首页 | 官方网站   微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
An alternative method for simultaneous baseline separation of α and β‐acids homologues and isomers in hop by CD‐MEKC with UV detection was proposed. The optimized background electrolyte was composed of 30 mmol/L sodium tetraborate solution, 45 mmol/L sodium dodecyl sulfate, 20 mmol/L β‐cyclodextrin and 10% v/v acetonitrile. The instrumental conditions were evaluated by using a 33 Box‐Benhken experimental design. In order to demonstrate the applicability of the method, 21 hop samples from different varieties were analyzed. The repeatability intra‐ and interday tests were performed and relative standard deviations lower than 7% for area and migration times were observed. The present method comprehended 8 min analysis time and revealed to be faster and more efficient when compared to previous reports from literature.  相似文献   

2.
3.
We report the development and validation of a stability‐indicating reversed‐phase high‐performance liquid chromatography method with precolumn derivatization for the separation and identification of the impurities of ripasudil hydrochloride hydrate, a novel protein kinase inhibitor. 2,3,4,6‐Tetra‐O‐acetyl‐β‐d ‐glucopyranosyl isothiocyanate was chosen as the derivatizing reagent and triethylamine was added as catalyst. 200 μL sample solution (1 mg/mL), 600 μL derivatizing reagent (1 mg/mL), and 200 μL triethylamine solution (1%, v/v) were mixed and reacted at 40°C for 30 min. The separation was achieved on an Inertsil C18 ODS‐3 (250 mm × 4.6 mm, 5 μm) column using mobile phases including 10 mmol monopotassium phosphate buffer (pH 3.0) and methanol in gradient mode. The column temperature was adjusted at 25°C and the flow rate at 1 mL/min. The detection was carried out at 220 nm. Different precolumn derivatization conditions as well as the high‐performance liquid chromatography conditions were optimized. Ripasudil hydrochloride hydrate and its four impurities were detected and quantitated, among which two new compounds were characterized. The proposed method was validated and proven to be selective, accurate, and precise and suitable for the quantitative analysis of ripasudil hydrochloride hydrate.  相似文献   

4.
A fast and effective method was developed to detect domoic acid based upon microchip electrophoresis combined with laser‐induced fluorescence detection. Through study of the gated injection process on the cross channel of the microchip, the low‐voltage mode with relatively longer sample loading time was adopted to reduce the sample discrimination and improve the signal sensitivity. Fluorescein isothiocyanate was used as the derivatizing reagent for domoic acid. Under the optimized conditions, domoic acid was completely separated in 60 s with separation efficiency of 1.35 × 105 m−1. The calibration curve was obtained in the range of 1.0 × 10−9 to 1.0 × 10−7 mol/L, and the detection limit reached 2.8 × 10−10 mol/L. This developed method was successfully applied to analyze domoic acid in real samples.  相似文献   

5.
An analytical method for separation and determination of thallium species in water using high‐performance liquid chromatography with inductively coupled plasma mass spectrometry was developed. The composition and concentration of mobile phase, injection volume, and pH value were optimized respectively with an anion or cation exchange column. The results showed that Tl(I) and Tl(III) were effectively separated using anion exchange column Hamilton PRP‐X100, with the mobile phase consisting of 200 mmol/L ammonium acetate and 10 mmol/L diethylenetriaminepentaacetic acid (pH = 4.2). When using a Dionex cation exchange guard column, CS12A, 15 mmol/L HNO3, and 3 mmol/L diethylenetriaminepentaacetic acid as the mobile phase, Tl(I) and Tl(III) could be effectively separated. The detection limits of the methods were 3–6 and 9–12 ng/L, respectively. In a solution containing Fe ions and oxalic acid, a significant quantity of Tl(I) was oxidized. Fe ions and oxalic acid in the water samples did not interfere with high‐performance liquid chromatography‐inductively coupled plasma mass spectrometry measurement results.  相似文献   

6.
A new facile magnetic micro‐solid‐phase extraction coupled to gas chromatography and mass spectrometry detection was developed for the extraction and determination of selected antidepressant drugs in biological fluids using magnetite‐MCM‐41 as adsorbent. The synthesized sorbent was characterized by several spectroscopic techniques. The maximum extraction efficiency for extraction of 500 μg/L antidepressant drugs from aqueous solution was obtained with 15 mg of magnetite‐MCM‐41 at pH 12. The analyte was desorbed using 100 μL of acetonitrile prior to gas chromatography determination. This method was rapid in which the adsorption procedure was completed in 60 s. Under the optimized conditions using 15 mL of antidepressant drugs sample, the calibration curve showed good linearity in the range of 0.05–500 μg/L (r 2 = 0.996–0.999). Good limits of detection (0.008–0.010 μg/L) were obtained for the analytes with good relative standard deviations of <8.0% (n  = 5) for the determination of 0.1, 5.0, and 500.0 μg/L of antidepressant drugs. This method was successfully applied to the determination of amitriptyline and chlorpromazine in plasma and urine samples. The recoveries of spiked plasma and urine samples were in the range of 86.1–115.4%. Results indicate that magnetite micro‐solid‐phase extraction with gas chromatography and mass spectrometry is a convenient, fast, and economical method for the extraction and determination of amitriptyline and chlorpromazine in biological samples.  相似文献   

