1.
全厂断电事故下AP1000非能动余热排出系统分析   总被引:6,自引:5,他引:1  
利用RELAP5/MOD3.3程序对AP1000反应堆一回路及非能动系统进行建模计算,给出了AP1000非能动余热排出系统(PRHRS)在全厂断电事故下的瞬态响应特性。计算结果表明:情况1,PHRH系统由蒸汽发生器低水位与低启动给水流量符合信号启动,稳压器安全阀的开启导致PRHRS发生倒流现象,并会引起堆芯冷却剂过热沸腾、压力容器进出口温差过大等后果;情况2,由断电信号直接触发PRHRS,触发前安全阀不开启,此时PRHRS正常运行。  相似文献   

2.
假设AP1000核电厂发生类似福岛核事故的初因事件,利用RELAP5/MOD3.3程序对事故早期的一、二回路系统和非能动安全系统进行模拟计算,得到了反应堆冷却剂系统压力、堆芯冷却剂温度、非能动安全系统流量等重要参数的瞬态变化。分析表明:在非能动余热排出系统完好的情况下,反应堆系统能顺利进入热停堆状态;如果非能动余热排出系统1根换热管发生双端断裂,则反应堆系统将会在5 h内发生严重事故。  相似文献   

3.
There are many differences between the flow and heat transfer characteristics of nuclear reactors under ocean and land-based conditions for the effects of ocean waves. In this paper, thermal hydraulic characteristics of a passive residual heat removal system (PRHRS) for an integrated pressurized water reactor (IPWR) in ocean environment were investigated theoretically. A series of reasonable theoretical models for a PRHRS in an IPWR were established. These models mainly include the core, once-through steam generator, nitrogen pressurizer, main coolant pump, flow and heat transfer and ocean motion models. The flow and heat transfer models are suitable for the core with plate-type fuel element and the once-through steam generator with annular channel, respectively. A transient analysis code in FORTRAN 90 format has been developed to analyze the thermal–hydraulic characteristics of the PRHRS under ocean conditions. The code was implemented to analyze the effects of different ocean motions on the transient thermal-hydraulic characteristics of PRHRS. It is found that the oscillating amplitudes and periods of the system parameters are determined by those of the ocean motions. The effect of rolling motion is more obvious than that of pitching motion when the amplitudes and periods of rolling and pitching motions are the same. The obtained analysis results are significant to the improvement design of the PRHRS and the safety operation of the IPWR.  相似文献   

4.
小型铅铋快堆的非能动余热排出系统(PRHRS)主要是为应对全厂断电(SBO)事故,但目前并不确定该PRHRS能否有效带走堆芯衰变热以保证堆芯安全,因此开展了数值分析研究评价PRHRS的余热排出能力。本文使用RELAP5 4.0程序开展了小型铅铋快堆SBO事故热工水力分析,首先进行稳态计算,之后将稳态结果作为初值进行瞬态计算。研究结果表明:在整个SBO事故中,包壳峰值温度最高为820 K,主容器与保护容器壁面最高温度分别为792 K和769 K,均未超过安全限值,表明此PRHRS可有效应对小型铅铋快堆SBO事故。本文研究可为小型铅铋快堆PRHRS的工程设计奠定技术基础。  相似文献   

5.
SAC-PREARS 是一个用于分析非能动RHRS稳态和瞬态安全特性的专用程序.通过实验验证的用于AC-600 非能动 RHRS安全分析的MISAP 程序,对SAC-PREARS程序进行了稳态计算验证.并应用SAC-PREARS程序对200 MW 核供热堆非能动RHRS稳态和瞬态热工水力特性进行了分析,得出了具有工程意义的结论.  相似文献   

6.
浮动式核电站长期在海洋环境中运行,各系统都会受到海洋运动条件的影响。非能动余热排出系统(PRHRS)可在核电站发生全厂断电事故的情况下带出堆芯衰变余热,防止堆芯熔化,是重要的反应堆辅助系统。本文以一种采用海水作为最终热阱的浮动式核电站作为研究对象,分别设计了一回路和二回路PRHRS,开展了静止和摇摆条件下反应堆系统发生全厂断电事故的计算,对两种PRHRS在静止和摇摆条件下的运行特性进行了分析。研究表明,静止条件二回路PRHRS具有更强的带热能力,摇摆条件下一回路PRHRS的带热能力更加稳定。  相似文献   

