首页 | 官方网站   微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 140 毫秒
1.
The chemical compositions (organic and inorganic contents) and mechanical behaviors of the dentin of permanent and deciduous teeth were analyzed and compared using X‐ray fluorescence spectrometry (µ‐EDXRF) Fourier transform Raman spectroscopy (FT‐Raman) and a microhardness test (HD). Healthy fresh human primary and permanent molars (n = 10) were selected, The buccal surfaces facing upwards were stabilized in an acrylic plate, flattened, polished, and submitted to the µ‐EDXRF, FT‐Raman, and HD analysis. The results of the analysis were subjected to ANOVAs and Mann‐Whitney U/Student's t multiple comparisons tests. The data showed similar values for the dentin of the primary and permanent teeth in P content, organic content (amide I peak), inorganic content ( – 430 and 590), and microhardness, Nevertheless, Ca content and Ca/P weight ratio were higher, and the peak was lower in the dentin of the permanent teeth compared to primary teeth. It be concluded that despite permanent teeth showed more Ca element, both substrates showed similar behavior of chemical and physical properties.  相似文献   

2.
The present study aims to evaluate the effect of brushing with fluoride dentifrice on teeth severely affected by erosion due to respiratory medicaments. Enamel (n = 50) and dentin (n = 50) bovine specimens were prepared and treated with artificial saliva (S‐control), acebrofilin hydrochloride (AC), ambroxol hydrochloride (AM), bromhexine hydrochloride (BR), and salbutamol sulfate (SS) and subjected to cycles of demineralization (immersing in 3 mL, 1 min, three times a day at intervals of 1 hr, for 5 days) followed by remineralization (saliva, 37°C, 1 hr). Simulated brushing with fluoridated toothpaste was performed using 810 strokes in a reciprocal‐action brushing simulator. Scanning electron microscopy, micro energy dispersive X‐ray fluorescence (μ‐EDXRF) spectroscopy and attenuated total reflection Fourier transform infrared (ATR FTIR) spectroscopy were then performed. μ‐EDXRF images showed extensive erosion after treatment with all medicaments. SEM images showed enamel erosion in order SS > BR > AC = AM > S after brushing and fluoridation. FTIR results were in agreement. In case of dentin, μ‐EDXRF measurements showed significant difference in mineral content (percent weight of calcium and phosphate) in SS + brushing + fluoridation treated enamel compared to control, while μ‐EDXRF images showed erosive effects in the order SS > AM>BR > AC = S post brushing + fluoridation. SEM images showed erosion in the order SS > AM = BR > AC > S post brushing + fluoridation. Again, FTIR multivariate results were in agreement. Overall, our study shows that proper oral care is critical when taking certain medication. The study also demonstrates the possible use of FTIR for rapid clinical monitoring of tooth erosion in clinics.  相似文献   

3.
This study investigated the effects of fumaric acid on push‐out bond strength when applied to dentin surfaces and fiber posts. The root canals of 60 mandibular premolar teeth were instrumented and obturated. After removing two thirds of filling material, teeth were prepared according to six randomized groups (n = 10/group) defined by two fiber post surface treatments (0.7% fumaric acid or 9% hydrofluoric acid) and three dentin conditioning treatments [control (no conditioning); 17% ethylenediamine tetraacetic acid (EDTA); or 0.7% fumaric acid]. After fiber post‐cementation, three 1‐mm thick discs were obtained from each tooth by transverse sectioning, and each disc underwent push‐out bond strength testing. Data were analyzed with a one‐way analyses of variance (anova ) and t tests; p < .05 was considered statistically significant. Failure modes were determined by stereomicroscopy, and the surface characteristics of dentin and fiber posts were observed by scanning electron microscopy. Push‐out bond strength was greater for the group in which the post surface treated with hydrofluoric acid and the dentin surface treated with fumaric acid than the nontreated dentin and hydrofluoric acid‐treated post group (p < .05). There were no significant differences between other comparison pairs (p > .05). A combination of fumaric acid dentin conditioning and hydrofluoric acid fiber post treatment strengthened the bonding ability of fiber posts.  相似文献   

