首页 | 官方网站   微博 | 高级检索  
相似文献
 共查询到18条相似文献,搜索用时 531 毫秒
1.
ICSTD反应器处理污泥的启动试验研究   总被引:1,自引:0,他引:1  
新型内循环污泥浓缩消化反应器(ICSTD)处理污泥的启动运行试验采用某污水处理厂二沉池好氧活性污泥进行驯化培养,使反应器正常启动运行。在日处理量为50 L/d,进泥含水率为99.23%~99.46%,进泥VS/TS为0.65~0.73,进泥COD为4 115~5 780 mg/L,反应器容积负荷为1.31 kg COD/(m3·d)时,排泥含水率在96.2%~97.3%,排泥VS/TS为0.48~0.57,COD去除率在95%以上,出水pH在6.6~7.1,且上清液澄清。试验结果表明: ICSTD反应器处理污泥的启动试验,采用直接培养污泥启动的方式培养厌氧污泥历时66 d,能较快地培养厌氧污泥且运行稳定,对污泥的浓缩消化起到较好的作用,同时对反应器后续运行的消化效果提供了一个良好的条件。  相似文献   

2.
中温条件下,采用浓缩消化一体化反应器处理污泥,考察稳定运行阶段投配率、搅拌和容积负荷对反应器的运行效果的影响。研究结果表明,投配率在10%~20%之间,排泥的含水率有所降低,之后随着投配率的增加,排泥含水率急剧升高;投配率由10%至30%增加过程中,排泥有机物(VS)的去除率和产气量也呈上升的趋势,投配率由30%再增加时,VS的去除率和产气量急剧下降。搅拌对排泥的含水率影响较小,但能够提高VS去除率和产气量。随着进泥容积负荷的增大,反应器排泥含水率逐渐增大;随着容积负荷在一定范围内的增加, VS去除率也随之提高。  相似文献   

3.
高含固厌氧消化污泥流变特性   总被引:3,自引:0,他引:3  
戴晓虎  盖鑫  董滨 《环境工程学报》2014,8(9):3912-3918
采用完全混合式反应器R1、R2和R3(搅拌频率分别设为不搅拌、每10 min转动5 min和每10 min转动8min),在序批式运行的状态下,考察了不同搅拌频率对高含固厌氧消化过程中污泥流变特性的影响,探究了污泥表观黏度降低的主要原因以及污泥流变特性与各项物化指标的关系。结果表明,各个反应器消化污泥表观黏度μ值在发酵的前4天均出现大幅降低,下降幅度依次达到73.3%、77.8%和80.0%,从厌氧装置设计和运行的角度来看,脱水污泥高含固厌氧消化具有可行性。各反应器消化污泥的含固率(total solid,TS)以及挥发性固体(volatile solid,VS)占TS的比例VS/TS与表观黏度μ值以及稠度系数K值呈现显著性的指数关系,而污泥颗粒中胞外聚合物(extracellular polymeric substance,EPS)的含量与污泥表观黏度之间的相关关系则较弱。厌氧消化的初始阶段,微生物(主要是水解菌与产酸菌)的作用是污泥黏度急剧降低的主要原因。  相似文献   

4.
李果  何强  吴正松  彭晨 《环境工程学报》2015,9(3):1381-1388
利用自行研制的城镇生活垃圾与污水厂污泥一体化处理反应器对厨余垃圾好氧堆肥和污水处理厂污泥厌氧消化进行了实验研究,结果表明,在环境温度8~17.2℃的条件下,垃圾仓温度范围为17.2~50℃,堆肥垃圾含水率由(91.0±1.8)%降为(85.1±5.2)%,p H维持在5.92~7.40之间,VS/TS由0.78±0.06降为0.60±0.12,垃圾蛋白酶活性在第15天后维持在153.5~347.5 U/g DW。污泥仓温度主要范围为25~35℃,排泥含水率由(99.2±0.3)%降为(96.0±1.5)%,p H维持在6.77~6.97之间,VS/TS由0.66±0.07下降为0.44±0.11。污泥仓日均产气量为(44.7±8.6)L,其中甲烷平均体积分数为(61.32±4.68)%,污泥蛋白酶活性在第4天后稳定在0.98~1.78 U/m L之间。一体化反应器实现了厨余垃圾与污水厂污泥在同一反应器中集中处理,并利用垃圾堆肥时产生的热量为污泥浓缩消化提供温度条件。  相似文献   