7.
以中国改进型压水堆核电站CPR1000为研究对象,在其蒸汽发生器二次侧设计了一套非能动余热排出系统(PRHRS),该系统采用在蒸汽发生器二次侧建立自然循环的方式间接带走堆芯余热,确保事故条件下堆芯安全。用RELAP5/MOD3.2程序对系统进行了合理的简化并建模,在全场断电(SBO)事故条件下模拟了PRHRS的瞬态响应过程,并对高位水箱的容积、PRHRS换热器的换热面积、冷热中心高度差以及PRHRS的投入时间等影响PRHRS工作特性的相关参数进行了敏感性分析。计算结果表明:增加高位水箱的容积和增大换热面积均有助于二次侧余热排出系统带走一回路的堆芯余热;降低冷热中心高度差对PRHRS的自然循环能力影响不大;余热排出系统投入时间越早,蒸汽发生器二次侧水位越高,越有利于一次侧余热的排出。  相似文献   

8.
在一维质量、动量和能量守恒方程基础上建立了AP1000反应堆主冷却剂系统及非能动余热排出系统数学模型,并编制了用于该系统瞬态特性分析的动态仿真程序PRHRSDSC。模拟了非能动余热排出系统在全厂断电事故下的瞬态响应过程,并将计算结果与西屋公司的LOFTRAN程序结果进行对比。结果表明:系统可依靠自然循环有效导出堆芯余热,一回路冷却剂温度维持在过冷状态,峰值压力未超过运行压力限值,各参数的变化趋势符合良好,证明了建模的合理性。  相似文献   

9.
介绍了先进堆非能动余热排出系统综合试验研究的试验装置和冷热芯位差阈值研究结果、稳态试验研究结果、瞬态特性分析结果,以及MISAP2.0程序改进、验证结果。试验研究结果可为先进压水堆核电站非能动余热排出系统原型设计(系统布置、设备容量和系统启动方式等)提供试验依据,并为舰船核动力装置非能动余热排出系统的研究与设计提供可参考的试验数据,开发的具有自主知识产权的MISAP2.0程序为我国自行设计先进堆非能动余热排出系统提供了必要的设计手段。  相似文献   

10.
An investigation of the thermal hydraulic characteristics and the natural circulation performance in the passive residual heat removal system (PRHRS) for an integral type reactor have been carried out using the VISTA facility and the calculated results using the MARS code, which is a best estimate system analysis code have been compared with the experimental results. The VISTA facility consists of the primary, secondary, and the PRHRS circuits, to simulate the SMART design verification program. The experimental results show that the fluid is well stabilized in the PRHRS loop and the PRHRS heat exchanger accomplishes well its functions in removing the transferred heat from the primary side in the steam generator as long as the heat exchanger is submerged in the water in the emergency cooldown tank (ECT). The decay heat and the sensible heat can be sufficiently removed from the primary loop with the operation of the PRHRS. The MARS code predicts reasonably well the characteristics of the natural circulation in the PRHRS. From the calculation results, most of the heat transferred from the primary system is removed at the PRHRS heat exchanger by a condensation heat transfer.  相似文献   

11.
为研究海洋条件对海上浮动堆全厂断电事故后的事故进程及非能动安全系统运行特性的影响,通过建立海洋条件加速度场模型,基于RELAP5程序开发获得了适用于海上浮动堆的系统分析程序,并对程序进行了实验验证。利用所开发的程序通过建立双环路海上浮动堆及二次侧非能动余热排出系统的计算模型,开展了不同摇摆运动参数下海上浮动堆全厂断电事故的计算分析。计算结果表明,船体的横摇运动可加快全厂断电事故后浮动堆系统压力和温度的下降速度,堆芯余热能够被二次侧非能动余热排出系统有效导出;但横摇运动会造成事故后堆芯自然循环流量的显著降低,引起一回路系统和非能动余热排出系统中自然循环流量的大幅度振荡及周期性倒流。本文计算结果可为海上浮动堆非能动安全系统的设计提供参考。  相似文献   

