首页 | 官方网站   微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Ultrasonic temperature measurement has the potential to improve measurement accuracy by increasing the length of a received signal due to its excellent performance with noise resistance. However, when the distance between the transmitter and receiver is limited, the received signal can be polluted by strong multiple echoes, which can significantly degrade temperature accuracy. This paper proposes a method for high-resolution ultrasonic temperature measurement. With the use of a maximum length sequence (MLS)-modulated continuous wave, the obstructive effect of echoes is effectively suppressed. A hybrid method is employed for accurate time-of-flight (TOF) estimation by incorporating both cross-correlation and phase shift (PS), which is the basis of highly accurate temperature measurement. The experimental results in distilled water show that the proposed method estimates TOF with a standard deviation of less than 0.3 ns, and temperature errors consistently remain within ±0.04 °C.  相似文献   

2.
To evaluate the straightness of large objects, the use of an inclinometer is advantageous because it requires neither straight shape references nor transferring mechanisms. Herein, we consider adopting it for precise (with greater accuracy than 1 mm) evaluation of the straightness of linear particle accelerators (linacs) that are several hundred meters long or longer. In this study, the straightness evaluation of a 206-m-long part of the KEK injector linac was demonstrated using inclinometers with a pair of cantilevers called offset bars. The offset bars were adopted to extend the evaluation length by avoiding obstacles that block the evaluation path. Errors caused by the offset bars can be eliminated by reversal measurement considering the slope angles of the offset bars. The derived straightness corresponded with those derived by an alignment telescope and a laser-based alignment system within several millimeters and partly within several hundred micrometers. The reproducibility of slope angles for an arbitrary measurement point was 15 μrad at standard deviation. This corresponds to a standard deviation of 0.47 mm for straightness, with a total evaluation length of 500 m and measurement intervals of 2 m. The results indicate that our newly devised method is applicable for evaluating the straightness.  相似文献   

3.
Machine tool calibration is becoming recognised as an important part of the manufacturing process. The current international standards for machine tool linear axes calibration support the use of quasi-static calibration techniques. These techniques can be time consuming but more importantly a compromise in quality due to the practical restriction on the spatial resolution of target positions on the axis under test. Continuous motion calibration techniques have the potential to dramatically increase calibration quality. Through taking several measurement values per second while the axis under test is in motion, it is possible to measure in far greater detail. Furthermore, since machine tools normally operate in dynamic mode, the calibration data can be more representative if it is captured while the machine is in motion. The drawback to measuring the axis while in motion is the potential increase in measurement uncertainty. In the following paper, different methods of continuous motion calibration are discussed. A time-based continuous motion solution is proposed as well as a novel optimisation and correlation algorithm to accurately fuse the data taken from quasi-static and continuous motion measurements. The measurement method allows for minimal quasi-static measurements to be taken while using a continuous motion measurement to enhance the calibration process with virtually no additional time constraints. The proposed method does not require any additional machine interfacing, making it a more readily accessible solution for widespread machine tool use than other techniques which require hardware links to the CNC. The result of which means a shorter calibration routine and enhanced results. The quasi-static and continuous motion measurements showed correlation to within 1 μm at the quasi-static measurement targets. An error of 13 μm was detailed on the continuous motion, but was missed using the standard test. On a larger, less accurate machine, the quasi-static and continuous motion measurements were on average within 3 μm of each other however, showed a standard deviation of 4 μm which is less than 1% of the overall error. Finally, a high frequency cyclic error was detected in the continuous motion measurement but was missed in the quasi-static measurement.  相似文献   

4.
A precise inclinometer (Talyvel 4) was adopted for evaluating aligning straightness of the first 71 m of the KEK electron/positron injector linear accelerator (linac). The straightness could be evaluated with a standard deviation of less than 49 μm. It is in good agreement with those obtained using a conventional alignment telescope and our laser-based alignment system.Error estimation based on the rules of error propagation shows that shape evaluation with a standard deviation of 0.3 mm for a distance of 500 m can be achieved using the proposed method. It indicates that this method is suitable for evaluating straightness of several hundred meters of linacs with sub-millimeter of accuracy.  相似文献   

