首页 | 官方网站   微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Both high and low indoor relative humidity (RH) directly impact Indoor Air Quality (IAQ), an important school health concern. Prior school studies reported a high prevalence of mold, roaches, and water damage; however, few examined associations between modifiable classroom factors and RH, a quantitative indicator of dampness. We recorded RH longitudinally in 134 North Carolina classrooms (n = 9066 classroom‐days) to quantify the relationships between modifiable classroom factors and average daily RH below, within, or above levels recommended to improve school IAQ (30–50% or 30–60% RH). The odds of having high RH (>60%) were 5.8 [95% Confidence Interval (CI): 2.9, 11.3] times higher in classrooms with annual compared to quarterly heating, ventilating, and air‐conditioning (HVAC) system maintenance and 2.5 (95% CI: 1.5, 4.2) times higher in classrooms with HVAC economizers compared to those without economizers. Classrooms with direct‐expansion split systems compared to chilled water systems had 2.7 (95% CI: 1.7, 4.4) times higher odds of low RH (<30%). When unoccupied, classrooms with thermostat setbacks had 3.7 (95% CI: 1.7, 8.3) times the odds of high RH (>60%) of those without setbacks. This research suggests actionable decision points for school design and maintenance to prevent high or low classroom RH.  相似文献   

2.
Poor indoor air quality (IAQ) in schools is related to increased symptom reporting in students. We investigated whether parental worry about school IAQ influences this association. Data came from survey collected from five Finnish primary schools with observed IAQ problems and five control schools. Parents (n = 1868) of primary school students reported worry about IAQ in schools and symptoms of their children. Associations between observed IAQ problems, worry, and five symptom scores (ie, respiratory, lower respiratory, eye, skin, and general symptoms) were analyzed using multivariate logistic regression and mediation analysis. Parents were on average more worried in schools with observed IAQ problems. Observed IAQ problems were strongly associated with increased worry and all symptoms under study (unadjusted ORs ranged between 1.48 [95% CI 1.48‐2.16] and 2.70 [95% CI 1.52‐5.17]). Parental worry was associated with all symptoms (unadjusted ORs ranged between 2.49 [95% CI 1.75‐3.60] and 4.92 [95% CI 2.77‐9.40]). Mediation analyses suggested that parental worry might partially explain the association between observed IAQ problems and symptom reporting (proportion mediated ranged between 67% and 84% for the different symptoms). However, prospective studies are needed to assess causal relationships between observed IAQ problems, worry, and symptom reporting in schools.  相似文献   

3.
Moisture damage can influence the subjective assessment of indoor air quality (subjective IAQ) in various ways. We studied whether the frequency of symptoms reported across students at school level mediates the relationship between observed mold and dampness in a school building and students’ subjective IAQ. To answer this research question, we tested a multilevel path model. The analyzed data were created by merging two nationwide data sets: (a) survey data from students, including information on subjective IAQ (N = 24,786 students); (b) data from schools, including information on mold and dampness in a school building (N = 222). After the background variables were adjusted, schools’ observed mold and dampness were directly and significantly related to poor subjective IAQ (standardized beta (β)= 0.22, P = .002). In addition, in schools with mold and dampness, students reported significantly more symptoms (β = 0.22, P = .023) than in schools without; the higher the prevalence of symptoms at school level, the worse the students’ subjective IAQ (β = 0.60, P < .001). This indirect path was significant (P = .023). In total, schools’ observed mold and dampness and student-reported symptoms explained 52% of the between-school variance in subjective IAQ.  相似文献   

4.
Little is known whether parent's indoor environment quality (IEQ)-related symptoms or health perceptions influence the risk of self- or parent-reported symptoms in their children. We assessed (i) the association of parents’ IEQ-related symptoms with IEQ-related symptoms in their children at school and (ii) whether parental IEQ-related health worry increases the risk for children's symptoms. We used two Finnish studies: a national, population-based survey of indoor air and related health problems (n = 611 parents) and a subset of survey for all primary school pupils (grade 3–6) and their parents in Helsinki, which also included school IEQ-related symptoms reported by children (n = 1617 parent-child dyads). In the school survey, parent's own symptoms increased strongly their reporting of their children's symptoms at school (aOR 4.0, 95% CI 2.7–6.0 for parents experiencing a lot of symptoms) and also symptoms reported by the child itself (aOR 2.2, 95% CI 1.5–3.1). Similar, but slightly weaker associations were seen with parental IEQ-related health worries. Results remained unchanged when adjusted for the IEQ of school buildings or parental and children's allergic diseases. Similar associations were seen in the national survey between parent's symptoms at work and child's symptoms at school. The results suggest that parents’ health perceptions may increase the reporting of children's IEQ-related symptoms even more than is typically seen for many indoor air contaminants.  相似文献   

