1.
This paper investigates the seismic response control of a 20-story nonlinear benchmark building with a new recentering variable friction device (RVFD). The RVFD combines energy dissipation capabilities of a variable friction damper (VFD) with the recentering ability of shape memory alloy (SMA) wires. The VFD that is the first subcomponent of the hybrid device consists of a friction generation unit and piezoelectric actuators. The clamping force of the VFD can be adjusted according to the current level of ground motion by adjusting the voltage level of piezoelectric actuators. SMA wires that exhibit a unique hysteretic behavior and full shape recovery after experiencing large strains is the second subcomponent of the hybrid device. Numerical simulations of a seismically excited 20-story benchmark building are conducted to evaluate the performance of the hybrid device. A continuous hysteretic model is used to capture frictional behavior of the VFD and a neuro-fuzzy model is employed to describe highly nonlinear behavior of the SMA components of the hybrid device. A fuzzy logic controller is developed to adjust the voltage level of VFDs for favorable performance in an RVFD hybrid application. Results show that the RVFD modulated with a fuzzy logic control strategy can effectively reduce interstory drifts and permanent deformations without increasing acceleration response of the benchmark building for most cases. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

2.
基于抑制升船结构顶部厂房地震鞭梢效应的目的,本文提出了升船结构顶部厂房屋盖MR智能隔震模糊控制的思想。文中,在建立屋盖智能隔震升船结构计算力学模型的基础上,建立了屋盖MR智能隔震系统对升船结构顶部厂房地震反应模糊控制的设计计算方法。文中并以中国某大坝巨型升船结构为背景,设计了屋盖MR智能隔震系统对升船结构顶部厂房地震反应模糊控制的控制系统。仿真分析和对MR阻尼器的参数研究表明,安装合适的屋盖MR智能隔震系统并采用模糊控制策略能有效地抑制具有不确定参数升船结构顶部厂房地震反应的鞭梢效应,且模糊控制器能保持较好的稳定性能。  相似文献   

3.
Passive supplemental damping in a seismically isolated structure provides the necessary energy dissipation to limit the isolation system displacement. However, damper forces can become quite large as the passive damping level is increased, resulting in the requirement to transfer large forces at the damper connections to the structure which may be particularly difficult to accommodate in retrofit applications. One method to limit the level of damping force while simultaneously controlling the isolation system displacement is to utilize an intelligent hybrid isolation system containing semi-active dampers in which the damping coeffic ient can be modulated. The effectiveness of such a hybrid seismic isolation system for earthquake hazard mitigation is investigated in this paper. The system is examined through an analytical and computational study of the seismic response of a bridge structure containing a hybrid isolation system consisting of elastomeric bearings and semi-active dampers. Control algorithms for operation of the semi-active dampers are developed based on fuzzy logic control theory. Practical limits on the response of the isolation system are considered and utilized in the evaluation of the control algorithms. The results of the study show that both passive and semi-active hybrid seismic isolation systems consisting of combined base isolation bearings and supplemental energy dissipation devices can be beneficial in reducing the seismic response of structures. These hybrid systems may prevent or significantly reduce structural damage during a seismic event. Furthermore, it is shown that intelligent semi-active seismic isolation systems are capable of controlling the peak deck displacement of bridges, and thus reducing the required length of expansion joints, while simultaneously limiting peak damper forces. Copyright © 1999 John Wiley & Sons, Ltd.  相似文献   