5.
采用容积为200L的卧式厌氧消化反应器(以下简称卧式反应器),对高含固污泥(总固体(TS)≥10%(质量分数))的厌氧消化特性进行研究。通过序批运行、低负荷半连续运行、提负荷半连续运行逐步提高污泥TS从10.09%至12.58%,并对污泥颗粒的运动轨迹进行了计算机流体力学(CFD)模拟。结果表明,序批运行阶段污泥水解酸化特征显著;在低负荷半连续运行阶段,沼气产率平稳上升,在提负荷半连续运行阶段,沼气产率稳定在(0.359 2±0.011 0)m~3/(m~3·d),挥发性固体(VS)降解率稳定在22.05%±0.52%,高含固污泥在卧式反应器中厌氧消化产气性和稳定性良好。CFD模拟结果显示,污泥颗粒在卧式反应器中得到充分混合,卧式反应器运行稳定后,污泥厌氧消化剩余能量可达2.42MJ/(m~3·d),经济效益明显,具备良好的应用前景。  相似文献   

6.
针对MBR污泥开展热水解强化厌氧消化中试研究,考察了热水解对污泥性质、厌氧消化效率和污泥脱水性能的影响。结果表明,热水解后污泥中总固体(TS)、挥发性固体(VS)的含量基本不变,但污泥的溶解性总固体(s TS)和溶解性挥发性固体(s VS)含量提高至原泥的10倍左右,总固体解离度(TSDD)和挥发性固体解离度(VSDD)分别为31.7%和51.9%,同时污泥的黏度由927.8 m Pa·s降低至550.4 m Pa·s,污泥流动性显著增强。热水解处理可有效提高污泥厌氧消化反应效率,沼气产量和有机分解率均提高1倍,化学需氧量(COD)消减率由33%上升至44%,但热水解厌氧消化后污泥NH+4-N浓度为传统厌氧消化的2倍。此外热水解能有效改善污泥脱水性能,不添加任何药剂时,热水解污泥经板框压滤机脱水后含水率可降至33.29%。  相似文献   

7.
针对目前国内污泥处理处置存在的问题,为实现污泥浓缩消化一体化,开发了污泥一体化强化渗滤浓缩自然干化与消化新工艺反应器,并进行了城市水厂污泥处理试验.结果表明,在有机负荷为0.8 kg VSS/(m3·d)、平均水力停留时间为8.3 d、污泥停留时间为120 d的条件下,污泥有机物去除率可达到44.4%,排泥含水率达到79.1%,污泥消化与浓缩过程起到了相互促进的作用.渗滤液须抽回至污水处理厂处理.  相似文献   

8.
好氧/缺氧消化降解污泥特征分析   总被引:6,自引:4,他引:2  
为考察好氧/缺氧消化过程中污泥降解的特征,利用2个反应器进行对比试验,研究好氧/缺氧和好氧消化2个过程中VS的去除,pH和碱度变化,消化上清液中COD和氮元素变化等情况。试验结果表明:好氧/缺氧消化能够满足污泥稳定的要求,在常温条件下,消化16 d VS去除率即可达到38.2%,同时比好氧消化节约曝气能耗。好氧/缺氧消化对污泥中总氮的去除率高于传统的好氧消化,达到了36.4%,而且能够降低消化污泥上清液中的氨氮和硝态氮浓度。  相似文献   

9.
为了考察有效微生物(EM)和多功能复合微生物制剂(MCMP)对化粪池粪便污泥减量的强化效能,以化粪池粪便污泥为研究对象,采用中温(35℃)厌氧消化,研究EM和MCMP不同投加量(0~1.00%)对化粪池粪便污泥厌氧消化总固体(TS)、挥发性固体(VS)和COD的减量效果,考察EM和MCMP投加量与TS、VS和COD去除率间的相关关系。结果表明,投加0.005%~0.10%的EM和MCMP均有利于化粪池粪便污泥TS、VS和COD的去除;其中以投加0.01%的EM(E2处理)和0.01%的MCMP(M2处理)对TS、VS和COD的去除效果最好。E2处理TS、VS和COD的去除率分别为32.51%、42.34%和40.91%,分别比对照(CK)高5.83%、5.29%和7.13%;M2处理TS、VS和COD的去除率分别为33.74%、46.05%和43.33%;分别比CK高7.06%、9%和9.50%。对化粪池粪便污泥厌氧消化TS、VS和COD的减量作用效果表现为:MCMPEM。EM和MCMP的投加量与TS、VS和COD去除率间均存在一定的负相关关系;投加EM和MCMP的各处理的TS、VS和COD去除率两两间均表现为正相关关系。  相似文献   

10.
为了考察絮凝污泥与剩余活性污泥混合中温(35℃)厌氧消化效果,分析了不同混合比例、不同投配率下的总化学需氧量(TCOD)去除率、挥发性固体(VS)降解效果,通过p H值与氨氮浓度的变化来分析各反应器的稳定性。结果表明:污泥混合后消化效果明显得到提高,且污泥消化效率随着投配率的增加先提高后下降。5%投配率时,絮凝污泥/剩余污泥(VS比)为1∶2时厌氧消化效果最好,TCOD去除率达到47.8%,VS降解率达到46.8%,分解单位VS产气量达到了435 m L/g,p H值与氨氮浓度分别保持在7.4和269 mg/L左右,混合污泥厌氧消化系统较稳定。这说明与剩余污泥的混合消化能有效提高絮凝污泥的厌氧消化性能。污泥絮体的显微分析表明:厌氧消化过程中絮体面积百分比逐步减小,污泥结构逐步解体,可以解释污泥消化的微观过程。  相似文献   

