首页 | 官方网站   微博 | 高级检索  
相似文献
 共查询到10条相似文献,搜索用时 140 毫秒
1.
Vector quantization(VQ) can perform efficient feature extraction from electrocardiogram (ECG) with the advantages of dimensionality reduction and accuracy increase. However, the existing dictionary learning algorithms for vector quantization are sensitive to dirty data, which compromises the classification accuracy. To tackle the problem, we propose a novel dictionary learning algorithm that employs k-medoids cluster optimized by k-means++ and builds dictionaries by searching and using representative samples, which can avoid the interference of dirty data, and thus boost the classification performance of ECG systems based on vector quantization features. We apply our algorithm to vector quantization feature extraction for ECG beats classification, and compare it with popular features such as sampling point feature, fast Fourier transform feature, discrete wavelet transform feature, and with our previous beats vector quantization feature. The results show that the proposed method yields the highest accuracy and is capable of reducing the computational complexity of ECG beats classification system. The proposed dictionary learning algorithm provides more efficient encoding for ECG beats, and can improve ECG classification systems based on encoded feature.  相似文献   

2.
The purpose of this study is to evaluate the accuracy of the recurrent neural networks (RNNs) trained with Levenberg–Marquardt algorithm on the electrocardiogram (ECG) beats. Four types of ECG beats (normal beat, congestive heart failure beat, ventricular tachyarrhythmia beat, atrial fibrillation beat) obtained from the Physiobank database were analyzed. Decision making was performed in two stages: feature extraction by eigenvector methods and classification using the RNN trained on the extracted features. The RNNs were implemented for classification of the ECG beats using the statistical features as inputs. The ability of designed and trained Elman RNNs, combined with eigenvector methods, were explored to classify the ECG beats. The classification results demonstrated that the combined eigenvector methods/RNN approach can be useful in analyzing the ECG beats.  相似文献   

3.
鄢羽  孙成 《计算机应用》2014,34(7):2132-2135
为提高计算机辅助心电节拍分类算法的准确率和普适性,提出一种基于聚类分析的心电节拍分类算法,该算法利用心电节拍个体内差异性较小的特性,采用两级聚类分析、抽样代表性心电节拍的方法,结合心电医师的辅助诊断,实现对心电节拍的准确分类。为了验证算法的准确性,采用国际公认的标准数据库——MIT-BIH心律失常数据库,AAMI/ANSI标准规定的心电节拍分类方法及准确率的计算方法进行仿真实验,最终总体分类准确率达到99.07%。与Kiranyaz等(KIRANYAZ S, INCE T,PULKKINEN J, et al. Personalized long-term ECG classification: A systematic approach[J]. Expert Systems with Applications, 2011, 38(4): 3220-3226.)的心电节拍分类算法相比,该算法无需进行设定的训练,且S类心电节拍分类灵敏度由40.15%提高到89.82%,显著提高了分类算法的普适性。  相似文献   

4.
ECG beat classification by a novel hybrid neural network   总被引:10,自引:0,他引:10  
This paper presents a novel hybrid neural network structure for the classification of the electrocardiogram (ECG) beats. Two feature extraction methods: Fourier and wavelet analyses for ECG beat classification are comparatively investigated in eight-dimensional feature space. ECG features are determined by dynamic programming according to the divergence value. Classification performance, training time and the number of nodes of the multi-layer perceptron (MLP), restricted Coulomb energy (RCE) and a novel hybrid neural network are comparatively presented. In order to increase the classification performance and to decrease the number of nodes, the novel hybrid structure is trained by the genetic algorithms (GAs). Ten types of ECG beats obtained from the MIT-BIH database and from a real-time ECG measurement system are classified with a success of 96% by using the hybrid structure.  相似文献   

5.
针对短时傅里叶变换与小波变换对心电图(Electrocardiogram,ECG)信号特征提取不足以及心律失常识别困难的问题,提出了一种基于S变换特征选择的心律失常分类算法。首先对ECG信号进行S变换,并从幅值和相位两个角度提取ECG信号的时频特征,与形态特征和RR间隔组成原始特征向量。然后将遗传算法与支持向量机(Support vector machine,SVM)结合组成Wrapper式特征选择方法,并在其中融入ReliefF算法,即采用ReliefF算法计算特征权重,并根据特征权重大小来指导遗传算法种群初始化,遗传算法以SVM的分类性能作为适应度函数来搜索特征子集。最后使用"一对多"(One against all,OAA)SVM对MIT-BIH心律失常数据库8种类型心拍进行分类。实验结果表明,该算法达到了较好的分类效果,灵敏度、特异性和准确率分别为96.14%,99.75%和99.81%。  相似文献   

