 共查询到20条相似文献,搜索用时 531 毫秒
1.
Previous work has described the use of Coriolis mass flow metering for two-phase (gas/liquid) flow. As the Coriolis meter provides both mass flow and density measurements, it is possible to resolve the mass flows of the gas and liquid in a two-phase mixture if their respective densities are known. To apply Coriolis metering to a three-phase (oil/water/gas) mixture, an additional measurement is required. In the work described in this paper, a water cut meter is used to indicate what proportion of the liquid flow is water. This provides sufficient information to calculate the mass flows of the water, oil and gas components. This paper is believed to be the first to detail an implementation of three-phase flow metering using Coriolis technology where phase separation is not applied.Trials have taken place at the UK National Flow Standards Laboratory three-phase facility, on a commercial three-phase meter based on the Coriolis meter/ water cut measurement principle. For the 50 mm metering system, the total liquid flow rate ranged from 2.4 kg/s up to 11 kg/s, the water cut ranged from 0% to 100%, and the gas volume fraction (GVF) from 0 to 50%. In a formally observed trial, 75 test points were taken at a temperature of approximately 40 °C and with a skid inlet pressure of approximately 350 kPa. Over 95% of the test results fell within the desired specification, defined as follows: the total (oil+water) liquid mass flow error should fall within ±2.5%, and the gas mass flow error within ±5.0%. The oil mass flow error limit is ±6.0% for water cuts less than 70%, while for water cuts between 70% and 95% the oil mass flow error limit is ±15.0%.These results demonstrate the potential for using Coriolis mass flow metering combined with water cut metering for three-phase (oil/water/gas) measurement.  相似文献   

2.
Within the framework of a research project regarding investigations on a high-pressure Coriolis mass flow meter (CMF) a portable flow test rig for traceable calibration measurements of the flow rate (mass - and volume flow) in a range of 5 g min−1 to 500 g min−1 and in a pressure range of 0.1 MPa to 85 MPa was developed. The measurement principle of the flow test rig is based on the gravimetrical measuring procedure with flying-start-and-stop operating mode. Particular attention has been paid to the challenges of temperature stability during the measurements since the temperature has a direct influence on the viscosity and flow rate of the test medium. For that reason the pipes on the high-pressure side are double-walled and insulated and the device under test (DUT) has an enclosure with a separate temperature control. From the analysis of the first measurement with tap water at a temperature of 20 °C and a pressure of 82.7 MPa an extensive uncertainty analysis has been carried out. It was found that the diverter (mainly due to its asymmetric behaviour) is the largest influence factor on the total uncertainty budget. After a number of improvements, especially concerning the diverter, the flow test rig has currently an expanded measurement uncertainty of around 1.0% in the lower flow rate range (25 g min−1) and 0.25% in the higher flow rate range (400 g min−1) for the measurement of mass flow. Additional calibration measurements with the new, redesigned flow test rig and highly viscous base oils also indicated a good agreement with the theoretical behaviour of the flow meter according to the manufacturers׳ specifications with water as test medium. Further improvements are envisaged in the future in order to focus also on other areas of interest.  相似文献   

3.
In the last decade significant progress has been achieved in the development of measurement traceability for LNG inline metering technologies such as Coriolis and ultrasonic flow meters. In 2019, the world's first LNG research and calibration facility has been realised thus enabling calibration and performance testing of small and mid-scale LNG flow meters under realistic cryogenic conditions at a maximum flow rate of 200 m3/h and provisional mass flow measurement uncertainty of 0.30% (k = 2) using liquid nitrogen as the calibration fluid. This facility enabled, for the first time, an extensive test programme of LNG flow meters under cryogenic conditions to be carried out to achieve three main objectives; the first is to reduce the onsite flow measurement uncertainty for small and mid-scale LNG applications to meet a target measurement uncertainty of 0.50% (k = 2), the second is to systematically assess the impact of upstream flow disturbances and meter insulation on meter performance and the third is to assess transferability of meter calibrations with water at ambient conditions to cryogenic conditions. SI-traceable flow calibration results from testing six LNG flow meters (four Coriolis and two ultrasonic, see acknowledgment section) with water in a water calibration facility and liquid nitrogen (LIN) in the LNG research and calibration facility under various test conditions are fully described in this paper. Water and LIN calibration data were compared and it was observed that the influence of removing the meter insulation on mass flow rate measurement accuracy can be more significant (meter error > ±0.50%) than the influence of many typical upstream disturbances when the meter is preceded by a straight piping length equal to twenty pipe diameters (20D) with no additional flow conditioning devices, in particular for ultrasonic meters. The results indicate that the correction models used to transfer the water calibration to cryogenic conditions (using LIN) can potentially result in mass flow rate measurement errors below ±0.5%, however, the correction models are specific to the meter type and manufacturer. This work shows that the target measurement uncertainty of 0.50% can be achieved if the expanded standard error of the mean value measured by the meter is smaller than 0.40% (k = 2). It is planned to repeat these tests with LNG in order to compare the results with the LIN tests presented in this paper. This may reveal that testing with an explosion safe and environmentally friendly fluid such as LIN produces representative results for testing LNG flow meters.  相似文献   

