首页 | 官方网站   微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
2.
The Fifth Annual Conference on Flame Retardancy was held May 24–26, 1994, at the Ramada Plaza Hotel, Stamford, Connecticut, USA. The conference was organized by Business Communications Company, Inc., Norwalk, Connecticut (Company President, Mr. Louis Naturman; Conference Coordinator, Mrs. Sharon D. Faust). New materials (polymers, blends, composites), their applications, industry developments, and markets were considered. Specifically, the most important topics were:

Introduction of new technological achievements and development in the field of flame retardancy (FR)

Review of the current state of science and technology in FR

Review of applications and markets for FR products

Presentation of recent developments in local and global standardization and in testing technology

Discussion of toxicity and environmental issues

Provision of a unique opportunity for newcomers to FR research technology and marketing to become acquainted with the FR field in all its aspects

Discussion of halogen-based and non-halogen-based flame retardant chemicals, syngergism, intumescence, FR mechanisms, modeling, flame parameters, inherently FR polymers, and polymer blends  相似文献   


3.
This paper presents results from a water treatment pilot testing program in Winnipeg, Canada (pop. 650,000) which evaluated a DAF/ozone/deep bed filtration process. As part of the testing program, biological filtration using GAC and anthracite media was assessed for the removal of ozone DBPs and background chlorine DBPs (due to upstream chlorination of the source water). The results were used to evaluate the effectiveness of biological filtration for DBP removal.

High filtration rates were tested in this study. The 2.1m deep filters were run at a hydraulic loading rate (HLR) of 35 m/h with an empty bed contact time (EBCT) of only 3.6 minutes.

The important findings of this work are

?The high-rate biologically active carbon (BAC) filters met the objective of controlling ozone DBPs. These results confirm that high rate, low EBCT filters can provide significant biodegradation. Anthracite biofilters provided significantly less removal of ozone DBPs.

?The high rate BAC filters showed significant reduction of background HAAs. BAC reduced the background HAAs to below the long-term target of 30 μg/L. Anthracite biofilters did not exhibit HAA removal.

?Biological filtration with either media was ineffective for background THM removal. The long-term target of 40 μg/L could not be achieved without GAC adsorption.  相似文献   


4.
Experimental studies were carried out on the removal of five species of aromatic nitro hydrocarbons by ozonation. Ultraviolet spectrograms with distinct absorption peaks were plotted for each of them. It has been found that the absorbances of aqueous solutions containing the single compounds mentioned above increase to different extents at the wave lengths ranging from 200 to 230 nanometers with increase of ozone dosages. This is ascribed to the nitrite ions splitting out of the benzene rings and being further oxidized to nitrate ions by ozonation.

It has been indicated that the removal of the five species of aromatic nitro compounds by ozonation can well be expressed mathematically by first order reaction equations. Besides, the reaction constants and half-life periods for various species of the tested nitro compounds were calculated at different temperatures and pH.

An ozonation effect index (OI) was developed in the study to express the degree of degradation of substrates by ozonation, by means of which the five aromatic nitro hydrocarbons were compared with each other and finally ranked in the following order from greatest to smallest degrees of degradation:

p-nitroaniline > nitrobenzene > p-dinitrobenzene > p-nitrotoluene > m-dinitrobenzene

It has also found that the CODm/M ratio increases with ozone doses. This means that some easily degradable intermediates are produced, and increase in concentration with increase of ozone dose in the ozonation process.

The mechanisms of removing the five aromatic nitro hydrocarbons are discussed from the viewpoint of orienting effects of substituent groups on the aromatic rings.  相似文献   


5.
The conventional blown process imparts an inherent haze to the product. The percentage of haze varies with certain process variables:

1. Surface irregularities caused by melt flow phenomena

2. Crystallization behavior

3. Melt drawing phenomena in certain types of polyethylene  相似文献   


6.
During drinking-water treatment, ozone used as a preoxidant and chlorine required for final disinfection, lead to competing chemical reactions, in the case of raw water containing both organic compounds and inorganic salts (such as bromides and ammonia).

The study of the interactions between those reactants has been made according to the following main topics :

As for THM formation, experiments conducted on simple organic compounds or on natural fulvic acids show important decreases in THM or TCAA formation after ozonation. It may be noticed, however, that the ozonation of surface waters may induce the formation of haloform precursors, usually with a low level of reactivity.

In water supplies containing bromide ions, oxidation of the latter through hypobromous acid may take place during the ozonation stage. Failing preozonation treatment, hypobromous acid is generated very rapidly during chlorination, thus inducing the formation of chloro- brominated organic compounds.

