月后,介入组LVEF值均高于溶栓组,差异有统计学意义(P<0.05);溶栓组出院6个月后,LVEF值高于出院前,差异有统计学意义(P<0.05);介入组出院前后LVEF值对比,差异无统计学意义(P>0.05);介入组血管开通率为93.33%,高于溶栓组的77.50%,差异有统计学意义(P<0.05)。结论 冠状动脉介入为治疗老年急性心肌梗死并心源性休克患者的有效手段,可有效改善血液流变学、尿量,利于心功能恢复。  相似文献   

5.
背景:传统的CT在冠心病介入治疗后随访中难以普及,寻找无创、有效的检查方法对支架内再狭窄的评价就成了影像科医生非常关心的课题。 目的:通过在不控制心率下双源CT冠状动脉成像与选择性冠状动脉造影对支架评估的对比,探讨双源CT冠状动脉成像对冠状动脉支架内再狭窄的诊断价值。 方法:收集53例患者共75枚支架在不控制心率情况下同期行双源CT冠状动脉成像及冠状动脉造影检查的患者影像资料,分析双源CT冠状动脉成像诊断支架内再狭窄的敏感性等各项指标。 结果与结论:①双源CT冠状动脉成像能清楚显示全部支架,96%(72/75)支架图像达到良好以上。②双源CT冠状动脉成像对支架内再狭窄诊断的敏感性、特异性、阳性预测值、阴性预测值及准确性,与冠状动脉造影结果比较差异无显著性意义(P > 0.05)。③双源CT冠状动脉成像分别对心率< 70次/min和≥70次/min的患者支架再狭窄检测的敏感性、特异性、阳性预测值、阴性预测值、准确性比较差异无显著性意义 (P > 0. 05 )。④双源CT冠状动脉成像对直径< 3.0 mm支架再狭窄检测的敏感性、特异性、阳性预测值、阴性预测值、准确性低于≥3.0 mm的支架再狭窄(P < 0. 05 )。结果说明,双源CT冠状动脉成像对诊断冠状动脉支架内再狭窄具有较高的应用价值,且不受心率的影响,可作为大直径支架通畅情况的评估方式及小直径支架的初步筛查方法。  相似文献   

6.
多层螺旋CT冠状动脉造影初步探讨   总被引:9,自引:0,他引:9  
目的探讨多层螺旋CT冠状动脉造影的可行性及不同心率下冠状动脉的显示能力.方法16例多层螺旋CT冠状动脉造影.东芝AQUILION多层螺旋CT采集原始数据,扫描速度0.32s/270°,层厚2mm,螺距1.0-1.2.对比剂安射力2ml/kg,注射速率3.5ml/s.延迟时间20s,SGI02图像后处理工作站,后处理软件为ALATOVIEW版本Version1.42;采用遮盖容积重建(SVR)、多平面重建(MPR)、曲面重建(CPR)后处理技术.结果心率<60次/min时冠状动脉主干及主要分支(前降支、回旋支)显示最清晰,心率60~79次/min时冠状动脉主干及主要分支显示较清晰,心率>80次/min时冠状动脉主要分支显示不清.结论一定心率及扫描参数、对比剂使用合适前提下,多层螺旋CT冠状动脉造影可获得满意的冠状动脉主干及主要分支图像.  相似文献   

