首页 | 官方网站   微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
复合人工湿地系统对生活污水的净化效果   总被引:1,自引:0,他引:1  
将垂直流人工湿地与水平流人工湿地组成复合人工湿地系统,研究了此复合系统对化粪池出水的净化效果。结果表明,当水平流人工湿地的水力停留时间为3d天时,复合系统对COD、BOD5、TP的去除率分别达到73%、66%、87%,并通过垂直流湿地的硝化作用及水平流湿地的反硝化作用,复合系统对TN的去除率达到40%以上。  相似文献   

2.
对A2N连续流工艺进行改进,在后曝气池中填加生物膜填料,以生活污水为处理对象,考察了后曝气池水力停留时间(HRT)对后曝气池内同步硝化反硝化(SND)以及对改进后的A2N工艺除磷脱氮性能的影响.后曝气池HRT为1.3h时,总磷(TP)平均去除率为90%,总氮(TN)平均去除率为75%,但平均出水氨氮浓度较高(为8.6 mg.L-1),后曝气池内基本未发现SND现象.后曝气池HRT为2.3h时,TN平均去除率达到80%,TP平均去除率高达95%,出水平均氨氮浓度较低(2.2 mg.L-1),后曝气池内同步硝化反硝化去除的TN量为2.42 mg.L-1.后曝气池HRT为4h、6h时,工艺TP平均去除率逐渐下降至60%,由于可利用的COD值较低,同步硝化反硝化去除的TN并未随HRT延长而有明显增长,TN去除率也逐渐降至接近60%.试验证明在后曝气池内填加生物膜并合理调控HRT,可强化工艺的脱氮除磷效果.  相似文献   

3.
潜流水平湿地对农业灌溉径流氮磷的去除   总被引:5,自引:0,他引:5       下载免费PDF全文
构建了潜流水平芦苇湿地,对农业灌溉径流(TN约为7mg/L,TP约为0.5mg/L)中氮磷进行了为期1年的去除研究.在水力停留时间(HRT)为2,4,6d时,TP和TN的去除率均大于87%和68%.湿地对TN、NH4+-N和TP的去除受HRT的影响较大(P<0.05),对PO43--P的去除受HRT的影响较小.在不同HRT情况下,NH4+-N、NO2--N、NO3--N和PO43--P的去除率均高于93%,出水浓度一般均小于0.04mg/L.且出水中的TP和TN主要为有机态,存在一个TP和TN背景浓度.TN去除率与负荷之间具有很好的相关性(R2=0.9968),但是TP去除率与负荷之间相关性较差(R2=0.5987).以HRT为2d计算,1m2的芦苇床处理该农业灌溉径流的能力为0.1m3/d,出水TN和TP浓度可控制在0.50mg/L和0.154mg/L以下.  相似文献   

4.
不同基质垂直流人工湿地对猪场污水季节性处理效果的研究   总被引:16,自引:0,他引:16  
研究了3套不同基质垂直流人工湿地小试装置在不同季节处理猪场污水的运行效果.结果表明,垂直流人工湿地对有机污染物的去除效果随季节变化差异不明显,对有机物降解情况可用一级降解模型模拟;传统型湿地系统NH4 -N去除率在各季节稳定在52%,而沸石和沸石-煤渣型系统冬季NH4 -N去除效率分别从秋季的89.8%和93.4%下降至冬季的64.2%和73.5%,春、夏季回升至80%左右.冬季湿地系统中生物硝化与反硝化作用的减弱影响了垂直流人工湿地系统TN的去除;3套不同基质系统中,沸石-煤渣型系统各高度层硝化强度均为最高,沸石型和沸石-煤渣型系统的反硝化强度明显高于传统型系统,与实际运行过程TN去除率变化相吻合.采用沸石作为基质有利于系统的反硝化进程和TN的去除.垂直流系统对TP去除率随季节性变化波动不显著,但随着垂直流人工湿地系统的运行,基质层对TP的吸附逐渐饱和,去除效率明显下降.  相似文献   

5.
内循环对A2/O-曝气生物滤池工艺脱氮除磷特性影响   总被引:8,自引:6,他引:2  
在原水温度为15℃和C/N为4.9的条件下,以实际生活污水为研究对象,重点考察了内回流比为100%、200%、300%和400%时小试规模A2/O-曝气生物滤池工艺脱氮除磷特性.结果表明,该生化系统可实现有机物、氮和磷的同步深度去除.在总HRT为8.0 h、SRT为15 d、污泥回流比为100%和MLSS为4.0 g·...  相似文献   