5.
This study assessed the relationship between teacher‐reported symptoms and classroom carbon dioxide (CO2) concentrations. Previous studies have suggested that poor indoor ventilation can result in higher levels of indoor pollutants, which may affect student and teacher health. Ten schools (9 elementary, 1 combined middle/high school) in eight New York State school districts were visited over a 4‐month period in 2010. Carbon dioxide concentrations were measured in classrooms over 48‐h, and teachers completed surveys assessing demographic information and self‐reported symptoms experienced during the current school year. Data from 64 classrooms (ranging from 1 to 9 per school) were linked with 68 teacher surveys (for four classrooms, two surveys were returned). Overall, approximately 20% of the measured classroom CO2 concentrations were above 1000 parts per million (ppm), ranging from 352 to 1591 ppm. In multivariate analyses, the odds of reporting neuro‐physiologic (i.e., headache, fatigue, difficulty concentrating) symptoms among teachers significantly increased (OR = 1.30, 95% CI = 1.02–1.64) for every 100 ppm increase in maximum classroom CO2 concentrations and were non‐significantly increased in classrooms with above‐median proportions of CO2 concentrations greater than 1000 ppm (OR = 2.26, 95% CI = 0.72–7.12).  相似文献   

6.
A previous study showed that classical building-related symptoms (BRS) were related to indoor dust and microbial toxicity via boar sperm motility assay, a sensitive method for measuring mitochondrial toxicity. In this cross-sectional study, we analyzed whether teachers’ most common work-related non-literature-known BRS (nBRS) were also associated with dust or microbial toxicity. Teachers from 15 schools in Finland completed a questionnaire evaluating 20 nBRS including general, eye, respiratory, hearing, sleep, and mental symptoms. Boar sperm motility assay was used to measure the toxicity of extracts from wiped dust and microbial fallout samples collected from teachers’ classrooms. 231 teachers answered a questionnaire and their classroom toxicity data were recorded. A negative binomial mixed model showed that teachers’ work-related nBRS were 2.9-fold (95% CI: 1.2-7.3) higher in classrooms with highly toxic dust samples compared to classrooms with non-toxic dust samples (p = 0.024). The RR of work-related nBRS was 1.8 (95% CI: 1.1-2.9) for toxic microbial samples (p = 0.022). Teachers’ BRS appeared to be broader than reported in the literature, and the work-related nBRS were associated with toxic dusts and microbes in classrooms.  相似文献   

7.
Subjective evaluation of Indoor Air Quality (subjective IAQ) reflects both building‐related and psychosocial factors, but their associations have rarely been studied other than on the individual level in occupational settings and their interactions have not been assessed. Therefore, we studied whether schools’ observed indoor air problems and psychosocial factors are associated with subjective IAQ and their potential interactions. The analysis was performed with a nationwide sample (N = 195 schools/26946 students) using multilevel modeling. Two datasets were merged: (i) survey data from students, including information on schools’ psychosocial environment and subjective IAQ, and (ii) data from school principals, including information on observed indoor air problems. On the student level, school‐related stress, poor teacher–student relationship, and whether the student did not easily receive help from school personnel, were significantly associated with poor subjective IAQ. On the school level, observed indoor air problem (standardized β = ?0.43) and poor teacher–student relationship (standardized β = ?0.22) were significant predictors of poor subjective IAQ. In addition, school‐related stress was associated with poor subjective IAQ, but only in schools without observed indoor air problem (standardized β = ?0.44).  相似文献   

