首页 | 官方网站   微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 62 毫秒
1.
A simple and reliable method has been developed for the determination of uranium(VI). The method is based on the separation and preconcentration of uranium(VI) using a column packed with 8-hydroxyquinoline immobilized on surfactant coated alumina prior to its spectrophotometry determination with Arsenazo III. The effect of pH, sample flow rate and volume, elution conditions, and foreign ions on the sorption of uranium(VI) has been investigated. A preconcentration factor of 200 was achieved by passing 1000 mL of sample through the column. The relative standard deviation for 10 replicate analyses at the 100 ng/mL level of uranium(VI) was 2.1% and the detection limit was 0.12 ng/mL. The method was successfully applied to the determination of uranium in natural water samples. The accuracy was assessed through recovery experiments and the analysis of a certified reference material.  相似文献   

2.
A simple and effective method has been presented for the preconcentration of uranium by solid phase extraction. For this purpose arsenazo(III) supported on naphthalene‐methyltrioctylammonium chloride was used as an adsorbent and uranium solution at pH 3.5 with flow rate of 1 mL·min−1 was passed through the column. Therefore, uranium‐arsenazo(III) complex was formed onto column. Uranium was quantitatively eluted with 5 mL of a 0.1% ammonium tetraphenylborate and determined by spectrophotometric method at 652 nm. Several parameters such as pH, amount of reagents, sample volume, etc. were investigated. The effect of diverse ions on the preconcentration has also been studied and the optimized conditions developed have been utilized for the trace determination of uranium. A preconcentration factor of 100 was achieved. The relative standard deviation (N=8) was 0.5% for 3 ng· mL−1 of uranium. The three sigma detection limit (36) was 0.045 ng·mL−1  相似文献   

3.
A chitosan resin possessing a phenylarsonic acid moiety (phenylarsonic acid type chitosan resin) was developed for the collection and concentration of trace uranium prior to inductively coupled plasma (ICP) atomic emission spectrometry (AES) measurement. The adsorption behavior of 52 elements was systematically examined by packing it in a minicolumn and measuring the elements in the effluent by ICP mass spectrometry. The resin could adsorb several cationic species by a chelating mechanism, and several oxo acids, such as Ti(IV), V(V), Mo(VI), and W(VI), by an anion-exchange mechanism and/or a chelating mechanism. Especially, U(VI) could be adsorbed almost 100% over a wide pH region from pH 4 to 8. Uranium adsorbed was easily eluted with 1 M nitric acid (10 mL), and the 25-fold preconcentration of uranium was achieved by using a proposed column procedure, which could be applied to the determination of trace uranium in seawater by ICP-AES. The limit of detection was 0.1 ng mL−1 for measurement by ICP-AES coupled with 25-fold column preconcentration.  相似文献   

4.
A novel flow injection method has been developed for the indirect determination of uranium by the on-line reduction and subsequent fluorimetric detection of cerium(III). A sample solution containing uranium(VI), prepared as a sulfuric acid solution, was injected into a sulfuric acid carrier solution and passed through a column packed with metal bismuth to reduce uranium(VI) to uranium(IV). The sample solution was merged with a cerium(IV) solution to oxidize uranium(IV) to uranium(VI) and the cerium(III) generated was then monitored fluorimetricaly. The present method is free from interference from zirconium, lanthanides, and thorium, and has been successfully applied to the determination of uranium in monazite coupled with an anion-exchange separation in a sulfuric acid medium to eliminate iron(III). The sample throughput was 25 per hour and the lowest detectable concentration was 0.0042 mg l(-1).  相似文献   

