首页 | 官方网站   微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 125 毫秒
1.
In this study, the improvement in the removal of chlorobenzene (C6H5Cl) in the air was investigated by combining dielectric barrier discharge (DBD) driven by bipolar pulse-power with catalysts. Molecular sieve 4A (MS-4A) and MnO2/γ-Al2O3 (MnO2/ALP) as two kinds of catalysts were tested at different positions in a DBD reactor. Catalysts were located either in the discharging area between two electrodes, or just behind the discharging area (in the afterglow area) closed to the outlet. The results indicated that DBD reactor with a bipolar pulse power-supply produced strong instant discharge and energetic particles, which can effectively activate catalysts of MS-4A and MnO2/ALP located in the afterglow area to achieve the synergistic effects on effective fission of chemical bonds of chlorobenzene. It was considered that the gas-chlorobenzene and the chlorobenzene adsorbed on the catalysts were decomposed simultaneously.  相似文献   

2.
Two plasma reactors have been developed and used to degrade dye wastewater agents.The configuration of one plasma reactor is a comb-like extendable unit module consisting of 5 electrodes covered with a quartz tube and the other one is an array reactor which is extended from the unit module.The decomposition of wastewater by ns pulse dielectric barrier discharge(DBD) plasma have been carried out by atomizing the dyeing solutions into the reactors.During experiments,the indigo carmine has been treated as the waste agent.The measurements of UV-VIS absorption spectroscopy and the chemical oxygen demand(COD) are carried out to demonstrate the decomposition efect on the wastewater.It shows that the decoloration rate of 99% and the COD degradation rate of 65% are achieved with 15 min treatment in the unit reactor.The efect of electrical parameters on degradation has been studied in detail.Results from the array reactor indicate that it has a better degradation efect than the unit one.It can not only totally remove the chromogenic bond of the indigo carmine solution,but also efectively degrade unsaturated bonds.The decoloration rate reaches 99% after 10 min treatment,the decomposition rate of the unsaturated bond reaches 83% after 60 min treatment,and the COD degradation rate is nearly 74%.  相似文献   

3.
A wastewater treatment system was established by means of pulsed dielectric barrier discharge(DBD). The main advantage of this system is that the wastewater is employed as one of the electrodes for the degradation of rhodamine B, which makes use of the high conductivity and lessenes its negative influence on the discharge process. At the same time, the reactive species like ozone and ultraviolet(UV) light generated by the DBD can be utilized for the treatment of wastewater. The effects of some factors like conductivity, peak pulse voltage, discharge frequency and pH values were investigated. The results show that the combination of these reactive species could enhance the degradation of the dye while the ozone played the most important role in the process. The degradation efficiency was enhanced with the increase of energy supplied. The reduction in the concentration of rhodamine B was much more effective with high solution conductivity;under the highest conductivity condition, the degradation rate could rise to 99%.  相似文献   

4.
A dielectric barrier discharge (DBD) reactor with a rod-plate electrode configuration was used for the oxidative decomposition of Congo red dye in an aqueous solution.Plasma was generated in the gas space above the water interface under atmospheric pressure.Discharge characteristics were analyzed by voltage-current waveforms.Effects of applied voltage,initial conductivity,and initial concentration were also analyzed.Congo red discoloration increased with increased applied voltage and decreased conductivity.The initial conductivity significantly influenced the Congo red discoloration.Under the same conditions,the highest discoloration rate was obtained at 25 mg/L.The presence of ferrous ions in the solutions had a substantial positive effect on Fenton dye degradation and flocculation.At an applied voltage of 20 kV,about 100%of dye was degraded after 4 min of Fe2+/DBD treatment.Results showed that adding a certain dosage of hydrogen peroxide to the wastewater could enhance the discoloration rate.Possible pathways of Congo red discoloration by DBD plasma were proposed based on GC/MS,FTIR,and UV-vis spectroscopy analyses.  相似文献   

5.
A gas-phase surface discharge (GSD) was employed to optimize the discharge reactor structure and investigate the dye degradation. A dye mixture of methylene blue, acid orange and methyl orange was used as a model pollutant. The results indicated that the reactor structure of the GSD system with the ratio of tube inner surface area and volume of 2.48, screw pitch between a high-voltage electrode of 9.7 mm, high-voltage electrode wire diameter of 0.8 mm, dielectric tube thickness of 2.0 mm and tube inner diameter of 16.13 mm presented a better ozone (O3) generation efficiency. Furthermore, a larger screw pitch and smaller wire diameter enhanced the O3 generation. After the dye mixture degradation by the optimized GSD system, 73.21% and 50.74% of the chemical oxygen demand (COD) and total organic carbon removal rate were achieved within 20 min, respectively,and the biochemical oxygen demand (BOD) and biodegradability (BOD/COD) improved.  相似文献   