4.
We describe a flow standard for gas flows in the range from 0.01 sccm to 100 sccm with a relative standard uncertainty (68% confidence) of 0.03% at 1 sccm (1 sccm≡1 cm3/min of an ideal gas at 101325 Pa and 0 °C ≈ 0.74358 μmol/s). The flow standard calibrates a secondary meter by withdrawing a piston from a cylinder held at constant pressure P while gas flows from the secondary meter into the cylinder. The flow standard can operate anywhere in the range 10 kPa<P<300 kPa, and it can act as a flow source as well as a flow receiver. The flow standard incorporated features that improved its convenience and lowered its cost without sacrificing accuracy, specifically (1) dry sliding seals made with commercially available, easily replaced, o-rings, (2) a compact design based on a commercially available, hollow piston, and (3) a linear encoder with a small Abbe error.  相似文献   

5.
The paper presents the accuracy and precision associated with realization of primary standard of sound using the reciprocity method. An experimental determination of the front cavity volume on Universal Measuring Machine has lead to reaffirmation of measurement uncertainty in pressure sensitivity determination to 0.04–0.15 dB in frequency range 31.5 Hz to 25 kHz. The reduced measurement uncertainty has also been validated from the results of the recent APMP Key comparison and also by comparison to the manufacturer’s value for LS2P microphones. The use of optical method for measuring the front cavity volume has refined the measurement methodology followed with adaptation of a self reliant, traceable and systematic measurement procedure in comparison to the earlier use of nominal values for sensitivity fitting exercise conducted on MP.EXE program. Consequently, the measurement uncertainty associated with the calibration of working standard microphones, multifunction acoustic calibrator and A-weighted sound pressure level measurements is also reduced.  相似文献   

6.
《Measurement》2007,40(7-8):741-745
In this paper, we investigate the characteristics of a piezoresistive AFM cantilever in the range of 0–1.6 μN by using nano force calibrator (NFC), which consists of a high precision balance with resolution of 1 nN and 1-D fine positioning stage. Brief modeling of the cantilever is presented and then, the calibration results are shown. Tests revealed a linear relationship between the probing force and sensor output (resistance change), but the force vs. deflection is not as linear as the force vs. sensor output curve. The force constant of the cantilever was measured to 0.26 N/m with a standard deviation of 0.01 N/m. It shows that there is big difference between measured and nominal spring constant of 1 N/m provided by the manufacturer’s specifications.  相似文献   

7.
In the framework of the ongoing EMPIR JRP 16ENG01 “Metrology for Hydrogen Vehicles” a main task is to investigate the influence of pressure on the measurement accuracy of Coriolis Mass Flow Meters (CFM) used at Hydrogen Refueling Stations (HRS). At a HRS hydrogen is transferred at very high and changing pressures with simultaneously varying flow rates and temperatures. It is clearly very difficult for CFMs to achieve the current legal requirements with respect to mass flow measurement accuracy at these measurement conditions. As a result of the very dynamic filling process it was observed that the accuracy of mass flow measurement at different pressure ranges is not sufficient. At higher pressures it was found that particularly short refueling times cause significant measurement deviations. On this background it may be concluded that pressure has a great impact on the accuracy of mass flow measurement. To gain a deeper understanding of this matter RISE has built a unique high-pressure test facility. With the aid of this newly developed test rig it is possible to calibrate CFMs over a wide pressure and flow range with water or base oils as test medium. The test rig allows calibration measurements under the conditions prevailing at a 70 MPa HRS regarding mass flows (up to 3.6 kg min−1) and pressures (up to 87.5 MPa).  相似文献   

