1.
The performance of a modified Danfoss 50 mm diameter electromagnetic flowmeter has been investigated when installed downstream from three different pipe diameters—50 mm, 55 mm and 45 mm. The effects of a 3 mm misalignment of the flowmeter, in both the vertical and horizontal planes, with respect to each of the three upstream pipe diameters has also been identified. The largest percentage errors are reported for the 45 mm upstream diameter pipe, with the flowmeter misaligned by 3 mm in the horizontal plane. The vertical and horizontal mean velocity and root-mean-square velocity profiles, measured within the flowmeter using laser Doppler anemometry, show significant variations in comparison with the ideal, fully developed profiles.  相似文献   

2.
This research investigates the effects of flow pattern and salinity of oil-water two-phase flow on water holdup measurement using a conductance method. Firstly, vertical upward oil-water two-phase flow experiment is conducted in a 20 mm inner diameter (ID) pipe, in which the salinities of aqueous solutions are set as 151 ppm, 1003 ppm, 2494 ppm and 4991 ppm respectively. Experimental water-cut and mixture velocity are set as 80–100% and 0.0184–0.2576 m/s. In the experiment, three different flow patterns, i.e., dispersed oil-in-water slug flow (D OS/W), dispersed oil-in-water flow (D O/W) and very fine dispersed oil-in-water flow (VFD O/W) are observed and recorded by a high speed camera. Meanwhile, we collect the response of Vertical Multiple Electrode Array (VMEA) conductance sensor excited by a sine voltage signal. The result shows that, for VFD O/W, the water holdup from VMEA sensor shows a satisfied agreement with that of quick closing valve (QCV) method under certain salinities, i.e., 1003 ppm as well as 2494 ppm. For D OS/W flow and D O/W flow characterized by dispersed oil droplets with various sizes, considerable deviations of water holdup between VMEA sensor and QCV method under four kinds of salinity aforementioned are presented. Afterward, according to experimental analysis along with theoretical deviation, it is concluded that the deviation of the measurement system reaches its minimum when reference resistance in the measurement circuit and salinity of the aqueous solution satisfy constraint conditions, and the accuracy of water holdup using the conductance method can be improved through adjusting reference resistance to match the salinity of water phase. Finally, the recurrence plot algorithm is utilized to identify typical flow patterns mentioned above and it shows satisfied results on comprehending the discrepancies among different flow patterns, demonstrating that the recurrence plot algorithm can be effectively applied in flow pattern identification regarding oil-water flows.  相似文献   

3.
This paper presents a runout measurement method and a novel finite grouping method to predict and optimize the rotational angle and translational displacement of butting pipes to minimize pipe wall misalignment (PWM). This study develops a method to minimize the PWM of the pipes excluding the positions of welding seams. In this method, the measurement data are divided into finite groups and the criteria are created to identify the positions of welding seams and eliminate the effect of the welding seams. Finally, the rotational angle and translational displacement of the butting pipes are optimized to minimize the PWM. A butting machine is designed to implement this method. The machine is benchmarked by a standard smooth pipe to minimize system errors. Three butting experiments have been performed with welded pipes of diameter 406 mm. The comparison shows that the computation results agree with the experimental results very well. The maximum PWMs in three experiments are less than 1.87 mm, which satisfies the butting requirements, that is, a PWM of less than 2.0 mm. Then, the uncertainties of the measurement results are discussed.  相似文献   

4.
This paper proposes a design method for cross-spring pivots with quasi-constant rotational stiffness in the field of unbalanced moment measurement. To achieve high precision measurement of unbalance moment, the relationship between instrument sensitivity and the rotational stiffness of the cross-spring pivot is revealed. In order to eliminate the impacts of payload changes on instrument sensitivity, the relationship between geometric parameters and the rotational stiffness of the pivot is studied. Further, cross-spring pivots with quasi-constant rotational stiffness are designed as the rotation unit of a static balancing instrument, while the center shift of pivot takes the minimum value. Certain amount of unbalance moments is measured by the instrument. Experimental studies of the instrument show that the maximum measurement errors of unbalance moments 0.162 g mm, 0.319 g mm and 1.300 g mm are 0.068 g mm, 0.086 g mm and 0.053 g mm, respectively, when the payload ranges from 0 g to 7000 g. The instrument can achieve a relatively high precision measurement and the instrument sensitivity is almost not affected by the changes of payloads. The effectiveness of the method and the stiffness property of the pivot are verified by the experiments. So this kind of pivot has good prospects in unbalance moment measurement.  相似文献   