5.
A novel method using a micro-column packed with active alumina as solid phase was proposed for separation of trace lithium from uranium compounds prior to determination. The method is based on a preliminary chromatographic separation of the total amount of uranium. This separation involves passing the solution containing sodium carbonate through active alumina and then eluting the trace lithium retained by the solid phase with a solution of sulfuric acid. Two modes, off-line and on-line micro-column preconcentration, were performed. In conjunction with atomic absorption spectrometry, this on-line preconcentration technique allows a determination of lithium at 10(-9) level. Both off-line and on-line mode operation conditions were investigated in separation and determination of trace lithium by micro-column method (length of column bed, flow rate, etc.). The adsorption capacity of activated alumina was found to be 343 microg g(-1) for lithium. Under the optimal operation condition, the detection limit (DL) of on-line preconcentration corresponding to three times the standard deviation of the blank (S/N = 3) was found to be 1.3 ng mL(-1) and the RSD of this method is 3.32% (n = 5). The on-line calibration graph was linear over the range 20 - 200 ng mL(-1). A good preconcentration factor 820 was achieved by experiment under the on-line mode. The developed method was applied to the analysis of trace lithium in nuclear grade uranium compounds.  相似文献   

6.
An automated method is developed for the spectrophotometric determination of nanoamounts of uranium(VI) with Arsenazo III using online preconcentration by the coprecipitation of the uranium complex of the reagent with organic coprecipitants. The collector was an Arsenazo III ion pair with organic cations poorly soluble in water. The concentrate was separated by filtration through a cellulose fiber membrane and dissolved in a flow of an organic solvent; the analytical signal was recorded as the output peak. The developed method is characterized by simplicity, sufficiently high sensitivity, high throughput and rapidity, and can be used for the selective determination of uranium(VI) in complex liquid matrices. The detection limit is ~0.01 ng/mL (3s, n = 5, P = 0.95). The throughput of the method is 150 samples per hour.  相似文献   

7.
Oguma K  Suzuki T  Saito K 《Talanta》2011,84(5):1209-1214
A flow injection method has been developed for the determination of uranium in seawater combining the on-line preconcentration with spectrophotometric detection. An aliquot (10 mL) of the seawater sample adjusted to pH 5.5 was injected into the analytical system and uranium was adsorbed on the column packed with styrene-divinylbenzene copolymer resin (Bio-Beads SM-2) modified with dodecylamidoxime which showed high selectivity to uranium. Uranium was then eluted with 0.01 M hydrochloric acid and detected spectrophotometrically after the reaction with Chlorophosphonazo III. Interference from calcium and strontium was masked with cyclohexanediaminetetraacetic acid added to the chromogenic reagent solution. The sample throughput, the detection limit (3σ), and the preconcentration factor were 23 per hour, 0.13 μg/L, and 20, respectively, when the sample injection volume was kept at 10 mL. The precision at the 2 μg/L level was less than 4% (RSD). The proposed method was applied to the determination of uranium in the seawater samples collected off the Boso peninsula, Japan and the uranium concentration was found to be ca. 3 μg/L, which is close to the literature data. The yield of the recovery test ranged from 95% to 99%.  相似文献   

8.
A sensitive and simple method for determination of chromium species after separation and preconcentration by solid phase extraction (SPE) has been developed. For the determination of the total concentration of chromium in solution, Cr(VI) was efficiently reduced to Cr(III) by addition of hydroxylamine and Cr(III) was preconcentrated on a column of immobilised ferron on alumina. The adsorbed analyte was then eluted with 5?mL of hydrochloric acid and was determined by flame atomic absorption spectrometery. The speciation of chromium was affected by first passing the solution through an acidic alumina column which retained Cr(VI) and then Cr(III) was preconcentrated by immobilised ferron column and determined by FAAS. The concentration of Cr(VI) was determined from the difference of concentration of total chromium and Cr(III). The effect of pH, concentration of eluent, flow rate of sample and eluent solution, and foreign ions on the sorption of chromium (III) by immobilised ferron column was investigated. Under the optimised conditions the calibration curve was linear over the range of 2–400?µg?L?1 for 1000?mL preconcentration volume. The detection limit was 0.32?µg?L?1, the preconcentration factor was 400, and the relative standard deviation (%RSD) was 1.9% (at 10?µg?L?1; n?=?7). The method was successfully applied to the determination of chromium species in water samples and total chromium in standard alloys.  相似文献   

