首页 | 官方网站   微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
The paper reports the results of an investigation on a H-SSF constructed wetland for tertiary treatment in a small community located in eastern Sicily, Italy. The system is designed to reuse wastewater for the irrigation of olive orchards covering about 150 hectares. From March 2001 to September 2005, wastewater samples were collected and the following chemical-physical parameters were determined according to Standard Methods: temperature, pH, EC, DO, TSS (105degrees C), BOD5, COD, TN, TP. The following microbiological parameters were also evaluated: total coliforms, faecal coliforms, Escherichia coli, faecal streptococci, Salmonella, helminth eggs. Mean removal efficiencies ranged from 77 to 92% (TSS), 37 to 72% (BOD5), 51 to 79% (COD), 97 to 99.5% (E. coli). Removal efficiency of Salmonella and helminth eggs was always 100% in all samples; however, only 150% of total samples matched the limit of E. coli (< 50 CFU/100 mL) fixed by Italian legislation for wastewater reuse.  相似文献   

2.
One of the limits for the application of constructed wetlands (CWs) in mountain regions (such as the Alps) is associated with the considerable land area requirements. In some mountain areas, the treatment of domestic wastewater at popular tourist destinations is particularly difficult during the summer, when the presence of visitors increases hydraulic and organic loads. This paper aims to evaluate whether a hybrid CW plant designed on the basis of the resident population only, can treat also the additional load produced by the floating population during the tourist period (summer, when temperatures are favourable for biological treatment), without a drastic decrease of efficiency and without clogging problems. The research was carried out by considering two operational periods: the first one was based on literature indications (3.2 m(2)/PE in the VSSF unit) and the second one assumed higher hydraulic and organic loads (1.3 m(2)/PE in the VSSF unit). The removal efficiency in the hybrid CW system decreased slightly from 94 to 88% for COD removal and from 78 to 75% for total N removal, even after applying a double hydraulic (from 55 to 123 L m(-2) d(-1)) and organic load (from 37 to 87 g COD m(-2) d(-1) and from 4.4 to 10.3 g TKN m(-2) d(-1)). The results showed that in the summer period the application of high loads did not affect the efficiency of the hybrid CW plant significantly, suggesting that it is possible to refer the CW design to the resident population only, with subsequent considerable savings in superficial area.  相似文献   

3.
水平潜流人工湿地脱氮除磷研究进展   总被引:3,自引:0,他引:3  
总结了水平潜流人工湿地的脱氮除磷机理,分析了进水水质、植物、基质、温度和水力停留时间这5种影响处理效果的主要因素,从不同角度论述了提高脱氮除磷效果所采取的措施,并探讨了水平潜流人工湿地存在的局限性和发展趋势。  相似文献   

4.
This paper describes a two-year performance evaluation of four different constructed wetland (CW) treatment systems designed by IRIDRA Srl, located in central Italy. All four CW systems were established to treat wastewater effluent from different tourist activities: (1) one single-stage CW for secondary treatment of domestic wastewater (30 p.e.) at a holiday farm site; (2) a hybrid compact system consisting of two stages, a horizontal flow (HF) system followed by a vertical flow (VF) system for the secondary treatment of effluent from a 140 p.e. tourist resort; (3) a single-stage vertical flow (VF) CW for a 100 p.e. mountain shelter; and (4) a pair of single-stage, HF CWs for the secondary treatment of segregated grey and black water produced by an 80 p.e. camping site. These tourism facilities are located in remote areas and share some common characteristics concerning their water management: they have high variability of water consumption and wastewater flow, depending on the season, weather and weekly regularities; they have no connection to a public sewer and most sites are located in a sensitive environment. Total suspended solids (TSS), chemical oxygen demand (COD), biochemical oxygen demand (BOD5), ammonium (N-NH4+), nitrate (N-NOx), total nitrogen (Ntot), total phosphorus (Ptot), total coliform (TC), faecal coliform (FC), E. coli removal efficiencies for all four CW systems are presented. The results from this study demonstrate the potential of CWs as a suitable technology for treating wastewater from tourism facilities in remote areas. A very efficient COD reduction (83-95%) and pathogen elimination (3-5 logs) have been achieved. Furthermore, the CWs are easily maintained, robust (not sensitive to peak flows), constructed with local materials, and operate with relatively low cost.  相似文献   

