首页 | 官方网站   微博 | 高级检索  
相似文献
 共查询到10条相似文献,搜索用时 109 毫秒
1.
This paper presents a Stochastic Multi-objective Optimal Operation Management (SMOOM) framework of distribution networks in presence of PEM-Fuel Cell Power Plants (FCPPs) and boilers. Operational costs, thermal recovery, power trade with grid and hydrogen management strategies are considered in this model. Furthermore, four objective functions has been considered as criteria for SMOOM, i.e. electrical energy losses, voltages deviations from their nominal values, total emissions emitted by CHP systems and grids, and total operational costs of CHP systems, as well as electrical energy cost of grids. A 2m + 1 Point Estimated Method is used to cope with the uncertain variables i.e. electrical and thermal loads, gas price of FCPPs consumption, fuel cost of residential loads, purchasing and selling tariff of electricity, hydrogen price, operation temperature of fuel cell stack, and the pressures of hydrogen and oxygen of anode and cathode, respectively. A new multi-objective Modified Firefly Algorithm (MFA) is implemented for minimizing the objective functions while the operational constraints are satisfied. Finally, a 69-bus distribution network is utilized to examine the performance of the proposed strategy regarding the rest.  相似文献   

2.
With the increasing proportion of renewable energy (mainly wind power and photovoltaic) connected to the grid, the fluctuation of renewable energy power brings great challenges to the safe and reliable operation of power grid. As a clean, low-carbon secondary energy, hydrogen energy is applied in renewable energy (mainly wind power and photovoltaic) grid-connected power smoothing, which opens up a new way of coupling hydrogen storage energy with renewable energy. This paper focuses on the optimization of capacity of electrolyzers and fuel cells and the analysis of system economy in the process of power output smoothing of wind/photovoltaic coupled hydrogen energy grid-connected system. Based on the complementary characteristics of particle swarm optimization (PSO) and chemical reaction optimization algorithm (CROA), a particle swarm optimization-chemical reaction optimization algorithm (PSO-CROA) are proposed. Aiming at maximizing system profit, the capacity of electrolyzers and fuel cells are constrained by wind power fluctuation, and considering environmental benefits, government subsidies and time value of funds, the objective function and its constraints are established. According to the simulation analysis, by comparing the calculated results with PSO and CROA, it shows that PSO-CROA effectively evaluates the economy of the system, and optimizes the optimal capacity of the electrolyzers and fuel cells. The conclusion of this paper is of great significance for the application of hydrogen energy storage in the evaluation of power smoothness and economy of renewable energy grid connection and the calculation of economic allocation of hydrogen energy storage capacity.  相似文献   

3.
Cooling, Heating, and Power (CHP) systems have the potential to make better use of fuels than other technologies because of their ability to increase the overall thermal energy efficiency. Feasibility of CHP systems is generally driven by economic savings. In addition, economic evaluation of CHP systems is based on site energy use and cost, which could lead to misleading conclusions about energy savings. Since energy savings from CHP systems only occurs in primary energy, the objective of this investigation is to demonstrate that feasibility of CHP systems should be performed based on primary energy savings followed by economic considerations. This paper also evaluates the effect of the power generation unit (PGU) efficiency over the primary energy reduction when a CHP system is utilized. The advantages of operating CHP systems under a primary energy operational strategy, such as the proposed Building Primary Energy Ratio (BPER) strategy, are also discussed. Results show that for some cases economic savings are attained without the corresponding primary energy savings. However, the use of the BPER operational strategy guarantees better energy performance regardless of economic savings. Regarding to the PGU efficiency, an increase of the efficiency reduces the primary energy use more than proportionally. For example, increasing the PGU efficiency from 0.25 to 0.35 (increase of 40%) can reduce the primary energy use from 5.4% to 16% (increase of 200%).  相似文献   

4.
Power generation with direct methanol fuel cell (DMFC) systems requires only simple equipment, and has the important advantage of using a liquid fuel with higher energy density and easier handling characteristics than hydrogen. However, the power output of DMFC is lower than hydrogen fuel cells. To improve the power output of DMFC it is very important to reduce diffusion polarization at higher current density conditions. This research used a corrosion-resisting type porous stainless steel developed based on the technology for metal–hydride battery electrodes in the separator flow fields for reactants and products in a single cell DMFC and analyzed its influence on performance characteristics.  相似文献   

5.
Power systems based on fuel cells have been considered for residential and commercial applications in energy Distributed Generation (DG) markets. In this work we present an experimental analysis of a power generation system formed by a 5 kW proton exchange membrane fuel cell (PEMFC) unit and a natural gas reformer (fuel processor) for hydrogen production. The performance analysis developed simultaneously the energy and economic viewpoints and enabled the determination of the best technical and economic conditions of this energy generation power plant, and the best operating strategies, enabling the optimization of the overall performance of the stationary cogeneration fuel cell unit. It was determined the electrical performance of the cogeneration system in function of the design and operational power plant parameters. Additionally, it was verified the influence of the activation conditions of the fuel cell electrocatalytic system on the system performance. It also appeared that the use of hydrogen produced from the natural gas catalytic reforming provided the system operation in excellent electrothermal stability conditions resulting in increase of the energy conversion efficiency and of the economicity of the cogeneration power plant.  相似文献   