During the ozonation of fulvic acid solutions, the presence of small amounts of bicarbonate was found to improve precursor removal significantly.

It can be concluded that the partial analogy of the action of ozone or chlorine on aromatic structures, whether simple or complex (such as humic and fulvic acids), seems to indicate that the consequence of preozonation is the destruction, at least in part, of the most reactive sites for THM production, thus leading to a decrease of the volatile organochlorinated compounds formed during the post-chlorination. However, some ozonation products of natural waters are THM precursors, though of low reactivity. Then, in the presence of bromide ions, the formation of volatile organobrominated compounds may be observed during ozonation.  相似文献   


7.
The article presents a mathematical model for calculation of nonstationary hydraulic and separation processes in a gas centrifuge (GC) cascade for separation of multicomponent isotope mixtures. The model has been applied to calculate the parameters of nonstationary processes in a GC cascade for separation of krypton, germanium and tungsten isotopes. As a result, the specifics of the excess holdup distribution along the cascade stages has been identified, and variations of the isotope concentrations in a nonstationary process have been revealed. The data obtained show that the proposed mathematical model is able to adequately describe nonstationary hydraulic processes in GC cascades for separation of multicomponent isotope mixtures.

Highlights:

Mathematical model of cascade for separation of multicomponent isotope mixture has been developed.

The model verification has been done.

The isotope transient regularities into cascade during nonstationary processes has been identified.  相似文献   


8.
Six distillation column models have been used in studies of the usefulness of the Inverse Nyquist Array (INA) method for design of dual composition control for distillation. Five of the column models are experimental, one describing an industrial column, the others four pilot plants. One column model is obtained by modeling from first principles.

The control strategies investigated and compared are multiloop SISO, 2-way decoupling and l-way decoupling. The control variables are the standard ones, i.e. reflux flow and boilup.

In most of the cases INA has been found to be a useful tool for design of the loops and for comparison of the different control approaches. INA has also been found to be useful for simultaneous tuning of the decouplers and the feedback controllers.

For 2-way decoupling the criterion to minimize interaction at the critical frequency for each primary feedback loop has been found useful in most, but not all, cases. The scheme can be designed by pure gains in the decouplers and there is no reason to introduce dynamics into the decouplers—the systems studied are already sufficiently rich in dynamics.

INA has been found to be a suitable vehicle for the choice between the two possible l-way decoupling schemes.

With the design approach taken, l-way decoupling has been found to provide considerably better control quality than 2-way decoupling in two of the six systems, the differences in control quality being small in the other cases.

The effect of model mismatching on the results, caused e.g. by process nonlinearities, is discussed and simple rules to decrease the parameter sensitivity for 2-way decoupling schemes are given. When model mismatching is considered, the advantage of l-way decoupling over 2-way decoupling seems to increase.

One deficiency of the INA design as used in this paper is that it does not single out the design which is to be preferred on the grounds of robustness.  相似文献   


9.
The field of performance plastics is showing remarkable vitality and growth, even though the participants find the price to be high in terms of technical and sales support required, together with high capital investment for plants.

There has been a high degree of proliferation of new products in the form of new polymers, new grades of existing polymers, as well as filled, reinforced, alloyed versions. While this does introduce new degrees of freedom in material selection, it is a source of significant confusion for the design engineers who have to cope with selecting the preferred material from among the many that are available. The choices and data bases are becoming confusing.

Various forms of relatively exotic, aromatic-monomer chemistry are being applied, but the emphasis appears to be on new amorphous polymers.

High-performance requirements exist in virtually all segments of the plastics field; the major end uses are in aerospace, automotive, business machines, electrical/electronics, food packaging, and medical applications.

Foreign presence has strongly increased as European companies have increased imports or have purchased established product lines or business units.

There will be continued pressure on the performance plastics from the lower priced materials which are countering with upgraded, modified, alloyed versions of their own. There is also increased competition between thermoplastics and thermosets as the result of material developments and process refinements.  相似文献   


10.
The two corona discharge ozone swimming pool water treatment systems installed in the Peck Aquatic Center in Milwaukee, WI now have been in continuous operation since September, 1987. The two pools are part of the Karl Jewish Campus Facility of the Harold and Judy Sampson Campus of the Milwaukee Jewish Community Center.

The operation of these water treatment systems has shown that safe and high quality pool water is obtained reliably and economically. One pool (Main Pool) is of Olympic size, the other (Learner pool) is designed especially for use by children. Both pools utilize a full corona discharge ozone water treatment system. They were the first ozone systems in the U.S. to be built for public pools using the process of ozonation, flocculation, filtration, ozone removal and residual chlorination.