4.
The aim of this study was to evaluate radiographically and histologically the pulpal and periapical response to self‐adhesive (Rely X? Unicem) and self‐etching and self‐curing (Multilink®) resin‐based luting materials in deep cavities in dogs' teeth. Deep class V cavities (0.5‐mm–thick dentin) were prepared in 60 canine premolars and the following materials were applied on cavity floor: Groups I/V—RelyX? Unicem; Groups II/VI—Multilink®; Groups III/VII—zinc phosphate cement (control) and; Groups IV/VIII—gutta‐percha (control). Cavities were restored with silver amalgam. Animals were euthanized after 10 days (groups I–IV) and 90 days (groups V–VIII). Tooth/bone blocks were radiographed and processed for histopathological evaluation of pulp and periapical tissue response to the materials. All materials presented similar histopathological features and radiographic findings at both periods. The pulp tissue was intact. The apical and periapical regions and periodontal ligament thickness were normal. No inflammatory cells, resorption of mineralized tissue (dentin, cementum, and alveolar bone) or bacteria were observed. The lamina dura was intact and no areas of periapical bone rarefaction or internal/external root resorption were observed radiographically. It can be concluded that Rely X? Unicem and Multilink® caused no adverse tissue reactions and may be indicated for cementation of indirect restorations in deep dentin cavities without pulp exposure. Microsc. Res. Tech. 78:1098–1103, 2015. © 2015 Wiley Periodicals, Inc.  相似文献   

5.
The present study focuses on evaluating the potential of flattened AgClBr fibre‐optic evanescent wave spectroscopy (FTIR‐FEWS) technique for detection and identification of cancer cells in vitro using cell culture as a model system. The FTIR‐FEWS results are compared to those from FTIR‐microspectroscopy (FTIR‐MSP) method extensively used to identify spectral properties of intact cells. Ten different samples of control and malignant cells were measured in parallel by the above two methods. Our results show a significant similarity between the results obtained by the two methodologies. The absorbance level of Amide I/Amide II, phosphates and carbohydrates were significantly altered in malignant compared to the normal cells using both systems. Thus, common biomarkers such as Amide I/Amide II, phosphate and carbohydrate levels can be derived to discern between normal and cancer cells. However, marked differences are also noted between the two methodologies in the protein bands due to CH3 bending vibration (1480–1350 cm−1). The spectral differences may be attributed to the variation in the penetration depth of the two methodologies. The use of flattened fibre rather than the standard cylindrical fibre has several practical advantages and is considered as an important step towards in vivo measurements in real time, such as that of skin nevi and melanoma using special designs of fibre‐optic–based sensors.  相似文献   

6.
OBJECTIVES: To compare microleakage of three self‐etch adhesives and to analyze enamel surface morphology and interfacial morphology of resin–enamel and resin–dentin interface under scanning electron microscope (SEM). EXPERIMENTAL DESIGN: Study was conducted in 65 extracted human premolars. Class V cavities were prepared in 45 teeth and assigned to three groups (n = 15) according to three self‐etch adhesives (OptiBond All‐in‐One, iBond, and Adper Prompt L‐Pop). After restoration, 10 samples from each group were used to assess microleakage at enamel and dentin margin. Five samples from each group were used for analysis of interfacial morphology at resin–enamel and resin–dentin interface under SEM. Remaining 20 teeth were used to prepare flat enamel buccal surfaces to analyze the difference in surface morphology after treatment with three adhesives (n = 5 each) and 36% phosphoric acid treatment (n = 5). PRINCIPAL OBSERVATIONS: At enamel margin, Prompt L‐Pop depicted least leakage of all the three adhesives and also showed best interfacial adaptation under SEM. At dentin margin, OptiBond All‐in‐One showed significant less leakage than iBond and Prompt L‐Pop. On flat enamel surface, phosphoric acid produced the most retentive etching pattern when compared with the three adhesives. CONCLUSION: Prompt L‐Pop showed the best bonding effectiveness in enamel, whereas OptiBond All‐in‐One performed significantly better in dentin. Microsc. Res. Tech. 2012. © 2012 Wiley Periodicals, Inc.  相似文献   