7.
目的 探讨等中心扫描对降低冠状动脉多层螺旋CT血管成像(MSCTA)辐射剂量的价值。方法 采用前瞻性随机对照研究方法。纳入广东省中医院珠海医院2016年11月—2018年4月144例行冠状动脉MSCTA检查患者,将患者按随机区组法分为A、B、C、D 4组,每组36例。A组采用常规扫描定位,电流为智能毫安;B、C、D组采用等中心位置扫描,电流分别为智能毫安、智能毫安的90%、智能毫安的80%。4组扫描管电压均为120 kV。比较4组患者冠状动脉MSCTA图像的客观图像质量噪声、信噪比(SNR),主观质量评分比及辐射剂量(ED),对直径>1.5 mm的血管节段采用冠状动脉15分段法评分,用以评价主观图像质量。客观噪声方面,4组重建图像中的主支气管选择,感兴趣区(面积约15.0 mm2),测量其标准差值作为噪声值,SNR为其CT值/标准差。结果 MSCTA图像分析显示,以D、A、C、B组为序,噪声依次降低(分别为15.09±2.97、2.68±2.47、2.57±2.29和2.45±4.36),SNR依次升高(分别为63.74±19.78、78.64±14.66、78.66±14.84和79.66±22.90);D组与A、B、C组两两比较,噪声高而SNR低,差异均有统计学意义(P值均<0.05);A、B、C组间噪声及SNR两两比较,差异均无统计学意义(P值均>0.05)。4组冠状动脉图像质量主观评分优良率98.9%(1 939/1 960),4组间比较差异均无统计学意义(P值均>0.05);A、B、C、D辐射剂量依次降低,分别为(3.39±1.39)mSv、(2.89±1.21)mSv、(2.56±1.05)mSv,(2.14±0.87)mSv,其中A组明显高于C、D组,B组高于D组,差异均有统计学意义(P值均<0.05)。结论 在不降低冠状动脉成像质量的情况下,等中心扫描能降低冠状动脉MSCTA的辐射剂量。  相似文献   

8.
目的:探讨多模型迭代重建(ASIR-V)在CT门静脉成像(CTPV)中改善图像质量的应用价值。方法:收集Revolution CT检查CTPV患者60例并随机分为A、B组。两组均采用管电压120 kV、噪声指数10、对比剂用量450 mgI/kg。扫描结束后,A组采用40%ASIR,B组采用40%ASIR-V。分别测量门静脉主干、门静脉左支、门静脉右支的CT值和CT值标准差,并计算信噪比和对比噪声比。记录两组患者CT容积剂量指数(CTDIVOL)、剂量长度乘积(DLP),并计算有效辐射剂量(ED)。由两名有经验放射科医师采用5分法标准对图像质量进行双盲法主观评分。结果:两组患者一般资料、辐射剂量(CTDIVOL、DLP、ED)和对比剂总量间差异无统计学意义(P>0.05)。两组门静脉主干、门静脉左支及右支CT值均无统计学差异(P>0.05)。A组门静脉主干、门静脉左支及右支CT值的标准差高于B组,A组信噪比和对比噪声比低于B组,且差异均具有统计学意义(P<0.05)。两名医师对两组图像主观评分具有很好的一致性(Kappa值>0.75, P<0.05),B组图像主观评分显著高于A组(P<0.05)。结论:ASIR-V可以显著提高门静脉图像质量,为临床诊断提供更好的CTPV图像。  相似文献   

9.
王江凤    高美华  张娟 《医学信息》2019,(12):64-66
目的 探究冠状动脉粥样硬化患者外周血Th17细胞与IL-17水平变化的意义。方法 收集青岛阜外心血管病医院冠状动脉粥样硬化患者200例,根据疾病类型分为心肌梗死(AMI)组(52例)、不稳定型心绞痛(UA)组(68例)、稳定型心绞痛(SA)组(80例),另外选取同期200例体检者作为对照组。采用流式细胞术检测患者Th17细胞频率,ELISA法检测各组血清中IL-17、CRP表达水平。结果 流式细胞检测结果显示,与对照组比较,各组Th17细胞的频率表达均升高,差异具有统计学意义(P<0.05),且AMI组升高水平高于SA组和UA组,差异具有统计学意义(P<0.05); ELISA检测结果显示,与对照组比较,各组IL-17及CRP表达水平均升高,差异具有统计学意义(P<0.05),且AMI组升高水平高于SA组和UA组,差异具有统计学意义(P<0.05)。结论 冠状动脉粥样硬化患者血中Th17及IL-17水平的升高,可能是导致冠状动脉粥样硬化患者板块不稳定的原因。  相似文献   