8.
Current knowledge regarding the association between indoor mold exposures and asthma is still limited. The objective of this case–control study was to investigate the relationship between objectively measured indoor mold levels and current asthma among school‐aged children. Parents completed a questionnaire survey of health history and home environmental conditions. Asthma cases had a history of doctor‐diagnosed asthma or current wheeze without a cold in the past 12 months. Controls were age‐ and sex‐matched to cases. Vacuumed dust samples were collected from the child's indoor play area and mattress. Samples were assessed for mold levels and quantified in colony‐forming units (CFU). Sensitization to mold allergens was also determined by skin testing. Being a case was associated with family history of asthma, pet ownership, and mold allergy. Mold levels (CFU/m2) in the dust samples of children's mattress and play area floors were moderately correlated (= 0.56; < 0.05). High mold levels (≥30 000 CFU/m2) in dust samples from play [adjusted odds ratio (aOR) = 2.6; 95% CI: 1.03–6.43] and mattress (aOR) = 3.0; 95% CI: 1.11–8.00) areas were significantly associated with current asthma. In this study high levels of mold are a risk factor for asthma in children.  相似文献   

9.
A nationwide cross‐sectional study of 3335 employees was conducted in 320 offices in Japan to estimate the prevalence of building‐related symptoms (BRSs) and determine the risk factors related to work environment, Indoor Air Quality, and occupational stress. Data were collected through self‐administered questionnaires. The prevalences of general symptoms, eye irritation, and upper respiratory symptoms were 14.4%, 12.1%, and 8.9%, respectively. Multiple logistic regression analyses revealed that eye irritation was significantly associated with carpeting [odds ratio (OR), 1.73; 95% confidence interval (CI), 1.24–2.41], coldness perception (OR, 1.28; 95% CI, 1.13–1.45), and air dryness perception (OR, 1.61; 95% CI, 1.42–1.82). General symptoms were significantly associated with unpleasant odors (OR, 1.37; 95% CI, 1.13–1.65), amount of work (OR, 1.24; 95% CI, 1.06–1.45), and interpersonal conflicts (OR, 1.44; 95% CI, 1.23–1.69). Upper respiratory symptoms were significantly associated with crowded workspaces (OR, 1.36; 95% CI, 1.13–1.63), air dryness perception (OR, 2.07; 95% CI, 1.79–2.38), and reported dustiness on the floor (OR, 1.39; 95% CI, 1.16–1.67). Although psychosocial support is important to reduce and control BRSs, maintaining appropriate air‐conditioning and a clean and uncrowded workspace is of equal importance.  相似文献   

10.
In 2006, area physicians reported increases in upper respiratory symptoms in patients living in U.S. Federal Emergency Management Agency (FEMA)‐supplied trailers following Hurricanes Katrina and Rita. One potential etiology to explain their symptoms included formaldehyde; however, formaldehyde levels in these occupied trailers were unknown. The objectives of our study were to identify formaldehyde levels in occupied trailers and to determine factors or characteristics of occupied trailers that could affect formaldehyde levels. A disproportionate random sample of 519 FEMA‐supplied trailers was identified in Louisiana and Mississippi in November 2007. We collected and tested an air sample from each trailer for formaldehyde levels and administered a survey. Formaldehyde levels among all trailers in this study ranged from 3 parts per billion (ppb) to 590 ppb, with a geometric mean (GM) of 77 ppb [95% confidence interval (CI): 70–85; range: 3–590 ppb]. There were statistically significant differences in formaldehyde levels between trailer types (P < 0.01). The GM formaldehyde level was 81 ppb (95% CI: 72–92) among travel trailers (N = 360), 57 ppb (95% CI: 49–65) among mobile homes (N = 57), and 44 ppb (95% CI: 38–53) among park models (N = 44). Among travel trailers, formaldehyde levels varied significantly by brand. While formaldehyde levels varied by trailer type, all types tested had some levels ≥100 ppb.  相似文献   