7.
A pressure‐assisted CEC with ESI‐MS based on poly(1‐hexadecene‐co‐trimethylolpropane trimethacrylate) monolithic column for rapid analysis of two β2‐agonists and three narcotics was established in this article. After the organic polymer‐based monolithic column was prepared by an in‐situ polymerization procedure, a systematic investigation of the pressure‐assisted CEC separation and ESI‐MS detection parameters was performed. Baseline separation of the studied analytes could be obtained using the solution containing 75% ACN v/v and 20 mmol/L ammonium acetate with pH 8.0 as running buffer, when applying separation voltage of 20 kV and assisted pressure of 5 bar. Under the optimized conditions, two β2‐agonists and three narcotics could be completely resolved and accurately determined within 15 min. Finally, the proposed method was successfully used for real urine samples detection.  相似文献   

8.
For the first time, the low‐density solvent‐based vortex‐assisted surfactant‐enhanced emulsification liquid–liquid microextraction, followed by GC‐flame photometric detection has been developed for the determination of eight organophosphorus pesticides in aqueous samples. A small volume of organic extraction solvent (toluene) was dispersed into the aqueous samples by the assistance of surfactant and vortex agitator. The extraction was performed in a special disposable polyethylene pipette, allowing using the reagents with lower density than water as extraction solvents. The influence parameters were systemically investigated and optimized: toluene (30 μL) and Triton X‐100 (0.2 mmol/L) were used as the extraction solvent and the surfactant, respectively, and the extraction was performed for 1 min under room temperature without adding sodium chloride. Under the optimum conditions, the validation parameters such as the RSD (n = 6; 2.1–11.3%), LOD (0.005 and 0.05 μg/L), and linear range (0.1–50.0 μg/L with correlation coefficients (0.9958–0.9992) showed the method was satisfying. The proposed method has been successfully applied to the determination of the organophosphorus pesticides in real samples with recoveries between 82.8 and 100.2%.  相似文献   

9.
A method based on ultrasound‐assisted liquid–liquid extraction and high‐performance liquid chromatography has been optimized for the determination of six polybrominated diphenyl ether congeners. The optimal condition relevant to the extraction was first investigated, more than 98.7 ± 0.7% recovery was achieved with dichloromethane as extractant, 5 min extraction time, and three cycles of ultrasound‐assisted liquid–liquid extraction. Then multiple function was employed to optimize polybrominated diphenyl ether detection conditions with overall resolution and chromatography signal area as the responses. The condition chosen in this experiment was methanol/water 93:7 v/v, flow rate 0.80 mL/min, column temperature 30.0°C. The optimized technique revealed good linearity (R2 > 0.9962 over a concentration range of 1–100 μg/L) and repeatability (relative standard deviation < 6.3%). Furthermore, the detection limit (S/N = 3) of the method were ranged from 0.02 to 0.13 μg/L and the quantification limit (S/N = 10) ranged from 0.07 to 0.35 μg/L. Finally, the proposed method was applied to spiked samples and satisfactory results were achieved. These results indicate that ultrasound‐assisted liquid–liquid extraction coupled with high‐performance liquid chromatography was effective to identify and quantify the complex polybrominated diphenyl ethers in effluent samples.  相似文献   

10.
In the current study, a novel technique for extraction and determination of trans,trans‐muconic acid, hippuric acid, and mandelic acid was developed by means of ion‐pair‐based hollow fiber liquid‐phase microextraction in the three‐phase mode. Important factors affecting the extraction efficiency of the method were investigated and optimized. These metabolites were extracted from 10 mL of the source phase into a supported liquid membrane containing 1‐octanol and 10% w/v of Aliquat 336 as the ionic carrier followed by high‐performance liquid chromatography analysis. The organic phase immobilized in the pores of a hollow fiber was back‐extracted into 24 μL of a solution containing 3.0 mol/L sodium chloride placed inside the lumen of the fiber. A very high preconcentration of 212‐ to 440‐fold, limit of detection of 0.1–7 μg/L, and relative recovery of 87–95% were obtained under the optimized conditions of this method. The relative standard deviation values for within‐day and between‐day precisions were calculated at 2.9–8.5 and 4.3–11.2%, respectively. The method was successfully applied to urine samples from volunteers at different work environments. The results demonstrated that the method can be used as a sensitive and effective technique for the determination of the metabolites in urine.  相似文献   