10.
陈珊 《医学信息》2018,(24):126-127
目的 探讨心电图检查与冠状动脉造影检查在冠心病患者中的诊断价值。方法 选取2016年10月~2018年10月于九江市柴桑区人民医院住院的疑似冠心病患者110例,所有患者行常规心电图和冠状动脉造影检查,比较心电图检查结果和冠状动脉造影结果。结果 ①ST-T改变在心电图中诊断率为65.45%,高于冠状动脉造影检查的60.91%,二者比较,差异无统计学意义(P>0.05);②冠状动脉造影检查确诊冠心病患者67例。其中ST-T改变诊断率为58.21%,高于非ST-T改变的41.79%,ST-T改变在确诊冠心病方面优于非ST-T改变,差异具有统计学意义(P<0.05)。结论 冠状动脉造影检查仍是临床确诊冠心病的首选方法,心电图ST-T改变能够为早期冠心病诊断方面提供依据,临床确诊还需结合冠状动脉造影等相关检查。  相似文献   

11.
We report a rare case of coronary anastomoses in an 83‐year‐old male cadaveric heart. Anomalous vessels arose from the right sinus of the aorta, left main coronary artery, left anterior descending artery, left anterior medial atrial artery, and left subclavian artery. These vessels bifurcated and anastomosed, and finally connected to the pulmonary trunk. The present case is categorized as a multilateral coronary artery fistula in cardiology. Clin. Anat. 25:969–972, 2012. © 2012 Wiley Periodicals, Inc.  相似文献   

12.
The association between coronary arterial dominance patterns and the coronary artery diameter, length, and valvular heart diseases were previously studied. However, its association with coronary artery disease (CAD) is unclear. We investigated to determine whether the extent and localization of CAD differ in right, left, or codominant coronary arterial patterns. Twelve thousand five hundred fifty-eight patients admitted to Tehran Heart Center for coronary angiography were studied retrospectively (2004-2006). The extent and localization of CAD and the dominant artery were determined. There were 62.7% males. The mean age was 57.6 +/- 10.3. 84.2% [95% confidence interval (CI); 83.6-84.8%], 10.9% (95% CI; 10.4-11.4%), and 4.8% (95% CI; 4.4-5.2%) of the patients were right, left, and codominant, respectively; No significant difference considering age, sex, positive family history, hypertension, hyperlipidemia, electrocardiography, exercise treadmill stress test, and perfusion scan were seen in the groups. The right-dominant patients tend to have three-vessel disease (33.1% vs. 27%, P < 0.0001), stenosis of more than 50% in right coronary artery (65.9% vs. 57.9%, P < 0.0001) and left circumflex territories (64% vs. 59.4%, P = 0.01), more than the left-dominant patients. The involvements of the left main coronary artery, left anterior descending artery territory, and posterior descending artery were not significantly different. This study demonstrates a relationship between angiographic CAD severity, and the involved arterial territory and dominancy patterns.  相似文献   

13.
目的探讨实时三维超声心动图(RT-3DE)测量左心室重构指数(LVRI)评价冠心病患者左心室重构的价值。方法根据冠状动脉造影结果,将病变组分为左旋支或/和右冠支病变组(LCX/RCA组)24例,其中男性18例,女性6例,年龄38~76岁,平均年龄54.2岁;单纯左前降支病变组(LAD组)21例,其中男性16例,女性5例,年龄35~78岁,平均年龄53.5岁;包含LAD病变的双支或多支病变组(多支组)27例,其中男性20例,女性7例,年龄39~80岁,平均年龄56.2岁;正常对照组22例,其中男性17例,女性5例,年龄32~79岁,平均年龄55.2岁。行RT-3DE,应用软件自动测量左心室舒张末期容积(LVEDV)、舒张末期心外膜容积(LVEDVepi)、左心室射血分数(LVEF);再计算左心室质量[LVM=1.05×(LVEDVepi-LVEDV)]、LVRI(LVM/LVEDV),并采用二维超声心动图(2DE)双平面Simpson测量并计算上述各值。比较RT-3DE和2DE测量LVRI在组间的差异、组内的差异和相关性,以及LVRI与LVEDV、LVEF的相关性;并比较观察者间及观察者内两种方法测量LVRI的一致性和重复性。结果正常对照组、LCX/RCA组、LAD组、多支组两种方法测量的LVRI呈显著递减(P〈0.05或P〈0.01)。前两组两种方法间的LVRI差异无统计学意义(P〉0.05),后两组有统计学意义(P〈0.05或P〈0.01)。相关性分析表明:①除多支组内两种方法间的LVRI无显著相关性(P〉0.05)外,余3组内均呈显著相关性(P〈0.01);②病变组同种方法测量的LVRI与LVEDV呈显著负相关性、LVEF呈显著正相关性(P〈0.01),但正常组内无显著相关性(P〉0.05)。RT-3DE测量的LVRI观察者间及观察者内一致性和重复性较2DE好。结论来源于RT-3DE的LVRI优于2DE,更能作为临床评价冠心病患者左心室重构的指标。  相似文献   