4.
A semi‐active fuzzy control strategy for seismic response reduction using a magnetorheological (MR) damper is presented. When a control method based on fuzzy set theory for a structure with a MR damper is used for vibration reduction of a structure, it has an inherent robustness, and easiness to treat the uncertainties of input data from the ground motion and structural vibration sensors, and the ability to handle the non‐linear behavior of the structure because there is no longer the need for an exact mathematical model of the structure. For a clipped‐optimal control algorithm, the command voltage of a MR damper is set at either zero or the maximum level. However, a semi‐active fuzzy control system has benefit to produce the required voltage to be input to the damper so that a desirable damper force can be produced and thus decrease the control force to reduce the structural response. Moreover, the proposed control strategy is fail‐safe in that the bounded‐input, bounded‐output stability of the controlled structure is guaranteed. The results of the numerical simulations show that the proposed semi‐active control system consisting of a fuzzy controller and a MR damper can be beneficial in reducing seismic responses of structures. Copyright © 2004 John Wiley & Sons, Ltd.  相似文献   

5.
In most of the research work on structural vibration control only two‐dimensional plane structural modelling has been considered, although only a few practical building structures can be modelled as planar structures. Therefore, these methods are not directly applicable to the majority of the practical building structures. This paper discusses the design of a multiobjective optimal fuzzy logic controller (FLC) driven hybrid mass damper (HMD) system for seismically excited torsionally coupled building structures. Floor acceleration and velocity information have been used as feedback to the fuzzy logic controller. A three branch tournament Genetic Algorithm has been used for the multiobjective optimal design of the FLC driven HMD system, where the minimization of the non‐dimensionalized peak displacement, acceleration and rotation of the structure about its vertical axis, have been as the three objective functions. The proposed multiobjective optimal fuzzy logic controller has been verified for an example problem reported in the literature. This HMD system consists of four HMDs arranged in such a way that the system can control the torsional mode of vibration effectively in addition to the flexure modes of vibration. Copyright © 2002 John Wiley & Sons, Ltd.  相似文献   

6.
Adaptive base-isolation of civil structures using variable amplification   总被引:1,自引:0,他引:1  
Semi-active dampers are used in base-isolation to reduce the seismic response of civil engineering structures. In the present study, a new semi-active damping system using variable amplification will be investigated for adaptive baseisolation. It uses a novel variable amplification device (VAD) connected in series with a passive damper. The VAD is capable of producing multiple amplification factors, each corresponding to a different amplification state. Forces from the damper are amplified to the structure according to the current amplification state, which is selected via a semi-active control algorithm specifically tailored to the system's tmique damping characteristics. To demonstrate the effectiveness of the VAD-damper system for adaptive base-isolation, numerical simulations are conducted for three and seven-story base-isolated buildings subject to both far and near-field ground motions. The results indicate that the system can achieve significant reductions in response compared to the base-isolated buildings with no damper. The proposed system is also found to perform well compared to a typical semi-active damper.  相似文献   

7.
近断层地震动中长周期、短持时和高能量的加速度脉冲将对高层摩擦摆基础隔震结构的减震性能产生不利影响,考虑土-结构相互作用(SSI效应)后的隔震结构将产生动力耦合效应,可能进一步放大隔震结构地震响应。为此,通过一幢框架-核心筒高层摩擦摆基础隔震结构的非线性地震响应分析,考察近断层脉冲型地震动作用下框架-核心筒摩擦摆基础隔震结构的层间位移角、楼层加速度和隔震层变形等响应规律,揭示隔震体系的损伤机理。基于集总参数SR (sway-rocking)模型,分析不同场地类别与不同地震动类型对隔震体系动力响应影响规律。结果表明:高层摩擦摆基础隔震结构在近断层脉冲型地震动作用下的减震效果相比普通地震动减震效果变差,楼层剪力、层间位移角和隔震层变形等超越普通地震动作用下的1.5倍;对于Ⅲ和Ⅳ类场地类别,考虑SSI效应使隔震结构的地震响应进一步放大,弹塑性层间位移角随着土质变软增大尤为明显。  相似文献   