5.
研究了以葡萄糖和乙酸钠为碳源的条件下,垂直流人工湿地对四环素(TC)、土霉素(OTC)和金霉素(CTC)等3种四环素类抗生素(TCs)的去除效果。结果表明,在试验条件下,乙酸钠与葡萄糖两种碳源均能有效促进人工湿地系统对3种TCs的去除;在相同碳源条件下COD质量浓度越高,TCs的去除率越高,当COD质量浓度大于400mg/L时,对3种TCs的去除率均达到90%以上;垂直流人工湿地对TCs的去除过程包括2个阶段:前2 h为湿地基质吸附作用下的快速去除阶段,2~24 h为缓慢去除阶段。乙酸钠与葡萄糖两种碳源对TCs去除率的提高,主要发生在2h之后的第二个阶段,分析认为发生了微生物共代谢作用,促进了湿地系统对基质吸附富集之后的TCs的进一步降解。  相似文献   

6.
Constructed wetlands (CWs) have proved to be a highly effective measure to reduce the ecological impact of combined sewer overflows (CSOs) on receiving waters. Due to the stochastic nature of the loading regime and the multitude of environmental influences, assessment of the performance of such plants requires detailed mathematical modelling. A multi-component reactive transport module (CW2D) was applied to simulate the flow, transport and degradation processes occurring in a CW for CSO treatment. CW2D was originally developed to simulate the treatment of municipal wastewater in subsurface flow CWs. Loading and operational conditions in CSO treatment differ fundamentally from the conditions occurring for wastewater treatment. Despite these differences, first results from the simulation of lab-scale experiments show, that the model is generally applicable to this type of plant. Modelling of adsorption, degradation processes, and influent fractionation, however, require further research.  相似文献   

7.
The ability of several mesocosm-scale and full-scale constructed wetlands (CWs) to remove pharmaceuticals and personal care products (PPCPs) from urban wastewater was assessed. The results of three previous works were considered as a whole to find common patterns in PPCP removal. The experiment took place outdoors under winter and summer conditions. The mesocosm-scale CWs differed in some design parameters, namely the presence of plants, the vegetal species chosen (Typha angustifolia versus Phragmites australis), the flow configuration (surface flow versus subsurface flow), the primary treatment (sedimentation tank versus HUSB), the feeding regime (batch flow versus continuous saturation) and the presence of gravel bed. The full-scale CWs consisted of a combination of various subsystems (ponds, surface flow CWs and subsurface flow CWs). The studied PPCPs were ketoprofen, naproxen, ibuprofen, diclofenac, salicylic acid, carbamazepine, caffeine, methyl dihydrojasmonate, galaxolide and tonalide. The performance of the evaluated treatment systems was compound dependent and varied as a function of the CW-configuration. In addition, PPCP removal efficiencies were lower during winter. The presence of plants favoured naproxen, ibuprofen, diclofenac, salicylic acid, caffeine, methyl dihydrojasmonate, galaxolide and tonalide removal. Significant positive correlations were observed between the removal of most PPCPs and temperature or redox potential. Accordingly, microbiological pathways appear to be the most likely degradation route for the target PPCPs in the CWs studied.  相似文献   

8.
A pilot-scale fluidised pellet bed (FPB) bioreactor, which combines chemical coagulation, biological degradation, particle pelletisation and separation in one unit, was applied for onsite wastewater treatment and reuse. As a result of rational use of inorganic coagulant and organic polymer and moderate mechanical agitation, spherical particles were generated in the upflow column and a well-fluidised bed was formed. With a continuous supply of dissolved oxygen through a recycling loop, an aerobic condition was kept in the bottom section of the FPB column. Under such conditions the pellets in the FPB column showed the following characteristics: (1) compact structure and high density; (2) rich in microorganisms; and (3) high MLSS and MLVSS concentrations. Therefore, the FPB bioreactor achieved more than 90% removal of SS, COD, BOD and TP from raw domestic wastewater within a total hydraulic retention time (HRT) of only about 30 minutes. It also showed nitrification and denitrification ability and the TN removal could be about 50% as the recycling ratio was increased to 1:1. The treated water quality is generally competitive with the secondary effluent from a conventional activated sludge process. With these advantages the FPB bioreactor is recommendable as a compact system for onsite wastewater treatment and reuse.  相似文献   