14.
目的比较两种不同方法构建不停跳冠状动脉搭桥动物模型,探讨模型构建方法的可行性和优劣性。方法家犬20只随机分为头臂干组和降主动脉组,以小口径异种血管为桥血管。左侧第4肋间切口入胸,先行头臂干动脉或降主动脉端血管吻合,再行冠状动脉端血管吻合,术毕结扎左冠状动脉前降支近端。结果 2组犬均无术中死亡。头臂干组和降主动脉组主动脉端血管吻合用时分别为(33.9±4.8)min和(29.6±3.5)min(P0.05),冠状动脉端血管吻合用时分别为(28.5±3.0)min和(28.1±2.3)min(P0.05),2组术中出血量分别为(77.5±16.2)mL和(66.5±12.3)mL(P0.05)。降主动脉组术中侧壁钳夹降主动脉后股动脉血压明显降低,术后2只犬出现黑便。结论将小口径异种血管吻合在头臂干动脉或降主动脉均可成功构建犬不停跳冠状动脉搭桥模型;降主动脉组股动脉血压波动大,存在腹腔脏器缺血再灌注损伤;头臂干组血管吻合用时稍长,但术中股动脉血压波动小,模型构建相对更安全。  相似文献   

15.
目的分析小儿起源于肺动脉的左冠状动脉异常矫治手术的麻醉特点,为今后开展类似手术提供可行的麻醉管理方法。方法回顾性分析2006年3月至2010年7月本院20例小儿起源于肺动脉的左冠状动脉异常矫治术的麻醉管理方法。结果采用静吸复合全麻,术中均未出现急性心衰或心梗,CPB时间为58~204(80.6±44.4)min,主动脉阻断时间为25~125(53.4±32.2)min,开放主动脉后均自动复跳,适时应用血管活性药物,以保证麻醉平稳,停CPB时SBP为(78.6±8.0)mmHg,DBP为(45.4±3.5)mmHg,HR为(130.8±10.5)次/min,术中无死亡及麻醉并发症。1例术后第2天死于严重低心排综合征,死亡率为5%,其余痊愈出院。结论小儿左冠状动脉异常矫治术以静吸复合全麻的方法 ,辅以严密监测,尽力维持血流动力学稳定,积极采取各种措施避免加重心肌缺血的麻醉管理方法是正确可行的,可以推广应用于术前有心功能损害的手术。  相似文献   

16.
Continuous measurement of coronary artery diameter in situ   总被引:2,自引:0,他引:2  
The diameter of the coronary artery was measured in dogs in situ by an ultrasonic dimension gauge using 10-MHz piezoelectric crystals. Underestimation in measurements due to crystal rotation was limited to < 1% by adding a convex lens to the crystal. A pair of small 10- and 5-MHz crystals were sutured to the adventitia of the left circumflex coronary artery (LCX) and the descending aorta (Ao), respectively. Using cuff occluders for vessel constriction of the inferior vena cava (IVC) or the Ao, curvilinear relationships between pressure and diameters were obtained. Phasic changes of the aortic as well as coronary diameter were grossly similar to changes in the pressure wave. After intravenous administration of dipyridamole, aortic pressure (AP) decreased by 17% along with 3% decline of the Ao and LCX diameter, however, after nitroglycerin given by the same route, LCX diameter increased by 5% (P < 0.05) despite 16% and 2.3% reductions in AP and Ao diameter, respectively. This ultrasonic technique, which allows continuous measurement of the diameter of small vessels, should provide a new tool for the study of coronary circulation.  相似文献   

