 共查询到20条相似文献,搜索用时 31 毫秒
1.
A domestic-scale prototype experimental solar cooling system has been developed based on a LiBr/H2O absorption system and tested during the 2007 summer and autumn months in Cardiff University, UK. The system consisted of a 12 m2 vacuum tube solar collector, a 4.5 kW LiBr/H2O absorption chiller, a 1000 l cold storage tank and a 6 kW fan coil. The system performance, as well as the performances of the individual components in the system, were evaluated based on the physical measurements of the daily solar radiation, ambient temperature, inlet and outlet fluid temperatures, mass flow rates and electrical consumption by component. The average coefficient of thermal performance (COP) of the system was 0.58, based on the thermal cooling power output per unit of available thermal solar energy from the 12 m2 Thermomax DF100 vacuum tube collector on a hot sunny day with average peak insolation of 800 W/m2 (between 11 and 13.30 h) and ambient temperature of 24 °C. The system produced an electrical COP of 3.6. Experimental results prove the feasibility of the new concept of cold store at this scale, with chilled water temperatures as low as 7.4 °C, demonstrating its potential use in cooling domestic scale buildings.  相似文献   

2.
An experimental solar energy facility was designed to meet as much of the heating demand in a typical Spanish dwelling as possible. With a view to using the facility during the summer and preventing overheating-induced deterioration of the solar collectors in that season of the year, an absorption chiller was fitted to the system to produce solar-powered air conditioning. The facility operated in solar space heating mode in the winter of 2008–2009 and in cooling mode during the summer of 2008. The design was based on a new type of flat plate vacuum solar collectors that delivered higher efficiency than conventional panels. This type of collectors can reach temperatures of up to 110 °C in the summer and up to 70 °C on the coldest winter days. The solar facility comprised a 48-m2 (with a net area of 42 m2) solar collector field, a 25-kW plate heat exchanger, a 1500-l storage tank, a 4.5-kW (Rotartica) air-cooled absorption chiller and several fan coils. The facility was tested by using it to heat and cool an 80-m2 laboratory located in Madrid. As the average area of Spanish homes is 80 m2, the findings were generally applicable to national housing. The solar facility was observed to be able to meet 65.3% of the space heating demand. For air conditioning, the system covered 46% of the demand, but with high indoor temperatures. In other words, the collector field was found to be able to air condition only half of the home (40 m2). Lastly, the savings in CO2 emissions afforded by the use of this facility compared to conventional air conditioning were calculated, along with its amortisation period. These results have been extrapolated calculating the potential energy savings and emissions reduction for all the Spanish households.  相似文献   

3.
A solar-driven 10-ton LiBr/H2O single-effect absorption cooling system has been designed and installed at the School of Renewable Energy Technology (SERT), Phitsanulok, Thailand. Construction took place in 2005, after which this system became fully operational and has been supplying cooling for our main testing building's air-conditioning. Data on the system's operation were collected during 2006 and analyzed to find the extent to which solar energy replaced conventional energy sources. Here, we present these data and show that the 72 m2 evacuated tube solar collector delivered a yearly average solar fraction of 81%, while the remaining 19% of thermal energy required by the chiller was supplied by a LPG-fired backup heating unit. We also show that the economics of this cooling system are dominated by the initial cost of the solar collector array and the absorption chiller, which are significantly higher than that of a similar-size conventional VCC system.  相似文献   