5.
A shear mode micro-probing system was constructed for gap measurement of a precision slot die coater with a nominal gap width of 90 μm and a length of 200 mm. A glass micro-stylus with a nominal tip ball diameter of 52.6 μm was oscillated by a tuning fork quartz crystal resonator with its oscillation direction parallel to the measurement surfaces. An on-line qualification setup was established to compensate for the influences of the uncertainty sources, including the water layers on the measurement surfaces. The measurement uncertainty of the measured gap width was estimated to be less than 100 nm.  相似文献   

6.
A motorized 5 m tape comparator was constructed in TUBITAK UME for calibration of tapes and rules up to 5 m length in one set-up and further lengths in multiple set-ups. The system is a practical development and provides a cost effective solution for calibration of tapes in which the highest grade’s accuracy requirement in OIML R35-1 e.g. is 600 μm for 5 m length and 1100 μm for 10 m length. It is mainly composed of 6 m rail system, mechanical parts, optical units and an integrated 6 m incremental linear encoder as a reference measurement axis for traceable measurements. The rails are kinematically located on a heavy marble construction and a motorized carriage, which employs a camera for probing of the scales on the tapes, is moved along the rails during the measurement. The image of the scale taken by the camera is viewed on the monitor screen together with the running software. The operator can perform the probing process by simply moving the carriage over the measured scales (tapes or rules) using a joystick. The carriage movement is measured by the incremental linear encoder previously calibrated by a laser interferometer and the software automatically takes the measurement results from the incremental linear encoder, applies correction values previously defined and determines the length of the tapes and rules as well as deviations from nominal lengths. The estimated expanded uncertainty of the steel tape measurement is U = 54 μm in one set-up (for 5 m length) and U = 77 μm in two set-ups (for 10 m length) at the confidence level of approximately 95%. Uncertainty budget for calibration of the device itself and for calibration of the test tapes are explained in detail. The results of extensive experimental work and analysis are provided by demonstrating application of science and technology of measurement and instrumentation. Investigations for long term stability of the system are given with the reported test results for the years of 2003-2011 and participated intercomparison results to validate the device scientifically are illustrated.  相似文献   

7.
This paper proposes a non-contact pulsed interferometer for dimensional metrology using the repetition frequency of an optical frequency comb. A compact absolute-length measuring system is established for practical non-contact measurement based on a single-mode fiber interferometer. The stability and accuracy of the measurements are compared with those from a commercial incremental laser interferometer. The drifts of both systems have the same tendency and a maximum difference is approximately 0.1 μm. Subsequently, preliminary absolute-length measurements up to 1.5 m were measured. The signal-to-noise ratios of the small signals are improved by a frequency-selective amplifier. It is apparent that the noise is rejected, and the intensity of the interference fringes is amplified, achieving a maximum standard deviation of measurement approximately 1 μm. The proposed technique can provide sufficient accuracy for non-contact measurement in applications such as a simple laser-pulse tracking system.  相似文献   

8.
This research investigates the effects of flow pattern and salinity of oil-water two-phase flow on water holdup measurement using a conductance method. Firstly, vertical upward oil-water two-phase flow experiment is conducted in a 20 mm inner diameter (ID) pipe, in which the salinities of aqueous solutions are set as 151 ppm, 1003 ppm, 2494 ppm and 4991 ppm respectively. Experimental water-cut and mixture velocity are set as 80–100% and 0.0184–0.2576 m/s. In the experiment, three different flow patterns, i.e., dispersed oil-in-water slug flow (D OS/W), dispersed oil-in-water flow (D O/W) and very fine dispersed oil-in-water flow (VFD O/W) are observed and recorded by a high speed camera. Meanwhile, we collect the response of Vertical Multiple Electrode Array (VMEA) conductance sensor excited by a sine voltage signal. The result shows that, for VFD O/W, the water holdup from VMEA sensor shows a satisfied agreement with that of quick closing valve (QCV) method under certain salinities, i.e., 1003 ppm as well as 2494 ppm. For D OS/W flow and D O/W flow characterized by dispersed oil droplets with various sizes, considerable deviations of water holdup between VMEA sensor and QCV method under four kinds of salinity aforementioned are presented. Afterward, according to experimental analysis along with theoretical deviation, it is concluded that the deviation of the measurement system reaches its minimum when reference resistance in the measurement circuit and salinity of the aqueous solution satisfy constraint conditions, and the accuracy of water holdup using the conductance method can be improved through adjusting reference resistance to match the salinity of water phase. Finally, the recurrence plot algorithm is utilized to identify typical flow patterns mentioned above and it shows satisfied results on comprehending the discrepancies among different flow patterns, demonstrating that the recurrence plot algorithm can be effectively applied in flow pattern identification regarding oil-water flows.  相似文献   