9.
A simple and sensitive method for the selective determination of Se(IV) and Se(VI) in natural water and sludge samples through an adsorptive process on a nanometer-sized TiO(2) (anatase) was developed. The conditions for quantitative and reproducible preconcentration, elution, and subsequent GFAAS determination were established. The proposed method gave a concentration factor of 50 for a 100 mL sample volume, characterized by high precision, high reproducibility, and direct determination of Se(IV)/Se(VI). The detection limits (3 sigma, n=11) were 4.7ng L(-1) for Se(IV) and 6.3ng L(-1) for Se(VI); the precision (relative standard deviation) was 0.7% for Se(IV) and 0.9% for Se(VI) at the 0.5microg L(-1) level.  相似文献   

10.
A simple and sensitive method has been developed for the trace determination of bismuth in aqueous samples by a combination of solid‐phase extraction and hydride generation atomic absorption spectrometry. The method is based on the use of a column packed with 2‐mercaptobenzothiazole immobilized on sodium dodecyl sulfate coated alumina. Different parameters influencing the separation and preconcentration of bismuth such as pH, sample volume, type, and concentration of eluent, and the flow rate of sample and eluent were studied. A sample volume of 500.0 mL resulted in a preconcentration factor of 100. The precision (relative standard deviation, N = 10) at the 300 ng/L level and the limit of detection (3s) were found to be 2.3% and 12 ng/L, respectively. The developed method was successfully applied to the determination of bismuth in natural water samples and two certified reference materials.  相似文献   

11.
A new solid phase extraction (SPE) method has been developed for the speciation of Cr(III) and Cr(VI). This method is based on the adsorption of Cr(VI) on modified alumina‐coated magnetite nanoparticles (ACMNPs). Total chromium in different samples was determined as Cr(VI) after oxidation of Cr(III) to Cr(VI) using H2O2. The chromium concentration has been determined by flame atomic absorption spectrometric (FAAS) technique and amount of Cr(III) was calculated by substracting the concentration of Cr(VI) from total chromium concentration. The effect of parameters such as pH, amount of adsorbent, contact time, sample volume, eluent type, H2O2 concentration and cetyltrimethylammonium bromide (CTAB) concentration as modifier on the quantitative recovery of Cr(VI) were investigated. Under the optimal experimental conditions, the preconcentration factor, detection limit, linear range and relative standard deviation (RSD) of Cr(VI) were 140 (for 350 mL of sample solution), 0.083 ng mL?1, 0.1‐10.0 ng mL?1 and 4.6% (for 5.0 ng mL?1, n = 7), respectively. This method avoided the time‐consuming column‐passing process of loading large volume samples in traditional SPE through the rapid isolation of CTAB@ACMNPs with an adscititious magnet. The proposed method was successfully applied to the determination and speciation of chromium in different water and wastewater samples and suitable recoveries were obtained.  相似文献   

12.
A new functionalized mesoporous silica (MCM-41) using salicylaldehyde was utilized for the separation, preconcentration and determination of uranium in natural water by inductively coupled plasma atomic emission spectrometry (ICP-AES).Experimental conditions for effective adsorption of trace levels of U(VI) were optimized. The preconcentration factor was 100 (1.0 mL of elution for a 100 mL sample volume). The analytical curve was linear in the range 2-1000 μg L−1 and the detection limit was 0.5 ng mL−1. The relative standard deviation (R.S.D.) under optimum conditions was 2.5% (n = 10). Common coexisting ions did not interfere with the separation and determination of uranium at pH 5. The sorbent exhibited excellent stability and its sorption capacity under optimum conditions has been found to be 10 mg of uranium per gram of sorbent. The method was applied for the recovery and determination of uranium in different water samples.  相似文献   

13.
A resonance light scattering (RLS) method for the direct detection of uranium (VI) or uranyl in aqueous solution without separation procedure has been reported in this paper. Sulfo-salophen, a water-soluble tetradentate Schiff base ligand of uranyl, reacted with uranyl to form a complex. The complex reacted further with oxalate to form supramolecular dimer with large molecular volume, resulting in a production of strong RLS signal. The amount of uranium (VI) was detected through measuring the RLS intensity. A linear range was found to be 0.2–30.0 ng/mL under optimal conditions with a detection limit of 0.15 ng/mL. The method has been applied to determine uranium (VI) in environmental water samples with the relative standard deviations of less than 5 % and the recoveries of 98.8–105.8 %. The present technique is suitable for the assay of uranium (VI) in environmental water samples collected from different sources.  相似文献   