11.
《Electrophoresis》2018,39(17):2195-2201
A sensitive, fast, and effective method, field‐amplified sample stacking (FASS) in capillary electrophoresis, has been established for the separation and determination of corynoxine and corynoxine B. Hydroxypropyl‐β‐CD (HP‐β‐CD) and tetrabutylammonium‐L‐glutamic acid (TBA‐L‐Glu) were used as additives in the separation system. Electrokinetic injection was chosen to introduce sample from inlet at 10 kV for 50 s after a water plug (0.5 psi, 4 s) was injected to permit FASS. The running buffer (pH 6.1) was composed of 40 mM sodium dihydrogen phosphate solution, 130 mM HP‐β‐CD, and 10 mM TBA‐L‐Glu and the separation voltage was 20 kV. Under the optimum conditions, corynoxine and corynoxine B were successfully enriched and separated within 12 min and the sensitivity was improved approximately by 700–900 folds. Calibration curves were in a good linear relationship within the range of 62.5–5.00 × 103 ng/mL for both corynoxine and corynoxine B. The limits of detection (S/N = 3) and quantitation (S/N = 10) were 14.9, 45.2 ng/mL for corynoxine and 11.2, 34.5 ng/mL for corynoxine B, respectively. Finally, this method was successfully applied for the determination of corynoxine and corynoxine B in the stems with hooks of Uncaria rhynchophylla and its formulations.  相似文献   

12.
We describe the preparation, characterization, and application of a composite film adsorbent based on blended agarose‐chitosan‐multiwalled carbon nanotubes for the preconcentration of selected nonsteroidal anti‐inflammatory drugs in aqueous samples before determination by high performance liquid chromatography with ultraviolet detection. The composite film showed a high surface area (4.0258 m2/g) and strong hydrogen bonding between the multiwalled carbon nanotubes and agarose/chitosan matrix, which prevent adsorbent deactivation and ensure long‐term stability. Several parameters, such as sample pH, addition of salt, extraction time, desorption solvent, and concentration of multiwalled carbon nanotubes in the composite film were optimized using a one‐factor‐at‐time approach. The optimum extraction conditions obtained were as follows: isopropanol as conditioning solvent, 10 mL of sample solution at pH 2, extraction time of 30 min, stirring speed of 600 rpm, 100 μL of isopropanol as desorption solvent, desorption time of 5 min under ultrasonication, and 0.4% w/v of composite film. Under the optimized conditions, the calibration curve showed good linearity in the range of 1–500 ng/mL (r2 = 0.997–0.999), and good limits of detection (0.89–8.05 ng/mL) were obtained with good relative standard deviations of < 4.59% (n = 3) for the determination of naproxen, diclofenac sodium salt, and mefenamic acid drugs.  相似文献   

13.
Malondialdehyde has been used as a biomarker for lipid peroxidation in biological samples. An ultra‐high performance liquid chromatography with tandem mass spectrometry method was developed to determine the levels of malondialdehyde in human urine and saliva samples. To select the optimum derivatization reagent from four diamino compounds, the reactivity and sensitivity of their derivatives were compared, and 3,4‐diaminobenzophenone was selected. The optimum reaction conditions for malondialdehyde with 3,4‐diaminobenzophenone were as follows: a reagent dosage of 50 mg/L, pH of 4, and reaction for 30 min at 50°C. The formed derivative product was analyzed using ultra‐high performance liquid chromatography with tandem mass spectrometry without additional extraction or concentration steps. In the optimal conditions, the method was used to determine malondialdehyde concentration in human urine and saliva samples. The limits of quantification for malondialdehyde in biological samples were over a concentration range of 0.1–0.3 μg/L. Additionally, the calibration curve showed a linearity greater than r = 0.997. The method was used to analyze 14 human urine and saliva samples from healthy volunteers. Malondialdehyde was detected in the concentration range of 1.7–33.6 μg/g creatinine in all human urine samples and 0.1–1.3 μg/L in all human saliva samples.  相似文献   

