首页 | 官方网站   微博 | 高级检索  
相似文献
 共查询到10条相似文献,搜索用时 277 毫秒
1.
《Ergonomics》2012,55(12):1617-1631
Abstract

Intrinsic thermal clothing insulation and surface air insulation were measured on human subjects by the use of indirect calorimetry. Four male clothing ensembles (0-1-1 -8 clo) and three female clothing ensembles (0-2-1-2 clo) were investigated. Using the standing position as a reference, the influence of sitting, bicycling (40r.p.m., 20 W), walking (3-75 km hour?1) and of light packing work on the thermal insulation was studied. The influence of an air velocity of 11ms?1 on thermal insulation during the standing and walking conditions was investigated. The results showed that: (i) intrinsic clothing insulation was maximal in the standing position. It was reduced by 8-18% in the seated position and by 30-50% during bicycling and walking. An air velocity of 11ms?1 did not influence the intrinsic clothing insulation during walking, but decreased it by 18% in the standing position; (ii) surface air insulation varied with activity and air velocity, but not with clothing. It was increased by up to 25% in the seated position, reduced by 7-26% during bicycling and by 30-50% during walking. An air velocity of 11 ms-1 reduced the surface air insulation by 50% in the standing position and 30% during walking.  相似文献   

2.
Combinations of clothing provide different degrees of thermal insulation for various parts of the body. The effect of this uneven thermal insulation on general comfort is examined by using experimental clothing which could provide varying degrees of thermal resistance. The relationship between skin temperature and sensation was found to be approximately linear when the exposed areas were not large, and that clothing of the same thermal resistance can yield different sensations depending on the parts of the body involved.  相似文献   

3.
The assessment of heat radiation   总被引:3,自引:0,他引:3  
Approximately 900 climatic chamber experiments were performed with 16 male subjects to study the thermal strain at climates including increased heat radiation. Based on the reactions of heart rate, rectal temperature and sweat rate, a heat stress index was developed for the assessment of climates with effective heat radiation intensities up to 1400 W m−2. The index considers different combinations of dry air temperature (5–55°C), globe temperature (25–76°C), mean radiant temperature (25–160°C), air velocity (0.5–2.0 m s−1), clothing, physical work load and directions of radiation and air flow.

The index integrates combinations of the variables producing the same degree of thermal strain into a single value. This value indicates the temperature of the physiologically equivalent climate in which air and radiant temperature are equal. It can be determined from a simple formula or from correspondent graphs.

In comparison, the international recommended heat stress indices are less capable to evaluate heat radiation correctly. The incorporation of the new partial index into the used indices may improve substantially their physiological validity in the assessment of climates with radiant heat stress.

Relevance to industry

The goal of this paper is to provide an improved assessment of thermal stress in working environments in which heat radiation is an important heat stress factor.  相似文献   


4.
A novel design of personal cooling clothing incorporating additional insulation sandwiched between phase change materials (PCMs) and clothing outer layer is proposed. Performance of four personal cooling systems including clothing with only PCMs, clothing with PCMs and insulation (PCM?+?INS), clothing with PCMs and ventilation fans (HYB), and clothing with PCMs, ventilation fans and insulation (HYB?+?INS) was investigated. Effect of additional insulation on clothing cooling performance in terms of human physiological and perceptual responses was also examined. Human trials were carried out in a hot environment (i.e. 36?°C, RH = 59%). Results showed that significantly lower mean skin/torso temperatures were registered in HYB?+?INS as compared to HYB. In contrast, no significant effect of the use of insulation on both skin and body temperatures between PCM and PCM?+?INS was observed. Also, no significant difference in thermal sensations, thermal comfort, and skin wetness sensation was registered between cooling systems with and without additional insulation.

