1.
为研究钢板类型、墙体连接件、轴压比以及剪跨比对双波纹钢板混凝土组合剪力墙抗震性能的影响,设计并完成了15个双钢板混凝土组合剪力墙(13个波纹钢板试件、2个平钢板试件)的拟静力试验,观察了试件的破坏过程,获取了应变分布数据,分析了各变化参数对双钢板混凝土组合剪力墙抗震性能指标的影响规律。试验结果表明:与横向波纹双钢板混凝土组合剪力墙相比,竖向波纹双钢板混凝土组合剪力墙的承载力更高,承载力及刚度退化更为缓慢,延性更好;在承载力接近的情况下,双波纹钢板混凝土组合剪力墙的延性与耗能均显著优于平钢板的;设置连接件导致双钢板混凝土组合剪力墙的初始刚度降低,使其破坏阶段的承载力退化减缓,且小剪跨比时设置连接件可有效提升双钢板混凝土组合剪力墙的承载力和延性,防止其发生面外破坏;试验中增大轴压比可显著提升双钢板混凝土组合剪力墙的承载力、初始刚度和耗能能力,但双钢板混凝土组合剪力墙的承载力及刚度退化速率增快,延性变差;增大剪跨比将显著降低双钢板混凝土组合剪力墙的承载力和初始刚度,对延性和耗能能力影响并不显著;采用全截面塑性理论进行双波纹钢板混凝土组合剪力墙正截面承载力计算,试验结果与计算值吻合良好。  相似文献   

2.
低剪跨比双钢板-混凝土组合剪力墙抗震性能试验研究   总被引:5,自引:0,他引:5  
为研究低剪跨比双钢板-混凝土组合剪力墙的抗震性能,完成了2片低剪跨比双钢板-混凝土组合剪力墙和1片低剪跨比钢筋混凝土剪力墙试验,研究了高轴压比剪力墙在低周往复荷载作用下的变形能力、破坏模式,得到了试件滞回曲线、骨架曲线、承载力、位移延性系数、刚度退化、承载力退化和耗能能力等,分析了不同形式连接件对抗震性能的影响。试验结果表明:与钢筋混凝土剪力墙相比,低剪跨比双钢板-混凝土组合剪力墙受剪承载力显著提高,具有良好的延性和耗能能力,抗震性能良好。  相似文献   

3.
为研究轴压比与剪跨比对带约束拉杆双层钢板-混凝土组合剪力墙抗震性能的影响,完成了5个缩尺模型试件的拟静力试验。研究结果表明:试件破坏时底部墙体钢板均受压屈曲,其中低剪跨比(剪跨比为1.0)试件出现典型的剪压破坏现象,而中高剪跨比(剪跨比为1.5~2.0)试件出现典型的压弯破坏现象;高轴压比、低剪跨比的带约束拉杆双层钢板-混凝土组合剪力墙仍具有良好的承载力、变形及耗能能力;增大轴压比可提高试件的承载力,但其变形和滞回性能有所降低;减小剪跨比,试件的承载力和刚度有较大幅度提高,耗能能力有所下降,而延性和承载力退化变化不明显。  相似文献   

4.
提出一种带约束拉杆双层钢板内填混凝土组合剪力墙,通过对6个剪跨比为2.0、轴压比为0.6的此类剪力墙试件的低周往复加载试验,研究试件的破坏形态、滞回曲线、骨架曲线、承载力退化、刚度退化、位移延性系数和耗能等抗震性能。结果表明:带约束拉杆双层钢板内填混凝土组合剪力墙抗震性能良好,6个试件的屈服位移角平均值为1/147,极限位移角平均值为1/48,位移延性系数平均值为3.57;减小约束拉杆间距和采用梅花式布置约束拉杆的方式,能更好地对钢板和混凝土提供约束,延缓钢板局部屈曲,增大混凝土的极限变形能力,提高剪力墙承载力、延性和耗能能力,减缓承载力退化和刚度退化,改善剪力墙抗震性能。  相似文献   

5.
为了提高钢板混凝土组合剪力墙的抗震性能和可恢复性能,提出一种端部配置无黏结钢筋的钢板混凝土组合剪力墙,通过无黏结高强钢筋为墙体提供恢复力。进行了4个剪跨比2.28的钢板混凝土组合剪力墙低周反复荷载试验,分析了端部配置无黏结高强钢筋对试件的破坏形态、滞回特性、承载力、变形能力、刚度退化、耗能能力和可恢复性能的影响。试验结果表明:端部配置无黏结钢筋的钢板混凝土组合剪力墙最终发生压弯破坏,破坏截面应变基本符合平截面假定;端部配置无黏结高强钢筋提高了钢板混凝土组合剪力墙的承载力、变形能力、初始刚度和耗能能力;在内置钢板混凝土组合剪力墙端部配置无黏结高强钢筋可减轻受压区混凝土的破坏程度,减小墙体残余变形和裂缝宽度,具有较好的可恢复性能。给出了端部配置无黏结钢筋钢板混凝土组合剪力墙的水平承载力计算方法,计算结果与试验结果符合较好,误差在15%以内。  相似文献   