6.
Non-thermal plasma(NTP) is considered to be a promising technology for the removal of volatile organic compounds; however, its application is limited by low CO2selectivity and undesirable by-products. To overcome these issues, this paper discusses the degradation of chlorobenzene(CB) in systems of NTP coupled with catalysts, and the influence of catalyst locations in the NTP was investigated. In addition, the interaction between plasma and catalyst was also explored. The results indicated that t...  相似文献   

7.
A combined method of granular activated carbon (GAC) adsorption and bipolar pulse dielectric barrier discharge (DBD) plasma regeneration was employed to degrade phenol in water. After being saturated with phenol, the GAC was filled into the DBD reactor driven by bipolar pulse power for regeneration under various operating parameters. The results showed that different peak voltages, air flow rates, and GAC content can affect phenol decomposition and its major degradation intermediates, such as catechol, hydroquinone, and benzoquinone. The higher voltage and air support were conducive to the removal of phenol, and the proper water moisture of the GAC was 20%. The amount of H2O2 on the GAC was quantitatively determined, and its laws of production were similar to phenol elimination. Under the optimized conditions, the elimination of phenol on the GAC was confirmed by Fourier transform infrared spectroscopy,and the total removal of organic carbons achieved 50.4%. Also, a possible degradation mechanism was proposed based on the HPLC analysis. Meanwhile, the regeneration efficiency of the GAC was improved with the discharge treatment time, which attained 88.5% after 100 min of DBD processing.  相似文献   

8.
Co-based catalysts were prepared by using dielectric-barrier discharge (DBD) plasma as an alternative method to conventional thermal calcination. The characterization results of N2-physisorption, temperature programmed reduction (TPR), transmission electron microscope (TEM), and X-ray diffraction (XRD) indicated that the catalysts prepared by DBD plasma had a higher specific surface area, lower reduction temperature, smaller particle size and higher cobalt dispersion as compared to calcined catalysts. The DBD plasma method can prevent the sintering and aggregation of active particles on the support due to the decreased treatment time (0.5 h) at lower temperature compared to the longer thermal calcination at higher temperature (at 500℃ for 5 h). As a result, the catalytic performance of the Fischer-Tropsch synthesis on DBD plasma treated Co/SiO2 catalyst showed an enhanced activity, C5+ selectivity and catalytic stability as compared to the conventional thermal calcined Co/SiO2 catalyst.  相似文献   

9.
Electric discharge in water can generate a large number of oxidants such as ozone, hydrogen peroxide and hydroxyl radicals. In this paper, a non-thermal plasma processing system was established by means of pulsed dielectric barrier discharge in gas-liquid phase. The electrodes of discharge reactor were staggered. The yield of H2O2 was enhanced after discharge. The effects of discharge time, discharge voltage, frequency, initial pH value, and feed gas were investigated. The concentration of hydrogen peroxide and ozone was measured after discharge. The experimental results were fully analyzed. The chemical reaction equations in water were given as much as possible. At last, the water containing Rhodamine B was tested in this system. The degradation rate came to 94.22% in 30 min.  相似文献   

10.
The experiment was carried out in a cylindrical dielectric barrier discharge(DBD)reactor assisted with a catalyst to decompose toluene under different humidity.In order to explore the synergistic effect on removing toluene in the catalysis-DBD reactor,this paper investigated the decomposition efficiency and the energy consumption in the catalysis-DBD and the non-catalyst DBD reactors under different humidity.The results showed that the catalysis-DBD reactor had a better performance than the non-catalysis one at the humidity ratio of 0.4%,and the removal efficiency of toluene could reach 88.6% in the catalysis-DBD reactor,while it was only 59.9% in the non-catalytic reactor.However,there was no significant difference in the removal efficiency of toluene between the two reactors when the humidities were 1.2% and 2.4%.Additionally,the degradation products were also analyzed in order to gain a better understanding of the mechanism of decomposing toluene in a catalysis-DBD reactor.  相似文献   

11.
A system based on dielectric barrier discharge (DBD) with improved discharge sta- bility and homogeneity was used for the degradation of Alizarin Red (AR). This special structure of the DBD system is characterized by the high voltage electrode, which is covered with a quartz tube and partially immersed in water, and by directly using the water as the ground electrode. A transition was realized from the filamentary mode for the conventional structure of the DBD to the semi-homogeneous mode for such a configuration of the plasma discharge. The spectra of plasma are dominated by N2 molecular lines in the ultraviolet-A radiation region. Plasma degra- dation of AR in this system exhibited pseudo-first-order reaction kinetics. The degradation rate of AR reached 95% or so after 14 min treatment under favorable conditions. Alkaline conditions are favorable for the degradation of AR. The increase of conductivity of the solution, input power and usage of oxygen bubbling could enhance AR degradation.  相似文献   