17.
目的:比较冠脉CT与冠脉造影诊断心肌桥的临床价值。方法:收集2015年7月~2020年7月苏州大学第二附属医院心内科收治的107例疑似冠心病患者临床资料。依次进行冠脉CT和冠脉造影检查,计算壁冠状动脉(MCA)狭窄程度,观察前降支、对角支、钝缘支、后降支和回旋支冠脉分布走行以及与心肌的关系,测量心肌桥长度和厚度。比较两种检查方法图像质量优良率、心肌桥检出率以及心肌桥测量指标。分析两种检查方法显示MCA狭窄程度和诊断心肌桥的一致性。以冠脉造影为金标准,计算敏感度、特异度、准确度、阳性预测值、阴性预测值,评估冠脉CT判断MCA中重度狭窄和诊断心肌桥的价值。结果:两种检查方法图像质量优良率均较好,冠脉CT心肌桥检出率显著高于冠脉造影(25.23% vs 14.02%, P<0.05);冠脉CT测得心肌桥长度大于冠脉造影,MCA狭窄程度低于冠脉造影,差异具有统计学意义(P<0.05);冠脉CT和冠脉造影显示MCA狭窄程度的一致性较好(Kappa=0.832, P<0.05);与冠脉造影比较,冠脉CT判断MCA中重度狭窄的敏感度、特异度、准确度、阳性预测值、阴性预测值分别为90.63%、86.67%、74.36%、95.59%、87.85%;冠脉CT和冠脉造影诊断心肌桥的一致性较好(Kappa=0.815, P<0.05);与冠脉造影比较,冠脉CT诊断心肌桥的敏感度、特异度、准确度、阳性预测值、阴性预测值分别为64.29%、73.33%、69.23%、68.75%、68.97%。结论:冠脉CT与冠脉造影对心肌桥诊断均具有一定价值,而冠脉CT具有无创性、图像质量优良率高,且对心肌桥位置及分布显示佳,并对MCA狭窄具有较高敏感度和特异度,更具临床应用优势。  相似文献   

18.
目的:探讨心率变异性指标与冠心病患者冠脉病变程度的关系。方法:选取冠心病患者84例(观察组),同时选取健康志愿者90例作为对照组,均给予24 h动态心电图监测。结果:观察组NN间期的标准差(SDNN)、RR间期的均值标准差(SDANN)、相邻RR间期差值的均方根(RMSSD)、相邻RR间期差值>50 ms的心搏数所占百分比(PMN50)和高频功率(HF)分别为(95.54±20.12) ms、(94.48±21.15) ms、(29.84±10.06) ms、(7.46±2.31)%和(0.85±0.20) Hz,明显低于对照组(P<0.05),而低频功率(LF)为(137.74±21.16) Hz,明显高于对照组(P<0.05);冠状动脉病变≥3支患者SDNN、SDANN、RMSSD、PMN50和HF分别为(84.31±19.64) ms、(89.42±18.82) ms、(23.38±7.15) ms、(5.40±1.90)%和(0.70±0.21) Hz,明显低于冠状动脉病变数为1支和2支患者(P<0.05),而LF为(150.54±21.15) Hz,明显高于冠状动脉病变数为1支和2支患者(P<0.05);观察组男女患者SDNN、SDANN、RMSSD、PMN50、HF和LF比较差异无统计学意义(P>0.05);Gensini评分与SDNN、SDANN、RMSSD、PMN50、HF呈负相关(r=-0.511、-0.487、-0.543、-0.512和-0.507, P<0.05),与LF呈正相关(r=0.577, P<0.05)。结论:动态心电图在冠心病患者冠脉病变程度评价中有一定应用价值,其心率变异性指标与冠状动脉病变程度有一定关系。  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司    京ICP备09084417号-23

京公网安备 11010802026262号