1.
The objective of this study was to produce a generic monoclonal antibody for determination of penicillins residues in milk. The compound 6-aminopenicillanic acid was used as the template to synthesize two novel generic haptens that were used to produce the monoclonal antibodies. The obtained monoclonal antibodies simultaneously recognized 11 penicillin drugs (amoxicillin, ampicillin, penicillin G, penicillin V, sulbenicillin, carbencillin, methicillin, cloxacillin, dicloxacillin, oxacillin, and nafcillin). After evaluation of different reagent combinations, a heterologous indirect competitive enzyme immunoassay was developed to multi-determine the 11 drugs in milk. The crossreactivities to the 11 drugs were in a range of 16%–117% and the limits of detection were in a range of 0.7–9.3 ng/mL depending on the drug. The recoveries from the fortified blank milk were in a range of 77.6%–99.4% with coefficients of variation lower than 13.5%. This method could be used as a rapid screen tool for routine monitoring the residues of the 11 penicillin drugs in animal derived foods.  相似文献   

2.
The objective of this study was to produce a generic antibody for immunoassay of fluoroquinolone drugs in meat. Two novel haptens of sarafloxacin were synthesized that were used to produce the monoclonal antibodies. The obtained monoclonal antibodies simultaneously recognized 12 fluoroquinolone drugs (sarafloxacin, diflocaxin, marbofloxacin, ofloxacin, ciprofloxacin, enrofloxacin, norfloxacin, pefloxacin, lomefloxacin, amifloxacin, enofloxacin and danofloxacin). After evaluation of different coating antigen/antibody combinations, a heterologous competitive indirect enzyme linked immunosorbent assay (ELISA) was developed to determine the 12 drugs. The crossreactivities to these analytes were in the range of 18%–113% and the limits of detection were in the range of 0.8–6.5 ng/mL depending on the compound. Eight fluoroquinolones licensed as veterinary drugs in China were fortified into blank chicken for ELISA analysis. The recoveries were in the range of 67.6%–94.6% with coefficients of variation lower than 12.4%. Therefore, this method could be used as a screen tool for routine monitoring of the residues of these fluoroquinolone drugs in animal derived foods.  相似文献   

3.
The objective of this study was to produce a generic monoclonal antibody for multi-determination of the residues of tetracycline drugs in bovine muscle and milk. Two new immunogens of doxycycline were prepared that were used to produce the monoclonal antibodies. Results showed the obtained antibodies simultaneously recognized seven tetracycline drugs (doxycycline, tetracycline, chlortetracycline, oxytetracycline, minocycline, methacycline, demeclocycline). The obtained antibodies and three coating antigens were arranged into six combinations to optimize the reagents combination. After comparison of the performances of these combinations, a heterologous indirect competitive ELISA was then used to determine the seven tetracyclines in bovine muscle and milk. The crossreactivities to the seven analytes were in the range of 47%–102% and the limits of detection were in the range of 1.5–6.9 ng/mL depending on the compound. The recoveries of the seven drugs from fortified blank samples were in the range of 75.3%–106.8% with coefficients of variation lower than 10.9%. Therefore, this method could be used as a multi-analytes screen tool for routine monitoring of the residues of these tetracycline drugs in bovine muscle and milk.  相似文献   

4.
The objective of the present study was to develop a multi-analyte immunoassay for the determination of eight red dyes in food samples. Two dye intermediates (2-hydroxy-1-naphthoic acid and 1-amino-2-naphthol) were used as the haptens to produce the monoclonal antibodies. The obtained monoclonal antibodies recognized Sudan 1–4, Para red, Sudan red G, Sudan red B and Acid orange II simultaneously. After evaluation of different antibody/coating antigen combinations, a heterologous indirect competitive enzyme linked immunosorbent assay was developed to determine the eight red dyes in food samples (chili oil, chili powder, tomato sauce, hotpot seasoning). The crossreactivities to the eight analytes were in the range of 61%–79% (with β-naphthol as 100%), and the limits of detection were in the range of 1.3–1.9 ng/mL. The recoveries of the eight analytes from the fortified blank samples were in the range of 84.2%–115% with coefficients of variation lower than 18.3%. Therefore, this method could be used as a rapid and simple tool to detect the residues of the eight red dyes in foods.  相似文献   