7.
This study focused on adhesive interface morphologic characterization and nanoleakage expression of resin cements bonded to human dentin pretreated with 1% chlorhexidine (CHX). Thirty‐two non‐carious human third molars were ground flat to expose superficial dentin. Resin composite blocks were luted to the exposed dentin using one conventional (RelyX ARC) and one self‐adhesive resin cement (RelyX U100), with/without CHX pretreatment. Four groups (n = 8) were obtained: control groups (ARC and U100); experimental groups (ARC/CHX and U100/CHX) were pretreated with 1% CHX prior to the luting process. After storage in water for 24 h, the bonded teeth were sectioned into 0.9 × 0.9 mm2 sticks producing a minimum of 12 sticks per tooth. Four sticks from each tooth were prepared for hybrid layer evaluation by scanning electron microscope analysis. The remaining sticks were immersed in silver nitrate for 24 h for either nanoleakage evaluation along the bonded interfaces or after rupture. Nanoleakage samples were carbon coated and examined using backscattered electron mode. Well‐established hybrid layers were observed in the groups luted with RelyX ARC. Nanoleakage evaluation revealed increase nanoleakage in groups treated with CHX for both resin cements. Group U100/CHX exhibited the most pronouncing nanoleakage expression along with porous zones adjacent to the CHX pretreated dentin. The results suggest a possible incompatibility between CHX and RelyX U100 that raises the concern that the use of CHX with self‐adhesive cements may adversely affect resin‐dentin bond. Microsc. Res. Tech. 76:788–794, 2013. © 2013 Wiley Periodicals, Inc.  相似文献   

8.
Zheng X  Pan H  Wang Z  Chen H 《Journal of microscopy》2011,241(2):162-170
Objective: This study was carried out to observe the enzymatic degradation of human dentin collagen fibrils exposed to exogenous collagenase in situ using atomic force microscopy, to understand the characteristics of the enzymatic degradation of collagen fibrils on dentin specimens. Methods: Polished dentin specimens from caries‐free third molars were etched with citric acid, and then treated with an aqueous solution of 6.5% NaOCl for 120 s. The specimen was then put into a fluid cell and treated with a mixed solution of collagenase I (MMP‐1) and collagenase II (MMP‐8) for 9 h. AFM with contact mode was performed in situ to monitor the enzymatic degradation process of the dentin collagen fibrils. The distinctly topographic changes of the dentin surface were recorded continuously during different stages of the enzymatic degradation process. Results: The mixed solution of exogenous collagenase I and collagenase II could degrade dentin organic matrix (mainly collagen) efficiently, and the structures of dentin substrate were clearly exposed. Conclusion: It is possible to carry out real‐time observations on the enzymatic biodegradation process of human dentin collagen fibrils on dentin specimens with atomic force microscopy in situ. By this means, the fine structures of the etched dentin substrate were clearly revealed, possibly contributing to the related study of human dentin in vitro.  相似文献   

9.
The objective of this study was to analyze the dentin‐resin cements interfacial ultramorphologies using two different methods: scanning (SEM) and transmission electron microscopy (TEM). Four commercial products were evaluated: two conventional cementing system (RelyX ARC/Adper? Scotchbond? Multi‐Purpose Plus, 3M ESPE and Clearfil Esthetic Cement/DC Bond, Kuraray) and two self‐adhesive resin cements (RelyX Unicem, 3M ESPE and Clearfil SA Cement, Kuraray). Prepolymerized resin disks (Sinfony, 3M ESPE) were cemented on oclusal dentin surfaces of 24 third human molars, simulating the indirect restorations. After 24 h, teeth were sectioned into 0.9‐mm thick slabs and processed for microscopy analyses (SEM or TEM/ n = 3). Qualitative characterization of dentin‐resin cement interface was performed. Hybrid layer formation with long and dense resin tags was observed only for RelyX ARC cementing system. Clearfil Esthetic Cement/DC Bond system revealed few and short resin tags formation, whereas no hybridization and resin tags were detected for self‐adhesive resin cements. Some interfacial regions exhibited that the self‐adhesive resin cements were not bonded to dentin, presenting bubbles or voids at the interfaces. In conclusion, TEM and SEM bonding interface analyses showed ultramorphological variations among resin cements, which are directly related to dental bonding strategies used for each resin cement tested. Microsc. Res. Tech. 76:1234–1239, 2013. © 2013 Wiley Periodicals, Inc.  相似文献   