9.
Large-scale rotors in the paper and steel industry are called rolls. Rolls are reground at regular intervals and roundness measurements are made throughout the machining process. Measurement systems for roundness and diameter variation of large rolls (diameter <2000 mm) are available on the market, and generally use two to four sensors and a roundness measurement algorithm. These methods are intended to separate roundness of the rotor from its movement. The hybrid four-point method has improved accuracy, even for harmonic component amplitudes. For reliable measurement results, every measurement should be traceable with an estimation of measurement uncertainty. In this paper, the Monte-Carlo method is used for uncertainty evaluation of the harmonic components of the measured roundness profile under typical industrial conditions. According to the evaluation, the standard uncertainties for the harmonic amplitudes with the hybrid method are below 0.5 μm for the even harmonics and from 1.5 μm to 2.5 μm for the odd harmonics, when the standard uncertainty for the four probes is 0.3 μm each. The standard uncertainty for roundness deviation is 3.3 μm.  相似文献   

10.
A simplified technique using short term Fourier transform to reduce the errors in distributed temperature measurement with a Raman scattering based optical fiber sensor system is presented. The two main sources of errors are differential attenuation to anti-Stokes and Stokes signal by fiber and local change in Stokes due to change in temperature. The proposed technique compensates these errors and extracts correct temperature profile in spite of practical difficulties encountered in applying the theoretical concept. Moreover proposed technique is less complex, self-reliant, can tolerate variation in laser power, requires less dead zone and suits automation using embedded solution. Results of measurement carried out, using the system developed at RRCAT, Indore, for two hot zones having spatial width of 1.9 m (kept at 56 °C) and 1.5 m (kept at 78 °C), located at 47 m and 85 m respectively, show that these parameters can be recovered with significantly small errors.  相似文献   

11.
This paper presents a new optical method of coordinate measuring machine (CMM) verification. The proposed system based on a single-mode fiber optical-comb pulsed interferometer with a ball lens of refractive index 2 employed as the target. The target can be used for absolute-length measurements in all directions. The laser source is an optical frequency comb, whose repetition rate is stabilized by a rubidium frequency standard. The measurement range is confirmed to be up to 10 m. The diagonals of a CMM are easier to verify by the proposed method than by the conventional artifact test method. The measurement uncertainty of the proposed method is also smaller than that of the conventional method because the proposed measurement system is less affected by air temperature; it achieves an uncertainty of approximately 7 μm for measuring lengths of 10 m. The experimental results show that the measurement accuracy depends on noise in the interference fringe, which arises from airflow fluctuations and mechanical vibrations.  相似文献   

12.
《Measurement》2007,40(7-8):797-802
A deadweight-type torque standard machine of 20 kN m rated capacity (20 kN m-DWTSM) has been designed and developed by the National Metrology Institute of Japan (NMIJ) at the National Institute of Advanced Industrial Science and Technology (AIST). Each uncertainty contribution comes mainly from the performance of each mechanical part of the 20 kN m-DWTSM. Authors evaluated the uncertainty of the mass of the linkage weights, local acceleration of gravity, influence of air buoyancy on deadweight loading, initial moment-arm length (including CMM measurement and temperature compensation), and sensitivity of the fulcrum. This report deals especially with evaluation of the remaining contributions, namely the influence of arm flexure and reference line variation at the end of the moment-arm on best measurement capability (BMC). Estimation of BMC in the 20 kN m-DWTSM gave a relative expanded uncertainty of less than 7.0 · 10−5 (k = 2) for the calibration range from 200 N m to 20 kN m.  相似文献   