4.
The long-term system simulation and economic analysis of solar-assisted cooling/heating system (SACH-2) was carried out in order to find an economical design. The solar heat driven ejector cooling system (ECS) is used to provide part of the cooling load to reduce the energy consumption of the air conditioner installed as the base-load cooler. A standard SACH-2 system for cooling load 3.5 kW (1 RT) and daily cooling time 10 h is used for case study. The cooling performance is assumed only in summer seasons from May to October. In winter season from November to April, only heat is supplied. Two installation locations (Taipei and Tainan) were examined.It was found from the cooling performance simulation that in order to save 50% energy of the air conditioner, the required solar collector area is 40 m2 in Taipei and 31 m2 in Tainan, for COPj = 0.2. If the solar collector area is designed as 20 m2, the solar ejector cooling system will supply about 17–26% cooling load in Taipei in summer season and about 21–27% cooling load in Tainan. Simulation for long-term performance including cooling in summer (May–October) and hot water supply in winter (November–April) was carried out to determine the monthly-average energy savings. The corresponding daily hot water supply (with 40 °C temperature rise of water) for 20 m2 solar collector area is 616–858 L/day in Tainan and 304–533 L/day in Taipei.The economic analysis shows that the payback time of SACH-2 decreases with increasing cooling capacity. The payback time is 4.8 years in Tainan and 6.2 years in Taipei when the cooling capacity >10 RT. If the ECS is treated as an additional device used as a protective equipment to avoid overheating of solar collectors and to convert the excess solar heat in summer into cooling to reduce the energy consumption of air conditioner, the payback time is less than 3 years for cooling capacity larger than 3 RT.  相似文献   

5.
In this study, performance assessment of an integrated cooling plant having both free cooling system and solar powered single-effect lithium bromide–water absorption chiller in operation since August 2002 in Oberhausen, Germany, was performed. A floor space of 270 m2 is air-conditioned by the plant. The plant includes 35.17 kW cooling (10-RT) absorption chiller, vacuum tube collectors’ aperture area of 108 m2, hot water storage capacity of 6.8 m3, cold water storage capacity of 1.5 m3 and a 134 kW cooling tower. The results show that free cooling in some cooling months can be up to 70% while it is about 25% during the 5 years period of the plant operation. For sunny clear sky days with equal incident solar radiation, the daily solar heat fraction ranged from 0.33 to 0.41, collectors’ field efficiency ranged from 0.352 to 0.492 and chiller COP varies from 0.37 to 0.81, respectively. The monthly average value of solar heat fraction varies from 31.1% up to 100% and the five years average value of about 60%. The monthly average collectors’ field efficiency value varies from 34.1% up 41.8% and the five-year average value amounts about 28.3%. Based on the obtained results, the specific collector area is 4.23 (m2/kWcold) and the solar energy system support of the institute heating system for the duration from August 2002 to November 2007 is 8124 kWh.  相似文献   

6.
The paper reports on a feasibility study of a solar-powered heating/cooling system for a swimming pool/space combination in a tropical environment. The system employs an absorption chiller and a cooling tower to meet the locker-room load. The heating is accomplished by employing hot water generated by heat exchange with the solar collector working fluid. Two thermal storage tanks are employed for the collector and domestic use. The absorption chiller utilizes hot water to regenerate the LiBr solution. The proposed system will enable the swimming season to be extended from 16 weeks to 52 weeks. The economic analysis is performed based on the life-cycle-cost method. The effects of discount rate, fuel prices, and the fuel inflation rate are discussed. The analysis shows, with the present level of fuel prices, that the solarassisted system is not economical enough over a life cycle of 10 years. The study presents different scenarios for which the solar-assisted system is, however, economical.  相似文献   

7.
Despite its attractiveness, solar cooling technology is still in an early stage of development. Most installations currently in operation show differences in the collector area per kilowatt of cooling capacity that cannot be explained only by project-specific circumstances. The purpose of this paper was twofold. First, to answer some questions that came up during the design process of the plant by using a TRNSYS system model and statistical tools. Second, to gain knowledge about the plant operation and validate the TRNSYS model through measured data. The system was equipped with a flat-plate collector field of 38.4 m2. A lithium bromide-water single-effect absorption chiller (17.6 kW) was selected in order to provide chilled water to fan-coils. Performance data were registered at the solar plant working with a 1000-l heat storage tank and a required temperature of 80 °C to drive the absorption machine. An average of 29% of the solar energy incident on the solar collectors’ surface was transferred to the hot water storage. The registered average COP of the absorption chiller was 0.691. The performance data were compared with the values predicted by the TRNSYS plant model and a high level of agreement was obtained.  相似文献   