11.
Little is known about the health effects of school‐related indoor dampness and microbial exposures. In this study, we investigated dampness and dampness‐related agents in both homes and schools and their association with allergy and respiratory health effects in 330 Danish pupils. Classroom dampness was identified based on technical inspection and bedroom dampness on parents' self‐report. Classroom and bedroom dust was analyzed for seven microbial components. Skin prick testing determined atopic sensitization. Lung function was expressed as z‐scores for forced expiratory volume in one‐second (zFEV1), forced vital capacity (zFVC) and the ratio zFEV1/zFVC using GLI‐2012 prediction equations. The parents reported children's allergies, airway symptoms, and doctor‐diagnosed asthma. High classroom dampness, but not bedroom dampness, was negatively associated with zFEV1 (β‐coef. ?0.71; 95% CI ?1.17 to ?0.23) and zFVC (β‐coef. ?0.52; 95% CI ?0.98 to ?0.06) and positively with wheezing (OR 8.09; 95% CI 1.49 to 43.97). No consistent findings were found between any individual microbial components or combination of microbial components and health outcomes. Among other indoor risk factors, environmental tobacco smoke (ETS) decreased zFEV1 (β‐coef. ?0.22; 95% CI ?0.42 to ?0.02) and zFEV1/zFVCratio (β‐coef. ?0.26; 95% CI ?0.44 to ?0.07) and increased upper airway symptoms (OR 1.66; 95% CI 1.03–2.66). In conclusion, dampness in classrooms may have adverse respiratory health effects in pupils, but microbial agents responsible for this effect remain unknown.  相似文献   

12.
Airborne microorganisms in hospitals have been associated with several hospital-acquired infections (HAIs), and various measures of indoor air quality (IAQ) parameters such as temperature, relative humidity, carbon dioxide (CO2), particle mass concentration, and particle size have been linked to pathogen survival or mitigation of pathogen spread. To investigate whether there are quantitative relationships between the concentration of airborne microorganisms and the IAQ in the hospital environment. Web of Science, Scopus and PubMed databases were searched for studies reporting airborne microbial levels and any IAQ parameter(s) in hospital environments, from database inception to October 2020. Pooled effect estimates were determined via random-effects models. Seventeen of 654 studies were eligible for the meta-analysis. The concentration of airborne microbial measured as aerobic colony count (ACC) was significantly correlated with temperature (r = 0.25 [95% CI = 0.06–0.42], p = 0.01), CO2 concentration (r = 0.53 [95% CI = 0.40–0.64], p ˂ 0.001), particle mass concentration (≤5 µg/m3; r = 0.40 [95% CI = 0.04–0.66], p = 0.03), and particle size (≤5 and ˃5 µm), (r = 0.51 [95% CI = 0.12–0.77], p = 0.01 and r = 0.55 [95% CI = 0.20–0.78], p = 0.003), respectively, while not being significantly correlated with relative humidity or particulate matter of size >5 µm. Conversely, airborne total fungi (TF) were not significantly correlated with temperature, relative humidity, or CO2 level. However, there was a significant weak correlation between ACC and TF (r = 0.31 [95% CI = 0.07–0.52], p = 0.013). Although significant correlations exist between ACC and IAQ parameters, the relationship is not definitive; the IAQ parameters may affect the microorganisms but are not responsible for the presence of airborne microorganisms. Environmental parameters could be related to the generating source, survival, dispersion, and deposition rate of microorganisms. Future studies should record IAQ parameters and factors such as healthcare worker presence and the activities carried out such as cleaning, sanitizing, and disinfection protocols. Foot traffic would influence both the generation of microorganisms and their deposition rate onto surfaces in the hospital environment. These data would inform models to improve the understanding of the likely concentration of airborne microorganisms and provide an alternative approach for real-time monitoring of the healthcare environment.  相似文献   

13.
How building stakeholders (e.g. owners, tenants, operators, and designers) understand impacts of Indoor Air Quality (IAQ) and associated energy costs is unknown. We surveyed 112 stakeholders across the United States to ascertain their perceptions of their current IAQ and estimates of benefits and costs of, as well as willingness to pay for, IAQ improvements. Respondents' perceived IAQ scores correlated with the use of high‐efficiency filters but not with any other IAQ‐improving technologies. We elicited their estimates of the impacts of a ventilation–filtration upgrade (VFU), that is, doubling the ventilation rate from 20 to 40 cfm/person (9.5 to 19 l/s/person) and upgrading from a minimum efficiency reporting value 6 to 11 filter, and compared responses to estimates derived from IAQ literature and energy modeling. Minorities of respondents thought the VFU would positively impact productivity (45%), absenteeism (23%), or health (39%). Respondents' annual VFU cost estimates (mean = $257, s.d. = $496, median = $75 per person) were much higher than ours (always <$32 per person), and the only yearly cost a plurality of respondents said they would pay for the VFU was $15 per person. Respondents holding green building credentials were not more likely to affirm the IAQ benefits of the VFU and were less likely to be willing to pay for it.  相似文献   