6.
采用ABAQUS软件,建立4个带钢板耗能键的钢管混凝土排柱组合剪力墙模型,在验证建模方法可靠的基础上,对不同试件进行低周反复荷载下滞回特性、耗能能力、骨架曲线、延性、强度退化及刚度退化的对比研究,得出试件骨架曲线、滞回曲线,计算出承载力和位移延性系数,并分析剪跨比、钢管套箍率、材料强度等级三个不同参数对组合剪力墙的影响。结果表明,该组合剪力墙的承载力高、耗能能力强、后期刚度稳定、抗震性能良好;组合结构的承载力、耗能能力均随钢板数量增加而提高,但延性下降,外包混凝土能够大大提高结构的承载力和耗能能力;随剪跨比的增大,组合剪力墙承载力下降,但变形能力增强;随钢管套箍率增大,组合剪力墙的承载力和延性系数比增大,钢管套箍率宜取1.01;钢管内部的混凝土对整体结构强度影响的效果不明显。  相似文献   

7.
采用ABAQUS软件,建立4个带钢板耗能键的钢管混凝土排柱组合剪力墙模型,在验证建模方法可靠的基础上,对不同试件进行低周反复荷载下滞回特性、耗能能力、骨架曲线、延性、强度退化及刚度退化的对比研究,得出试件骨架曲线、滞回曲线,计算出承载力和位移延性系数,并分析剪跨比、钢管套箍率、材料强度等级三个不同参数对组合剪力墙的影响。结果表明,该组合剪力墙的承载力高、耗能能力强、后期刚度稳定、抗震性能良好;组合结构的承载力、耗能能力均随钢板数量增加而提高,但延性下降,外包混凝土能够大大提高结构的承载力和耗能能力;随剪跨比的增大,组合剪力墙承载力下降,但变形能力增强;随钢管套箍率增大,组合剪力墙的承载力和延性系数比增大,钢管套箍率宜取1.01;钢管内部的混凝土对整体结构强度影响的效果不明显。  相似文献   

8.
提出一种设置C形连接件的新型双钢板-混凝土组合剪力墙。为研究此类组合墙的抗震性能,设计并完成了6片高剪跨比双钢板-混凝土组合剪力墙的低周反复水平荷载试验。对试件的破坏现象、承载能力、轴压比、滞回曲线、骨架曲线、变形能力、位移延性系数及耗能能力进行了分析研究。试验结果表明:C形连接件可以有效地限制两侧钢面板的屈曲;在屈服阶段,试件的屈曲主要出现在端柱底部和墙身底部。试件的最终破坏形态为端柱脚部断裂;结构具有较高的承载力。组合墙正截面压弯承载力理论计算值与试验值吻合良好;试件的滞回曲线饱满,具有良好的延性及耗能能力,试件破坏时的平均极限位移角为1/52,位移延性系数为2. 49~3. 55。  相似文献   

9.
为了提高钢板混凝土组合剪力墙的抗震性能和可恢复性能,提出一种端部配置无黏结钢筋的钢板混凝土组合剪力墙,通过无黏结高强钢筋为墙体提供恢复力。进行了4个剪跨比2.28的钢板混凝土组合剪力墙低周反复荷载试验,分析了端部配置无黏结高强钢筋对试件的破坏形态、滞回特性、承载力、变形能力、刚度退化、耗能能力和可恢复性能的影响。试验结果表明:端部配置无黏结钢筋的钢板混凝土组合剪力墙最终发生压弯破坏,破坏截面应变基本符合平截面假定;端部配置无黏结高强钢筋提高了钢板混凝土组合剪力墙的承载力、变形能力、初始刚度和耗能能力;在内置钢板混凝土组合剪力墙端部配置无黏结高强钢筋可减轻受压区混凝土的破坏程度,减小墙体残余变形和裂缝宽度,具有较好的可恢复性能。给出了端部配置无黏结钢筋钢板混凝土组合剪力墙的水平承载力计算方法,计算结果与试验结果符合较好,误差在15%以内。  相似文献   