8.
A solar-powered adsorption chiller with heat and mass recovery cycle was designed and constructed. It consists of a solar water heating unit, a silica gel-water adsorption chiller, a cooling tower and a fan coil unit. The adsorption chiller includes two identical adsorption units and a second stage evaporator with methanol working fluid. The effects of operation parameter on system performance were tested successfully. Test results indicated that the COP (coefficient of performance) and cooling power of the solar-powered adsorption chiller could be improved greatly by optimizing the key operation parameters, such as solar hot water temperature, heating/cooling time, mass recovery time, and chilled water temperature. Under the climatic conditions of daily solar radiation being about 16–21 MJ/m2, this solar-powered adsorption chiller can produce a cooling capacity about 66–90 W per m2 collector area, its daily solar cooling COP is about 0.1–0.13.  相似文献   

9.
The research goal was to develop a new solar water heater system (SWHS) that used a solar water pump instead of an electric pump. The pump was powered by the steam produced from a flat plate collector. Therefore, heat could be transferred downward from the collector to a hot water storage tank. The designed system consisted of four panels of flat plate solar collectors, an overhead tank installed at an upper level and a large water storage tank with a heat exchanger at a lower level. Discharge heads of 1, 1.5 and 2 m were tested. The pump could operate at the collector temperature of about 70–90 °C and vapor gage pressure of 7–14 kPa. It was found that water circulation within the SWHS ranged between 12 and 59 l/d depending on the incident solar intensity and system discharge head. The average daily pump efficiency was about 0.0014–0.0019%. Moreover, the SWHS could have a daily thermal efficiency of about 7–13%, whereas a conventional system had 30–60% efficiency. The present system was economically comparable to a conventional one.  相似文献   

10.
A new integrated combined cooling, heating and power system which includes a solid oxide fuel cell, Stirling engine, steam turbine, linear Fresnel solar field and double effect absorption chiller is introduced and investigated from energy, exergy and thermodynamic viewpoints. In this process, produced electrical power by the fuel cell and steam turbines is 6971.8 kW. Stirling engine uses fuel cell waste heat and produces 656 kW power. In addition, absorption chiller is driven by waste heat of the Stirling engine and generates 2118.8 kW of cooling load. Linear Fresnel solar field produces 961.7 kW of thermal power as a heat exchanger. The results indicate that, electrical, energy and exergy efficiencies and total exergy destruction of the proposed system are 49.7%, 67.5%, 55.6% and 12560 kW, respectively. Finally, sensitivity analysis to investigate effect of the different parameters such as flow rate of inputs, outlet pressure of the components and temperature changes of the solar system on the hybrid system performance is also done.  相似文献   

11.
A solar thermal cooling and heating system at Carnegie Mellon University was studied through its design, installation, modeling, and evaluation to deal with the question of how solar energy might most effectively be used in supplying energy for the operation of a building. This solar cooling and heating system incorporates 52 m2 of linear parabolic trough solar collectors; a 16 kW double effect, water-lithium bromide (LiBr) absorption chiller, and a heat recovery heat exchanger with their circulation pumps and control valves. It generates chilled and heated water, dependent on the season, for space cooling and heating. This system is the smallest high temperature solar cooling system in the world. Till now, only this system of the kind has been successfully operated for more than one year. Performance of the system has been tested and the measured data were used to verify system performance models developed in the TRaNsient SYstem Simulation program (TRNSYS). On the basis of the installed solar system, base case performance models were programmed; and then they were modified and extended to investigate measures for improving system performance. The measures included changes in the area and orientation of the solar collectors, the inclusion of thermal storage in the system, changes in the pipe diameter and length, and various system operational control strategies. It was found that this solar thermal system could potentially supply 39% of cooling and 20% of heating energy for this building space in Pittsburgh, PA, if it included a properly sized storage tank and short, low diameter connecting pipes. Guidelines for the design and operation of an efficient and effective solar cooling and heating system for a given building space have been provided.  相似文献   

12.
In this paper, the simulation of the performance of solar-assisted heating and cooling systems is analyzed. Three different plant layouts are considered: (i) the first one consists of evacuated solar collectors and a single-stage LiBr–H2O absorption chiller; here in order to integrate the system in case of insufficient solar radiation, an electric water-cooled chiller is activated; (ii) configuration of the secondly considered system is similar to the first one, but the absorption chiller and the solar collector area are sized for balancing about 30% of the building cooling load only; (iii) the layout of the thirdly considered system differs from the first one since the auxiliary electric chiller is replaced by a gas-fired heater. Such system configurations also include: circulation pumps, storage tanks, feedback controllers, mixers, diverters and on/off hysteresis controllers.  相似文献   