6.
心电分类是一种复杂的模式识别问题。目前,大部分基于不同机器学习模型的心电分类方法都取得了很高的分类精度,但学习效率不高,因此需要一种快速的心电学习方法。文章提出了基于多种核函数的超限学习方法,利用不同的核函数将特征映射到希尔伯特空间,使心电数据在高维空间中线性可分,并在 MIT-BIH 标准库进行了该方法的实验验证。与其他方法相比,文章所提出的方法具有较高的分类准确率和更快的学习速度,对临床上动态心电图的检测与分析和个性化的实时心电监测具有重要意义。  相似文献   

7.
In this study, a new supervised noise-artifact-robust heart arrhythmia fusion classification solution, is introduced. Proposed method consists of structurally diverse classifiers with a new QRS complex geometrical feature extraction technique.Toward this objective, first, the events of the electrocardiogram (ECG) signal are detected and delineated using a robust wavelet-based algorithm. Then, each QRS region and also its corresponding discrete wavelet transform (DWT) are supposed as virtual images and each of them is divided into eight polar sectors. Next, the curve length of each excerpted segment is calculated and is used as the element of the feature space. Discrimination power of proposed classifier in isolation of different Gold standard beats was assessed with accuracy 98.20%. Also, proposed learning machine was applied to 7 arrhythmias belonging to 15 different records and accuracy 98.06% was achieved. Comparisons with peer-reviewed studies prove a marginal progress in computerized heart arrhythmia recognition technologies.  相似文献   

8.
This paper describes feature extraction methods using higher order statistics (HOS) of wavelet packet decomposition (WPD) coefficients for the purpose of automatic heartbeat recognition. The method consists of three stages. First, the wavelet package coefficients (WPC) are calculated for each different type of ECG beat. Then, higher order statistics of WPC are derived. Finally, the obtained feature set is used as input to a classifier, which is based on k-NN algorithm. The MIT-BIH arrhythmia database is used to obtain the ECG records used in this study. All heartbeats in the arrhythmia database are grouped into five main heartbeat classes. The classification accuracy of the proposed system is measured by average sensitivity of 90%, average selectivity of 92% and average specificity of 98%. The results show that HOS of WPC as features are highly discriminative for the classification of different arrhythmic ECG beats.  相似文献   

9.
This paper presents an application of a hybrid neural network structure to the classification of the electrocardiogram (ECG) beats. Three different feature extraction methods are comparatively examined: discrete cosine transform, wavelet transform and a direct method. Classification performances, training times and the numbers of nodes of Kohonen network, Restricted Coulomb Energy (RCE) network and the hybrid neural network are presented. To increase the classification performance and to decrease the number of nodes, the hybrid neural network is trained by Genetic Algorithms (GAs). Ten types of ECG beats obtained from the MIT-BIH database and from a real-time ECG measurement system are classified with a success of 98% by using the hybrid neural network structure and discrete cosine transform together.  相似文献   

10.
Abstract: Mixture of experts (ME) is a modular neural network architecture for supervised learning. This paper illustrates the use of the ME network structure to guide model selection for classification of electrocardiogram (ECG) beats. The expectation maximization algorithm is used for training the ME so that the learning process is decoupled in a manner that fits well with the modular structure. The ECG signals were decomposed into time–frequency representations using discrete wavelet transforms and statistical features were calculated to depict their distribution. The ME network structure was implemented for ECG beats classification using the statistical features as inputs. To improve classification accuracy, the outputs of expert networks were combined by a gating network simultaneously trained in order to stochastically select the expert that is performing the best at solving the problem. Five types of ECG beats (normal beat, congestive heart failure beat, ventricular tachyarrhythmia beat, atrial fibrillation beat, partial epilepsy beat) obtained from the Physiobank database were classified with an accuracy of 96.89% by the ME network structure. The ME network structure achieved accuracy rates which were higher than those of the stand-alone neural network models.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司    京ICP备09084417号-23

京公网安备 11010802026262号