5.
In this paper, on an experimental facility, the measurement characteristics of a diameter 50 mm dual triangulate bluff body vortex flowmeter in steady flow and oscillatory flow were investigated. Then, the Hilbert Huang Transformation (HHT) method was used to assess the anti-interference performances and the vortex street stability in oscillatory flow for the dual triangulate bluff body vortex flowmeter and a single bluff body vortex flowmeter. Offline simulation was carried out on the anti-interference performances of the dual triangulate bluff body vortex flowmeter signal noise in oscillatory flow by the method of the EMD-scales filter. The major findings are: (a) in most case, the EMD-scales filter may be as good at de-noising effect for the dual bluff body vortex flowmeter in oscillatory flow than that for the single bluff body vortex flowmeter in oscillatory flow. The vortex street stability in oscillatory flow for the dual bluff body is similar to that for the single bluff body. (b) In some special case, the EMD-scales filter is unable to play a better de-nosing role for the dual bluff body vortex flowmeter in oscillatory flow. The invalid condition of the EMD-scales filter for the dual bluff body vortex flowmeter in oscillatory flow is different to that of the single bluff body vortex flowmeter and it was advanced in this paper. (C) The vortex street stability for the dual bluff body vortex flowmeter is better than that for the single bluff body vortex flowmeter.  相似文献   

6.
Within the framework of a research project regarding investigations on a high-pressure Coriolis mass flow meter (CMF) a portable flow test rig for traceable calibration measurements of the flow rate (mass - and volume flow) in a range of 5 g min−1 to 500 g min−1 and in a pressure range of 0.1 MPa to 85 MPa was developed. The measurement principle of the flow test rig is based on the gravimetrical measuring procedure with flying-start-and-stop operating mode. Particular attention has been paid to the challenges of temperature stability during the measurements since the temperature has a direct influence on the viscosity and flow rate of the test medium. For that reason the pipes on the high-pressure side are double-walled and insulated and the device under test (DUT) has an enclosure with a separate temperature control. From the analysis of the first measurement with tap water at a temperature of 20 °C and a pressure of 82.7 MPa an extensive uncertainty analysis has been carried out. It was found that the diverter (mainly due to its asymmetric behaviour) is the largest influence factor on the total uncertainty budget. After a number of improvements, especially concerning the diverter, the flow test rig has currently an expanded measurement uncertainty of around 1.0% in the lower flow rate range (25 g min−1) and 0.25% in the higher flow rate range (400 g min−1) for the measurement of mass flow. Additional calibration measurements with the new, redesigned flow test rig and highly viscous base oils also indicated a good agreement with the theoretical behaviour of the flow meter according to the manufacturers׳ specifications with water as test medium. Further improvements are envisaged in the future in order to focus also on other areas of interest.  相似文献   

7.
Oil-in-water two-phase flows are often encountered in the upstream petroleum industry. The measurement of phase flow rates is of particular importance for managing oil production and water disposal and/or water reinjection. The complexity of oil-in-water flow structures creates a challenge to flow measurement. This paper proposes a new method of two-phase flow metering, which is based on the use of dual-modality system and multidimensional data fusion. The Electrical Resistance Tomography system (ERT) is used in combination with a commercial off-the-shelf Electromagnetic Flow meter (EMF) to measure the volumetric flow rate of each constituent phase. The water flow rate is determined from the EMF with an input of the mean oil-fraction measured by the ERT. The dispersed oil-phase flow rate is determined from the mean oil-fraction and the mean oil velocity measured by the ERT cross-correlation velocity profiling. Experiments were carried out on a vertical upward oil-in-water pipe flow, 50 mm inner-diameter test section, at different total liquid flow rates covering the range of 8–16 m3/hr. The oil and water flow rate measurements obtained from the ERT and the EMF are compared to their respective references. The accuracy of these measurements is discussed and the capability of the measurement system is assessed.  相似文献   