8.
A completely newly designed multi-functional facility for the primary calibration of reference solar cells and the spectral characterization of all solar cell types has been developed and built at PTB. The new facility is based on the successfully applied Differential Spectral Responsivity (DSR) method that allows the determination of the absolute spectral responsivity and nonlinearity of solar cells with the lowest uncertainties. By using a tunable laser system, the new setup avoids the main problem of monochromator-based systems: the low optical power level of the monochromatic beam. Thus it enables a significant reduction of the uncertainty for the short circuit current under standard test conditions ISTC of solar cells. It enables the calibration of World Photovoltaic Scale (WPVS) reference solar cells with an uncertainty of 0.4% (k = 2), the lowest value stated by any WPVS laboratory.  相似文献   

9.
The reported work has been carried out in the direction of establishment of metrological traceability of capacitance up to 200 MHz at CSIR-NPL. In this perspective, the set of seven coaxial reference air-lines (Type 900-LZ series) exhibiting capacitance values varying from 2 pF to 20 pF have been realized as a capacitance standard at high frequency (1 MHz–200 MHz). This is principally achieved with reference to the SI base units of the meter and the second. The standard value of capacitance of each of the reference air-line has been computed up to 1000 MHz by employing transmission line theory. The reference capacitance value of each of these air-lines has also been measured at 1 kHz which thereafter extrapolated up to 1000 MHz using resonance technique. RF impedance analyzer has been calibrated up to 200 MHz for capacitance using computed capacitance of reference air-lines as standard. The reported work will be helpful in establishing the calibration services for low value of capacitance standards in a frequency range from 1 MHz to 200 MHz at CSIR-NPL. The work will also bridge the gap between LF and RF impedance metrology.  相似文献   

10.
A portable device for calibration of trace humidity sensors and an adopted calibration procedure have been developed. The calibration device is based on humidity generation by permeating water through polymeric membrane tubes. Water vapour transmission rates for various polymers were experimentally determined in order to select the most suitable polymeric material. The developed trace humidity generator consists of a gas-flow polymeric hose immersed in a water reservoir thermostated by a sensor-controlled heater. Mole fractions of water vapour between 1 μmol mol−1 and 350 μmol mol−1 (equivalent to frost-point temperatures from −76 °C to −31 °C) were generated by varying either the operating temperature or gas flow. The operating temperature can be varied from 20 °C to 60 °C and kept stable within 0.1 K. Uncertainty analysis indicated that the trace humidity generator produces gas flows of constant humidity amounts with a relative expanded uncertainty less than 3.4% (k = 2) of the generated value.  相似文献   

11.
High pressure air flow standard facilities, including the pVTt facility, sonic nozzle facility and closed loop facility were built in NIM at the end of 2014. The high pressure closed loop gas flow facility was the first closed loop facility in China. The system has 4 sets of 100 mm diameter turbine meters for the reference meters with a flow range of (40–1300) m3/h and a pressure range of (190–2500) kPa. To avoid uncertainties introduced during installation, the reference meters were designed to be calibrated in situ using the sonic nozzle facility. The uncertainty in the pressure measurement was reduced by installing an absolute pressure transducer in the manifold upstream of the reference meters, with differential pressure transducers used to measure the pressure drops across the reference flow meter and the test flow meter. The relative expanded uncertainty for the test meter can reach 0.20% (k = 2) as verified by comparison the sonic nozzle facility and the closed loop facility measurements.  相似文献   

12.
13.
This paper presents the design and calibration of an ISO non-compliant orifice plate flowmeter whose intended use is for respiratory function measurements in the bidirectional air flow range ±9 L/min.The novelty of the proposed sensor consists of a plate beveled in both upstream and downstream sides: a symmetrical geometry is adopted in order to perform bidirectional measurements of flow rate. A mathematical model is introduced to quantify the influence of temperature on the sensor output. Four different positions of the pressure static taps are evaluated in order to maximize bidirectionality. An index is also introduced in order to quantitatively estimate the anti-symmetry of the sensor's response curve.Trials are carried out to evaluate the influence on sensor output of air temperatures (22 °C, 30 °C and 37 °C) at different values of relative humidity (5%, 55% and 85%). Experimental data show a quite good agreement with the theoretical model (R2>0.98 in each condition).The influence of air temperature on the sensor output is minimized by introducing a correction factor based on the theoretical model leading to measurement repeatability better than 2% in overall range of calibration. The mean sensitivity in the calibration range is about 2 kPa L−1·min allowing to obtain a sensor discrimination threshold lower than 0.2 L/min in both directions. The time constant of the whole measurement system, equal to 2.40±0.03 ms, leads to a bandwidth up to 80 Hz making the sensor suitable for respiratory function measurements.  相似文献   