13.
This paper describes the optimisation of a nano-positioning stage for a Transverse Dynamic Force Microscope (TDFM). The nano-precision stage is required to move a specimen dish within a horizontal region of 1 μm × 1 μm and with a resolution of 0.3 nm. The design objective was to maximise positional accuracy during high speed actuation. This was achieved by minimising out-of-plane distortions and vibrations during actuation. Optimal performance was achieved through maximising out-of-plane stiffness through shape and material selection as well optimisation of the anchoring system. Several shape parameters were optimised including the shape of flexural beams and the shape of the dish holder. Physical prototype testing was an essential part of the design process to confirm the accuracy of modelling and also to reveal issues with manufacturing tolerances. An overall resonant frequency of 6 kHz was achieved allowing for a closed loop-control frequency of 1.73 kHz for precise horizontal motion control. This resonance represented a 12-fold increase from the original 500 Hz of a commercially available positioning stage. Experimental maximum out-of-plane distortions below the first resonance frequency were reduced from 0.3 μm for the first prototype to less than 0.05 μm for the final practical prototype.  相似文献   

14.
This article investigates a kind of method to measure the wind speed and the wind direction, which is based on arc ultrasonic sensor array and combined with array signal processing algorithm. In the proposed method, a new arc ultrasonic array structure is introduced and the array manifold is derived firstly. On this basis, the measurement of the wind speed and the wind direction is analyzed and discussed by means of the basic idea of the classic MUSIC (Multiple Signal Classification) algorithm, which achieves the measurements of the 360° wind direction with resolution of 1° and 0–60 m/s wind speed with resolution of 0.1 m/s. The implementation of the proposed method is elaborated through the theoretical derivation and corresponding discussion. Besides, the simulation experiments are presented to show the feasibility of the proposed method. The theoretical analysis and simulation results indicate that the proposed method has superiority on anti-noise performance and improves the wind measurement accuracy.  相似文献   

15.
The flatness measurement of large and thin wafers is affected greatly by gravity. Inverting method is often used to cancel the effect. However, it is required that the positions of the supports and wafers are perfectly symmetric about the inversion axis. In this study a three-point-support method based on position determination of supports and wafers was proposed. The supporting balls and the wafer were placed in arbitrary positions and their positions were obtained by measurement and fed into the FEM model which was developed to calculate the gravity-induced deflection (GID). The methods to acquire the positions of the supports and the wafer were proposed. The position measurement accuracy of the supports was improved greatly by circle fitting to the profile of the supporting ball. Wafer edge point was obtained accurately as the intersection point between the wafer surface line and the edge profile. The method to measure the wafer thickness using only one displacement sensor on the same equipment was presented. The simulation results were verified by experimental results. The centering device for the wafer and the positioning accuracy requirements of the supports are not needed any more. The effect of the positions of the supports and the wafer was reduced to be less than 1 μm for a 300 mm diameter and 397 μm thickness wafer with GID over 140 μm. This method could also be used for accurate flatness measurement of other large and thin panels.  相似文献   

16.
The present paper describes a moving permanent magnet linear synchronous motor (MPM LSM) that can move with an acceleration above 100 G (=980 m/s2), and is also capable of high-precision and high-speed positioning. The MPM LSM consists of a mover including permanent magnets and a double-sided electromagnet stator. It can produce a thrust of 4.56 × 103 N and has a working range wider than 1 m. The MPM LSM mover is improved for light weight and is driven using a suitable phase lead for flux weakening. The combination of the improved mover and the suitable phase lead provides motion at an acceleration above 100 G and a velocity above 12 m/s. The positioning characteristics of the improved MPM LSM are examined using a controller with two suitable phase lead functions. The control system shows a positioning accuracy and a positioning resolution of 500 nm, which is similar to the vibration amplitude of the sensor output in open loop. In 300-mm step positioning, the improved MPM LSM shows an acceleration above 660 m/s2 and a velocity above 8.3 m/s. It takes less than 101 ms to reduce the positioning error to less than 5 μm. The temperature rise during positioning is also examined experimentally. Continuous positioning for longer than 30 minutes increases the temperature of the MPM LSM, but by less than 6 °C.  相似文献   