5.
In this study, 2-chlorophenothiazine was used to synthesize a hapten for production of monoclonal antibody. The obtained monoclonal antibody showed high crossreactivities to chlorpromazine, promethazine and perphenazine, and showed low crossreactivities to acepromazine and fluphenazine. After evaluation of three coating antigens, a heterologous competitive indirect enzyme linked immunosorbent assay was developed to determine the five phenothiazines in animal feeds and the residues of chlorpromazine, promethazine and perphenazine in meat. The crossreactivities to the five analytes were in a range of 2.4%–98%. The limits of detection for the five drugs in feeds were in a range of 0.1–3.0 μg g?1, and that for chlorpromazine, promethazine and perphenazine in meat were in a range of 0.5–0.8 ng g?1. Their recoveries from standards fortified blank samples (chicken, pork and feeds) were in a range of 74.1%–96.5% with coefficients of variation of 6.4%–15.1%. Therefore, this method could be used as a rapid screen tool to determine phenothiazine drugs in animal feeds and animal derived foods.  相似文献   

6.
Tian H 《Chemosphere》2011,83(3):349-355
A sensitive method for determination of chloramphenicol, enrofloxacin and 29 pesticides residues in bovine milk by high-performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS) was developed. Residues of the targets were extracted from milk with acetonitrile, cleaned up by C18-SPE cartridge, and then determined by HPLC-MS/MS. The MS detection was operated in positive or negative ionization mode, depending on the compounds. For confirmation of each target compound, two precursor ion > product ion transitions were selected by multi-reaction monitoring mode (MRM). The method showed good linearity for all the tested compounds over the studied concentration range with correlation coefficient higher than 0.9910. Recoveries for the studied compounds at three spiked levels (0.05, 0.10, 0.19 mg kg−1) in bovine milk were in the range of 71-107% with RSDs not larger than 13.7%, except that recoveries of trifluralin ranged between 62% and 70% at the spiked levels. Limits of quantitation for the analytes were estimated to range between 0.03 × 10−3 and 14.5 × 10−3 mg kg−1. The proposed method was applied for the determination of the analytes residues in real samples. The found levels of the analytes in milk samples were lower than maximum residues levels (MRL).  相似文献   

7.
A sensitive biotin–streptavidin‐amplified enzyme‐linked immunosorbent assay (BA‐ELISA) method was developed for detecting non‐steroidal anti‐inflammatory drug ketoprofen. Compared with traditional ELISA method, the sensitivity of proposed immunoassay was enhanced by the biotin–streptavidin system. Under the optimal condition, the median inhibitory concentration (IC50) was 0.25 ng mL?1, with minor cross‐reactivity to a number of structural analogs. This developed assay was successfully applied to detect the ketoprofen residues in different fish samples, and good recoveries (72.6–105.5%) were obtained. The results indicated that this immunoassay method could specifically detect trace ketoprofen residues and could be widely used for routine monitoring of food samples.  相似文献   

8.
Burke ER  Holden AJ  Shaw IC 《Chemosphere》2003,50(4):529-535
A method has been developed for the analysis of organochlorine pesticides in human milk using solvent extraction, Florisil solid phase extraction clean-up and analysis by gas chromatography with an electron capture detector. The recovery of analytes from spiked milk samples was in the range 53 +/- 1% to 109 +/- 7% (n = 9). A small number of samples were obtained from women in a rural and an urban area of Indonesia and analysed using the developed method. The results are reported on a milk fat basis. All samples contained detectable residues of p,p'-DDT (urban mean 0.11 +/- 0.18 mgkg(-1) (n = 5), rural mean 0.07 +/- 0.03 mg kg(-1) (n = 5)) and p,p'-DDE (urban mean 0.05 +/- 0.04 m kg(-1) (n = 5), rural mean 0.76 +/- 1.46 mg kg(-1) (n = 5)). Residues of HCB, betaHCH, alpha-endosulfan and dieldrin were also detected in some samples. There was no significant difference (at the 95% confidence level) in levels of pesticides between urban and rural areas. The levels of organochlorine pesticides in milk from Indonesian women were lower than those reported from Indonesian women exposed to DDT through malaria eradication schemes and were similar to levels reported from UK and Japan.  相似文献   