10.
This study evaluated the effects of chemical agents on the physical properties and structure of primary pulp chamber dentin using surface roughness, microhardness tests, and scanning electron microscopy (SEM). Twenty‐five primary teeth were sectioned exposing the pulp chamber and were divided into five groups (n = 5): NT, no treatment; SH1, 1% sodium hypochlorite (NaOCl); SH1U, 1% NaOCl + Endo‐PTC®; SH1E, 1% NaOCl + 17% EDTA; and E, 17% EDTA. After dentin treatment, the specimens were submitted to roughness, microhardness testing, and SEM analysis. Roughness and microhardness data were submitted to one‐way ANOVA and Tukey's test (P < 0.05). The SH1E group showed the highest roughness, followed by the E group (P < 0.05) when compared with the NT, SH1, and SH1U groups. Microhardness values of SH1 and SH1U showed no significant difference as compared to the NT (control) group (P > 0.05). Microhardness values could not be obtained in the EDTA groups (SH1E and E). The presence of intertubular dentin with opened dentin tubules was observed in the NT, SH1, and SH1U groups. SH1E showed eroded and disorganized dentin with few opened tubules and the intertubular/peritubular dentin was partially removed. Considering the physical and structural approaches and the chemical agents studied, it can be concluded that NaOCl and NaOCl associated with Endo‐PTC® were the agents that promoted the smallest changes in surface roughness, microhardness, and structure of the pulp chamber dentin of primary teeth. Microsc. Res. Tech. 77:52–56, 2014. © 2013 Wiley Periodicals, Inc.  相似文献   

11.
This study evaluated dentin bond strength (BS) and nanoleakage of non‐ and pre‐etched dentin immediately (T0,), 7 days (T7), and 14 days (T14) after bleaching. Bovine incisors (150) were selected and half of them submitted to intrapulpal dentin etching (e). Non‐ and pre‐etched dentin were subjected to the following (n = 15): no bleaching/control (C); 35% carbamide peroxide (CP); 35% hydrogen peroxide (35% HP); 25% hydrogen peroxide (25% HP); and sodium perborate (SP). Bleaching agents were applied to the pulp chamber four times within a 72‐h interval. Afterwards, pulp chamber dentin was prepared for the BS test at different evaluation times (n = 5): T0, T7, and T14. Composite blocks were built on pulp chamber and sectioned in slices. Slices were reduced to an hour‐glass shape with a cross‐sectional area of 0.8 mm2 and submitted to microtensile BS test. Two additional specimens for each group were prepared for nanoleakage evaluation by transmission electron microscopy (TEM). Results were analyzed by ANOVA (two‐way) and Dunnett's test (p < .05). BS decreased immediately after intracoronal bleaching for both sound and pre‐etched dentin (p < .05). At T14, the BS of non‐etched bleached dentin increased for all groups, whereas the pre‐etched SPe group presented BS similar to the Ce. Nanoleakage within the hybrid layer was perceptible immediately after bleaching, although a decrease in nanoleakage was observed for all groups at T14. Adhesive restorations should be performed 7–14 days after bleaching, according to the bleaching agent used. Intracoronal bleaching should be performed preferably with sodium perborate if previous dentin etching is applied.  相似文献   