6.
城市污水混合垃圾渗滤液脱氮试验研究   总被引:1,自引:0,他引:1  
采用倒置A2/O工艺处理垃圾渗滤液与城市污水混合后的污水脱氮。正交试验得到,水力停留时间是影响混合污水脱氮和有机物去除的控制因素;理论最优运行参数是HRT为9 h、ρ(DO)为2 mg/L、R为80%、r为200%,该工况下COD、NH3-N和TN的平均去除率分别为77.4%、97.2%和62.4%,出水浓度可稳定地达到GB18918-2002《城镇污水处理厂污染物排放标准》一级A标准。  相似文献   

7.
高效藻类塘对农村生活污水的处理及氮的迁移转化   总被引:3,自引:1,他引:2  
研究了高效藻类塘系统处理高氮农村污水氮的去除及其迁移转化规律.高效藻类塘和水生高等植物塘水力停留时间分别为8 d和4 d,进水总氮和氩氮分别为17.13-133.2 mg/L和1.85~108.3 mg/L,两级高效藻类塘对总氮和氨氮的全年平均去除效率分别为29.4%和91.6%,季节处理效率排序为夏季>秋季>春季>冬季.高效藻类塘中氨氮的降解和转化途径依次为硝化作用、藻类同化吸收及其他途径、氨氮挥发;硝化作用占氨氮总转化量的50%以上;高效藻类塘内可以发生氨氮沉淀,但可忽略不计.总氮的去除以藻类同化形成颗粒有机氮经分离后得以去除为主,氨氮挥发较少.可采用藻类塘出水回流至化粪池或改进水生高等植物塘构造强化反硝化.提高系统的整体脱氮效果.  相似文献   

8.
硝化液回流比对A2/O-BCO工艺反硝化除磷特性的影响   总被引:1,自引:0,他引:1       下载免费PDF全文
以低C/N城市生活污水为处理对象,重点考察了硝化液回流比对A2/O - BCO(生物接触氧化)工艺脱氮除磷特性的影响.在A2/O反应池水力停留时间(HRT)为8h,污泥回流比为100% 条件下,将硝化液回流比分别设定为100%、200%、300%和400%进行试验.结果表明, 系统在A2/O中实现了反硝化除磷,具有很好的同步氮磷的去除效果,出水COD浓度均在50mg/L以下.上述不同硝化液回流比下总氮(TN)去除率分别为48.8%、66.5%、75.6%和62.5%,总磷(TP)去除率分别为86.0%、90.3%、91.0%和95.0%.在硝化液回流比为300%时,系统平均出水TN和TP浓度分别为14.96mg/L和0.49mg/L.系统反硝化除磷量随着硝化液回流比的增大略有增加,在硝化液回流比为400%时,反硝化除磷量高达磷总去除量的98%.  相似文献   

9.
页岩-钢渣组合填料湿地强化脱氮除磷研究   总被引:10,自引:3,他引:7  
谭洪新  周琪  杨殿海 《环境科学》2006,27(11):2182-2187
以城市污水A/O工艺出水为处理对象,运用页岩和钢渣物化除磷、调控进水碳氮比和氮素氧化性等技术手段,在中试规模上研究了页岩和钢渣组合填料湿地的脱氮除磷效能及影响因素.结果表明,当COD面积负荷率、TN面积负荷率、TP面积负荷率、HRT(水力停留时间)分别为6.5~20.7 g·(m2·d)-1、2.57~8.22 g·(m2·d)-1、0.41~1.32 g·(m2·d)-1、0.5~1.6d时,①氨氮、亚硝态氮和硝态氮的去除率分别为85.8%、56.3%和18.6%,TN去除率为58.0%,TN面积负荷去除率为3.58g·(m2·d)-1,TN反应动力学常数为0.31 m·d-1,TN面积负荷去除率随进水TN负荷的增加而线性增加.②TP去除率为90.4%,TP面积负荷去除率为0.89 g·(m2·d)-1,TP反应动力学常数为0.86 m.d-1,TP面积负荷去除率随进水TP负荷的增加而线性增加.③水温、HRT、氮素组分、C/N等因素对湿地系统的脱氮除磷效率有显著影响.TN面积负荷去除率随HRT、COD/TN值的增加而幂函数增加.TN面积负荷去除率随水温(、NO2--N+NO3--N)/TN值的增加而呈指数函数增加.  相似文献   