9.
In the new version of the World Health Organization (WHO), water reuse guidelines helminth ova are considered one of the main target pollutants to be removed from wastewater reuse for agriculture and aquaculture purposes. In spite of this, along with the fact that helminth ova have been considered the main health risk to wastewater reuse for agriculture for at least 20 years, relatively little research has been done to control helminth ova in the wastewater treatment field. This paper addresses (1) characteristics of helminth ova and differences with microorganisms; (2) the most frequent helminth ova genus found in wastewater; (3) helminth ova content in developed and developing countries wastewater; (4) reasons why conventional disinfection methods cannot be applied; (5) main removal mechanisms; and (6) processes that in practice have effectively removed or inactivated helminth ova.  相似文献   

10.
In Mediterranean countries, water shortage is becoming a problem of high concern affecting the local economy, mostly based on agriculture. The problem is not only the scarcity of water in terms of average per capita, but the high cost to make water available at the right place, at the right time with the required quality. In these cases, an integrated approach for water resources management including wastewater is required. The management should also include treated wastewater (TWW) reclamation and reuse, especially for agricultural irrigation. In Italy, TWW reuse is regulated by a quite restrictive approach (Ministry Decree, M.D. 185/03), especially for some chemical compounds and microbiological parameters. The aim of the paper is the evaluation of TWW reuse potential in Sicily. A Geographic Information System (GIS) was built at regional level to quantify and locate the available TWW volumes. In particular, the characteristics of wastewater treatment plants (WWTPs) were integrated, through the GIS, with data on irrigation district areas. Moreover, in order to evaluate the Italian approach for reuse practice in agriculture, the water quality of different TWW effluents was analysed on the basis of both the Italian standards and the WHO guidelines.  相似文献   

11.
A new type of hybrid constructed wetland (CW), consisting of both vertical-baffled flow wetland (VBFW) and horizontal subsurface flow wetland (HSFW), has been deployed in Southern China to naturally accelerate the removal of organic matter and nitrogen. The hybrid CW system is characterised by a combination of continuous baffled flow vertical wetland and 'S' pattern horizontal subsurface flow wetland with natural aeration ditches to increase the concentration of dissolved oxygen in the HSFW bed. An internal circulatory system from the HSFW effluent back to the VBFW may optionally be operated to enhance the biological denitrification effect. Cyperus alternifolius is the main macrophyte in the wetland bed. The performance of the hybrid CW was studied with a pilot-scale system and three full-scale systems for municipal sewage treatment in Southern China. The results suggest that this new hybrid CW can achieve removal efficiencies of chemical oxygen demand, suspended solids, ammonia nitrogen, total nitrogen, and total phosphorus of better than 83.6, 95.0, 71.7, 64.5 and 68.1% respectively, with a specific wetland bed area of 0.70-0.93 m(2) PE(-1). The mean effluent concentrations of these parameters would meet the regulatory discharge limits for wastewater treatment systems (GB18918, 2002) and reuse in the context of agricultural irrigation solutions in China.  相似文献   

12.
生物过滤氧化反应器处理生活污水中试研究   总被引:3,自引:0,他引:3  
以生活污水为处理对象 ,研究了生物过滤氧化反应器 (BIOFOR)在高滤速、高负荷、小的气水比情况下 ,用非常短的水力停留时间 (6 0~ 80min) ,取得了很好的出水水质的机理 ,主要水质指标 (COD、BOD、SS、氨氮 )可达到国家《污水综合排放标准》或《生活杂用水水质标准》。同时探讨了滤速及容积负荷对出水水质的影响 ,分析了主要污染物的去除规律。  相似文献   