8.
Industrial applications involving pulsed ultrasound instrumentation require complete non-invasive setups due to high temperatures, pressures and possible abrasive fluids. Recently, new pulser-receiver electronics and a new sensor unit were developed by Flow-Viz. The complete sensor unit setup enables non-invasive Doppler measurements through high grade stainless steel. In this work a non-invasive sensor unit developed for one inch pipes (22.5 mm ID) and two inch pipes (48.4 mm ID) were evaluated. Performance tests were conducted using a Doppler string phantom setup and the Doppler velocity results were compared to the moving string target velocities. Eight different positions along the pipe internal diameter (22.5 mm) were investigated and at each position six speeds (0.1–0.6 m/s) were tested. Error differences ranged from 0.18 to 7.8% for the tested velocity range. The average accuracy of Doppler measurements for the 22.5 mm sensor unit decreased slightly from 1.3 to 2.3% across the ultrasound beam axis. Eleven positions were tested along the diameter of the 48.4 mm pipe (eight positions covered the pipe radius) and five speeds were tested (0.2–0.6 m/s). The average accuracy of Doppler measurements for the 48.4 mm sensor unit was between 2.4 and 5.9%, with the lowest accuracy at the point furthest away from the sensor unit. Error differences varied between 0.07 and 11.85% for the tested velocity range, where mostly overestimated velocities were recorded. This systematic error explains the higher average error difference percentage when comparing the 48.4 mm (2.4–5.9%) and 22.5 mm (1.3–2.3%) sensor unit performance. The overall performance of the combined Flow-Viz system (electronics, software, sensor) was excellent as similar or higher errors were typically reported in the medical field. This study has for the first time validated non-invasive Doppler measurements through high grade stainless steel pipes by using an advanced string phantom setup.  相似文献   

9.
The concentration measurement of pulverized coal in a pneumatic pipeline is a challenging issue in power plant. A thermal probe manufactured with abrasion-proof steel was developed for coal concentration measurement in such a situation. The probe generates 15 W of heat. This method is based on the heat transfer between the thermal probe and the gas–solid two-phase flow. Experiments were conducted in a horizontal pneumatic pipeline to assess the accuracy of the thermal probe, where the gas was air and the solid was pulverized coal with mean diameter of 65 µm. The wall temperature of the thermal probe was found to be dependent on both coal powder concentration and air velocity. A new heat transfer correlation was proposed in terms of the modified Reynolds and Nusselt numbers for the gas–solid two-phase flow across the thermal probe. In the range of coal powder concentration from 0.1 to 0.65 kg/kg, the standard deviation is 0.01 kg/kg for the thermal probe. The thermal probe has potential application for concentration measurement of pulverized coal in the pneumatic pipelines of power plants.  相似文献   

10.
LNE has ability to calibrate gas micro-flow rates using the dilution method for nitrogen flow rates in the range from 2 µg/s to 200 µg/s or helium ones in the range 0.75–30 µg/s. In addition, a primary constant pressure flowmeter for leak rate measurements from 0.05 µg/s to 35 µg/s is also available. This equipment will be used to validate the dilution method below 30 µg/s. In order to compare these reference facilities, LNE is developing a micro-flow transfer standard (µFTS) in collaboration with ATEQ France, a manufacturer of control equipment for leak testing. The flowmeter consists mainly of an array of three stainless steel capillaries designed to cover the ranges from 0.035 µg/s to 0.35 µg/s, 0.35 µg/s to 3.5 µg/s and 3.5 µg/s to 35 µg/s for nitrogen (0.1–100 ml/h). A dynamic model of the µFTS determines the mass flow rate from the input pressure, the differential pressure of the capillary, the gas temperature, viscosity and density and the length and radius of the capillary. A comparison of both reference methods is carried out with the µFTS from 0.35 µg/s to 35 µg/s.  相似文献   