14.
Uranium(VI) is adsorbed as a uranium trifluoroethylxanthate (TFEX)-cetyltrimethylammonium (CTMA) ion-pair complex on microcrystalline naphthalene quantitatively in the pH range 4.2 - 7.0. Without cetyltrimethylammonium as the counter ion, the adsorption is hardly 70%. The metal has been desorbed with HCI and determined with a differential pulse polarograph. Uranium can alternatively be quantitatively adsorbed on TFEX-CTMA-naphthalene adsorbent packed in a column at a flow rate of 1 - 5 ml/min and determined similarly. A well-defined peak has been obtained in this medium at -0.20 V versus a saturated calomel electrode. Cyclic voltammetry, differential pulse polarography and D.C. polarography studies indicate that uranium has been reduced irreversibly under these conditions. The detection limit is 0.30 microg/ml at the minimum instrumental settings (signal-to-noise ratio of 2) (with a preconcentration factor of 10, the detection limit would be 30 ng/ml for uranium when the volume in the cell is 15 ml). However if the volume in the cell is 5 ml, it would have been 10 ng/ml with a preconcentration factor of 30. Linearity is maintained in a concentration range of 0.5 - 19.0 microg/ml (2.1 - 79.83 x 10(-9) M) with a correlation factor of 0.9994 and a relative standard deviation of +/-1.1% (in this case 7.5 microg may be concentrated from 150 ml of the aqueous sample where its concentration is as low as 50 ng/ml). Various parameters, such as the effect of the pH, volume of the aqueous phase, flow rate and the interference of a large number of metal ions and anions on the determination of uranium, have been studied in detail to optimize the conditions for its trace determination in various complex materials, like alloys, coal fly ash, biological, synthetic, and waste-water samples.  相似文献   

15.
A flow injection system has been developed consisting of on-line preconcentration of selenium species in a microcolumn filled with activated alumina, reduction of Se(VI) to Se(IV) and determination by HG-AAS. When 0.01 mol/L HNO3 is used both as carrier and activation reagent for the alumina microcolumn, up to 150 ng of Se(IV) and Se(VI) can be preconcentrated and quantitatively eluted by 500 L of 2 mol/L NH3. The preconcentration factor is 50 when 25 mL of sample is used. The detection limit is about 6 ng/L, the precision is 5% for low concentrations such as 150 ng/L and 3% at high concentrations such as 120 ng/mL. The proposed method is suitable for natural water samples and inorganic Se speciation can be performed by determining Se(IV) and total selenium [Se(VI) is evaluated from the difference].  相似文献   

16.
A simple and effective method is presented for the separation and preconcentration of thorium(IV) and uranium(VI) by solid phase extraction on Duolite XAD761 adsorption resin. Thorium(IV) and uranium(VI) 9-phenyl-3-fluorone chelates are formed and adsorbed onto the Duolite XAD761. Thorium(IV) and uranium(VI) are quantitatively eluted with 2 mol L−1 HCl and determined by inductively coupled plasma-mass spectrometry (ICP-MS). The influences of analytical parameters including pH, amount of reagents, amount of Duolite XAD761 and sample volume, etc. were investigated on the recovery of analyte ions. The interference of a large number of anions and cations has been studied and the optimized conditions developed have been utilized for the trace determination of uranium and thorium. A preconcentration factor of 30 for uranium and thorium was achieved. The relative standard deviation (N = 10) was 2.3% for uranium and 4.5% for thorium ions for 10 replicate determinations in the solution containing 0.5 μg of uranium and thorium. The three sigma detection limits (N = 15) for thorium(IV) and uranium(VI) ions were found to be 4.5 and 6.3 ng L−1, respectively. The developed solid phase extraction method was successively utilized for the determination of traces thorium(IV) and uranium(VI) in environmental samples by ICP-MS.  相似文献   