An extensive testing program was initiated in cooperation with the Wisconsin Department of Health. The bacteriological water quality from these swimming pools was in compliance with Wisconsin State Health Regulations and the German DIN Standard 19,643.

The first year of operation of the Peck Aquatic Center has shown that the corona discharge ozone pool water treatment process can:

1) Operate reliably in a public swimming pool environment without the need for highly or special operator qualifications.

2) Produce continuously bacteria- and virus-free pool water without the harmful and unpleasant effects of chlorine.

3) Creates a user constituency group praising and promoting the use of “minimal chlorine swimming” in the community.  相似文献   


11.
The purpose of this study was to point out processes that can provide triazine oxidation via hydroxyl radical production in a water treatment line. We focus our attention on:

- oxido-flocculation, using Fe2+, H2O2

- inter-oxidation, using O3, H2O2 and eventually an heterogeneous catalyst.

- disinfection, using UV, O3 and H2O2 combinations.

Results show that triazines can be removed by all these processes with different efficiencies. At full scale, the O3/H2O2 process presents the best performances from an economical and technical point of view.  相似文献   


12.
The treatment chemical ozone has now been successfully used in the United States in municipal water and wastewater plants for many years. To insure continuous, successful operations of these applications, operating obstacles had to be dealt with and overcome.

In this paper, examples of field operating problems and their solutions are described. The experiences at specific municipal water and wastewater installations are reviewed in detail. Discussed for each example are : the background and effects of the problem, the problem-solving process, and the eventual resolution of the problem. The examples include simple unit operations to entire processes.

By observing the ozone installation's operation several years after start-up, the design of future ozone systems can be improved and operating problems minimized.  相似文献   


13.
The theory of gas absorption accompanied by fast pseudo-fast order reaction which considered dependences of diffusivity, kinetic constant and Henry's law constant on absolute temperature and ionic strength was used to obtain values of effective interfacial areas and mass transfer coefficients in gas and liquid phase.

Experimental measurement of carbon dioxide absorption from mixture with air was performed in a pilot-plant column with expanded metal sheet packing irrigated with sodium hydroxide solution.

Resulting liquid and gas-side mass transfer coefficients are compared with values obtained from physical Absorption measurement of carbon dioxide into water and with measurement of gas-side mass transfer coefficient for sulphur dioxide in the same column.

The differences between determined values are discussed.  相似文献   


14.
A new concept of molecular cluster dynamics in turbulent flows is used to develop a physical model and mechanism of homogeneous and heterogeneous nucleation in solutions. The proposed physical model considers the motion of molecular clusters in centrifugal fields of free eddies induced in turbulent flows. The clusters are moved to an eddy boundary region where they are concentrated and aggregated to form critical nuclei.

It is shown theoretically that a critical fluid velocity exists, below which nuclei are not formed, and that its value depends upon the degree of solution supersaturation. The nucleation theory takes into account the hydrodynamic parameters of the process and permits calculation of the number of nuclei formed. Satisfactory agreement was obtained between calculated values and published experimental data.  相似文献   


15.
This paper reflects an investigation of the feasibility of photochemical generation of ozone by irradiating gases containing oxygen with Hg lamps of the highest performance emitting the 185 nm line. Besides the expected photostationary equilibrium, determining factors for practical yields in ozone generation by the 185 nm wavelength are : the reactor and gas temperature, the reactor geometry, and the gas composition, as well as the pressure.

Further developments are expected in the field of lamp construction and also improvement of reactor geometry. A better knowledge of the aging of the lamps is required, as well as of the photochemical reactions of oxygen in the technologies applied.

Systems presently available are most promising for application on small scale or in areas of public water distribution which have no developed structure.

  相似文献   


16.
Accurate exposure assessments are needed to evaluate health hazards caused by airborne microorganisms and require air samplers that efficiently capture representative samples. This highlights the need for samplers with well-defined performance characteristics. While generic aerosol performance measurements are fundamental to evaluate/compare samplers, the added complexity caused by the diversity of microorganisms, especially in combination with cultivation-based analysis methods, may render such measurements inadequate to assess suitability for bioaerosols. Specific performance measurements that take into account the end-to-end sampling process, targeted bioaerosol and analysis method could help guide selection of air samplers.