11.
This paper presents the design and calibration of an ISO non-compliant orifice plate flowmeter whose intended use is for respiratory function measurements in the bidirectional air flow range ±9 L/min.The novelty of the proposed sensor consists of a plate beveled in both upstream and downstream sides: a symmetrical geometry is adopted in order to perform bidirectional measurements of flow rate. A mathematical model is introduced to quantify the influence of temperature on the sensor output. Four different positions of the pressure static taps are evaluated in order to maximize bidirectionality. An index is also introduced in order to quantitatively estimate the anti-symmetry of the sensor's response curve.Trials are carried out to evaluate the influence on sensor output of air temperatures (22 °C, 30 °C and 37 °C) at different values of relative humidity (5%, 55% and 85%). Experimental data show a quite good agreement with the theoretical model (R2>0.98 in each condition).The influence of air temperature on the sensor output is minimized by introducing a correction factor based on the theoretical model leading to measurement repeatability better than 2% in overall range of calibration. The mean sensitivity in the calibration range is about 2 kPa L−1·min allowing to obtain a sensor discrimination threshold lower than 0.2 L/min in both directions. The time constant of the whole measurement system, equal to 2.40±0.03 ms, leads to a bandwidth up to 80 Hz making the sensor suitable for respiratory function measurements.  相似文献   

12.
The present paper describes a moving permanent magnet linear synchronous motor (MPM LSM) that can move with an acceleration above 100 G (=980 m/s2), and is also capable of high-precision and high-speed positioning. The MPM LSM consists of a mover including permanent magnets and a double-sided electromagnet stator. It can produce a thrust of 4.56 × 103 N and has a working range wider than 1 m. The MPM LSM mover is improved for light weight and is driven using a suitable phase lead for flux weakening. The combination of the improved mover and the suitable phase lead provides motion at an acceleration above 100 G and a velocity above 12 m/s. The positioning characteristics of the improved MPM LSM are examined using a controller with two suitable phase lead functions. The control system shows a positioning accuracy and a positioning resolution of 500 nm, which is similar to the vibration amplitude of the sensor output in open loop. In 300-mm step positioning, the improved MPM LSM shows an acceleration above 660 m/s2 and a velocity above 8.3 m/s. It takes less than 101 ms to reduce the positioning error to less than 5 μm. The temperature rise during positioning is also examined experimentally. Continuous positioning for longer than 30 minutes increases the temperature of the MPM LSM, but by less than 6 °C.  相似文献   

13.
Large-scale rotors in the paper and steel industry are called rolls. Rolls are reground at regular intervals and roundness measurements are made throughout the machining process. Measurement systems for roundness and diameter variation of large rolls (diameter <2000 mm) are available on the market, and generally use two to four sensors and a roundness measurement algorithm. These methods are intended to separate roundness of the rotor from its movement. The hybrid four-point method has improved accuracy, even for harmonic component amplitudes. For reliable measurement results, every measurement should be traceable with an estimation of measurement uncertainty. In this paper, the Monte-Carlo method is used for uncertainty evaluation of the harmonic components of the measured roundness profile under typical industrial conditions. According to the evaluation, the standard uncertainties for the harmonic amplitudes with the hybrid method are below 0.5 μm for the even harmonics and from 1.5 μm to 2.5 μm for the odd harmonics, when the standard uncertainty for the four probes is 0.3 μm each. The standard uncertainty for roundness deviation is 3.3 μm.  相似文献   