12.
An innovative design for Chinese pressurized reactor is the steam generator (SG) secondary side water cooling passive residual heat removal system (PRHRS). The new design is expected to improve reliability and safety of the Chinese pressurized reactor during the event of feed line break or station blackout (SBO) accident. The new system is comprised of a SG, a cooling water pool, a heat exchanger (HX), an emergency makeup tank (EMT) and corresponding valves and pipes. In order to evaluate the reliability of the water cooling PRHRS, an analysis tool was developed based on the drift flux mixture flow model. The preliminary validation of the analysis tool was made by comparing to the experimental data of ESPRIT facility. Calculation results under both high pressure condition and low pressure condition fitted the experimental data remarkably well. A hypothetical SBO accident was studied by taking the residual power table under SBO accident as the input condition of the analysis tool. The calculation results showed that the EMT could supply the water to the SG shell side successfully during SBO accident. The residual power could be taken away successfully by the two-phase natural circulation established in the water cooling PRHRS loop. Results indicate the analysis tool can be used to study the steady and transient operating characteristics of the water cooling PRHRS during some accidents of the Chinese pressurized reactor. The present work has very important realistic significance to the engineering design and assessment of the water cooling PRHRS for Chinese NPPs.  相似文献   

13.
黄昌蕃  匡波 《核安全》2012,(1):35-41,F0003
非能动安全系统可靠性的分析是广泛采用非能动设计的新一代核电厂概率安全评价(PSA)的重要内容,其量化分析需根据非能动安全系统可靠性评估对象,确定影响系统运行的关键参数,结合事件序列对非能动系统进行研究。本文以AP1000非能动余热排出系统(PRHRS)设计阶段的可靠性研究为例,结合丧失主给水事故,根据燃料包壳完整性以及系统稳定性的功能准则,确定影响PRHRS的关键参数和设计参数。采用拉丁超立方抽样(LHS)确定输入参数组合,运用RELAP5/MOD3程序进行不确定性传递计算,进行关键参数对系统功能敏感性评价与确认,进行系统功能可靠性分析,为AP1000概率安全评价提供PRHRS可靠性估计。  相似文献   

14.
上海应用物理研究所基于TRISO包覆球形颗粒燃料与液态氟盐提出了基于钍基熔盐固态试验堆(TMSR-SF1)技术方案,其中一个重要的工作是非能动余热排出系统(PRHRS)设计。由于熔盐与水的不兼容特性,以及其高运行温度,采用空气作为最终热阱来设计PRHRS成为必然。为实现系统最简化、体积最小化以及排热与保温兼顾的设计目标,本文从MSR堆芯活性区到外界空气热阱传热过程的模型入手,建立了PRHRS优化设计模型,获得了优化设计方案,并基于改进的RELAP5/MOD4.0程序(针对TMSR-SF1的专门改进程序)开展了PRHRS容量论证评价,经计算分析,PRHRS容量设计合理,可确保反应堆全厂断电(SBO)后排热安全。   相似文献   

15.
提出了一种新型非能动余热排出系统(PRHRS)设计方案,该方案以高位水箱为最终热阱,采用在蒸汽发生器二次侧建立自然循环的方式间接地带走堆芯余热。以大亚湾核电站主冷却剂系统为载体,用RELAP5/MOD3.2程序分析了全厂断电事故下,PRHRS的运行特性。结果表明:事故发生后,余热排出系统内可较快地建立起循环流动,带走蒸汽发生器二次侧热量,在一段时间内保证反应堆安全,证明系统设计合理、有效。并分析了换热器布置高度、系统投入时间及换热面积对余热排出系统运行特性的影响。  相似文献   

16.
Natural circulation characteristics of an integral type reactor during the operation of a passive residual heat removal system (PRHRS) following a safety related event has been experimentally investigated by using the VISTA facility. A PRHRS actuation trip signal is generated by a high power trip signal following a steam flow increasing event. The experimental results show that the single-phase coolant flows steadily in the primary loop by a natural convection process and that it effectively removes the decay heat from the core through a steam generator during the PRHRS operation. The heat transfers through the PRHRS heat exchanger and the emergency cooldown tank (ECT) are sufficient enough to enable a two-phase natural circulation of the coolant in the PRHRS loop.  相似文献   