6.
There is rising interest globally in the use of hydrogen for the provision of electricity or heat to industry, transport, and other applications in low-carbon energy systems. While there is attention to build out dedicated hydrogen infrastructure in the long-term, blending hydrogen into the existing natural gas pipeline network is also thought to be a promising strategy for incorporating hydrogen in the near-term. However, hydrogen injection into the existing gas grid poses additional challenges and considerations related to the ability of current gas infrastructure to operate with blended hydrogen levels. This review paper focuses on analyzing the current understanding of how much hydrogen can be integrated into the gas grid from an operational perspective and identifies areas where more research is needed. The review discusses the technical limits in hydrogen blending for both transmission and distribution networks; facilities in both systems are analyzed with respect to critical operational parameters, such as decrease in energy density, increased flow speed and pressure losses. Safety related challenges such as, embrittlement, leakage and combustion are also discussed. The review also summarizes current regulatory limits to hydrogen blending in different countries, including ongoing or proposed pilot hydrogen blending projects.  相似文献   

7.
王永红  李晓平  宫敬  张燕 《节能技术》2010,28(5):465-468
成品油在管道输送过程中,沿线泵机组在管道运行中要消耗电力。结合成品油管道能源管理的国内、外现状,对成品油管道能源管理过程中存在的问题进行了分析总结,并根据能源管理工作的总体目标和成品油管道的运营特点,设计了成品油管道的能源管理系统,并阐述了其主要研究内容。  相似文献   

8.
This paper evaluates hydrogen and power co-generation based on direct coal chemical looping systems with total decarbonization of the fossil fuel. As an illustrative example, an iron-based chemical looping system was assessed in various plant configurations. The designs generate 300–450 MW net electricity with flexible hydrogen output in the range of 0–200 MWth (LHV). The capacity of evaluated plant concepts to have a flexible hydrogen output is an important aspect for integration in modern energy conversion systems. The carbon capture rate of evaluated concepts is almost total (>99%). The paper presents in details evaluated plant configurations, operational aspects as well as mass and energy integration issues. For comparison reason, a syngas-based chemical looping concept and Selexol®-based pre-combustion capture configuration were also presented. Direct coal chemical looping configuration has significant advantages compared with syngas-based looping systems as well as solvent-based carbon capture configurations, the more important being higher energy efficiency, lower (or even zero) oxygen consumption and lower plant complexity. The results showed a clear increase of overall energy efficiency in comparison to the benchmark cases.  相似文献   

9.
A rooftop photovoltaic power station, or rooftop PV system, is a photovoltaic system that has its electricity-generating solar panels mounted on the rooftop of a residential or commercial building or structure. The various components of such a system include photovoltaic modules, mounting systems, cables, solar inverters, and other electrical accessories. Rooftop mounted systems are small compared to ground-mounted photovoltaic power stations with capacities in the MW (megawatt) range. With the significant improvement of Rooftop Solar Photovoltaic Energy System (RSPES) among various Renewable Energy Systems, the major issues, effects, and several operational characteristics of the rooftop solar PVs in the Distribution System (DS) with Low Power Utility Network are actively being studied and investigated by global researchers and operation engineers. The most important objective of various researches about RSPES is to design a Power System with Optimal Maximum Power Transfer Capacity (MPTC). These review papers analyze the performance of Secondary Distribution System integrated to grid with Smart Inverter with or without the presence of Distribution Generation (DG) units. The effects caused by the penetration of Rooftop Solar Photovoltaic (PV) units in the Distribution Equipment (DE) are detailed in this paper with various research techniques. With the consideration of different objective constraints, Optimization techniques are utilized for solving minimization problems of objectives such as Size, Area, Operational Characteristics, Energy Loss, Cost of Installation, Generation Cost, Peak Load, Reverse Power Flow, and maximization problems of objectives such as PV power generation, Energy Saving Capability, Electricity Energy Mix, etc.. The various optimization techniques and frameworks for improving the performance of Power System and their corresponding results are demonstrated in this paper. This paper reviews totally 42 related researches done on the different phases of Optimization based Rooftop Solar PV system in the period between 2015 and 2017. This review summarizes the evaluation of the i) Solar rooftop energy with effects of increase in penetration; ii) The performance of efficient secondary distribution system with grid integrated smart inverter; iii) Algorithms based on optimization for solving the objectives in rooftop solar PV system are investigated.  相似文献   

10.
The concept of solar-hydrogen systems for spacecraft, orbital stations, lunar and Martian bases is currently receiving a new impetus. The supply of solar energy to energy receivers aboard space vehicles is limited. The number of everyday tasks and energy-intensive experiments on board space objects is growing with the development of astronautics. To perform energy-intensive work and experiments, energy consumption exceeds the incoming solar fluxes. The modern solar-hydrogen system ensures the reception, conversion and accumulation of excess incoming energy in the form of chemical energy - hydrogen. Cryogenics makes it possible to miniaturize the solar-hydrogen system. The safety of the cryogenic solar-hydrogen energy system is ensured by hydrogen concentration and leakage sensors.The article proposes a comprehensive solution for miniaturization of Power Conversion Unit (PCU) of Energy Power System (EPS) of spacecrafts (SC), which consists in a joint solution of four key problems of miniaturization of power devices: energy, structural, design and technological, system. Miniaturization of the solar-hydrogen energy system (SHES) is achieved by installing onboard hydrogen and oxygen microcryogenic refrigerators, as well as hydrogen and oxygen cryogenic tanks, water tank, electrolyzer and hydrogen fuel cells (FC). The accumulation of chemical hydrogen energy on board the orbiting spacecraft ensures reliable operation when entering the shadow. Storage of hydrogen in cryogenic form significantly reduces the volume required. A cryocooler based on the Stirling cycle provides the process of liquefying hydrogen after the electrolysis of distilled water. In addition, cryogenic temperatures of 20.2 K can be used to thermostat precision instruments placed on board the spacecraft, For example, to ensure the operation of the SQUID. A 3D - model of a voltage stabilization module (VSM), on the basis of which EEC can be produced with different output power and redundancy depth. We give an example of a complete structural scheme of the EEC, which allows implementing all the fulfillment of all the tasks, assigned to the EEC of the PCU SC.  相似文献   