8.
摩擦摆基础隔震结构多维地震反应分析   总被引:2,自引:0,他引:2  
对摩擦摆基础隔震结构进行了单向、双向和三向地震反应对比分析,表明考虑双向水平地震动时摩擦摆基础隔震结构的支座位移增大,而结构的加速度和楼层剪力减小,其中对支座位移和结构加速度影响较大;考虑竖向地震动时摩擦摆基础隔震结构的支座位移略有减小,而结构的加速度和楼层剪力增大,其中对结构加速度影响较大.因而,在进行摩擦摆基础隔震结构地震反应分析时,应考虑多维地震动的影响.  相似文献   

9.
In this study friction pendulum system (FPS) bearings and precast-prestressed pile (PPP) isolators are considered as base isolation devices for a Chilean confined masonry house. The house is numerically modeled using a multiple degree-of-freedom approach that is calibrated with experimental data. Dynamic behavior of the FPS and PPP isolators is simulated using analytical formulations based on laboratory testing. Optimization of the isolators is performed using an earthquake that is generated to match the design spectrum for the house based on Chilean seismic code. A non-dominated sorting genetic algorithm (NSGA-II) is applied to carry out the optimization. Seismic response of the base-isolated structure subjected to a suite of ground motions is compared to the performance of the traditionally-constructed structure by means of several performance indices (PIs). Numerical simulations indicate that the PPP isolation system is more effective in reducing the base and structural shear, interstory drift, and floor acceleration of the structure than the FPS isolation system, although both systems result in substantial reductions of the response.  相似文献   

10.
滚动FPS和MR阻尼器混合基础动力学模型及仿真   总被引:2,自引:0,他引:2  
本文中作者将新型双磙子FPS系统的动力学方程推广到由滚动FPS和MR阻尼器组成的混合隔震基础系统,得到了更便于应用的水平分量形式的运动微分方程,并将与FPS有关的力和MR阻尼力处理成力源项,构造了可以方便地考虑不同上部结构形式的MATLAB/SIMULINK仿真模型。采用RD-1005型MR阻尼器和模糊逻辑控制器,在两个典型的地震输入情况下对混合系统进行了振动控制仿真。仿真结果表明,本文建立的混合隔震基础系统的动力学模型是正确和精确的,直接利用动力学模型进行前向计算可避免附加的模型误差且计算效率高,而仿真模型中将不同的力源由分开的块组成,使得仿真设计非常方便快捷。  相似文献   

11.
摩擦摆基础隔震结构双向地震反应分析   总被引:6,自引:0,他引:6  
采用双向耦合力学模型模拟摩擦摆支座的双向耦合效应,对摩擦摆基础隔震结构进行了单向和双向地震反应对比分忻,分析表明在双向地震作用下结构各层的加速度反应较小,隔震层的层间位移较大,而上部结构的层间位移较小,并且在双向地震作用下,支座的最大位移明显大于单向地震作用时的支座最大位移,因而应考虑双向地震作用对摩擦摆基础隔震结构地震反应和隔震支座性能的影响。  相似文献   

12.
The Friction Pendulum System (FPS) isolator is commonly used as a base isolation system in buildings. In this paper, a new tunable FPS (TFPS) isolator is proposed and developed to act as a semi‐active control system by combining the traditional FPS and semi‐active control concept. Theoretical analysis and physical tests were carried out to investigate the behavior of the proposed TFPS isolator. The experimental and theoretical results were in good agreement, both suggesting that the friction force of the TFPS isolator can be tuned to achieve seismic isolation of the structure. A series of numerical simulations of a base‐isolated structure equipped with the proposed TFPS isolator and subjected to earthquake ground motions were also conducted. In the analyses, the linear quadratic regulator (LQR) method was adopted to control the friction force of the proposed TFPS, and the applicability and effectiveness of the TFPS in controlling the structure's seismic responses were investigated. The simulation results showed that the TFPS can reduce the displacement of the isolation layer without significantly increasing the floor acceleration and inter‐story displacement of the superstructure, confirming that the TFPS can effectively control a base‐isolated structure under earthquake ground motions.  相似文献   