12.
The purpose of this study was to evaluate mineral content of root canal dentin after treatment with different antibiotic pastes including the mixture of metronidazole, ciprofloxacin, doxycycline, cefaclor, amoxicillin, or minocycline. Fifty extracted maxillary canine teeth were randomly divided into five groups (n = 10 teeth for each group). Root canals were prepared Reciproc rotary files. Canals were irrigated using 5 ml 5% NaOCl and 1 ml 15% EDTA. Each tooth in all groups were longitudinally splitted into two pieces as a control and experimental samples. Each experimental group received following antibiotic paste; double antibiotic paste (DAP) and triple antibiotic paste with doxycycline (TAPd), TAP with cefaclor (TAPc), TAP with amoxicillin (TAPa), and TAP with minocycline (TAPm) for 21 days. The Ca, P, Mg, Ca, and K levels, and the Ca/P ratio was analyzed by a scanning electron microscope (SEM) equipped using a Bruker energy‐dispersive X‐Ray (EDX) detector. Data were analyzed with independent samples t‐test, one‐way anova, and Duncan tests. Ca and Ca/P ratio showed a statistically significant increase TAP with amoxicillin and cefaclor (p < .05). DAP, TAPd, and TAPm did not change the mineral levels (p > .05). TAPa and TAPc with increased the Ca level and Ca/P ratio of the root canal dentin which consequently positively influences the revascularization process.  相似文献   

13.
Papain‐gel has been utilized as a chemo‐mechanical material for caries removal due to its ability to preserve underlying sound dentin. However, little is known about the effect of the papain enzyme on intact type I collagen fibrils that compose the dentin matrix. Here we sought to define structural changes that occur in intact type I collagen fibrils after an enzymatic treatment with a papain‐gel. Intact and nonmineralized type I collagen fibrils from rat tail were obtained and treated with a papain‐gel (Papacarie) for 30 s, rinsed with water and imaged using an atomic force microscope (AFM). Additionally, polished healthy dentin specimens were also treated using the same protocol described above and had their elastic modulus (E) and hardness (H) measured by means of AFM‐based nanoindentation. AFM images showed that the papain‐gel induced partial degradation of the fibrils surface, yet no rupture of fibrils was noticed. The distinction between gap and overlap zones of fibrils vanished in most regions after treatment, and overlap zones appeared to be generally more affected. Mechanical data suggested a gradual decrease in E and H after treatments. A significant two‐fold drop from the values of normal dentin (E=20±1.9, H=0.8±0.08 GPa) was found after four applications (E=9.7±3.2, H=0.24±0.1 GPa) (P<0.001), which may be attributed to the degradation of proteoglycans of the matrix. In summary, this study provided novel evidence that intact nonmineralized type I collagen fibrils are partially degraded by a papain‐gel. SCANNING 31: 253–258, 2009. © 2010 Wiley Periodicals, Inc.  相似文献   

14.
This study evaluates the bond strength of four self‐etching adhesive systems with different acidity levels in normal and artificially hypermineralized dentin substrate. Healthy human molars were divided into groups: normal dentin—N (n = 36) and artificially hypermineralized dentin—H (n = 36). Self‐etching adhesive systems Clearfil S3 Bond (n = 9), Optibond All in One (n = 9), Clearfil SE Bond (n = 9), and Adhese (n = 9) were used for both the N and H groups. Transparent cylindrical matrices were positioned on the treated dentin surfaces, filled with composite resin, and light‐cured for 40 s. After the transparent cylindrical matrices were removed, the specimens were stored for 24 hr in a humid environment at 37°C and were subjected to a micro‐shear bond strength test. For each group, a specimen was prepared and evaluated in scanning electron microscope for adhesive interface observation. Normality was confirmed and the two‐way analysis of variance and Games–Howell post‐tests were conducted (α = .05). The data demonstrated an interaction between the adhesive system and type of dentin substrate (p < .01). For normal dentin, all adhesive systems assessed were adequate; however, in the hypermineralized dentin, the Clearfil SE Bond two‐step self‐etching adhesive system with mild pH presented the highest immediate bond strength. There was a predominance of adhesive failures for all adhesive systems in the different dentin substrates evaluated. It was concluded that the self‐etching adhesive systems evaluated were efficient for both substrates, and for the hypermineralized dentin, the Clearfil SE Bond presented a higher bond strength value.  相似文献   

