1.
The performance of a solid sorption icemaker is investigated. CaCl2/activated carbon was used as compound adsorbent and ammonia was employed as adsorbate. The influence of operating conditions (cooling water temperature, mass recovery and heat pipe heat recovery, etc.) on the mass of ice, SCP (specific cooling power) and COP (coefficient of performance) was experimentally assessed. At the desorption temperature of 126 °C, cooling water temperature of 22 °C, ice produced temperature of −7.5 °C, 40 s of mass recovery and 2 min of heat pipe heat recovery, the mass of ice, SCP and COP values are 17.6 kg/h, 369.1 W/kg and 0.2, respectively.  相似文献   

2.
In order to settle the problem of the corrosion between sea water and the steel adsorber for ammonia system, a split heat pipe type adsorption ice making test unit, which use compound adsorbent of CaCl2 and activated carbon to improve the adsorption performance, is designed and constructed. For this test unit there is mass recovery function between two beds and the CaCl2 in compound adsorbent per bed is 1.88 kg, and there is only one pump for the whole heating and cooling phase for adsorbers. Performances of this system are tested; the lowest evaporating temperature is as low as −42 °C. At the evaporating temperature of −35 and −25 °C, the cooling powers are 0.89 and 1.18 kW, respectively. At the evaporating temperature of −15 °C, its average cooling power is 1.37 kW, which corresponds coefficient of performance of refrigeration COP=0.41 and specific cooling power per kilogram CaCl2 of each adsorber SCP=731 W kg−1. The mass recovery process has improved SCP and COP for the system by 15.5 and 24.1%, respectively. Heat transfer performance is also improved by the split heat pipe construction; the average heat transfer coefficient for a whole cycle is 155.8 W m−2 °C−1.  相似文献   

3.
Energy and exergy models for ideal adsorption cycles with isothermal beds and no mass recovery are developed to predict the limits to COP enhancement using thermal regeneration. The models are applied to compare the performance of zeolite–water and silica gel–water adsorbent–refrigerant pairs over a range of maximum bed temperatures. The thermodynamic consistencies of several alternate adsorption property assumptions are quantified. Differences in adsorption characteristics between zeolite–water and silica gel–water result in a significantly larger potential to enhance COP by implementing thermal regeneration for zeolite–water. Based on COP, the zeolite–water pair is preferred when both thermal regeneration and a high temperature thermal energy source (>150 °C) are used, while the silica gel–water pair is preferred when thermal regeneration is not used and/or a low temperature thermal energy source (<100 °C) is used.  相似文献   

4.
A thermodynamic cycle model is used to select an optimum adsorbent-refrigerant pair in respect of a chosen figure of merit that could be the cooling production (MJ m−3), the heating production (MJ m−3) or the coefficient of performance (COP). This model is based mainly on the adsorption equilibrium equations of the adsorbent–refrigerant pair and heat flows. The simulation results of 26 various activated carbon–ammonia pairs for three cycles (single bed, two-bed and infinite number of beds) are presented at typical conditions for ice making, air conditioning and heat pumping applications. The driving temperature varies from 80 °C to 200 °C. The carbon absorbents investigated are mainly coconut shell and coal based types in multiple forms: monolithic, granular, compacted granular, fibre, compacted fibre, cloth, compacted cloth and powder. Considering a two-bed cycle, the best thermal performances based on power density are obtained with the monolithic carbon KOH-AC, with a driving temperature of 100 °C; the cooling production is about 66 MJ m−3 (COP = 0.45) and 151 MJ m−3 (COP = 0.61) for ice making and air conditioning respectively; the heating production is about 236 MJ m−3 (COP = 1.50).  相似文献   

5.
A theoretical study of a novel regenerative ejector refrigeration cycle   总被引:1,自引:0,他引:1  
There has been a demand for developments of the ejector refrigeration systems using low grade thermal energy, such as solar energy and waste heat. In this paper, a novel regenerative ejector refrigeration cycle was described, which uses an auxiliary jet pump and a conventional regenerator to enhance the performance of the novel cycle. The theoretical analysis on the performance characteristics was carried out for the novel cycle with the refrigerant R141b. Compared with the conventional cycle, the simulation results show that the coefficient of performance (COP) of the novel cycle increases, respectively, by from 9.3 to 12.1% when generating temperature is in a range of 80–160 °C, the condensing temperature is in a range of 35–45 °C and the evaporating temperature is fixed at 10 °C. Especially due to the enhanced regeneration with increasing the pump outlet pressure, the improvement of COP of the novel cycle is approached to 17.8% compared with that in the conventional cycle under the operating condition that generating temperature is 100 °C, condensing temperature is 40 °C and evaporating temperature is 10 °C. Therefore, the characteristics of the novel cycle performance show its promise in using low grade thermal energy for the ejector refrigeration system.  相似文献   

6.
An adsorptive solar refrigerator was built and tested in May 1999 in Ouagadougou, Burkina-Faso. The adsorption pair is activated carbon + methanol. The adsorber is also the solar collector (2 m2, single glazed), the condenser is air-cooled (natural convection) and the evaporator contains 40 l of water that can freeze into ice. This amount of ice acts as a cold storage for the cold cabinet (available volume of 440 l). Elements such as valves and a graduated bottle are installed, but only for experimental purposes. Apart from these valves, and also ventilation dampers which are open at night time and closed at daytime, the machine does not contain any moving parts and does not consume any mechanical energy. Within the requirement of vacuum technology, the machine is relatively easy to manufacture, so that construction in Burkina-Faso is feasible. Experimental performance is presented in terms of gross solar COP. During the test period, irradiance were quite good (between 19 and 25 MJ m−2), but the ambient temperature was relatively warm (averagely 27.4 °C at sunrise and 37.4 °C at mid-afternoon). The experimental values of the gross solar COP lie between 0.09 and 0.13. Despite a warm climate, the performance of the machine compares favourably to previously published results.