14.
Household heating using wood stoves is common practice in many rural areas of the United States (US) and can lead to elevated concentrations of indoor fine particulate matter (PM2.5). We collected 6-day measures of indoor PM2.5 during the winter and evaluated household and stove-use characteristics in homes at three rural and diverse study sites. The median indoor PM2.5 concentration across all homes was 19 µg/m3, with higher concentrations in Alaska (median = 30, minimum = 4, maximum = 200, n = 10) and Navajo Nation homes (median = 29, minimum = 3, maximum = 105, n = 23) compared with Montana homes (median = 16, minimum = 2, maximum = 139, n = 59). Households that had not cleaned the chimney within the past year had 65% higher geometric mean PM2.5 compared to those with chimney cleaned within 6 months (95% confidence interval [CI]: −1, 170). Based on a novel wood stove grading method, homes with low-quality and medium-quality stoves had substantially higher PM2.5 compared to homes with higher-quality stoves (186% higher [95% CI: 32, 519] and 161% higher; [95% CI:27, 434], respectively). Our findings highlight the need for, and complex nature of, regionally appropriate interventions to reduce indoor air pollution in rural wood-burning regions. Higher-quality stoves and behavioral practices such as regular chimney cleaning may help improve indoor air quality in such homes.  相似文献   

15.
To evaluate the potential effect of interaction between breastfeeding and environmental tobacco smoke (ETS) exposure on respiratory health, we studied 31 049 children (aged 2–14 years) from 25 districts of seven cities in northeast China. Parents of the children completed standardized questionnaires that characterized the children's histories of respiratory symptoms and illness, feeding methods, ETS exposure, and other associated risk factors. Breastfeeding was defined as having been mainly breastfed for 3 months or more. The results showed that the association of ETS exposure with childhood respiratory conditions/diseases was modified by breastfeeding, and the association for nonbreastfed children was stronger than that for breastfed children. In particular, for nonbreastfed children, the odds ratios (ORs) for the effect of current ETS exposure asthma was 1.71 (95% CI: 1.43–2.05); however, the OR for breastfed children was 1.33 (95% CI: 1.20–1.48), indicating that the interactions between breastfeeding and current ETS exposure on asthma were statistically significant (P = 0.019). When stratified by school (kindergarten vs. elementary school), breastfeeding was more protective for asthma‐related symptoms among children from kindergarten. In conclusion, this study shows that breastfeeding is associated with smaller associations between ETS exposure and respiratory conditions in children, suggesting that breastfeeding reduces susceptibility to the respiratory effects of ETS.  相似文献   

16.
We studied dampness and mold in homes in relation to climate, building characteristics and socio‐economic status (SES) across Europe, for 7127 homes in 22 centers. A subsample of 3118 homes was inspected. Multilevel analysis was applied, including age, gender, center, SES, climate, and building factors. Self‐reported water damage (10%), damp spots (21%), and mold (16%) in past year were similar as observed data (19% dampness and 14% mold). Ambient temperature was associated with self‐reported water damage (OR=1.63 per 10°C; 95% CI 1.02‐2.63), damp spots (OR=2.95; 95% CI 1.98‐4.39), and mold (OR=2.28; 95% CI 1.04‐4.67). Precipitation was associated with water damage (OR=1.12 per 100 mm; 95% CI 1.02‐1.23) and damp spots (OR=1.11; 95% CI 1.02‐1.20). Ambient relative air humidity was not associated with indoor dampness and mold. Older buildings had more dampness and mold (P<.001). Manual workers reported less water damage (OR=0.69; 95% CI 0.53‐0.89) but more mold (OR=1.27; 95% CI 1.03‐1.55) as compared to managerial/professional workers. There were correlations between reported and observed data at center level (Spearman rho 0.61 for dampness and 0.73 for mold). In conclusion, high ambient temperature and precipitation and high building age can be risk factors for dampness and mold in homes in Europe.  相似文献   