Practitioner Summary: Hybrid personal cooling clothing has shown the ability to provide a relatively cool microclimate around the wearer’ body while working in hot environments. The present work addresses the importance of cooling energy saving for PCMs in a hot environment. This work contributes to optimising cooling performance of hybrid personal cooling systems.  相似文献   


5.
Lee Y  Hong K  Hong SA 《Applied ergonomics》2007,38(3):349-355
Garment fit and resultant air volume is a crucial factor in thermal insulation, and yet, it has been difficult to quantify the air volume of clothing microclimate and relate it to the thermal insulation value just using the information on the size of clothing pattern without actual 3D volume measurement in wear condition. As earlier methods for the computation of air volume in clothing microclimate, vacuum over suit and circumference model have been used. However, these methods have inevitable disadvantages in terms of cost or accuracy due to the limitations of measurement equipment. In this paper, the phase-shifting moiré topography was introduced as one of the 3D scanning tools to measure the air volume of clothing microclimate quantitatively. The purpose of this research is to adopt a non-contact image scanning technology, phase-shifting moiré topography, to ascertain relationship between air volume and insulation value of layered clothing systems in wear situations where the 2D fabric creates new conditions in 3D spaces. The insulation of vests over shirts as a layered clothing system was measured with a thermal manikin in the environmental condition of 20 degrees C, 65% RH and air velocity of 0.79 m/s. As the pattern size increased, the insulation of the clothing system was increased. But beyond a certain limit, the insulation started to decrease due to convection and ventilation, which is more apparent when only the vest was worn over the torso of manikin. The relationship between clothing air volume and insulation was difficult to predict with a single vest due to the extreme openings which induced active ventilation. But when the vest was worn over the shirt, the effects of thickness of the fabrics on insulation were less pronounced compared with that of air volume. In conclusion, phase-shifting moiré topography was one of the efficient and accurate ways of quantifying air volume and its distribution across the clothing microclimate. It is also noted that air volume becomes more crucial factor in predicting thermal insulation when clothing is layered.  相似文献   

6.
《Ergonomics》2012,55(12):1689-1703
Subjective and physiological responses were obtained from six subjects wearing a face mask while exercising (220 W m ?2) for 15 min on a bicycle ergometer. Different combinations of ambient air temperatures (7, 16 and 25°C) and mask air temperatures (22,27 and 33°C) were studied with two different air humidities inside the mask (61 and 86% relative humidity (RH)). Control experiments were performed without the mask at the same ambient temperatures. Skin temperatures, heart rates and skin wettedness were monitored during exercise. The subjects’ thermal sensations, sensations of sweating and skin wettedness and their thermal preferences were assessed at the end of the exercise period. Whole body thermal sensation was primarily determined by the ambient air temperature, but was also significantly influenced by the mask air temperature. This could only partly be explained by the change in respiratory heat loss. Other possible avenues of influence are discussed.  相似文献   

7.
An ecotone is a zone of vegetation transition between two communities, often resulting from a natural or anthropogenic environmental gradient. In remotely sensed imagery, an ecotone may appear as an edge, a boundary of mixed pixels or a zone of continuous variation, depending on the spatial scale of the vegetation communities and their transition zone in relation to the spatial resolution of the imagery. Often in image classification, an ecotone is either ignored if it falls within a width of one or two pixels, or part of it may be mapped as a separate vegetation community if it covers an area of several pixel widths. A soft classification method, such as probability mapping, is inherently appealing for mapping vegetation transition. Ideally, the probability of membership each pixel has to each vegetation class corresponds with the proportional composition of vegetation classes per pixel. In this paper we investigate the use of class probability mapping to produce a softened classification of an alpine treeline ecotone in Austria using a SPOT 5 HRG image. Here the transition with altitude is from dense subalpine forest to treeless alpine meadow and herbaceous vegetation. The posterior probabilities from a Maximum Likelihood algorithm are shown to reflect the land-cover composition of mixed pixels in the ecotone. The relationships between the posterior probability of class membership for the two end-member classes of ‘scrub and forest’ and ‘non-forest vegetation’ and the percentage ground cover of these vegetation classes (enumerated in 15 quadrats from 1:1500 aerial photographs) were highly significant: r2 = 0.83 and r2 = 0.85 respectively (p < 0.001, n = 15). We identify thresholds (alpha-cuts) in the posterior probabilities of class membership of ‘scrub and forest’ and ‘non-forest vegetation’ to map the alpine treeline ecotone as a transition zone of five intermediate vegetation classes between the end-member communities. In addition, we investigate the representation of the ecotone as a ratio between the posterior probabilities of ‘scrub and forest’ and ‘non-forest vegetation’. This displays the vegetation transition without imposing subjective boundaries, and has greater emphasis on the ecotone transition rather than on the end-member communities. We comment on the fitness for purpose of the different ways investigated for representing the alpine treeline ecotone.  相似文献   

