首页 | 官方网站   微博 | 高级检索  
相似文献
 共查询到6条相似文献,搜索用时 15 毫秒
1.
Two-photon excitation laser scanning fluorescence microscopy (2p-LSM) was compared with UV-excitation confocal laser scanning fluorescence microscopy (UV-CLSM) in terms of three-dimensional (3-D) calcium imaging of living cells in culture. Indo-1 was used as a calcium indicator. Since the excitation volume is more limited and excitation wavelengths are longer in 2p-LSM than in UV-CLSM, 2p-LSM exhibited several advantages over UV-CLSM: (1) a lower level of background signal by a factor of 6–17, which enhances the contrast by a factor of 6–21; (2) a lower rate of photobleaching by a factor of 2–4; (3) slightly lower phototoxicity. When 3-D images were repeatedly acquired, the calcium concentration determined by UV-CLSM depended strongly on the number of data acquisitions and the nuclear regions falsely exhibited low calcium concentrations, probably due to an interplay of different levels of photobleaching of Indo-1 and autofluorescence, while the calcium concentration evaluated by 2p-LSM was stable and homogeneous throughout the cytoplasm. The spatial resolution of 2p-LSM was worse by 10% in the focal plane and by 30% along the optical axis due to the longer excitation wavelength. This disadvantage can be overcome by the addition of a confocal pinhole (two-photon excitation confocal laser scanning fluorescence microscopy), which made the resolution similar to that in UV-CLSM. These results indicate that 2p-LSM is preferable for repeated 3-D reconstruction of calcium concentration in living cells. In UV-CLSM, 0.18-mW laser power with a 2.φ pinhole (in normalized optical coordinate) gives better signal-to-noise ratio, contrast and resolution than 0.09-mW laser power with a 4.9-φ pinhole. However, since the damage to cells and the rate of photobleaching is substantially greater under the former condition, it is not suitable for repeated acquisition of 3-D images.  相似文献   

2.
A new experimental apparatus for temperature-controlled microscopy has been developed for the study of the temperature dependency of developmental processes in the nematode Caenorhabditis elegans . However, the application of this apparatus is rather general and can be used for a wide range of temperatures between − 10 and 90 °C. The new apparatus is easy to use, inexpensive, simple to construct, and is designed for precise temperature control of oil-immersion microscopy using epifluorescence. Thermal analysis of the experimental apparatus shows the effects of each of its components, as well as the effects of uncertainty in temperature measurements. Finally, results of this study indicate that: (i) embryos incubated and imaged at temperatures of 8 °C and below do not elongate; (ii) the initial elongation rate is strongly temperature-dependent between 9 and 25 °C.  相似文献   

3.
A new depth encoding system (DES) is presented, which makes it possible to calculate, display, and record the z-axis position continuously during in vivo imaging using tandem scanning confocal microscopy (TSCM). In order to verify the accuracy of the DES for calculating the position of the focal plane in the cornea both in vitro and in vivo, we compared TSCM measurements of corneal thickness to measurements made using an ultrasonic pachymeter (UP, a standard clinical instrument) in both enucleated rabbit, cat, and human eyes (n = 15), and in human patients (n = 7). Very close agreement was found between the UP and TSCM measurements in enucleated eyes; the mean percent difference was 0.50 ± 2.58% (mean ± SD, not significant). A significant correlation (R=0.995, n=15, p< 0.01) was found between UP and TSCM measurements. These results verify that the theoretical equation for calculating focal depth provided by the TSCM manufacturer is accurate for corneal imaging. Similarly, close agreement was found between the in vivo UP and TSCM measurements; the mean percent difference was 1.67 ± 1.38% (not significant), confirming that z-axis drift can be minimized with proper applanation of the objective. These results confirm the accuracy of the DES for imaging of the cornea both ex vivo and in vivo. This system should be of great utility for applications where quantitation of the three-dimensional location of cellular structures is needed.  相似文献   

4.
We have employed field-emission secondary electron microscopy (FESEM) for morphological evaluation of freeze-fractured frozen-hydrated renal epithelial LLC-PK1 cells prepared with our simple cryogenic sandwich-fracture method that does not require any high-vacuum freeze-fracture instrumentation (Chandra et al. (1986) J. Microsc. 144 , 15–37). The cells fractured on the substrate side of the sandwich were matched one-to-one with their corresponding complementary fractured faces on the other side of the sandwich. The FESEM analysis of the frozen-hydrated cells revealed three types of fracture: (i) apical membrane fracture that produces groups of cells together on the substrate fractured at the ectoplasmic face of the plasma membrane; (ii) basal membrane fracture that produces basal plasma membrane-halves on the substrate; and (iii) cross-fracture that passes randomly through the cells. The ectoplasmic face (E-face) and protoplasmic face (P-face) of the membrane were recognized based on the density of intramembranous particles. Feasibility of fractured cells was shown for intracellular ion localization with ion microscopy, and fluorescence imaging with laser scanning confocal microscopy. Ion microscopy imaging of freeze-dried cells fractured at the apical membrane revealed well-preserved intracellular ionic composition of even the most diffusible ions (total concentrations of K+, Na+ and Ca+). Structurally damaged cells revealed lower K+ and higher Na+ and Ca+ contents than in well-preserved cells. Frozen-freeze-dried cells also allowed imaging of fluorescently labelled mitochondria with a laser scanning confocal microscope. Since these cells are prepared without washing away the nutrient medium or using any chemical pretreatment to affect their native chemical and structural makeup, the characterization of fracture faces introduces ideal sample types for chemical and morphological studies with ion and electron microscopes and other techniques such as laser scanning confocal microscopy, atomic force microscopy and near-field scanning optical microscopy.  相似文献   

5.
Cultured rat fibroblasts were exposed to millimolar concentrations of forty-four non-cationic fluorescent probes, of very varied physico-chemical properties. Mitochondrial staining occurred with nineteen of these probes, nine of which were nominally anionic and ten nominally non-ionic. All nineteen were in fact lipophilic weak acids. Using structural parameters these could be specified numerically as follows: electric charge ≤ 0; log P(less-ionized form) < 0; and pKa ~ 7. In addition to these structural variables, dye concentration and the time of exposure of cells to probes were significant factors for the staining of mitochondria. Accumulation of these compounds can be understood in terms of ion-trapping of hydrophilic salts of lipophilic weak acids, due to the internal pH of respiring mitochondria being higher than the cytosolic pH. As a case example of the application of this approach, the mode of action of many inhibitors of mitochondrial anabolism is discussed in terms of the mechanisms introduced here.  相似文献   

6.
This work is the first to deal with the application of color cathodoluminescence scanning electron microscopy (CCL SEM) and a novel version of combined imaging with backscattered electrons (CCL+BSE SEM) for the study of the composition of bile and its precipitation mechanisms. The present study demonstrates cholesterol, protein, and bilirubin distribution in deposits of normal and abnormal humanbile after solution evaporation to full dryness. Qualitative CCL SEM analysis showed that dried bile remnants include different proportions of the above components. Three types of deposits were observed: Arborescent crystals, typical cholesterol crystals, and amorphous bilirubin particles. The selection of crystalline or amorphous precipitate phases is determined by the dehydration/concentration process. The findings may explain key features in lithogenesis.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司    京ICP备09084417号

京公网安备 11010802026262号