14.
Low pressure drop thermal Mass Flow Controllers are generally thought to fulfill needs concerning the realization of a dynamic reference gas mixture generator for accurate gas analysis. A small air flow rate at low pressure drop must be controlled in a stable and precise way in the generator. True operative pressure drop limits, set point reproducibility, calibration needs and flow rate stability during operations were investigated for a low pressure drop thermal Mass Flow Controller. The flow rate bias due to late calibration and flow rate short-term stability were measured and discussed. The Allan method was used to calculate stability during operation. Calibration uncertainty, bias for late calibration, stability and set point reproducibility were composed to calculate the total uncertainty of the flow rate as a function of the operation time. Results show that it is possible to operate below the target uncertainty stated for a dynamic generator of gas mixtures down to 100 Pa pressure drop. Stability gives the main contribution to total uncertainty at very short operation times, while calibration uncertainty gives the main contribution to total uncertainty at normal operation times. The calibration uncertainty at 0.1% is low enough to assure the target uncertainty for operation times over 10 s. Daily verification of calibration enhances the reliability of the measurement. An accurate voltmeter is necessary for the reproducibility of the set point.  相似文献   

15.
《Ultramicroscopy》2011,111(1):11-19
We present a new method to improve the accuracy of force application and hardness measurements in hard surfaces by using low-force (<50 μN) nanoindentation technique with a cube-corner diamond tip mounted on an atomic force microscopy (AFM) sapphire cantilever. A force calibration procedure based on the force-matching method, which explicitly includes the tip geometry and the tip-substrate deformation during calibration, is proposed. A computer algorithm to automate this calibration procedure is also made available. The proposed methodology is verified experimentally by conducting AFM nanoindentations on fused quartz, Si(1 0 0) and a 100-nm-thick film of gold deposited on Si(1 0 0). Comparison of experimental results with finite element simulations and literature data yields excellent agreement. In particular, hardness measurements using AFM nanoindentation in fused quartz show a systematic error less than 2% when applying the force-matching method, as opposed to 37% with the standard protocol. Furthermore, the residual impressions left in the different substrates are examined in detail using non-contact AFM imaging with the same diamond probe. The uncertainty of method to measure the projected area of contact at maximum force due to elastic recovery effects is also discussed.  相似文献   

16.
This paper describes a primary standard for liquid micro-flow, which covers the flow rate range from 1 ml/min down to 100 nl/min with uncertainties in the range from 0.1% to 0.6% (coverage factor 95%). To realize stable flow rates, METAS applies the principle of generating flow by means of a constant pressure drop over a capillary tube according to the law of Hagen–Poiseuille. The constant pressure drop is mainly possible due to the fact that the relative pressure at the outlet needle remains constant as the outlet needle is positioned just above the beaker collecting the water. The special beaker and the adjustments for the weighing zone to control evaporation will be discussed in the paper as well as measurement results from flow sensors and flow generators, which highlight the repeatability and the reproducibility of the facility.  相似文献   

17.
A motorized 5 m tape comparator was constructed in TUBITAK UME for calibration of tapes and rules up to 5 m length in one set-up and further lengths in multiple set-ups. The system is a practical development and provides a cost effective solution for calibration of tapes in which the highest grade’s accuracy requirement in OIML R35-1 e.g. is 600 μm for 5 m length and 1100 μm for 10 m length. It is mainly composed of 6 m rail system, mechanical parts, optical units and an integrated 6 m incremental linear encoder as a reference measurement axis for traceable measurements. The rails are kinematically located on a heavy marble construction and a motorized carriage, which employs a camera for probing of the scales on the tapes, is moved along the rails during the measurement. The image of the scale taken by the camera is viewed on the monitor screen together with the running software. The operator can perform the probing process by simply moving the carriage over the measured scales (tapes or rules) using a joystick. The carriage movement is measured by the incremental linear encoder previously calibrated by a laser interferometer and the software automatically takes the measurement results from the incremental linear encoder, applies correction values previously defined and determines the length of the tapes and rules as well as deviations from nominal lengths. The estimated expanded uncertainty of the steel tape measurement is U = 54 μm in one set-up (for 5 m length) and U = 77 μm in two set-ups (for 10 m length) at the confidence level of approximately 95%. Uncertainty budget for calibration of the device itself and for calibration of the test tapes are explained in detail. The results of extensive experimental work and analysis are provided by demonstrating application of science and technology of measurement and instrumentation. Investigations for long term stability of the system are given with the reported test results for the years of 2003-2011 and participated intercomparison results to validate the device scientifically are illustrated.  相似文献   