13.
In tropical regions, where most of the developing countries are located, septic tanks and other onsite sanitation systems are the predominant form of storage and pre-treatment of excreta and wastewater, generating septage and other types of sludges. The septage is disposed of untreated, mainly due to lack of affordable treatment options. This study presents lessons that have been learned from the operation of pilotscale constructed wetlands (CWs) for septage treatment since 1997. The experiments have been conducted by using three CW units planted with narrow-leave cattails (Typha augustifolia) and operating in a vertical-flow mode. Based on the experimental results, it can be suggested that the optimum solids loading rate be 250 kg TS/m2 yr and 6-day percolate impoundment. At these operational conditions, the removal efficiencies of CW units treating septage at the range of 80-96% for COD, TS and TKN were achieved. The biosolid accumulated on the CW units to a depth of 80 cm has never been removed during 7 years of operation, but bed permeability remained unimpaired. The biosolid contains viable helminth eggs below critical limit of sludge quality standards for agricultural use. Subject to local conditions, the suggested operational criteria should be reassessed at the full-scale implementation.  相似文献   

14.
This paper presents the purification performance of 20 wastewater treatment plants with vertical reed bed filters (Macrophyltres), built between 1998 and 2003 by SAS Voisin, for communities of between 150 and 1400 PE. The first stage vertical reed bed (directly fed with raw wastewater by intermittent feeding) achieved high removal of SS, BOD and COD (mean respectively 96%, 98%, 92%). The second stage permitted compliance easily with effluent standards (SS < 15 mg/l, BOD < 15 mg/l, COD < 90 mg/l and mean TKN < 10 mg/l). Performance was not significantly influenced by variations of organic and hydraulic load, nor by seasonal variations. Rigorous operation and maintenance were required to obtain optimal performances. Another application of vertical reed beds is the treatment of septage (sludge from individual septic tanks). The results obtained on two sites operating for 2 and 3 years are presented. The first site achieved complete treatment of septage (solid and liquid fraction), the second permitted a pre-treatment for co-treatment of percolate with wastewater.  相似文献   

15.
The aim of this work is to analyse the biological performances of two immersed membranes bioreactors focusing on the biomass adaptation to complex substrate degradation and the performance in term of permeate quality. Two influents were selected: a synthetic complex influent (acetate/Viandox, MBR1) and a real seafood processing wastewater (surimi product, MBR2). The MBR systems were operated for long periods without any sludge extraction except for sampling. Organic matter removal, sludge production and quality of the treated wastewater were analysed and studied. COD removal efficiencies after a period of biomass adaptation were higher than 97% and 95% for the synthetic and real wastewater respectively. In both cases, the COD of the treated wastewater was lower than 50 mg.L(-1). In spite of salt concentration in the real wastewater a biomass adaptation process occurs. In the overall operational period, a 0.058 gCOD P.gCOD T(-1) and a 0.12 gCOD P.gCOD T(-1) observed sludge yields were obtained for the MBR1 and MBR2 respectively. These values are approximately 5 to 10 times lower than those measured in conventional activated sludge process. These results showed that the presence of particular and some of non-easily degradable compounds in the influent of MBR2 didn't limit the performance of MBR in term of COD removal achieved. The results have also confirmed the excellent permeate quality for water reuse from MBRs systems.  相似文献   

16.
Petroleum production wastewater is highly saline and contains large amounts of Ca, Mg, sulphides and hydrocarbons. The reuse of this wastewater in the secondary oil recovery can provide pollution prevention and water conservation benefits. Injection of water to the oil deposits is a frequently used method for secondary oil recovery. This operation is performed at high pressures and temperatures, because of which a suitable water quality is required to avoid deposit formation, scaling and clogging effects. The objective of this study was to select the best treatment system for the oil production wastewater, generated in one of the Mexican oil extraction facilities, for the implementation of this kind of reuse by injecting the treated water to sand formations with 12-15% porosity. A complete characterization of the petroleum production wastewater was done. Based on laboratory tests, three basic treatment options were suggested and evaluated in a pilot plant. The most suitable treatment was determined by injecting the different treated waters in samples of the real formations. The selected system consists in softening, followed by oxidation, decarbonation and filtration. This train allowed 99.8% hardness removal, a complete S(2-) removal, as well as 99% TSS, 78% TOC, 98% Sr, 86% Ba, 51% Si and 17% Fe removals.  相似文献   