10.
添加碳源对潜流+表面流组合湿地脱氮除磷的影响   总被引:2,自引:0,他引:2  
谭洪新  刘艳红  周琪  杨殿海 《环境科学》2007,28(6):1209-1215
采用向ANOXIC-OXIC(A/O)工艺出水中添加城市污水的方法,在中试规模上研究了外加碳源对潜流+表面流组合湿地脱氮除磷的影响.结果表明,直接处理A/O工艺出水时(工况Ⅰ),湿地进水COD/TN仅为1.00,(NO-2+NO-3)/TN为0.48,COD、TN和TP的面积负荷去除率分别为1.82、1.59、0.14 g·(m2·d)-1.A/O工艺出水中添加少量城市污水后(工况Ⅱ),湿地进水COD/TN为3.55,(NO-2+NO-3)/TN为0.44,COD、TN和TP的面积负荷去除率分别为19.03、5.42、0.29 g·(m2·d)-1.工况Ⅱ的TN和TP面积负荷去除率分别比工况Ⅰ提高了3.4倍和2.1倍.HRT、水温、(NO-2+NO-3)/TN和COD/TN对湿地脱氮除磷效能有显著影响,在HRT为0.5~1.0d, COD、TN和TP的面积负荷率分别为3.8~38.7、5.07~13.08、0.57~1.92 g·(m2·d)-1时, TN面积负荷去除率随HRT增加而指数下降,随水温和(NO-2+NO-3)/TN的升高而线性增加,随COD/TN的增加呈幂函数增加.TP面积负荷去除率随COD/TN的增加呈幂函数增加.  相似文献   

11.
淹没式MBR处理啤酒废水的净化效能   总被引:2,自引:0,他引:2  
在投加营养物质 ,保持COD∶TN∶TP =10 0∶5∶1的条件下 ,淹没式MBR对合成啤酒废水中的COD、NH 4 N有着较好的去除效果 ,系统稳定时COD与NH 4 N的平均去除率均在 90 %以上 ,而且MBR工艺对进水有机负荷的冲击具有较强的短时适应能力 ,当COD污泥负荷率由 0 2 7g/ (g·d)突然增加至 0 5 4 g/ (g·d)时 ,出水COD浓度未出现明显的波动 .通过GC/MS分析得出 ,膜组件出水中剩余的有机物主要为高分子量的烷烃类 ,膜组件对于保证系统的最终出水水质起到了关键的作用 .当反应器中的污泥处于增长期时 ,在生物同化作用与同步硝化 反硝化共同作用下 ,使得TN具有 4 0 %左右的去除效果 ,当污泥浓度处于稳定期时 ,TN去除率下降为 30 %左右 ,主要是同步硝化 反硝化的结果 .当污泥处于增长期时 ,通过生物同化作用对TP具有一定的去除效果 ,而当污泥浓度稳定后 ,对TP基本没有去除效果 ,甚至有时出现负去除率现象  相似文献   

12.
Algal biofilmtechnology is a new and advanced wastewater treatment method. Experimental study on removing nitrogen and phosphorus from simulated wastewater using algal biofilm under the continuous light of 3500 Lux in the batch and continuous systems was carried out in this paper to assess the performance of algal biofilm in removing nutrients. The results showed that the effect of removing nitrogen and phosphorus by algal biofilm was remarkable in the batch system. The removal efficiencies of total phosphorus (TP), total nitrogen (TN), ammonia-nitrogen (NH3-N), and chemical oxygen demand (COD) reached 98.17%, 86.58%, 91.88%, and 97.11%, respectively. In the continuous system, hydraulic retention time (HRT) of 4 days was adopted; the effects of removing TP, TN, NH3-N, and COD by algal biofilm were very stable. During a run of 24 days, the removal efficiencies of TP, TN, NH3-N, and COD reached 95.38%, 83.93%, 82.38%, and 92.31%, respectively. This study demonstrates the feasibility of removing nitrogen and phosphorus from simulated wastewater using algal biofilm.  相似文献   