17.
Limited evidence has associated lower ventilation rates (VRs) in schools with reduced student learning or achievement. We analyzed longitudinal data collected over two school years from 150 classrooms in 28 schools within three California school districts. We estimated daily classroom VRs from real‐time indoor carbon dioxide measured by web‐connected sensors. School districts provided individual‐level scores on standard tests in Math and English, and classroom‐level demographic data. Analyses assessing learning effects used two VR metrics: average VRs for 30 days prior to tests, and proportion of prior daily VRs above specified thresholds during the year. We estimated relationships between scores and VR metrics in multivariate models with generalized estimating equations. All school districts had median school‐year VRs below the California VR standard. Most models showed some positive associations of VRs with test scores; however, estimates varied in magnitude and few 95% confidence intervals excluded the null. Combined‐district models estimated statistically significant increases of 0.6 points (P = 0.01) on English tests for each 10% increase in prior 30‐day VRs. Estimated increases in Math were of similar magnitude but not statistically significant. Findings suggest potential small positive associations between classroom VRs and learning.  相似文献   

18.
We investigated the effect of weekends and school holidays on the daily frequency and severity of respiratory and other symptoms among children attending schools with (index) or without (reference) moisture damage in Spain, the Netherlands, and Finland. Throughout 1 year, parents of 419 children with a respiratory condition attending index (n=15) or reference (n=10) primary schools completed three symptom diaries. We assessed associations between lower respiratory tract, upper respiratory tract or allergy, and other symptom scores and school day, weekend, or summer holiday using mixed regression models stratified by country and moisture damage. We evaluated interactions between moisture damage and type of day. We combined country‐specific estimates (incidence rate ratios [IRRs] and 95% confidence interval [CI]) in meta‐analyses. Symptom scores were lower during weekends and holiday. Lower respiratory tract symptoms were statistically significantly less common during holiday with strongest effect in index schools (IRR=0.7; CI=0.6–0.8). Reporting of other symptoms was more reduced during holiday in index (IRR=0.6; CI=0.4–0.9) than in reference (IRR=0.95; CI=0.8–1.2) schools (interaction P<.01). In conclusion, symptoms were less frequent and/or severe during summer holiday and weekends. This pattern was stronger among children attending moisture‐damaged schools, suggesting potential improvement in moisture damage‐related symptoms during school breaks.  相似文献   

19.
The article reports on an experiment which investigated the effect of increased classroom ventilation rate on the performance of children aged 10–12 years. The experiment was executed at two different schools (two classrooms at each school) as a double‐blind 2 × 2 crossover intervention where four different performance tests were used as surrogates for short‐term concentration and logical thinking. Only complete pairs of test responses were included in the within‐subject comparisons of performance, and data were not corrected for learning and fatigue effects. Analysis of the total sample suggested the number of correct answers was improved significantly in four of four performance test, addition (6.3%), number comparison (4.8%), grammatical reasoning (3.2%), and reading and comprehension (7.4%), when the outdoor air supply rate was increased from an average of 1.7 (1.4–2.0) to 6.6 l/s per person. The increased outdoor air supply rate did not have any significant effect on the number of errors in any of the performance tests. Results from questionnaires regarding pupil perception of the indoor environment, reported Sick Building Syndrome symptoms, and motivation suggested that the study classroom air was perceived more still and pupil were experiencing less pain in the eyes in the recirculation condition compared to the fresh air condition.  相似文献   

20.
Most extreme heat studies relate outdoor weather conditions to human morbidity and mortality. In developed nations, individuals spend ~90% of their time indoors. This pilot study investigated the indoor environments of people receiving emergency medical care in New York City, NY, U.S., from July to August 2013. The first objective was to determine the relative influence of outdoor conditions as well as patient characteristics and neighborhood sociodemographics on indoor temperature and specific humidity (N = 764). The second objective was to determine whether cardiovascular or respiratory cases experience hotter and more humid indoor conditions as compared to controls. Paramedics carried portable sensors into buildings where patients received care to passively monitor indoor temperature and humidity. The case–control study compared 338 respiratory cases, 291 cardiovascular cases, and 471 controls. Intuitively, warmer and sunnier outdoor conditions increased indoor temperatures. Older patients who received emergency care tended to occupy warmer buildings. Indoor‐specific humidity levels quickly adjusted to outdoor conditions. Indoor heat and humidity exposure above a 26 °C threshold increased (OR: 1.63, 95% CI: 0.98–2.68, P = 0.056), but not significantly, the proportion of respiratory cases. Indoor heat exposures were similar between cardiovascular cases and controls.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司    京ICP备09084417号-23

京公网安备 11010802026262号