17.
A simple and rapid chelating-resin-packed column has been developed for preconcentration of trace indium in biological samples. A large-sized urine sample was pumped through a minicolumn at a flow rate of 1.0 mL/min by using a peristaltic pump, and the eluents were analyzed using graphite furnace atomic absorption spectrometry (GFAAS). Four commercially available chelating resins including Chelex-100, Amberlite IRC-50, Duolite GT-73, and Celite 545-AW were studied for evaluating the indium sorption performance. Several parameters, such as pH, resin amount, eluent volume, eluent flow rate, and the volume of sample, were investigated and optimized. A 100-200 mL of the sample was loaded into a column containing 1.2 g of wet Chelex-100 and subjected to the ion-exchange procedure. The retained analytes were eluted with 5.0 mL of 0.1 M HNO(3) and quantified by GFAAS. The correlation coefficient in the range 10-250 ng/mL was of 0.9994. The limit of detection of the proposed method was 2.75 ng/mL. The method developed was successfully applied to analysis of spiked urine samples with good recoveries of 93-103% (n = 6) and reproducibility (relative standard deviation < 4.9%). The accuracy of procedure was confirmed by indium determination in spiked certified reference materials.  相似文献   

18.
A flow-injection analysis (FIA) system incorporating a micro-column of ZrO2 has been used for the development of an on-line multi-element method for the simultaneous preconcentration and determination of Al, Bi, Cd, Co, Cr, Cu, Fe, Ga, In, Mn, Mo, Ni, Pb, Tl, V, Sb, Sn, and Zn by inductively coupled plasma atomic emission spectrometry (ICP-AES). The conditions for quantitative and reproducible preconcentration, elution, and subsequent on-line ICP-AES determination were established. A sample (pH 8) is pumped through the column at 3 mL min(-1) and sequentially eluted directly into the ICP-AES with 3 mol L(-1) HNO3. With a sample volume of 100 mL and an elution volume of 1 mL signal enhancement 100 times better than for conventional continuous aspirating systems was obtained for the elements studied. The reproducibility (RSD %) of the method at the 10 ng mL(-1) level in the eluate is acceptable - less than 8% for five replicates. Recoveries between 95.4% and 99.9% were obtained for the elements analysed. ZrO2, with a specific surface area of 57 m2 g(-1) and a capacity of approximately 5 mg g(-1) for the elements studied, was synthesized by hydrolysis of ZrCl4. The preconcentration system was evaluated for several simple synthetic matrices, standard water samples and synthetic seawater. The effect of foreign ions on the efficiency of preconcentration of the elements studied was investigated. The application of a micro-column filled with high-surface-area ZrO2 and flow injection inductively coupled plasma atomic emission spectrometry enables preconcentration and simultaneous determination of 18 elements at low concentrations (ng L(-1)) in different water samples.  相似文献   

19.
Methods for the on-line chromatographic preconcentration of Cr(III) and Cr(VI) have been developed. Cr(VI) has been preconcentrated on an RP C18 silica based column with tetrabutylammonium-bromide (TBABr) as ion-pairing agent. Specially for Cr(III) a new and effective preconcentration technique based on the sorption of Cr(III)-ions in a C18 column in presence of KH-phthalate has been developed. The efficiency of sample introduction into the atomic emission spectrometer could be improved by hydraulic high pressure nebulization. For the detection of chromium the acetylene/N(2)O flame has been used as a powerful emission spectrometric source. Applying these steps the detection limit (3sigma) could be improved to 25 pg/mL for Cr(III) and to 20 pg/mL for Cr(VI). The method has been applied for the chromium speciation in natural water samples.  相似文献   

20.
The adsorption behavior of multiwalled carbon nanotubes (MWNTs) toward copper has been investigated systemically, and a new method has been developed for the determination of trace copper in water samples based on preconcentration with a microcolumn packed with MWNTs prior to its determination by flame atomic absorption spectrometry. The optimum experimental parameters for preconcentration of copper, such as pH of the sample, sample flow rate and volume, elution solution and interfering ions, have been investigated. Copper can be quantitatively retained by MWNTs in the pH range 5-8, and then eluted completely with 0.5 M HNO3. The detection limit of this method for Cu was 0.42 ng/mL, and the RSD was 3.5% at the 10 ng/mL Cu level. The method was validated using a certified reference material, and has been successfully applied for the determination of trace copper in water samples.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司    京ICP备09084417号-23

京公网安备 11010802026262号