12.
The organic compounds of p-nitrophenol (PNP) solution was treated by the active species generated in a stirred reactor by an atmospheric pressure plasma jet (APPJ). The emission intensities of hydroxyl (OH), oxygen (O), nitric oxide (NO), hydrogen (H) and molecular (N2) were measured by optical emission spectroscopy (OES). The relations between the flow rates of the PNP solution and degradation, the degradation effects and initial pH value of the solution were also investigated. Experimental results show that there exist intense emissions of O (777.1 nm), N(337.1 nm), OH (306-310 nm) and NO band (200-290 nm) in the region of plasma. Given the treatment time and gas flow rate, the degradation increased as a function of discharge energy and solution flow rate, respectively. The solution flow rate for the most efficient degradation ranged from 1.414 m/s to 1.702 m/s, and contributed very little when it exceeded 2.199 m/s. This indicates the existence of diffusion-controlled reactions at a low solution flow rate and activation- controlled reactions at a high solution flow rate. Moreover, increasing or decreasing the initial pH value of neutral PNP solution (pH=5.95) could improve the degradation efficiency. Treated by APPJ, the PNP solutions with different initial pH values of 5.95, 7.47 and 2.78 turned more acidic in the end, while the neutral solution had the lowest degradation efficiency. This work clearly demonstrates the close coupling of active species, photolysis of ultraviolet, the organic solution flow rate and the initial pH value, and thus is helpful in the study of the mechanism and application of plasma in wastewater treatment.  相似文献   

13.
The destruction of gaseous styrene was studied using a low-temperature plasma induced by tubular multilayer dielectric barrier discharge(DBD).The results indicate that the applied voltage,gas flow rate,inlet styrene concentration and reactor configuration play important roles in styrene removal efficiency(η_(styrene)) and energy yield(EY).Values of η_(styrene) and EY reached 96%and 15567 mg/kWh when the applied voltage,gas flow rate,inlet styrene concentration and layers of quartz tubes were set at 10.8 kV,5.0 m/s,229 mg/m~3 and 5 layers,respectively.A qualitative analysis of the byproducts and a detailed discussion of the reaction mechanism are also presented.The results could facilitate industrial applications of the new DBD reactor for waste gas treatment.  相似文献   

14.
To get an optimized pulsed electrical plasma discharge reactor and to increase the energy utilization efficiency in the removal of pollutants, two hybrid plasma discharge reactors were designed and optimized. The reactors were compared via the discharge characteristics, energy transfer efficiency, the yields of the active species and the energy utilization in dye wastewater degradation. The results showed that under the same AC input power, the characteristics of the discharge waveform of the point-to-plate reactor were better. Under the same AC input power, the two reactors both had almost the same peak voltage of 22 kV. The peak current of the point-to-plate reactor was 146 A, while that of the wire-to-cylinder reactor was only 48.8 A. The peak powers of the point-to-plate reactor and the wire-to-cylinder reactor were 1.38 MW and 1.01 MW, respectively. The energy per pulse of the point-to-plate reactor was 0.2221 J, which was about 29.4% higher than that of the wire-to-cylinder reactor (0.1716 J). To remove 50% Acid Orange 7 (AO7), the energy utilizations of the point-to-plate reactor and the wire- to-cylinder reactor were 1.02×10^-9 mol/L and 0.61×10^-9 mol/L, respectively. In the point-to- plate reactor, the concentration of hydrogen peroxide in pure water was 3.6 mmol/L after 40 min of discharge, which was higher than that of the wire-to-cylinder reactor (2.5 mmol/L). The concentration of liquid phase ozone in the point-to-plate reactor (5.7×10^-2 mmol/L) was about 26.7% higher than that in the wire-to-cylinder reactor (4.5×10^-2 mmol/L). The analysis results of the variance showed that the type of reactor and reaction time had significant impacts on the yields of the hydrogen peroxide and ozone. The main degradation intermediates of AO7 identified by gas chromatography and mass spectrometry (GCMS) were acetic acid, maleic anhydride, p- benzoquinone, phenol, benzoic acid, phthalic anhydride, coumarin and 2-naphthol. Proposed degradation pathways were elucidated in light of the ana  相似文献   