14.
A simple and reliable method was established for simultaneous determination of 4‐hydroxyphenyl acetic acid, 4‐hydroxyphenyl lactic acid, and 3,4‐hydroxyphenyl propionic acid in human urine by high‐performance liquid chromatography with fluorescence detection. Solid‐phase extraction was used to eliminate the interferences in urine. The separation of three analytes was achieved using a C18 column and a mobile phase formed by a 95:5 v/v mixture of 50 mmol/L ammonium acetate buffer at pH 6.8 that contained 5 mmol/L tetrabutyl ammonium bromide and acetonitrile. Under the optimized conditions, the detection limits of 4‐hydroxyphenyl acetic acid, 4‐hydroxyphenyl lactic acid, and 3,4‐hydroxyphenyl propionic acid were 4.8 × 10−3, 8.80 × 10−3, and 9.00 × 10−3 mg/L, respectively, and the recoveries were in the range of 85.0–120.0% with relative standard deviations of 1.5–3.1%. This method was used to analyze urine samples from breast cancer patients, healthy people and post‐surgery breast cancer patients. Significant differences in urinary levels of 4‐hydroxyphenyl acetic acid and 4‐hydroxyphenyl lactic acid could be found between the breast cancer patients group and other two groups. No effect of age and sex was observed on the urinary levels of 4‐hydroxyphenyl acetic acid and 4‐hydroxyphenyl lactic acid. This method might be helpful for cancer biomarkers discovery in urine.  相似文献   

15.
A simple, accurate, and highly sensitive method was developed for the determination of 13 carbohydrates in polysaccharide of Spirulina platensis based on high‐performance anion‐exchange chromatography coupled with pulsed amperometric detection and mass spectrometry. Samples were extracted with deionized water using ultrasonic‐assisted extraction, and the ultrasound‐assisted extraction conditions were optimized by Box–Behnken design. Then the extracted polysaccharide was hydrolyzed by adding 1 mol/L trifluoroacetic acid before determination by high‐performance anion‐exchange chromatography coupled with pulsed amperometric detection and confirmed by high‐performance anion‐exchange chromatography coupled with mass spectrometry. The high‐performance anion‐exchange chromatography coupled with pulsed amperometric detection method was performed on a CarboPac PA20 column by gradient elution using deionized water, 0.1 mol/L sodium hydroxide solution, and 0.4 mol/L sodium acetate solution. Excellent linearity was observed in the range of 0.05–10 mg/L. The average recoveries ranged from 80.7 to 121.7%. The limits of detection and limits of quantification for 13 carbohydrates were 0.02–0.10 and 0.2–1.2  μg/kg, respectively. The developed method has been successfully applied to ambient samples, and the results indicated that high‐performance anion‐exchange chromatography coupled with pulsed amperometric detection and mass spectrometry could provide a rapid and accurate method for the simultaneous determination of carbohydrates.  相似文献   

16.
A simple, rapid, sensitive, and environmentally friendly method, based on modified dispersive liquid–liquid microextraction coupled with high‐performance liquid chromatography was developed for the simultaneous determination of five biogenic amines in fermented food samples. Biogenic amines were derivatized with 9‐fluorenylmethyl chloroformate, extracted by vortex‐assisted surfactant‐enhanced emulsification liquid–liquid microextraction, and then analyzed by high‐performance liquid chromatography. Five biogenic amine compounds were separated within 30 min using a C18 column and gradient elution with acetonitrile and 1% acetic acid. Factors influencing the derivatization and extraction efficiency such as type and volume of extraction solvent, type, and concentration of surfactant, pH, salt addition, and vortex time were optimized. Under the optimum conditions, the method provided the enrichment factors in the range of 161–553. Good linearity was obtained from 0.002–0.5 mg/L for cadaverine and tyramine, 0.003–1 mg/L for tryptamine and histamine, and 0.005–1 mg/L for spermidine with coefficient of determination (R2) > 0.992. The limits of detection ranged from 0.0010 to 0.0026 mg/L. The proposed method was successfully applied to analysis of biogenic amines in fermented foods such as fermented fish (plaa‐som), wine and beer where good recoveries were obtained in the range of 83.2–112.5%  相似文献   

17.
A fast, sensitive, and centrifugeless ultrasound‐assisted emulsification microextraction followed by a high‐performance liquid chromatography method is developed for the determination of some phthalate esters in aqueous samples. In this method, a simple approach is followed to eliminate the centrifugation step in dispersive liquid–liquid microextraction using an organic solvent whose melting point is near the ambient temperature, consumption of the extracting solvent is efficiently reduced, and the overall extraction time was found to be only 7 min. The variables affecting the method are optimized. Under the optimal experimental conditions (75 μL of 1‐undecanol, a flow rate of 2.0 mL/min, and an ultrasound irradiation of 1 min), the proposed method exhibits good preconcentration factors (52–97), low limits of detection (1.0–5.0 ng/mL), and linearities in the range of 5–1500 ng/mL (r 2 ≥ 0.995). Finally, the method is successfully applied to the analysis of phthalate esters in the drinking and river water samples. To study the probable release of the phthalate esters from a polyethylene container into boiling water, the boiling water exposed to the polyethylene container was analyzed by the proposed method.  相似文献   