11.
There is increasing interest in the United States in producing biosolids from municipal wastewater treatment that meet the criteria for Class A designation established by the U.S. Environmental Protection Agency. Class A biosolids are intended to be free of pathogens and also must meet requirements for reduction of the vector-attraction potential associated with untreated sludge. High-temperature processes are considered to produce Class A biosolids if the combination of operating temperature and treatment time exceeds minimum criteria, but this option is not applicable to mixed, continuous-flow reactors. Such reactors, or any combination of reactors that does not meet the holding time requirement at a specific temperature, must be demonstrated to inactivate pathogens to levels consistent with the Class A criteria. This study was designed to evaluate pathogen inactivation by thermophilic anaerobic digestion in a mixed, continuous-flow reactor followed by batch or plug-flow treatment. In this first of a two-part series, we describe the performance of a continuous-flow laboratory reactor with respect to physical and chemical operating parameters; microbial inactivation in the combined continuous-flow and batch treatment system is described in the second part. Sludges from three different sources were treated at 53 degrees C, while sludge from one of the sources was also treated at 55 and 51 degrees C. Relatively short hydraulic retention times (four to six days) were used to represent a conservative operating condition with respect to pathogen inactivation. Treatment of a fermented primary sludge led to an average volatile-solids (VS) destruction efficiency of 45%, while VS destruction for the other two sources was near or below 38%, the Class A criterion for vector attraction reduction. Consistent with other studies on thermophilic anaerobic digestion of sludges at short residence times, effluent concentrations of volatile fatty acids (VFAs) were relatively high. Also consistent with other studies, the most abundant VFA in the effluent was propionate. Gas production ranged from 0.3 to 0.5 m3/kg VS fed and from 0.8 to 1.3 m3/kg VS destroyed.  相似文献   

12.
耐酸厌氧消化污泥处理餐厨垃圾   总被引:1,自引:0,他引:1  
采用耐酸驯化的厌氧消化污泥处理餐厨垃圾,在酸性条件下(pH=4.5),对实验装置容积负荷从1.0kgVS/(m3·d)分9次逐级增加到5.0kgVS/(m3·d)的过程进行了跟踪监测,并较深入地研究了驯化污泥代谢活性和处理效果。实验结果表明,pH4.5的耐酸厌氧消化污泥,最佳投加负荷约为4.5kgVS/(m3·d),此负荷下容积产气率,CH4含量平均值均达最大,分别为1.68m3/(m3·d),75.0%。耐酸厌氧消化装置持续增料运行46d,产甲烷菌仍能保持较高的活性,其COD去除率范围为40.4%-75.0%,仍能保持pH7.2时处理效果的65.0%-91.8%,表明在低pH、低碱度下实现稳定的产甲烷过程是可行的。  相似文献   

13.
选取FeCl3和AlCl2·6H2O作为混凝剂对城市污水进行一级强化混凝处理,降低二级生物处理的进水负荷,减少污水生物处理系统的能量消耗。主要研究混凝过程投加的金属盐对一级强化混凝产生的初沉污泥中温厌氧消化的影响。和剩余污泥相比,初沉污泥更适合厌氧消化处理,污泥降解性能和产气性能更高。当采用城市污水一级强化混凝处理时,污泥中的金属和金属盐水解引起的pH降低,使混凝强化初沉污泥的厌氧消化受到一定抑制。随着污泥中铝含量的降低和铁含量的增加,厌氧消化的COD降解率和挥发性固体(Vs)降解率逐渐升高,生物气产量逐渐增大,产气速率加快。当混凝强化初沉污泥只含有铁时(铁含量为10.16mg/L),混凝强化初沉污泥厌氧消化效果最好,产气稳定,而且产气速率高,生物气产量为237mL,生物气甲烷含量为55.5%,降解单位Vs产气量为0.80L/g,均高于其他含铝的混凝强化初沉污泥。污泥中的铁对初沉污泥厌氧消化的抑制作用远远小于铝的作用,说明铁盐适合用于城市污水的一级强化混凝处理。  相似文献   