18.
《Measurement》2007,40(7-8):797-802
A deadweight-type torque standard machine of 20 kN m rated capacity (20 kN m-DWTSM) has been designed and developed by the National Metrology Institute of Japan (NMIJ) at the National Institute of Advanced Industrial Science and Technology (AIST). Each uncertainty contribution comes mainly from the performance of each mechanical part of the 20 kN m-DWTSM. Authors evaluated the uncertainty of the mass of the linkage weights, local acceleration of gravity, influence of air buoyancy on deadweight loading, initial moment-arm length (including CMM measurement and temperature compensation), and sensitivity of the fulcrum. This report deals especially with evaluation of the remaining contributions, namely the influence of arm flexure and reference line variation at the end of the moment-arm on best measurement capability (BMC). Estimation of BMC in the 20 kN m-DWTSM gave a relative expanded uncertainty of less than 7.0 · 10−5 (k = 2) for the calibration range from 200 N m to 20 kN m.  相似文献   

19.
With the vigorous development of fuel cell vehicles, the hydrogen consumption in the driving process of fuel cell vehicles has become a major concern of automobile manufacturers and fuel suppliers. However, the measurement accuracy of flow meter in hydrogen medium cannot meet the requirements. In this paper, computational fluid dynamics software is used to simulate the velocity distribution of water and hydrogen in Coriolis flow meter with different mass flow rates without tube vibration. Aiming at the measurement error of Coriolis flow meter, a flow calibration device based on sonic nozzle was designed, and the results of measuring hydrogen mass flow by Coriolis flow meter and thermal flow meter were calibrated. Finally, the accuracy of the calibrated flow meter for measuring hydrogen mass flow under stable and dynamic conditions is tested. The test results show that the accuracy of calibrated Coriolis flow meter for hydrogen mass flow is less than ±1%, which can meet the accuracy requirements of fuel cell vehicle hydrogen consumption measurement. This study provides an important reference for the application of flow meter method in fuel cell vehicle economic evaluation method.  相似文献   

20.
The measurement principle of vortex flowmeter is based on von Karman vortex shedding phenomenon. Frequency of vortices, behind the bluff body, is proportional to the mean flow velocity. There are different ways of detection of vortices, and different sensors are used (presser sensors, capacitive sensors, thermo-resistance sensors, ultrasonic sensors, etc.). Proposed method to vortex identification, presented in this paper is based on simultaneous detection of pair of vortices with opposite circulation, by means of two pairs of ultrasonic transducers. A beam of ultrasound, from ultrasonic transmitter to ultrasonic receiver is transmitted perpendicularly to the vortex street. The received ultrasonic signal is amplitude and phase modulated. Frequency of demodulated signal is equal to the frequency of vortices. This technique allows a number of advantages comparing to conventional solutions: reduction, or elimination of noises caused by installation vibration and disturbances in the flow, higher sensor sensitivity, which as a result leads to a possibility of a reduction of the bluff body size, i.e. reduction of the pressure drop on the flow meter, increase of the measurement range in the low flow region, the possibility of redundant operation of the flow meter, reduced measurement uncertainty, instrument technology improvements, improved reliability of the instrument, assured improved statement of complete uncertainty contributions, improved metrology of the equipment as such and calibration procedures that contribute to measuring capabilities etc. For experimental testing a prototype vortex flowmeter of a nominal inner diameter (ID) 50 mm is developed. A cylindrical bluff body for vortex shedding is used. Ultrasonic transducers based on piezo-crystal PZT-5A, inserted in the wall of the vortex meter casing are utilized. The testing of prototype ultrasonic vortex flowmeter is realized on the calibration station on the water. The results at the testing point to the possibility of measuring flow of liquid fluids at velocities less than 0.5 m/s, with an uncertainty better than ±1%.  相似文献   