17.
提出了一种新型非能动余热排出系统设计方案,该方案以密度锁技术作为基础,采用改变压力调节回路流量,并保持循环回路内有高温工质流动的方式,建立密度锁内水力平衡关系,维持主回路和余热排出回路的隔离。以AP1000主冷却剂系统为载体,用RELAP5/MOD32程序分析了正常工况下,非能动余热排出系统的运行特性。结果表明:以密度锁内流体温度作为控制变量对调压泵转速进行调节,可逐渐建立密度锁内水力平衡关系,实现非能动余热排出系统的启动;稳态运行期间,反应堆运行参数改变时,在控制系统反馈作用下,密度锁仍能维持“封闭”状态,保证主回路和余热排出回路隔离。  相似文献   

18.
Advanced small modular reactors (SMRs) use different design in the systems, structures, components from large reactors for achieving a high level of safety and reliability. In present work, the SMRs severe accident caused by the station blackout (SBO) was modeled and analyzed using MELCOR code, and the simulation of the accident scenario response to SBO was conducted. Based on the steady state calculation, which agrees well with designed values, we introduced the SBO accident for transient calculation. First, the case of the SBO accident without the passive core cooling system (PXS) was calculated. The progression and scenario in the reactor pressure vessel (RPV) and the containment were simulated and analyzed, including the transient response, cooling capacity and thermal-hydraulic characteristics and so on. The station black-out transient in the SMR can be simulated accurately, and the main failure model in the accident process can be concluded. Then three other cases of the SBO accident with different passive safety systems (core makeup tank (CMT), accumulator (ACC), passive residual heat removal system heat exchanger (PRHR HX), automatic depressurization system (ADS)) of the PXS were calculated respectively, and the results for different passive safety systems were compared. The passive core cooling system can not only provide water to the primary coolant system, but also take away the reactor decay residual heat. So in a station black-out transient, we can get more time for restoring AC power, and effectively prevent the accidents such as Fukushima.  相似文献   

19.
非能动余热排出系统数学模型研究与运行特性分析   总被引:2,自引:0,他引:2  
利用某型核动力装置非能动余热排出系统1:10原理性试验的8个稳态工况、6个启动工况的试验数据,验证RELAP5/MOD3.2程序对本类型非能动余热排出系统的适用性。结果表明:垂直管内蒸汽凝结换热系数对两相流自然循环的流动与传热影响大;RELAP5/MOD3.2程序过低估算了垂直管内蒸汽流速对蒸汽凝结换热系数的影响,计算结果与试验结果偏差大。对RELAP5/MOD3.2程序垂直管内的蒸汽凝结换热模型进行修正,修正后的计算结果与试验值基本吻合;采用RELAP5程序对垂直管内两相流自然循环传热进行计算,须选择热前沿跟踪模型。对非能动余热排出系统的稳态与瞬态运行特性进行分析,理论计算与试验结果均表明:稳态工况下,系统可以实现稳定的两相流自然循环,系统排热能力受蒸汽发生器水位的影响大,冷却水入口温度与系统压力的影响相对较小;系统的启动特性良好,可快速地建立环路的自然循环,带走反应堆的衰变热。  相似文献   

20.
A thermal-hydraulic integral effect test facility, SMART-ITL, was constructed to examine the system performance of SMART, a 330 MWt integral type reactor, and to provide data for validation of related thermal-hydraulic models in the system analysis codes. SMART is equipped with various passive systems such as a passive residual heat removal system (PRHRS), a passive safety injection system (PSIS), and an automatic depressurization system (ADS). The PSIS of SMART is made up of four core makeup tanks (CMTs), four safety injection tanks (SITs), and related piping. Over 10 tests have been performed to investigate the behavior of a single train of a PSIS (a CMT and a SIT) in connection with PRHRSs and an ADS. Using a system analysis code, MARS-KS, we validated the experimental results for a representative test. All geometrical and thermal-hydraulic conditions of SMART-ITL were reflected in the code input construction. Through the validation process, several models, including a break flow model, heat transfer models, and pressure drop models, were examined. Overall, the major system parameters were well reproduced.  相似文献   