9.
The effectiveness of homologous and heterologous formats in a nanocolloidal gold-based immunoassay for pesticide residue determination was investigated. Parathion, one of the most toxic organophosphorus pesticides, was used as the target analyte. One-step homologous and heterologous test strips based on a nanocolloidal gold-labeled monoclonal antibody were developed for the rapid detection of parathion residues. The results showed that the heterologous format was more effective than the homologous format, being more sensitive, more specific to parathion and more tolerant of matrix interferences. The best competitive hapten was found to have a moderate heterology and the opposite electronic distribution to the immunizing hapten. The detection limits for parathion using the preferred heterologous strip were 1 μg/L in water samples and 5 μg/kg in soil and food samples.  相似文献   

10.
The effectiveness of homologous and heterologous formats in a nanocolloidal gold-based immunoassay for pesticide residue determination was investigated. Parathion, one of the most toxic organophosphorus pesticides, was used as the target analyte. One-step homologous and heterologous test strips based on a nanocolloidal gold-labeled monoclonal antibody were developed for the rapid detection of parathion residues. The results showed that the heterologous format was more effective than the homologous format, being more sensitive, more specific to parathion and more tolerant of matrix interferences. The best competitive hapten was found to have a moderate heterology and the opposite electronic distribution to the immunizing hapten. The detection limits for parathion using the preferred heterologous strip were 1 μg/L in water samples and 5 μg/kg in soil and food samples.  相似文献   

11.
The molecular recognition mechanism of an antibody for its hapten is very interesting. The objective of this research was to study the intermolecular interactions of an anti-amoxicillin antibody with penicillin drugs. The single chain variable fragment (ScFv) antibody was generated from a hybridoma cell strain excreting the monoclonal antibody for amoxicillin. The recombinant ScFv antibody showed similar recognition ability for penicillins to its parental monoclonal antibody: simultaneous recognizing 11 penicillins with cross-reactivities of 18–107%. The three-dimensional structure of the ScFv antibody was simulated by using homology modeling, and its intermolecular interactions with 11 penicillins were studied by using molecular docking. Results showed that three CDRs are involved in antibody recognition; CDR L3 Arg 100, CDR H3 Tyr226, and CDR H3 Arg 228 were the key contact amino acid residues; hydrogen bonding was the main antibody–drug intermolecular force; and the core structure of penicillin drugs was the main antibody binding position. These results could explain the recognition mechanism of anti-amoxicillin antibody for amoxicillin and its analogs. This is the first study reporting the production of ScFv antibody for penicillins and stimulation studying its recognition mechanism.  相似文献   

12.
A simple, sensitive, reliable method was developed for the simultaneous determination of organochlorine and pyrethriod pesticide residues in Chinese patent medicines Six ingredient rehmannia pills and Xiaoyao pills. These pesticides were extracted by ethyl acetate. The extraction time and volume of ethyl acetate were optimized. Cleanup of extracts was performed with dispersive-solid phase extraction using graphitized carbon black as the sorbent. The determination of pesticides in the final extracts was carried out by gas chromatography–tandem mass spectrometry in multiple reaction monitoring mode (GC-MS/MS, MRM). The linearity of the calibration curves is good in matrix-matched standard and yields the coefficients of determination (R2) ≥0.99 for all of the target analytes. Under optimized conditions, the average recoveries (five replicates) for most pesticides range from 75.5% to 114.6%, and RSDs are less than 10.0%. The LODs of 18 pesticides in Six ingredient rehmannia pill and Xiaoyao pills are in the range of 0.01–8.82 μg kg?1. The developed method meets the requirements of pesticide residue analysis and could be effectively used for routine analysis of the organochlorine and pyrethriod pesticide residues in Six ingredient rehmannia pills and Xiaoyao pills.  相似文献   