10.
为研究核电工程中屏蔽厂房所采用的结构形式——双钢板混凝土组合墙体的抗震性能,对不同距厚比、不同抗剪连接件形式的双钢板混凝土组合墙体进行了拟静力抗震性能试验研究。试验模型按照1/5缩尺,设计了4个双钢板混凝土组合墙体试件。通过试验,分析了组合墙体的承载力、延性、刚度及滞回特性、耗能能力和破坏特征。结果表明:随着距厚比的减小,试件极限承载力有所提高但不显著,距厚比对栓钉的断裂点是否达到构件的极限承载力有明显影响,加劲肋连接件对提高构件的极限承载力、整体刚度、延性和耗能能力效果显著;4个试件的内部混凝土开裂荷载基本相同,抗震性能良好。  相似文献   

11.
为研究波形钢板-混凝土组合剪力墙的抗震性能,完成了竖向波形钢板-混凝土组合剪力墙、水平波形钢板-混凝土组合剪力墙以及平钢板-混凝土组合剪力墙拟静力试验,研究了波形钢板-混凝土组合剪力墙在低周往复荷载作用下的变形能力和破坏模式,分析了荷载-位移滞回曲线、骨架曲线、各阶段特征荷载和位移值等,以及结构的破坏特征、变形和耗能能力、刚度和承载力退化。试验结果表明:波形钢板-混凝土组合剪力墙具有较大的抗侧刚度、较好的延性和耗能能力;与平钢板-混凝土组合剪力墙相比,波形钢板-混凝土组合剪力墙有较好的界面黏结性能,而平钢板-混凝土剪力墙由钢板变形引起的混凝土剥落严重;波形钢板-混凝土组合剪力墙的初始刚度较平钢板-混凝土组合剪力墙的高,竖向波形钢板-混凝土组合剪力墙的承载力和极限位移较水平波形钢板-混凝土组合剪力墙的高,波形钢板-混凝土组合剪力墙的承载力退化和刚度退化比平钢板-混凝土组合剪力墙的慢,表现出较好的受力性能。采用ABAQUS有限元软件可以较好地模拟试验,有限元分析结果表明,波形钢板的应力分布比较均匀,组合作用效应明显,适合在抗震结构中采用。  相似文献   

12.
In this paper, composite shear walls with different encased steel plates (flat, horizontal corrugated, and vertical corrugated) were tested and simulated by Abaqus to investigate the seismic behavior of corrugated steel plate concrete composite shear walls (SPCSWs). The failure characteristics, deformation and energy dissipation capacity, and stiffness and bearing capacity of the structures under low‐frequency cyclic load were analyzed, and indexes of the seismic performance were obtained. The formulas of the shear‐bearing capacity of steel plate concrete composite shear walls are suggested, and the shear‐sharing ratio of each member is obtained. According to the obtained results, corrugated steel plates can bond with concrete well, and the bearing capacity of the vertical corrugated SPCSW are higher than that of the horizontal corrugated SPCSW. Compared with flat SPCSW, corrugated SPCSW has higher initial stiffness and lateral stiffness, better ductility and energy dissipation ability, and the degradation of bearing capacity and stiffness is slower. The shear‐sharing ratio of a steel plate is larger than that of reinforced concrete in the flat SPCSW and the vertical corrugated SPCSW, the shear force shared by steel plate and reinforced concrete in horizontal corrugated SPCSW is basically the same.  相似文献   

13.
不同钢—混凝土组合剪力墙抗震性能对比分析   总被引:1,自引:1,他引:0  
钢—混凝土组合剪力墙中钢板的布置形式是影响其抗震性能的一个主要因素。通过对两组内置钢板混凝土组合剪力墙和内藏钢桁架混凝土组合剪力墙试验的模拟,确定计算模型的建立方法,并选取两片相同含钢率的内置钢板混凝土组合剪力墙和内藏钢桁架混凝土组合剪力墙进行在侧向低周反复荷载作用下的计算分析,对比了两片剪力墙的承载力、刚度及其退化过程、延性、耗能特性及滞回特性。研究结果表明:在相同含钢率的条件下,内藏钢桁架混凝土组合剪力墙与内置钢板混凝土组合剪力墙相比,承载力、延性、耗能能力均有较明显提高。  相似文献   

14.
通过对2组内置钢板混凝土组合剪力墙和内置钢桁架混凝土组合剪力墙拟静力试验的模拟,确定计算模型的建立方法,并选取2片相同含钢率的内置钢板混凝土组合剪力墙和内置钢桁架混凝土组合剪力墙模型进行侧向低周反复荷载作用下的计算分析,对比了2片剪力墙模型的承载力、刚度及其退化过程、延性、耗能及滞回特性,并选取实际工程为算例,对采用两种组合剪力墙的整体结构从抗侧刚度、破坏模式、层间位移角、位移时程及塑性发展等方面进行了抗震性能的对比。研究结果表明:对于构件层次,随着墙体高宽比的增大,内置钢板混凝土组合剪力墙的承载力、耗能能力及延性逐渐优于内置钢桁架混凝土组合剪力墙;对于结构层次,当墙体高宽比较大时,采用内置钢板混凝土组合剪力墙结构的抗震性能要优于采用内置钢桁架混凝土组合剪力墙的结构。  相似文献   