14.
Wire-mesh sensors (WMS), developed at HZDR [4], [13], are widely used to visualize two-phase flows and measure flow parameters, such as phase fraction distributions or gas phase velocities quantitatively and with a very high temporal resolution. They have been extensively applied to a wide range of two-phase gas–liquid flow problems with conducting and non-conducting liquids. However, for very low liquid loadings, the state of the art data analysis algorithms for WMS data suffer from the comparably low spatial resolution of measurements and from boundary effects, caused by e.g. flange rings – especially in the case of capacitance type WMS. In the recent past, diverse studies have been performed on two-phase liquid–gas stratified flow with low liquid loading conditions in horizontal pipes at the University of Tulsa. These tests cover oil–air flow in a 6-inch ID pipe and water–air flow in a 3-inch ID pipe employing dual WMS with 32×32 and 16×16 wires, respectively. For oil–air flow experiments, the superficial liquid and gas velocities vary between 9.2 m/s≤νSG≤15 m/s and 0.01 m/s≤νSL≤0.02 m/s, respectively [2]. In water–air experiments, the superficial liquid and gas velocities vary between 9.1 m/s≤νSG≤33.5 m/s and 0.03 m/s≤νSL≤0.2 m/s, respectively [17], [18]. In order to understand the stratified wavy structure of the flow, the reconstruction of the liquid–gas interface is essential. Due to the relatively low spatial resolution in the WMS measurements of approximately 5 mm, the liquid–gas interface recognition has always an unknown uncertainty level. In this work, a novel algorithm for refined liquid–gas interface reconstruction is introduced for flow conditions where entrainment is negligible.  相似文献   

15.
The number of slug units that traverses a particular point at a given time within a defined pipe cross-section is known as slug frequency. The behaviour of this critical parameter for two-phase flow in high viscosity oils is significantly different from those of conventional oils (of less than 1 Pa s). In this experimental investigation, new data on slugging frequency in high viscosity oil-gas flow are reported. Scaled experiments were carried out using a mixture of air and mineral oil in a 17 m long horizontal pipe of 0.0762 m ID. A high-speed Gamma Densitometer of frequency of 250 Hz was used for data acquisition over a time interval of 30 s. For the range of flow conditions investigated, increase in oil viscosity was observed to strongly influence the slug frequency. Comparison of the present data with prediction models available in the literature revealed discrepancies. A new correlation incorporating the effect of viscosity on slug frequency has been proposed for horizontal flow. The proposed correlation will improve the prediction of slug frequency in high viscosity oils.  相似文献   

16.
A new test facility has been constructed for the National Metrology Institute of Japan (NMIJ) and the National Institute of Advanced Industrial Science and Technology (AIST) for calibration of feedwater flowmeters used in nuclear power stations at Reynolds numbers of up to 18 million. This very large Reynolds number is achieved in a 600 mm pipe at a flowrate of 3.33  m3/s (12,000  m3/h) and a water temperature of 70  °C. This calibration facility consists of a circulation loop with four pumps and four reference flowmeter sets, a prover system, a heating and cooling unit, and other components. The expanded uncertainty of this facility is 0.077%. The present paper describes, in detail, the new facility, the calibration method of the reference flowmeter, experiments for flow field, uncertainty estimation, and the results of an example calibration.  相似文献   

17.
The measurement principle of vortex flowmeter is based on von Karman vortex shedding phenomenon. Frequency of vortices, behind the bluff body, is proportional to the mean flow velocity. There are different ways of detection of vortices, and different sensors are used (presser sensors, capacitive sensors, thermo-resistance sensors, ultrasonic sensors, etc.). Proposed method to vortex identification, presented in this paper is based on simultaneous detection of pair of vortices with opposite circulation, by means of two pairs of ultrasonic transducers. A beam of ultrasound, from ultrasonic transmitter to ultrasonic receiver is transmitted perpendicularly to the vortex street. The received ultrasonic signal is amplitude and phase modulated. Frequency of demodulated signal is equal to the frequency of vortices. This technique allows a number of advantages comparing to conventional solutions: reduction, or elimination of noises caused by installation vibration and disturbances in the flow, higher sensor sensitivity, which as a result leads to a possibility of a reduction of the bluff body size, i.e. reduction of the pressure drop on the flow meter, increase of the measurement range in the low flow region, the possibility of redundant operation of the flow meter, reduced measurement uncertainty, instrument technology improvements, improved reliability of the instrument, assured improved statement of complete uncertainty contributions, improved metrology of the equipment as such and calibration procedures that contribute to measuring capabilities etc. For experimental testing a prototype vortex flowmeter of a nominal inner diameter (ID) 50 mm is developed. A cylindrical bluff body for vortex shedding is used. Ultrasonic transducers based on piezo-crystal PZT-5A, inserted in the wall of the vortex meter casing are utilized. The testing of prototype ultrasonic vortex flowmeter is realized on the calibration station on the water. The results at the testing point to the possibility of measuring flow of liquid fluids at velocities less than 0.5 m/s, with an uncertainty better than ±1%.  相似文献   