13.
Extraction and quantification of pesticide residue from the milk matrix at or below the established maximum residue limit (MRL) is a challenging task for both analytical chemists and the regulatory institutions to take corrective actions for the human health and safety. The main aim of the study is to develop a simple rapid and less expensive QuEChERS extraction and cleanup method for simultaneous analysis of 41 multiclass pesticide residue in milk by gas chromatography-electron capture detector (GC-ECD), followed by confirmation of the residues with gas chromatography-mass spectrometer (GC-MS). Effect of sorbent type, temperature, spiking concentration, matrix effect (ME), measurement uncertainty (MU), inter- and intra-assay repeatability, reproducibility of recovery, and trueness of the results were investigated to validate the effectiveness of the method. Limit of determination (LOD) and limit of quantitation (LOQ) for all the analytes ranged within 0.001–0.02 and 0.002–0.05 µg mL?1, respectively. The % recovery of all the pesticides ranged between 91.38 and 117.56% with relative standard deviation (RSD) below 2.79%. The MU for all the analytes was ≤29% of respective LOQs, and except for few pesticides, the ME was largely negative. The method fulfilled all the SANTE guidelines and thus can be extended for routine analysis of multiclass pesticide residue in milk.  相似文献   

14.

An antibody-based rapid, quantitative, and qualitative tube enzyme-linked immunosorbent assay (tube-ELISA) was developed and used to determine carbaryl (1-naphthyl methylcarbamate) residues in agricultural products (apple, Chinese cabbage, rice, and barley). The tube-ELISA is a competitive immunoassay in which the antibody is coated in the polystyrene tube, with a dynamic range between 0.7 and 46.3 μg kg?1. Carbaryl was extracted from each agricultural sample by hand-shaking with methanol and examined for application to on-site analysis. After the liquid extraction, the sample extracts diluted with buffer were analyzed by rapid tube-ELISA directly. The overall test time was around 15–30 min, including sample preparation and assay performance. The results obtained from tube-ELISA correlated well with high-performance liquid chromatography (R 2 > 0.9). The study shows that tube-ELISA is useful as a quality control tool and can be used to quantitatively detect carbaryl as well.  相似文献   

15.
This paper describes the isolation of monoclonal antibodies and the development of competitive immunoassays to pesticide metabolites of the fungicides imazalil, carbendazim and thiabendazole. The metabolite specific hydroxyl residues were used as the reactive group with which to link the metabolite to the carrier proteins Keyhole Limpet Haemocyanin (KLH) and Bovine Serum Albumin (BSA). In each case immune responses in mice were raised and monoclonal antibodies were produced. Antibodies were developed into competitive ELISAs to the appropriate metabolite. The antibody raised to a metabolite of imazalil was optimised into a competitive ELISA format which had an assay IC50 of 7.5 μg/L and a limit of detection (LOD) of 1.1 μg/L. A single antibody isolated against the metabolite of carbendazim had assay IC50s of 3.2 and 2.7 μg/L for the metabolites of carbendazim and thiabendazole respectively with an LOD of 0.38 μg/L for both. These sensitive immunoassays may have application in the monitoring of human exposure to these fungicide residues either by occupational or non-occupational routes.  相似文献   