15.
提出一种新型的配置L形拉结件的双钢板-混凝土组合剪力墙。通过两组共6个双钢板-混凝土组合剪力墙试件的拟静力试验,对此新型组合剪力墙的抗震性能进行了研究。试件改变参数主要为轴压比和连接件间距,在试验的基础上对试件的破坏形态、承载能力、滞回曲线、骨架曲线、刚度退化曲线等进行分析。试验研究表明:L形拉结件的配置既能增强外包钢板对核心内混凝土的约束作用又能抑制外包钢板的屈曲,充分保证了外包钢板和混凝土之间的协同工作,此新型组合剪力墙具有较高的承载力,较好的延性及耗能能力。在达到峰值荷载之前,墙体钢板未发生明显的局部屈曲变形,最终组合剪力墙均因端柱屈曲拉裂而开始破坏;破坏时极限位移角的平均值为1/58;随着距厚比减小,试件的水平承载力和延性系数均显著提高。  相似文献   

16.
带约束拉杆钢板-混凝土组合剪力墙抗震性能试验研究   总被引:1,自引:0,他引:1  
为研究带约束拉杆钢板-混凝土组合剪力墙的抗震性能,制作10个钢板之间采用八螺母螺栓连接的钢板-混凝土组合剪力墙试件并对其进行拟静力试验,研究试件的破坏模式、变形能力及耗能能力,得到试件的滞回曲线、承载力、骨架曲线、刚度退化曲线、位移延性系数以及累计耗能曲线等,分析高宽比、约束拉杆间距、钢板厚度、核心混凝土厚度、轴压比及边缘增设型钢对试件抗震性能的影响。结果表明:钢板之间采用八螺母螺栓连接可行,带约束拉杆钢板-混凝土组合剪力墙抗震性能较好,随高宽比降低、约束拉杆间距减小、钢板厚度增大、核心混凝土增厚及边缘增设型钢,其抗震性能增强;端部增设型钢可显著提高试件承载力;减小约束拉杆间距可显著提高试件的延性。  相似文献   

17.
为了研究采用钢板焊接连接的带水平接缝预制装配式钢筋混凝土剪力墙的抗震性能,设计了4个装配式钢筋混凝土剪力墙足尺试件并进行低周往复水平荷载试验,研究参数包括连接钢板厚度、侧向钢板设置和轴压比。结果表明:各试件均为压弯破坏,水平承载力在186~288kN之间,极限位移在25.74~29.37mm之间,滞回曲线为饱满的弓形,延性和耗能能力较好,刚度退化较慢;在连接钢板满足强度要求前提下,增大连接钢板厚度、增加侧向钢板对剪力墙的延性、刚度、承载能力和耗能能力影响较小;提高轴压比可以明显提高装配式剪力墙的刚度和承载能力,但会降低其耗能能力。采用ABAQUS有限元软件对装配式剪力墙抗震性能进行分析,所建立的有限元模型可以较好地模拟装配式剪力墙的受力性能。通过对比采用规范公式计算的承载力与试验承载力,表明可以采用JGJ 3—2010《高层建筑混凝土结构技术规程》中的公式计算文中装配式剪力墙的承载力,并给出了连接钢板的计算方法。  相似文献   

18.
Shear walls and core tubes in shear walls constitute the core anti‐earthquake vertical systems of high‐rise buildings. This paper proposes a new type of composite shear wall with concrete‐filled steel tubular frames and corrugated steel plates. The seismic behavior of the new shear wall is studied using a cyclic loading test and damage analysis. The failure mode, load‐carrying capacity, ductility, stiffness degradation, hysteresis behavior, and energy dissipating capacity exhibited in the test are studied. The test results show that when the proposed wall is broken, the tension side of concrete‐filled steel tubes is torn. The concrete at the bottom of the wall is detached and peels off along the through cracks. The energy dissipation capacity of concrete walls is more fully utilized. The proposed wall exhibits excellent deformability, energy dissipation capacity, and the stiffness degradation was slower than that of other walls. The use of corrugated steel plate significantly improved the seismic performance while simultaneously increasing the ductility and reducing the damage. In addition, this paper modified the energy dissipation factor in the Park & Ang model based on the situation of the specimen and experiment. It can be used to evaluate the damage degree of this new type of shear wall.  相似文献   