15.
Dielectric barrier discharge (DBD) plasma was utilized to oxidize NO contained in the exhaust gas to NO2, ultimately improve the selective catalytic reduction of nitrogen oxides (NOx). In the one case, DBD was created directly in the exhaust gas (direct application), and in the an other case, ozone produced by DBD was injected into the exhaust gas (indirect application). A comparative study between such direct and indirect applications of DBD plasma was made in terms of the NOx removal efficiency and the energy consumption. The NO2 content in the exhaust gas was changed by the voltage applied to the DBD device (for direct application) or by the amount of ozone added to the exhaust gas (for indirect application). In both cases, NO was easily oxidized to NO2, and the change in NO2 content largely affected the NOx removal performance of the catalytic reactor placed downstream, where both NO and NO2 were reduced to N2 in the presence of ammonia as the reducing agent. The experiments were primarily concerned with the effect of reaction temperature on the catalytic NOx reduction at various NO2 contents. The direct and indirect applications of DBD were found to remarkably improve the catalytic NOx reduction, especially at low temperatures.  相似文献   

16.
Polybrominated diphenyl ethers (PBDEs) spread widely in the environment are mainly removed by photochemical and anaerobic microbial degradation. In this paper, the decomposition of 4-bromodiphenyl ether (BDE -3), the PBDEs homologues, is investigated by electron beam irradiation of its ethanol/water solution (reduction system) and acetonitrile/water solution (oxidation system). The radiolytic products were determined by GC coupled with electron capture detector, and the reaction rate constant of esol– in the reduction system was measured at 2.7×1010 L·mol–1·s–1 by pulsed radiolysis. The results show that the BDE-3 concentration affects strongly the decomposition ratio in the alkali solution, and the reduction system has a higher BDE-3 decomposition rate than the oxidation system. This indicates that the BDE-3 was reduced by effectively capturing esol– in radiolytic process.  相似文献   

17.
18.
Quinoline is widely used in the production of drugs as a highly effective insecticide, and its derivatives can also be used to produce dyes. It has a teratogenic carcinogen to wildlife and humans once entering into the aquatic environment. In this study, the degradation mechanism of quinoline in drinking water by a strong ionization dielectric barrier discharge(DBD) lowtemperature plasma with large volume was explored. High concentration of hydroxyl radical(·OH)(0.74 mmol l-1) and ozone(O3)(58.2 mg l-1) produced by strongly ionized discharge DBD system were quantitatively analyzed based on the results of electron spin resonance and O3 measurements. The influencing reaction conditions of input voltages, initial p H value, ·OH inhibitors, initial concentration and inorganic ions on the removal efficiency of quinoline were systematically studied. The obtained results showed that the removal efficiency and TOC removal of quinoline achieved 94.8% and 32.2%, degradation kinetic constant was 0.050 min-1 at 3.8 k V and in a neutral p H(7.2). The proposed pathways of quinoline were suggested based on identified intermediates as hydroxy pyridine, fumaric acid, oxalic acid, and other small molecular acids by high-performance liquid chromatography/tandem mass spectrometry analysis. Moreover, the toxicity analysis on the intermediates demonstrated that its acute toxicity, bioaccumulation factor and mutagenicity were reduced. The overall findings provided theoretical and experimental basis for the application of a high capacity strong ionization DBD water treatment system in the removal of quinoline from drinking water.  相似文献   

19.
In this study, we report on the degradation of microcystin-LR (MC-LR) by gas- liquid interracial discharge plasma. The influences of operation parameters such as average input voltage, electrode distance and gas flow rate are investigated. Experimental results indicate that the input voltage and gas flow rate have positive influences on MC-LR degradation, while the electrode distance has a negative one. After 6 min discharge with 25 kV average input voltage and 60 L/h air aerati by discharge both in on, the degradation rate of MC-LR achieves 75.3%. distilled water and MC-LR solution are measured H202 and 03 generated Moreover, an emission spectroscopy is used as an indicator of the processes that take place on the gas-liquid boundary and inside plasma. Varied types of radicals (O, .OH, CO, 03, etc.) are proved to be present in the gas phase during gas-liquid interfacial discharge.  相似文献   

20.
A combined plasma photolysis(CPP) reactor that utilized the dielectric barrier discharge(DBD) plasma together with DBD-driven KrI excimer ultraviolet emission was applied to the decomposition of H 2 S gas.The effects of applied voltage,input current,gas flow velocity,original concentration as well as the ratio of Kr/I 2 mixture on H 2 S removal efficiency were investigated.Gas streams containing H 2 S were separately treated with single DBD and CPP reactor under the same conditions.In comparison to DBD,CPP could greatly enhance the H 2 S removal efficiency at the same applied voltage,inlet gas concentration and gas flow velocity.In addition,the reaction mechanism was also discussed in this paper.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司    京ICP备09084417号-23