14.
The effect of an oxidative pre-treatment with ozone on the removal of Pharmaceutical and Personal Care Products (PPCPs) during the anaerobic digestion of sewage sludge has been investigated. Besides, the digested sludge characteristics in terms of pathogens content, dewatering properties, heavy metals content and linear alkylbenzene sulfonates (LAS) were determined. During ozonation (20mg O(3)/g TSS), about 8% of volatile solids (VS) and 60% of the chemical oxygen demand (COD) were solubilized. However, no mineralization was observed. The elimination of VS and total COD during anaerobic digestion were not affected by ozone treatment with efficiencies ranging from 60% to 65%. All PPCPs considered were removed during anaerobic treatment of sludge, with efficiencies ranging from 20% to 99%. No significant influence of ozone pre-treatment was observed on PPCPs elimination except for carbamazepine. Pathogens, heavy metals and LAS contents after conventional and pre-ozonation treatment of sewage sludge were below the legal requirements. However, the dewatering properties of sludge were deteriorated when the ozone pre-treatment was applied.  相似文献   

15.
为了解高效厌氧反应器的颗粒污泥特性,研究了生产性EGSB反应器处理造纸废水不同高度的颗粒污泥的固体浓度、外观形态和产甲烷活性。采用甲烷势自动测试系统测试产甲烷活性,测试时间3d。结果表明,颗粒污泥的固体浓度以及溶解性COD随高度的增加逐渐降低,有机质含量沿整个反应器高度不变。反应器内固体浓度和有机质含量平均值为Ts:(123±4)g/L,VS:(75±3)g/L,VS/TS:(61±3)%。溶解性COD浓度由723mg/L降低到449mg/L。反应器内的颗粒污泥产甲烷活性为(0.32±0.03)gCOD/gVSSd(112mLCH。/gVSSd)。反应器底部和顶部颗粒污泥的当量直径分别为169μm和145μm,颗粒污泥呈椭球状(圆度为2.6)。EGSB反应器内由于进水的上升流速较高,污泥颗粒处于膨胀状态,致使颗粒污泥特性沿反应器高度变化不大。  相似文献   

16.
金属铁铝对混凝强化初沉污泥中温厌氧消化的影响   总被引:1,自引:0,他引:1  
选取FeCl3和AlCl3·6H2O作为混凝剂对城市污水进行一级强化混凝处理,降低二级生物处理的进水负荷,减少污水生物处理系统的能量消耗。主要研究混凝过程投加的金属盐对一级强化混凝产生的初沉污泥中温厌氧消化的影响。和剩余污泥相比,初沉污泥更适合厌氧消化处理,污泥降解性能和产气性能更高。当采用城市污水一级强化混凝处理时,污泥中的金属和金属盐水解引起的pH降低,使混凝强化初沉污泥的厌氧消化受到一定抑制。随着污泥中铝含量的降低和铁含量的增加,厌氧消化的COD降解率和挥发性固体(VS)降解率逐渐升高,生物气产量逐渐增大,产气速率加快。当混凝强化初沉污泥只含有铁时(铁含量为10.16 mg/L),混凝强化初沉污泥厌氧消化效果最好,产气稳定,而且产气速率高,生物气产量为237 mL,生物气甲烷含量为55.5%,降解单位VS产气量为0.80 L/g,均高于其他含铝的混凝强化初沉污泥。污泥中的铁对初沉污泥厌氧消化的抑制作用远远小于铝的作用,说明铁盐适合用于城市污水的一级强化混凝处理。  相似文献   

17.
污泥加热预处理对中温厌氧消化的影响   总被引:1,自引:1,他引:0  
对污泥加热预处理给中温厌氧混合消化和污泥单独消化带来的影响进行了研究.研究结果表明,污泥加热预处理有利于提高混合消化对 COD 的去除率,尤其是 SCOD 的去除率由 77%增长到 93%,但不利于 TS 和 VS 的去除;而对污泥单独消化,预处理则不利于有机物的去除.采用加热预处理后的污泥进样,混合消化和污泥单独消化的甲烷产气量均有所提高.  相似文献   

18.
采用耐酸驯化的厌氧消化污泥处理餐厨垃圾,在酸性条件下(pH=4.5),对实验装置容积负荷从1.0 kg VS/(m3·d)分9次逐级增加到5.0 kg VS/(m3·d)的过程进行了跟踪监测,并较深入地研究了驯化污泥代谢活性和处理效果。实验结果表明,pH 4.5的耐酸厌氧消化污泥,最佳投加负荷约为4.5 kg VS/(m3·d),此负荷下容积产气率,CH4含量平均值均达最大,分别为1.68 m3/(m3·d),75.0%。耐酸厌氧消化装置持续增料运行46 d,产甲烷菌仍能保持较高的活性,其COD去除率范围为40.4%~75.0%,仍能保持pH 7.2时处理效果的65.0%~91.8%,表明在低pH、低碱度下实现稳定的产甲烷过程是可行的。  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司    京ICP备09084417号-23

京公网安备 11010802026262号