17.
Treatment of toilet wastewater for reuse in a membrane bioreactor.   总被引:1,自引:0,他引:1  
Toilet wastewater is treated and reused on site at Europe's highest membrane bioreactor (MBR), located in a cable car mountain station in the ski resort of Zermatt. Negative impacts on the sensitive mountain environment are minimised by reusing close to 100% of the treated wastewater for toilet flushing. Besides 100% nitrogen removal, 80% of phosphorus was also eliminated. This paper presents operational results, optimisations of sludge management, decoloration and long-term maintenance of biomass in the very low-loaded summer season. From a global view the experiences and results of the project are of great importance, proposing a solution to a problem existing 100-fold in the Alps as well as in arid regions all over the world: reducing water consumption for sanitation by reuse.  相似文献   

18.
An on-site study on the operational performance of a combined eco-system of ponds and SF constructed wetland for municipal wastewater treatment and reclamation/reuse in Donging City, Shandong, China was carried out from January 2001 through October 2003. The removal efficiencies for various main parameters were: TSS 84.8 +/- 7.3%, BOD5 87.2 +/- 5.3%, CODCr 70.2 +/- 18.6%, TP 52.3 +/- 23.1%, and NH(3)-N 54.8 +/- 23.9% with effluent concentration of TSS 9.12 +/- 5.12 mg/l, BOD5 6.44 +/- 4.58 mg/l, CODCr, 42.8 +/- 6.7 mg/l, TP 0.94 +/- 0.27 mg/l and NH(3)-N 7.95 +/- 2.36 mg/l. In addition, the removal efficiencies for faecal coliforms and total bacteria were > 99.97% and > 99.998% respectively, which well meet Chinese National standards for effluent quality of municipal wastewater treatment plants. The composition of TSS was closely related to CODCr and BOD5 variations, and nitrification-denitrification is the major mechanism of nitrogen removal both in ponds and in wetlands. In addition, sedimentation also played an important role in the removal of TSS, nitrogen, phosphorus and BOD5. The removal efficiencies of various parameters, the number of species and biomass of biological community in the system increased gradually with the ecological maturation.  相似文献   

19.
Several different types of constructed wetland systems are being used as decentralized treatment systems including surface-flow, subsurface-flow, vertical-flow, and hybrid systems. Archetypical wetland systems have design strengths and weaknesses, and therefore it should be possible to design combined (integrated) systems to optimize a number of important treatment processes. This study provides comparative efficacy data for two integrated wetland treatment systems (IWTS) designed to enhance treatment of medium strength wastewater generated from a pilot-scale intensive fish farm. Results from the twenty eight months study included consistently high removal of COD (84% +) and ammonia nitrogen (93%) in both systems. Initially, phosphorus removal was also high (>90%) in both systems, but removal efficacy declined significantly over time. Nitrate removal was significantly better in the system that provided sequential aerobic and anoxic environments. Short hydraulic retention times coupled with sustained removal of COD and ammonia indicate that the ReCip components could be a least-cost wastewater treatment technology in the decentralized market sector.  相似文献   

20.
用氧化塘—浮石床湿地系统处理暖寒季低污染河水   总被引:1,自引:0,他引:1       下载免费PDF全文
在滇池流域构建氧化塘-浮石床湿地复合系统对暖季与寒季的城市低污染河水开展了净化效能研究。结果表明:该系统可通过小幅调节流量来有效净化暖季与寒季低污染河水。塘与湿地的水力负荷分别为0.22、0.37m3/(m2.d)时系统对暖季低污染河水具有较高的处理效率,各污染物的平均去除率分别为CODCr75%、TP 93%、TN 64%、NH4+-N 87%。塘与湿地的水力负荷分别为0.17、0.29 m3/(m2.d)时系统对寒季低污染河水具有较优的处理效果:各污染物的平均去除率分别为CODCr72%、TP 89%、TN 53%、NH4+-N 73%。系统出水均符合GB18918-2002的一级A排放标准。系统在暖季对低污染河水中污染物的去除速率明显高于寒季。  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司    京ICP备09084417号-23

京公网安备 11010802026262号