13.
A new photovoltaic-thermal (PVT) system has been developed to produce electricity and cooling energy. Experimental studies of uncovered PVT collectors were carried out in Stuttgart to validate a simulation model, which calculates the night radiative heat exchange with the sky. Larger PVT frameless modules with 2.8 m2 surface area were then implemented in a residential zero energy building and tested under climatic conditions of Madrid. Measured cooling power levels were between 60 and 65 W m−2, when the PVT collector was used to cool a warm storage tank and 40-45 W m−2, when the energy was directly used to cool a ceiling. The ratio of cooling energy to electrical energy required for pumping water through the PVT collector at night was excellent with values between 17 and 30. The simulated summer cooling energy production per square meter of PVT collector in the Madrid/Spain climatic conditions is 51 kWh m−2 a−1. In addition to the thermal cooling gain, 205 kWh m−2 a−1 of AC electricity is produced under Spanish conditions. A comparative analysis for the hot humid climate of Shanghai gave comparable results with 55 kWh m−2 a−1 total cooling energy production, mainly usable for heat rejection of a compression chiller and a lower electricity production of 142 kWh m−2 a−1.  相似文献   

14.
In this paper, a solar-powered compound system for heating and cooling was designed and constructed in a golf course in Taiwan. An integrated, two-bed, closed-type adsorption chiller was developed in the Industrial Technology Research Institute in Taiwan. Plate fin and tube heat exchangers were adopted as an adsorber and evaporator/condenser. Some test runs have been conducted in the laboratory. Under the test conditions of 80 °C hot water, 30 °C cooling water, and 14 °C chilled water inlet temperatures, a cooling power of 9 kW and a COP (coefficient of performance for cooling) of 0.37 can be achieved. It has provided a SCP (specific cooling power) of about 72 W/(kg adsorbent). Some field tests have been performed from July to October 2006 for providing air-conditioning and hot water. The efficiency of the collector field lies in 18.5–32.4%, with an average value of 27.3%. The daily average COP of the adsorption chiller lies in 33.8–49.7%, with an average COP of 40.3% and an average cooling power of 7.79 kW. A typical daily operation shows that the efficiency of the solar heating system, the adsorption cooling and the entirely solar cooling system is 28.4%, 45.2%, and 12.8%, respectively.  相似文献   

15.
L.J. He  L.M. Tang 《Solar Energy》2009,83(11):2029-2038
A theoretical analysis of the coefficient of performance was undertaken to examine the efficiency characteristics of R22 + DMF, R134a + DMF, R32 + DMF as working fluids, respectively, for a single-stage and intermittent absorption refrigerator which allows the use of heat pipe evacuated tubular collectors. The modeling and simulation of the performance considers both solar collector system and the absorption cooling system. The typical meteorological year file containing the weather parameters for Hangzhou is used to simulate the system. The results show that the system is in phase with the weather. In order to increase the reliability of the system, a hot water storage tank is essential. The optimum ratio of storage tank per solar collector area for Hangzhou’s climate for a 1.0 kW system is 0.035-0.043L. Considering the relative low pressure and the high coefficient of performance, R134a + DMF mixture presents interesting properties for its application in solar absorption cycles at moderate condensing and absorbing temperatures when the evaporating temperatures in the range from 278 K to 288 K which are highly useful for food preservation and for air-conditioning in rural areas.  相似文献   

16.
Solar thermal driven cooling systems for residential applications are a promising alternative to electric compression chillers, although its market introduction still represents a challenge, mainly due to the higher investment costs. The most common system configuration is an absorption chiller driven by a solar thermal system, backed up by a secondary heating source, normally a gas boiler. Heat storage in the primary (solar) circuit is mandatory to stabilize and extend the operation of the chiller, whereas a cold storage tank is not so common.This paper deals with the selection of the most suitable configuration for residential cooling systems with solar energy. In Spain, where cooling needs are usually higher than heating needs, the interest of a reversible heat pump as auxiliary system and a secondary cooling storage are analyzed.A complete TRNSYS model has been developed to compare a configuration with just hot storage (of typical capacity 40 L/m2 of solar collector surface) and a configuration with both, hot and cool storages. The most suitable configuration is very sensible to the solar collector area. As the collector area increases, the advantages of a cool storage vanish. Increasing the collector area tends to increase the temperature of the hot storage, leading to higher thermal losses in both the collector and the tank. When the storage volume is concentrated in one tank, these effects are mitigated. The effect of other variables on the optimal configuration are also analyzed: collector efficiency curve, COP of the absorption chiller, storage size, and temperature set-points of the chillers.  相似文献   