17.
A compact and inexpensive iodine-stabilized diode laser system with an output at 531 nm has been applied to long gauge block measurements. Although the optical frequency of the output beam was widely modulated (modulation width of ∼22 MHz), the coherence length and interference phase stability are sufficiently long and high, respectively, for the interferometric measurement of long gauge blocks of up to 1000 mm in length. The effective uncertainty of laser frequency in the interferometric measurement was theoretically and experimentally confirmed to be less than 10−9.  相似文献   

18.
The remote distance measurement (RDM) method requires only common total stations and not special post-processing software. Moreover, this method is easy to operate and highly accurate results can be obtained. Therefore, RDM is used in the displacement monitoring of tunnel engineering. This study presents the calculation formulas for the crown settlement and wall convergence of tunnel as measured by RDM with total station. The mean error formulas are derived based on error propagation laws. When tunnel displacements measured by using total station with the ms not more than 2 mm + 2D ppm (D is the measurement distance) and mα not more than 1″, the horizontal distance between the rear viewpoint and the monitoring section is in the range of 50–150 m, the horizontal distance between the total station and the monitoring section ranges from 40 m to 60 m, and the total station is near the tunnel centerline, the measurement accuracy can reach 1 mm.  相似文献   

19.
A differential interferometric heterodyne encoder with spatially separated input beams was developed to minimize periodic nonlinearities resulting from polarization mixing. The laser beams with different frequencies were delivered by two polarization-maintaining fibers to the encoder head. Under laboratory conditions this encoder demonstrated a system stability of 38 pm (standard deviation) and 100 pm over 30 s and 1 h respectively. In a comparison measurement with a differential heterodyne interferometer, this encoder showed periodic nonlinearities of less than 30pm without any additional correction.  相似文献   

20.
In ISO 14405-1, the global sizes, such as least-squares diameter, minimum circumscribed diameter and maximum inscribed diameter are defined. The diameters above can be measured by using cylindrical coordinate measuring method like the circular section measuring method of cylindricity error. The determination method of the least-squares diameter was firstly given based on the cylindrical measuring system, and the optimization models of the minimum circumscribed diameter and the maximum inscribed diameter were built, respectively. The corresponding objective functions were unified as “minimax” expressions. For the four axis parameters of the cylinder with the minimum circumscribed diameter or the maximum inscribed diameter, the searching ranges of cylinder’s axis parameters for their optimal solutions were defined numerically. Thereafter, the genetic, steepest decent and BFGS-0.618 algorithms were introduced, and the optimization evaluation algorithms of two kinds of diameters mentioned above were given. Based on many cylinders’ profiles obtained by the circular section measuring method on a measuring instrument of cylinder’s global sizes which was developed by Zhongyuan University of Technology, Zhengzhou, China. The accuracy, efficiency and suitability of three optimization algorithms were investigated through the evaluation of a lot of the minimum circumscribed diameters and the maximum inscribed diameters. The measurement uncertainty of the global sizes for the cylindrical specimen was analyzed, and the measurement uncertainties of the sizes in the radial and z directions are ±0.95 μm and ±0.5 μm, respectively. The total measurement uncertainties of the global sizes of the cylindrical specimens with the specifications of ϕ10 × 120 mm and ϕ100 × 300 mm are ±3.8 μm and ±5.7 μm, respectively. The investigation results showed that for the evaluation of the globe sizes, any one of three algorithms above is not absolutely prior to the other two algorithms while considering both evaluation accuracy and efficiency, and the difference of their evaluation results do not exceed 0.5 μm. On the other hand, many points between the maximum value and the least value do not affect the evaluation results in optimization process. For improving the evaluation efficiency, by de-selecting those points while considering the characteristic parameter was also studied based on the statistic method and experiment. Coefficient t should be less than 0.3 to ensure the evaluation accuracy. This research may be useful for developing the next generation measurement instrument for the global sizes and the way forward for the digital manufacturing.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司    京ICP备09084417号-23

京公网安备 11010802026262号