18.
《Electrophoresis》2017,38(7):1083-1090
Hippuric acid (HA) and 4‐methylhippuric acid (4‐MHA) are metabolites as well as biological indicators for toluene and xylenes, respectively, and their determination in urine samples is very important, in order to monitor the occupational exposition to these solvents, ensuring a safe working environment. Thus, this paper describes the synthesis and characterization of a probe impregnated with molecularly imprinted polymers (MIPs) for the solid‐phase extraction of HA and 4‐MHA directly from untreated urine samples followed by micellar electrokinetic chromatography (MEKC) analyses. The MIP probe selectivity was compared to the non‐imprinted polymer probe. The MEKC separations were carried out in 50 mmol/L sodium tetraborate pH 10.0/0.5 mmol/L cetyltrimethylammonium bromide aqueous solution, with a constant voltage of –15 kV. The system variables were optimized to provide ideal conditions for the extraction and desorption of the analytes, as well as for the MEKC analyses. The method was linear from 0.5 to 5.0 g/L for both analytes, with correlation coefficients > 0.994. Precisions and accuracies, expressed as relative standard deviation and relative error, were < 20.0 and within –15.4 to 16.6%, respectively, in accordance with the United States Food and Drug Administration recommendation. The MIP probe has proven to be simple, cheap, resistant, and synthetically reproducible, being successfully used to analyze both HA and 4‐MHA from real samples.  相似文献   

19.
Polypyrrole‐magnetite dispersive micro‐solid‐phase extraction method combined with ultraviolet‐visible spectrophotometry was developed for the determination of selected cationic dyes in textile wastewater. Polypyrrole‐magnetite was used as adsorbent due to its thermal stability, magnetic properties, and ability to adsorb Rhodamine 6G and crystal violet. Dispersive micro‐solid‐phase extraction parameters were optimized, including sample pH, adsorbent amount, extraction time, and desorption solvent. The optimum polypyrrole‐magnetite dispersive micro‐solid phase‐extraction conditions were sample pH 8, 60 mg polypyrrole‐magnetite adsorbent, 5 min of extraction time, and acetonitrile as the desorption solvent. Under the optimized conditions, the polypyrrole‐magnetite dispersive micro‐solid‐phase extraction with ultraviolet‐visible method showed good linearity in the range of 0.05–7 mg/L (R 2 > 0.9980). The method also showed a good limit of detection for the dyes (0.05 mg/L) and good analyte recoveries (97.4–111.3%) with relative standard deviations < 10%. The method was successfully applied to the analysis of dyes in textile wastewater samples where the concentration found was 1.03 mg (RSD ±7.9%) and 1.13 mg/L (RSD ± 4.6%) for Rhodamine 6G and crystal violet, respectively. It can be concluded that this method can be adopted for the rapid extraction and determination of dyes at trace concentration levels.  相似文献   

20.
A high‐throughput and environmentally friendly method based on 96‐well plate thin‐film microextraction was established to determine 14 fungicides in grapes and grape juice using liquid chromatography–tandem mass spectrometry. The thin‐film microextraction optimized method consisted of 60 min of extraction at pH 6.0 with the addition of sodium chloride (2–5%). Acetonitrile/water in the ratio of 8:2 was used for desorption analytes for 60 min. Evaluation of different extractive phases showed that polyacrylonitrile–polystyrene–divinylbenzene was the optimum coating. The linearity of the method was good in the range of 0.01–0.5 μg/mL for 14 fungicides with determination coefficients (R2) from 0.990 to 0.999, which indicated good linearity for both the grape juice and grape matrixes. The limit of detection was in the range of 0.002–0.01 μg/mL. The limit of quantitation was in the range of 0.01 mg/kg according to the minimum fortified level. The average absolute recoveries of the 14 fungicides ranged from 75.0 to 118.3%. The intraday relative standard deviation (n = 4) and interday relative standard deviation (n = 4) were 5.6–13.0% and 1.6–6.4%, respectively. This study showed that this method can be used for analyzing 96 samples in parallel, and the sample preparation time was approximately 2.0 min per sample. In addition, this approach offers a green and low‐cost sample pretreatment technique for future analyses.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司    京ICP备09084417号-23

京公网安备 11010802026262号