15.
This study evaluated the shear bond strength (SBS) and internal marginal adaptation of pulp‐capping materials to dentin. Flat occlusal deep dentin surfaces were produced and randomly assigned to two groups (sound or artificial caries‐affected dentin). The specimens in each group were assigned to one of seven subgroups according to the materials used: Biodentine, Theracal LC, Ultra‐Blend plus, Calcimol LC, ApaCal ART, EQUIA Forte, and Ionoseal. Buildups (3‐mm inner diameter and 2‐mm deep) were made over the dentin surfaces. The bonded specimens were tested under shear forces at a crosshead speed of 0.8 mm/min and fracture modes were determined using a stereomicroscope at 25× magnification. The materials were applied to the pulp floor of prepared Class I cavities and then the cavities were restored with composite resin. Restored molar teeth were subjected to 5,000 thermocycles and sectioned in a bucco–lingual direction. Resin replicas were made to determine the adaptation at the pulp floor with scanning electron microscopy. Significant differences were determined among both bond strengths and gap formations of the materials. EQUIA Forte applied to both dentin substrates had a significantly higher SBS than the other materials. The bond strength of each material was not influenced by the dentin condition. Biodentine (3.03%), EQUIA Forte (7.83%), and Theracal LC (13.37%) had lower gap formations compared to other materials but were not significantly different from each other.  相似文献   

16.
Previous studies have shown the effects of Er,Cr:YSGG laser irradiation on the dentin bond strength; but there are few reports that show the significance of the irradiation with different laser parameters on dentin bond strength and interface morphology. This in‐vitro study attempted to evaluate the microtensile bond strength (μTBS) and interface morphology of resin‐dentin interfaces, either followed by treatment with Er,Cr:YSGG laser irradiation with different parameters or not. The flattened dentin samples of 35 bovine teeth were embedded into acrylic blocks and randomly divided into seven groups according to surface treatments using Er,Cr:YSGG lasers with different parameters: 3 W/20 Hz, 3 W/35 Hz, 3 W/50 Hz, 1.5 W/20 Hz, 1.5 W/35 Hz, 1.5 W/50 Hz, or no laser treatment (n = 5). Composite buildups were done over bonded surfaces and stored in water (24 hours at 37°C). Specimens were sectioned into sticks that were subjected to μTBS testing and observed under FE‐SEM. Control groups (27.70 ± 7.0) showed statistically higher values than laser‐irradiated groups. There were no significant differences among laser groups. Despite that, increasing the pulse frequency yielded slightly higher bond strength. Depending on laser settings, Er,Cr:YSGG laser irradiation caused interfacial gaps and resin tags with wings morphology. With the parameters used in this study, Er,Cr:YSGG laser irradiation promoted morphological changes within resin‐dentin interfaces and negatively influenced the bond strength of adhesive systems. Microsc. Res. Tech. 78:1104–1111, 2015. © 2015 Wiley Periodicals, Inc.  相似文献   

17.
This study evaluated the effect of Er,Cr:YSGG laser on the root canal dentin after luting a fiber post. Twenty‐four bovine teeth roots were prepared using NiTi instruments and filled with Sealer 26 and gutta‐percha. Post spaces were prepared and roots were distributed according to dentin treatment (n = 8): 2.5%NaOCl (group control), Er,Cr:YSGG laser (1.5 W, 20 Hz, 20 s) (group test 1) or 2.5%NaOCl + Er,Cr:YSGG laser (group test 2). Fiber posts were luted using adhesive cement (Rely X U200, 3M) and roots were prepared to confocal laser scanning microscopy (CLSM) and scanning electron microscope (SEM). The morphology of interface, thickness of cement, and the gaps and tags were analyzed. Non‐parametrical data for thickness of cement were submitted to Friedman and Kruskall–Wallis tests (α = 0.05) and parametrical data for gaps to ANOVA (α = 0.05). CLSM of the cement thickness and gaps revealed no significant difference in surface treatment (NaOCl, Er,Cr:YSGG laser and NaOCl + Er,Cr:YSGG laser) (p > .05) and canal thirds (cervical, middle, and apical) (p > 0.05). SEM showed tags and a residual layer of cement adhered to dentin, mainly in laser‐irradiated specimens. The pretreatment of root canal with Er,Cr:YSGG laser previously to luting the fiber post with a self‐adhesive cement did not influence the cement thickness and gaps but affected the dentin interaction.  相似文献   