8.
为满足室内人员在不同着装时的热舒适需求,以某层式通风供暖办公室为研究对象,在考虑不同服装热阻的前提下,通过改进TOPSIS法优化了送风参数(即送风角度、送风速度和送风温度);在优化过程中,将PMV/PPD、垂直温差、空气龄和能量利用效率作为通风性能评价指标,以送风温度、送风速度、送风角度和服装热阻为设计变量,通过CFD模拟分析,采用中心复合设计响应面法得到通风性能与设计变量间的函数关系,然后用于改进TOPSIS法评估所有可能方案的通风性能以达到提高计算效率的目的;结果表明:基于改进TOPSIS法优化层式通风供暖送风参数可以显著改善通风性能,PPD、空气龄和垂直温差分别平均降低了37.08%、22.46%和48.17%,能量利用效率平均提高了20.42%。  相似文献   

9.
《Ergonomics》2012,55(10):963-974
This study was undertaken in order to analyse the importance of the pumping effect on clothing's thermal insulation. To enhance differences in heat exchanges due to the pumping effect, two sets of condition were fixed, minimizing either the convective or the radiative heat transfers. The results showed that: (i) the clothing insulation determined on a manikin, even if he is moving, is larger than the resultant clothing insulation for living subjects; (ii) the insulation is not the same for radiant heat or cold as for convective heat or cold;(iii) the pumping effect can increase or decrease the resultant clothing insulation; (iv) the clothing insulation is smaller in warmer conditions thanin cooler ones; (v) it becomes necessary to make a definite distinction between several kinds of clothing insulation; intrinsic or basic insulation against radiation and convection; effective insulation against radiation and convection taking into account only the heat flowing through the clothing fabric; resultant insulation taking into account the magnitude of the pumping effect when clothing is worn by living subjects  相似文献   

10.
When a work scenario in protective clothing is a nominal two hours of work followed by a short break, the level of heat stress must be limited to conditions of thermal equilibrium. By comparing changes in maximum sustainable work rate in a fixed environment, differences due to different protective clothing ensembles can be determined. To illustrate this principle, two protective clothing ensembles were examined. The Basic Ensemble was a cotton blend coverall over gym shorts with hard hat, gloves and full face mask respirator. The Enhanced Ensemble added a light weight, surgical scrub suit under the coveralls, plus a hood worn under the hard hat. Five young, acclimated males were the test subjects. Environmental conditions were fixed at Tdb=32°C and Tpwb=26°C. After a physiological steady state was established at a low rate of work, treadmill speed was increased by 0.04 m/s every 5 min. The trial continued until thermal equilibrium was clearly lost. A critical treadmill speed was noted at the point thermal equilibrium was lost for each ensemble and subject. The drop in treadmill speed from the basic to enhanced ensemble was 11%. Based on measured values of average skin temperature and metabolic rate at the critical work rate and estimated values of clothing insulation, the average evaporative resistances for the basic and enhanced ensembles were 0.018 and 0.026 kPa m2/W, respectively.

Relevance to industry

Protective clothing decisions are based on the need to reduce the risk of skin contact with chemical or physical hazards. Sometimes over-protection of the skin results in a hazard secondary to the skin, such as heat stress. With or without over-protection, protective clothing decisions may affect the level of heat stress and result in lower rates of sustainable work. This paper illustrates the affects of a relatively small change in protective clothing requirements on the ability to work in the heat.  相似文献   