18.
The critical flow nozzle is widely used to calibrate flowmeters in gas flow measurement. Its use requires the critical flow factor, C*, a parameter dependent upon the thermophysical properties of the gas at the nozzle throat, and the upstream temperature and pressure. This paper presents C* values for four calibration gases (air, argon, nitrogen and methane), calculated from the most recent reference quality equations of state, over a wider range of temperature and pressure than previously available, 200–600 K and up to 20 MPa. In addition, a new empirical equation has been developed to represent the calculated values accurately, thus eliminating the need for complex calculations or interpolations from tables.  相似文献   

19.
Two miniaturized liquid film sensors (MLFS) based on electrical conductance measurement have been developed and tested. The sensors are non-intrusive and produced with materials and technologies fully compatible and integrable with standard microfluidics. They consist of a line of 20 electrodes with a purpose-designed shape, flush against the wall, covering a total length of 5.00 and 6.68 mm. The governing electronics achieve 10 kHz of time resolution. The electrode spacing of the two sensors is 230 μm and 330 μm, which allows measurements of liquid films up to 150 μm and 400 μm for sensors MLFSA and MLFSB, respectively. The sensor characteristics were obtained by imposing static liquid films of known thickness on top of the actual sensor. Further dynamic measurements of concurrent air-water flow in a horizontal microchannel were performed. The line of electrodes is placed across the flow direction with an angle of 3.53° from the direction of flow, allowing for a spatial resolution perpendicular to the flow of 14.2 μm for sensor MLFSA and 20.5 μm for sensor MLFSB. The high time and spatial resolution allows for fast and accurate detection of the presence of bubbles, and even measurement of film thickness and bubble velocity. Further information, such as the bubble shape, can be gathered based on the shape of the liquid layer underneath the bubble, which is particularly important for heat transfer studies in microchannels.  相似文献   

20.
A miniature-positioning device with a large stroke motion has attracted more and more attentions in these years because of the intensive development in precision engineering. In this paper, we have achieved the large stroke actuating and the high precision positioning, as well as realized a multi-degree-of-freedom in-plane motion using the developed Galfenol impact drive mechanism (IDM) actuator. In order to enhance the system robustness, two pieces of U-shape Galfenol (iron–gallium alloy) have been employed as the driving elements with a bias magnetic field contributed by a permanent magnet to generate the swing motion that amplifies the propelling inertia force. The current amplitude modulation has been applied in the precision positioning of the actuator under the quasi-static condition because of the motion step-size fineness. The results show that the actuator is able to achieve a sub-micrometer positioning accuracy that has reached the measurement limit of our setup. Meanwhile, the frequency modulation method has been explored in the large stroke actuation with a high motion speed. We have found out that this design is capable of achieving an accurate positioning without the frequency modulation because of the intrinsic fine step-size of the actuator. In addition, a rectangular in-plane motion has been realized with the image-based control for the multi-degree-of-freedom positioning. The actuator has an inductive impedance with a resistance of 3.796 Ω and an inductance of 0.4697 mH. Under the present driving ratings, the power consumption is smaller than 1.97 W while the reactive power can be ignored. Moreover, the experimental load analysis indicates that the design can achieve a maximum carry-load-to-weight ratio of 6.5.  相似文献   