13.
A membrane aerated biofilm reactor is a promising technology for wastewater treatment. In this study, a carbon-membrane aerated biofilm reactor (CMABR) has been developed, to remove carbon organics and nitrogen simultaneously from one reactor. The results showed that CMABR has a high chemical oxygen demand (COD) and nitrogen removal efficiency, as it is operated with a hydraulic retention time (HRT) of 20 h, and it also showed a perfect performance, even if the HRT was shortened to 12 h. In this period, the removal efficiencies of COD, ammonia nitrogen (NH4^+-N), and total nitrogen (TN) reached 86%, 94%, and 84%, respectively. However, the removal efficiencies of NH4^+-N and TN declined rapidly as the HRT was shortened to 8 h. This is because of the excessive growth of biomass on the nonwoven fiber and very high organic loading rate. The fluorescence in situ hybridization (FISH) analysis indicated that the ammonia oxidizing bacteria (AOB) were mainly distributed in the inner layer of the biofilm. The coexistence of AOB and eubacteria in one biofilm can enhance the simultaneous removal of COD and nitrogen.  相似文献   

14.
为优化多级A/O(缺氧/好氧)+BAF(曝气生物滤池)系统处理低C/N生活污水强化脱氮除磷的关键运行条件,采用单因素试验分别研究了HRT(水力停留时间)、三点进水比例及BAF填料高度对系统主要污染物去除的影响,并以此为对照,通过BBD二阶模型中心复核设计多因素试验,采用响应面法分析上述三因素对TN、TP去除的交互影响,得出了优化运行条件与TN、TP去除率的模型预测值,在该条件下运行系统,验证了TN、TP去除率实际值与预测值的相对误差. 结果表明:①单因素试验表明,当HRT为9 h、进水比例为5∶3∶2、填料高度为1 800 mm时,多级A/O+BAF系统中主要污染物的去除效果最好. ②响应面分析得出,三因素对TN、TP的去除交互影响显著;模型拟合回归方程得出,优化运行条件为HRT 8.5 h、进水比例5∶3∶2、填料高度1 600 mm时,TN、TP去除率预测值分别为84.88%、94.37%. ③验证结果表明,进水ρ(TN)、ρ(TP)平均值分别为68.8、5.4 mg/L,出水ρ(TN)、ρ(TP)平均值分别为10.61、0.32 mg/L,TN、TP实际去除率分别为84.15%、94.01%,与TN、TP去除率预测值相比,相对误差仅分别为0.86%、0.38%. 研究显示,应用响应面法建立模型优化多级A/O+BAF工艺处理生活污水的方法可靠,实现了对氮磷的强化去除.   相似文献   

15.
Vertical flow constructed wetlands is a typical ecological sanitation system for sewage treatment.The removal rates COD,BOD5,SS,TN and TP were 60%,80%,74%,49%and 79%,respectively,when septic tank effluent was treated by vertical flow filter.So the concentration of COD and BOD5 in the treated effluent could meet the quality standard for irrigation water.After that the treated effluent was used for hydroponic cultivation of water spinach and romaine lettuce,the removal efficiencies of the whole system for COD, BOD5,SS, TN and Tpwere 71.4%,97.5%,96.9%,86.3%,and 87.4%,respectively.And it could meet the integrated wastewater discharge standard for secondary biological treatment plant.It was found that using treated effluent for hydroponic cultivation of vegetables could reduce the nitrate content in vegetables.The removal rates for total bacteria and coliform index by using vertical flow bed system with cinder substrate were 80%-90% and 85%-96%,respectively.  相似文献   

16.
以磁混凝预处理后的生活污水为处理对象,构建了部分亚硝化-厌氧氨氧化分体式反应器,通过曝气调控与生物强化促进部分亚硝化反应的稳定进行,并耦合厌氧氨氧化反应进行深度脱氮.近100d的运行结果表明,在生物强化和间歇曝气的控制条件下,亚硝酸盐积累率达到了89.93%;提高亚硝化反应器中曝气阶段溶解氧浓度(从0.6~0.8mg/L升高至1.0~1.2mg/L)有利于氨氮与总氮去除.该系统最高能够去除95.45%的氨氮和86.28%的总氮,实现了稳定、高效脱氮;磁混凝预处理后的生活污水在亚硝化反应器中,间歇曝气条件促进了残留的溶解性有机物为反硝化提供碳源,COD总去除率达到64.65%~74.42%,并且亚硝化反应器出水与系统最终出水的有机物组分相似,主要为难降解有机物.  相似文献   