Résumé

An adsorptive solar refrigerator was built and tested in May 1999 in Ouagadougou, Burkina-Faso. The adsorption pair is activated carbon + methanol. The adsorber is also the solar collector (2 m2, single glazed), the condenser is air-cooled (natural convection) and the evaporator contains 40 l of water that can freeze into ice. This amount of ice acts as a cold storage for the cold cabinet (available volume of 440 l). Elements such as valves and a graduated bottle are installed, but only for experimental purposes. Apart from these valves, and also ventilation dampers which are open at night time and closed at daytime, the machine does not contain any moving parts and does not consume any mechanical energy. Within the requirement of vacuum technology, the machine is relatively easy to manufacture, so that construction in Burkina-Faso is feasible. Experimental performance is presented in terms of gross solar COP. During the test period, irradiance were quite good (between 19 and 25 MJ m−2), but the ambient temperature was relatively warm (averagely 27.4 °C at sunrise and 37.4 °C at mid-afternoon). The experimental values of the gross solar COP lie between 0.09 and 0.13. Despite a warm climate, the performance of the machine compares favourably to previously published results.  相似文献   

7.
A single-stage vapour absorption refrigeration system (VARS) is tested with monochlorodifluoromethane (HCF22) as refrigerant and different absorbents: dimethylether of tetraethylene glycol (DMETEG) and dimethyl acetamide (DMA). The influence of generator temperatures in the range 75–95°C, which represents low-grade heat sources, is studied. Cooling water temperatures were varied between 20 and 30°C. Two cases of cooling water flow paths are considered, i.e. water entering either absorber or condenser, which are connected in series. For HCFC22-DMETEG, COP values in the range 0.2–0.36 and evaporator temperatures between 0 and 10°C are obtained. For HCF22-DMA, COP values in the range 0.3–0.45 and evaporator temperatures between −10 and 10°C are obtained. It is observed that HCFC22-DMETEG can work at lower heat source temperatures than HCFC22-DMA. However, at the same operating conditions HCFC22-DMA is better from the viewpoints of circulation ratio and COP. Experiments also show that at low heat source temperature, cooling water temperature has strong influence on circulation ratio but does not affect COP significantly. Preferably, cooling water should first flow through the condenser and then through the absorber in order to achieve improved overall performance.  相似文献   

8.
Adsorption performances and thermal conductivity were tested for three types of adsorbent: Pure CaCl2 powder, simple composite adsorbent and consolidated composite adsorbent. The simple composite adsorbents show better adsorption performance because the additive of expanded graphite in CaCl2 powder has restrained the agglomeration phenomenon in adsorption process and improved the adsorption performance of CaCl2. The consolidated composite adsorbent are suitable to be used as adsorbent for ice maker on fishing boats because they have higher thermal conductivity, larger volumetric cooling capacity, higher SCP values and better anti-sway performance than simple composite adsorbents. Thermal conductivity of the consolidated composite adsorbent is 6.5–9.8 W m−1 K−1 depending on the molding pressure, ranging from 5 to 15 MPa, which is about 32 times higher than the thermal conductivity of CaCl2 powder. The volumetric cooling capacity of consolidated composite adsorbent is about 52% higher than the best result obtained for CaCl2 at the evaporating temperature of −10 °C. The SCP of the consolidated adsorbent increases of about 353% than CaCl2 powder from simulation results at Tad=30 °C and Tev=−10 °C. The consolidated composite adsorbents have good anti-sway performance and they are not easy to be scattered out when the fishing boats sway on the sea.  相似文献   

9.
Thermal heat driven adsorption systems have been gained considerable attention on the recent energy utilization trend. However, the drawbacks of these adsorption systems are their poor performance. It is urgently necessary to improve the system performance of the adsorption cycles. There are two major ways for the system performance improvement. One is to develop new adsorbent material well suited to low temperature heat regeneration. The other is to enhance heat and mass transfer in the adsorber/desorber heat exchanger. The objective of the paper is to investigate the system performance of an adsorption cycle. The cycle utilizes activated carbon fiber (ACF)/methanol as adsorbent/refrigerant pair. In this paper, specific cooling effect SCE and COP of the system are numerically evaluated from the adsorption equilibrium theory with different hot, cooling and chilled fluid inlet temperatures. It is confirmed that the influences of hot, cooling and chilled fluid inlet temperatures on the system performance are qualitatively similar to those of silica gel/water pair. Even though, the driving temperature levels of ACF/methanol and silica gel/water are different. There is an optimum condition for COP to reach at maximum for ACF/methanol pair. Particularly, the ACF/methanol system shows better performance with lower chilled fluid inlet temperature between −20 and 20 °C.  相似文献   

10.
The prototype of a novel silica gel–water adsorption chiller is built and its performance is tested in detail. The experimental results show that the refrigerating capacity (RC) and COP of the chiller are 7.15 and 0.38 kW, respectively, when the hot water temperature is 84.8 °C, the cooling water temperature is 30.6 °C, and the chilled water outlet temperature is 11.7 °C. The RC will reach 6 kW under the condition of 65 °C hot water temperature, 30.5 °C cooling water temperature and 17.6 °C chilled water temperature. The results confirm that this kind of adsorption chiller is an effective refrigerating machine though its performance is not as fine as the prediction results. Also it is well effectively driven by a low-grade heat source. Therefore, its applications to the low-grade heat source are much attractive.  相似文献   