18.
This paper explores the applicability of micro‐FTIR mapping to study heterogeneity of organic matter‐lean siltstones. Closely spaced samples of Late Devonian dolomitic siltstones of the Middle Bakken Member were analysed with micro‐FTIR, powder X‐ray diffraction, and scanning electron microscopy (SEM) to explore the distribution and chemical properties of organic matter (OM), muscovite/feldspar/clay group, carbonates, and quartz, and their influence on porosity and permeability of these rocks. Our results show that quartz is the dominant component of the samples, and the main mineralogical differences between the samples are reflected in the abundance of carbonate minerals. Organic matter content is usually far below 1 wt. % and dominantly represented by terrestrially derived vitrinite and inertinite. Micro‐FTIR mapping demonstrates that the more spatially connected quartz and muscovite/feldspar/clays become, the larger permeability in the rock develops, and these correlations are especially strong for planes parallel to bedding. In contrast, carbonate connectivity shows a strong negative correlation with permeability. No correlations between connectivity of components and porosity have been detected. These observations suggest that micro‐FTIR not only can document compositional heterogeneity of siltstones, but also has potential to help understanding their permeability systems.  相似文献   

19.
This study evaluated the effect of 10% sodium hypochlorite (NaOCl) as deproteinizing agent and storage media on bond strength (BS) of two etch‐and‐rinse adhesive systems to dentin. Twenty‐eight sound extracted human third molars were divided in four groups (n = 7), according to dentin treatment (conventional etching or etching followed by 10% NaOCl application) and adhesive systems (GB—Gluma 2Bond and OS—One‐Step). After dentin treatments and adhesive application, a composite block was built‐up on dentin surface and teeth were serially sectioned to obtain bonded sticks specimens. The sticks were submitted to three aging conditions: (24H) 24 hr in water (immediate), (SH) 3 hr of NaOCl accelerated‐aging or (1Y) 1 year of water storage. Afterward, submitted to microtensile bond strength test (μTBS), failure modes and adhesive interfaces analyzes. Data were analyzed by two‐way analysis of variance (ANOVA) and Tukey's test (α = .05). Dentin deproteinization before bonding significantly reduced μTBS for GB‐treated group (p < .05), regardless the aging conditions. Water storage for 1 year (1Y) and NaOCl accelerated‐aging (SH) decreased μTBS for both adhesives. Yet, the groups stored in NaOCl (SH) exhibited the lowest BS results (p < .05). Bond strength of deproteinized dentin was dependent on the adhesive system composition and NaOCl accelerated‐aging promoted decreased bond strength and further degradation than water storage for 1 year.  相似文献   

20.
The objective of this study is to investigate effects of etchant on dentin surface as a function of etching time by atomic force microscopy (AFM). Twenty intact, freshly extracted noncarious human teeth were used to make 40 dentin discs and the discs were randomly divided into 4 groups. A commercial etchant was applied on these dentin discs. The main component of the etchant is 32% phosphoric acid and the etching time for the four dentin disc groups was 0, 20, 40, and 60 s. The AFM results show progressive changes of the surface morphology as the etching time increases. Significant difference of average roughness (Ra) exists in the dentin surface among all four groups (p<0.05). The statistic difference of diameters of dentinal tubule orifice (Dt) exists between the control group and all other groups (p<0.05), whereas the Dts for the 40‐s group and 60‐s group are not statistically different (p>0.05). Our results showed that acid treatment has a significant influence on dentin demineralization and the effective etching time of the dentin surface appears to be 60 s. We provide a new nanoscale insight into the dentin surface treatment and this can help us to select the optimal etching time in clinic. SCANNING 31: 28–34, 2009. © 2009 Wiley Periodicals, Inc.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司    京ICP备09084417号-23

京公网安备 11010802026262号