Nine different samplers (impactors/impingers/cyclones/ electrostatic precipitators/filtration samplers) were subjected to comparative performance testing in this work. Their end-to-end cultivation-based biological sampling efficiencies (BSEs) and PCR-/microscopy-based physical sampling efficiencies (PSEs) relative to a reference sampler (BioSampler) were determined for gram-negative and gram-positive vegetative bacteria, bacterial spores, and viruses.

Significant differences were revealed among the samplers and shown to depend on the bioaerosol's stress–sensitivity and particle size. Samplers employing dry collection had lower BSEs for stress-sensitive bioaerosols than wet collection methods, while nonfilter-based samplers showed reduced PSEs for 1 μm compared to 4 μm bioaerosols. Several samplers were shown to underestimate bioaerosol concentration levels relative to the BioSampler due to having lower sampling efficiencies, although they generally obtained samples that were more concentrated due to having higher concentration factors.

Our work may help increase user awareness about important performance criteria for bioaerosol sampling, which could contribute to methodological harmonization/standardization and result in more reliable exposure assessments for airborne pathogens and other bioaerosols of interest.

Copyright 2014 American Association for Aerosol Research  相似文献   


17.
18.
Primary biological aerosol particles (PBAP) such as pollen and fungal spores can induce allergenic responses and affect health in general. Conditions such as allergic rhinitis (hay fever) and asthma have been related to pollen concentrations. Likewise some pollen have been shown to induce ice nucleation and cloud condensation at higher temperatures than those associated with some chemical species, thereby affecting planet Earth's albedo and overall radiative balance. Hence, the near real-time (on-line) monitoring of airborne pollen and other PBAP using a variety of spectroscopic and light scattering techniques represents an area of growing development and consequence.

In this study, two separate field campaigns (one at a rural site in Ireland and the other at an urbanized location in Germany) were performed to detect and quantify pollen releases using a novel on-line fluorescence spectrometer (WIBS-4). The results were compared with results obtained using more traditional Hirst-type impactors. Size, “shape,” and fluorescence characteristics of ambient particles were used to determine the concentrations and identity of the PBAP likely to be pollen grains.

The concentration results obtained for both methodologies at both the Irish and German sites correlated very well, with R 2 values >0.9 determined for both campaigns. Furthermore, the sizing data available from the WIBS-4 approach employed in Ireland indicated that pollen grains can be identified in appropriate conditions. WIBS-4 measurements of Yew pollen both in the laboratory and at the rural site indicated almost identical size ranges of 25 to 27 μm. Yew pollen is generally reported to be in this range, but the measurements reported here are the first of their type providing data on the size of in-flight Yew pollen.

Copyright 2014 American Association for Aerosol Research  相似文献   


19.
Many well-established models can be applied to calculate the filtration efficiencies. In these models the filtration velocity and challenging particle size are assumed to be known accurately. However, in realistic filtration tests, the filtration velocity has profiles dependent on the filter holder geometry and experimental conditions; the challenging particles have size distributions dependent on the instruments and operation conditions. These factors can potentially affect the measured filtration efficiency and lead to discrepancies with the models.

This study aims to develop an integrative model to predict the filtration efficiencies in realistic tests by incorporating the effects of the filtration velocity profile and challenging particle size distribution classified by a differential mobility analyzer (DMA) into the existing filtration models. Face velocity profile is modeled with fluid mechanics simulations; the initial generated particle size distribution, the particle charging status and the DMA transfer function are modeled to obtain the challenging particle size distribution. These results are then fed into the filtration models. Simulated results are compared with experimental ones to verify the model accuracy. This model can be used to reduce filtration test artifacts and to improve the experimental procedure.

The results reveal that the face velocity upstream the filter exhibits high degree of homogeneity not affecting the filtration efficiency if the filter pressure drop is not very low. The generated particle size distribution and the DMA selection size window could influence the challenging particle size distribution and therefore the measured filtration efficiency.

Copyright © 2017 American Association for Aerosol Research  相似文献   


20.
An extensive array of literature data on the heat transfer from a reactor wall to a fluid flowing through a packed bed and those obtained from some experimental runs were interpreted with a model containing two parameters: ke, (effective radial thermal conductivity within the bed) and hw (heat transfer coefficient at the wall).

Both parameters were considered in terms of a stagnant contribution (due to the heat conduction through the solid particles and the fluid in the void space) and a radial mixing contribution (due to the heat convection by turbulent mechanism.

The stagnant contribution was interpreted with a model similar to that proposed by Kunii and Smith (1966) for heat transfer in a packed bed with motionless fluid.

General correlating equations for calculating the stagnant and the turbulent contributions of both ke, and hw are proposed.  相似文献   


设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司    京ICP备09084417号-23