17.
以磁混凝预处理后的生活污水为处理对象,构建了部分亚硝化-厌氧氨氧化分体式反应器,通过曝气调控与生物强化促进部分亚硝化反应的稳定进行,并耦合厌氧氨氧化反应进行深度脱氮.近100d的运行结果表明,在生物强化和间歇曝气的控制条件下,亚硝酸盐积累率达到了89.93%;提高亚硝化反应器中曝气阶段溶解氧浓度(从0.6~0.8mg/L升高至1.0~1.2mg/L)有利于氨氮与总氮去除.该系统最高能够去除95.45%的氨氮和86.28%的总氮,实现了稳定、高效脱氮;磁混凝预处理后的生活污水在亚硝化反应器中,间歇曝气条件促进了残留的溶解性有机物为反硝化提供碳源,COD总去除率达到64.65%~74.42%,并且亚硝化反应器出水与系统最终出水的有机物组分相似,主要为难降解有机物.  相似文献   

18.
焦化废水厌氧氨氧化生物脱氮的研究   总被引:4,自引:1,他引:3       下载免费PDF全文
采用厌氧氨氧化(ANAMMOX)工艺处理焦化废水,在厌氧34℃、pH值7.5~8.5,HRT为33h的条件下,经过115d成功启动厌氧氨氧化反应器.当进水NH4+-N、NO2--N浓度分别为80、90mg/L左右时, TN负荷可达160mg/(L·d),系统NH4+-N和NO2--N的去除率最高分别达86%和98%,TN去除率可达75%. GC-MS分析结果表明,酚类是焦化废水中较易被生物利用的有机物,ANAMMOX过程对好氧短程硝化工艺出水残余低浓度酚类有机物有进一步去除作用.  相似文献   

19.
城市污水三污泥系统自养脱氮与强化生物除磷   总被引:2,自引:2,他引:0  
易鹏  张树军  甘一萍  常江  彭永臻  曹相生 《环境科学》2010,31(10):2390-2397
采用"A/O除磷+半亚硝化-厌氧氨氧化自养脱氮"三污泥系统,实现了城市污水营养物经济高效去除.结果表明,在水力停留时间(HRT)为3.6h条件下,A/O除磷系统出水总磷(TP)≤0.5mg/L;在常温、DO0.2mg/L和HRT=4.6h条件下,半亚硝化系统实现了亚硝氮累积率为75%~96%的半亚硝化;在温度为27~30℃和HRT=1.4h条件下,厌氧氨氧化(ANAMMOX)系统出水总氮(TN)≤8mg/L,最低值为1.6mg/L,TN去除负荷达到0.57kg/(m3·d).三污泥系统中聚磷菌、氨氧化菌和ANAMMOX菌均在各自适宜的环境条件下生存,优化了污泥种群,提高了各工艺单元的处理效率.城市污水自养脱氮系统理论上可以减少62.5%的供氧量,节省100%反硝化碳源,同时降低了污泥产量,大大减少了CO2的排放.与传统的生物脱氮除磷工艺相比,三污泥系统具有节能降耗减排上的巨大优势和潜力,也有利于实现水资源的循环利用和可持续发展.  相似文献   

20.
为强化CMICAO(多点交替进水阶式A2/O)工艺的脱氮除磷性能,通过调整进水C/N〔ρ(CODCr)/ρ(TN)〕、进水端厌氧池和缺氧池的进水流量比对CMICAO工艺参数进行优化,考察其对氮、磷去除的影响. 结果表明:试验条件下,C/N的提高可增强SND(同步硝化反硝化)作用,氮的去除效果也随之提高,C/N≥7时,前好氧池同步硝化反硝化率达到61%,出水ρ(TN)≤9.0 mg/L;在相同工况下,较低的C/N下反硝化除磷现象更明显. 综合考虑,C/N在5~7范围内,可取得较好的整体脱氮除磷效果. 优化工艺进水碳源分配可提高碳源利用效率,氮、磷的去除效果受进水流量比的影响较大,当厌氧池和缺氧池进水流量比为2.0时,可强化缺氧池的反硝化除磷作用,TN和TP去除率分别为75%和92%,出水ρ(CODCr)、ρ(NH+4-N)、ρ(TN)和ρ(TP)分别为28.7、1.9、9.2和0.27 mg/L,通过优化实现了CMICAO工艺对氮、磷去除的强化.   相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司    京ICP备09084417号-23

京公网安备 11010802026262号