16.
This paper describes the isolation of monoclonal antibodies and the development of competitive immunoassays to pesticide metabolites of the fungicides imazalil, carbendazim and thiabendazole. The metabolite specific hydroxyl residues were used as the reactive group with which to link the metabolite to the carrier proteins Keyhole Limpet Haemocyanin (KLH) and Bovine Serum Albumin (BSA). In each case immune responses in mice were raised and monoclonal antibodies were produced. Antibodies were developed into competitive ELISAs to the appropriate metabolite. The antibody raised to a metabolite of imazalil was optimised into a competitive ELISA format which had an assay IC50 of 7.5 μg/L and a limit of detection (LOD) of 1.1 μg/L. A single antibody isolated against the metabolite of carbendazim had assay IC50s of 3.2 and 2.7 μg/L for the metabolites of carbendazim and thiabendazole respectively with an LOD of 0.38 μg/L for both. These sensitive immunoassays may have application in the monitoring of human exposure to these fungicide residues either by occupational or non-occupational routes.  相似文献   

17.
A novel differential pulse voltammetry (DPV) method was developed for the simultaneous analysis of herbicides in water. A mixture of four herbicides, atrazine, simazine, propazine and terbuthylazine was analyzed simultaneously and the complex, overlapping DPV voltammograms were resolved by several chemometrics methods such as partial least squares (PLS), principal component regression (PCR) and principal component–artificial networks (PC–ANN). The complex profiles of the voltammograms collected from a synthetic set of samples were best resolved with the use of the PC–ANN method, and the best predictions of the concentrations of the analytes were obtained with the PC-ANN model (%RPET = 6.1 and average %Recovery = 99.0). The new method was also used for analysis of real samples, and the obtained results were compared well with those from the GC-MS technique. Such conclusions suggest that the novel method is a viable alternative to the other commonly used methods such as GC, HPLC and GC-MS.  相似文献   

18.
This article is a review of new and versatile optical-immunoassay instrumentation for water monitoring developed through two European Union projects, RIver ANAlyser (RIANA) and Automated Water Analyser Computer Supported System (AWACSS). Both projects utilise immunoassay techniques to isolate the analytes and Total Internal Reflection Fluorescence (TIRF) to quantify them. Completed in 1999, the RIANA project developed a sensitive and cost-effective analytical system capable of simultaneous detection of multiple-analytes in real-world water samples. The AWACSS project has been in progress since 2001 and is developing rugged-but-sensitive instrumentation that will detect up to 30 analytes simultaneously, will operate unattended, and will have networking capability.  相似文献   

19.
An antibody-based rapid, quantitative, and qualitative tube enzyme-linked immunosorbent assay (tube-ELISA) was developed and used to determine carbaryl (1-naphthyl methylcarbamate) residues in agricultural products (apple, Chinese cabbage, rice, and barley). The tube-ELISA is a competitive immunoassay in which the antibody is coated in the polystyrene tube, with a dynamic range between 0.7 and 46.3 microg kg(-1). Carbaryl was extracted from each agricultural sample by hand-shaking with methanol and examined for application to on-site analysis. After the liquid extraction, the sample extracts diluted with buffer were analyzed by rapid tube-ELISA directly. The overall test time was around 15-30 min, including sample preparation and assay performance. The results obtained from tube-ELISA correlated well with high-performance liquid chromatography (R2 > 0.9). The study shows that tube-ELISA is useful as a quality control tool and can be used to quantitatively detect carbaryl as well.  相似文献   

20.
A new method for specific antibody production was developed using antibody (Ab)-pesticide complex as a unique immunogen. Parathion (PA) was the targeted pesticide, and rabbit polyclonal antibody (Pab) and mouse monoclonal antibody (Mab) were used as carrier proteins. The Ab-PA complexes were generated by conjugating the two antibodies with an excessive dosage of PA. It was shown that the sensitivity of homologous enzyme-linked immunosorbent assay (ELISA) using the new antibodies was similar to that using original antibodies. However, the new mouse Pab had not only similar positive recognizing spectrum as the original Mab, but also a significantly improved sensitivity in heterologous ELISA when some recognizable competitors were applied. IC50 value of ELISA based on a combination of the new mouse Pab and hapten 9 was 0.24 ng/mL, which was 445.54 times as that of the homologous ELISA. An Ab-pesticide complex may be a suitable alternative immunogen for producing highly specific antibody to improve the immunoassay sensitivity.  相似文献   