17.
Due to the increasing energy consumption of air conditioning in buildings and the need to decrease the fossil CO2 emissions to the environment, the interest of using renewable energy sources shows up stronger than ever.We present a general study whose aim is to propose a method to evaluate an upper bound in the potential of solar cooling by using some simplified models. As an example it has been applied to the very diverse climates of Spain. In the paper it has been assumed a direct solar coupling between the solar collector field and a single effect absorption cooling machine, without any intermediate solar storage tank. An equation is obtained that shows the dependence of the generator/solar-collectors equilibrium temperature on basic design parameters of the system (absorption machine-solar collectors). The paper analyzes the effect of these on the total amount of cooling produced along a typical mean year and the peak cooling power. The paper also includes a discussion on how to estimate the values and what is their physical meaning of the parameters which define the behavior of real absorption machines.Finally tables are included for the 12 climates of Spain that can be used as an example of how to make a quick pre-sizing of such direct coupled system. The classification of the Spanish climates is based on general data (average monthly total horizontal solar radiation, average monthly dry temperature, etc.) and the results could be generalized for climates with the same severity. Moreover if hourly weather data is available for any place (like tmy2, bin, epw, etc. files), the procedure can be applied without further changes.  相似文献   

18.
In 1998 two new technologies were demonstrated for the first time in a commercial building: (1) a new integrated CPC reflector evacuated solar collector (ICPC) and (2) the solar operation of a double effect absorption (2E) chiller. The 106.5 m2 ICPC collector array consisted of 336 evacuated tubes. A commercial 2E gas-fired absorption chiller was modified to operate with 150 °C hot water from the solar collector array. Daily collection efficiencies of nearly 50% and instantaneous collection efficiencies of about 60% were achieved throughout the first two years of operation. Daily chiller COPs of about 1.1 were also achieved.  相似文献   

19.
For the economical supply of solar process heat at temperatures between 120 and 150 °C a new non-tracking, flat, low-concentrating collector has been developed. The new collector is an edge ray collector with a concentration of 1.8 and inert gas filling, existing of parallel mounted absorber-reflector units, aligned in east-west direction. The basic concept is the integration of an absorber tube and reflectors inside a low pressure enclosure. Asymmetrical reflectors below the headers with a concentration of 0.6X provide extra radiation and prevent longitudinal radiation losses. To suppress heat losses due to gas-convection inside, air or inert gas like krypton at a pressure below 10 mbar is used.A prototype, with an aperture area of 2.0 m2, was tested in Munich and showed efficiencies of about 50% for krypton at 0.01 bar at a temperature of 150 °C with a radiation of 1000 W/m2 (900 W/m2 direct, ambient temperature 20 °C).  相似文献   

20.
A solar deep-freezing process has been designed. It aims at cooling down a cold box to about −20 °C, using simple flat plate solar collectors operating at 70 °C. This original process involves two cascaded thermochemical systems based on the BaCl2/ammonia reaction. Its working mode is discontinuous as it alternates between a regeneration mode during daytime and a cold production mode during nighttime. A global dynamic model involving the various system components allows the simulation of the process; it predicts the evolution of the components temperatures and the rates of chemical reactions of the system. It also allows the dimensioning of the system components to maintain a 500 l cold box at −20 °C during the 6 sunniest months of the year under typical Mediterranean weather conditions and provide over 80% of the total yearly cooling needs of this box. This requires a solar collector area of 5.8 m2 and 39 kg of reactive salt. The predicted coefficient of performance (COP) is about 0.1 over the year, and the net solar COP, taking into account the collector efficiencies, is 0.05.  相似文献   