13.
近断层地震动脉冲特性在2个水平分量上具有差异,采用平方和开方法分析了近断层脉冲地震动双向地震作用下基础隔震结构和组合隔震结构的隔震层位移,并与近断层脉冲单向地震作用进行了对比分析,结果表明:若仅地震动加速度峰值大的分量或2个方向分量均存在明显速度脉冲,则产生的隔震层位移大于单向地震动;若仅地震动加速度峰值小的分量存在明...  相似文献   

14.
Seismic fragility curves for fixed-base and base-isolated liquid storage tanks are developed under non-stationary earthquakes, and their seismic performance are compared. The correlation between different earthquake intensity measure (IM) parameters and peak response quantities of the base-isolated liquid storage tanks are investigated. The failure criteria are chosen based on (1) the elastic buckling strength of the tank wall, which is defined in terms of critical base shear and critical overturning moment, and (2) in terms of the critical isolation displacement. The uncertainty involved is considered in the earthquake characteristics. Non-stationary earthquake ground motions are generated using Monte Carlo (MC) simulation. Influence of the isolator characteristic parameters and modeling approaches on the seismic fragility of the base-isolated liquid storage tanks is also investigated. Peak ground acceleration is found to be the well correlated IM parameter with the peak response quantities of the base-isolated liquid storage tanks. Substantial decrease in the seismic fragility of the base-isolated liquid storage tanks is observed as compared to the fixed-base tanks. Significant influence of the isolator characteristic parameters on the seismic fragility of the base-isolated liquid storage tanks are reported in the present study.  相似文献   

15.
为改善近断层地震动作用下隔震桥梁结构的抗震性能,基于Benchmark结构振动控制问题,研究附加黏滞阻尼器、磁流变(MR)阻尼器的组合隔震策略.非线性动力分析过程中,优化了黏滞阻尼器的阻尼系数和速度指数,并设计了分散模糊控制器来确定施加给磁流变阻尼器的电压.研究结果表明:采用黏滞阻尼器和磁流变阻尼器可提高隔震桥梁结构在...  相似文献   

16.
Long-period pulses in near-field earthquakes lead to large displacements in the base of isolated structures.To dissipate energy in isolated structures using semi-active control,piezoelectric friction dampers(PFD) can be employed.The performance of a PFD is highly dependent on the strategy applied to adjust its contact force.In this paper,the seismic control of a benchmark isolated building equipped with PFD using PD/PID controllers is developed.Using genetic algorithms,these controllers are optimized to create a balance between the performance and robustness of the closed-loop structural system.One advantage of this technique is that the controller forces can easily be estimated.In addition,the structure is equipped with only a single sensor at the base floor to measure the base displacement.Considering seven pairs of earthquakes and nine performance indices,the performance of the closed-loop system is evaluated.Then,the results are compared with those given by two well-known methods:the maximum possive operation of piezoelectric friction dampers and LQG controllers.The simulation results show that the proposed controllers perform better than the others in terms of simultaneous reduction of floor acceleration and maximum displacement of the isolator.Moreover,they are able to reduce the displacement of the isolator systems for different earthquakes without losing the advantages of isolation.  相似文献   

17.
Long-period structures(e.g. Isolated structures) tend to produce pseudo-resonance with low frequency components of long-period ground motions, resulting in the increase in damage. Stiffness mutation occurs due to the setback in the upper body of the large chassis structure. In the parts with stiffness mutation, the torsion effect caused by the tower is far greater than that of the chassis itself. In this study, a total of 273 ground motions are collected and then filtered into four types, including the near-field ordinary, near-field pulse, far-field ordinary, and farfield harmonic. An 8-degree(0.2 g) fortified large chassis base-isolated structure is established. Furthermore,ETABS program software is used to conduct nonlinear time history analysis on the isolation and seismic model under bi-directional earthquake ground motions. The comparison results show that the seismic isolation effect of the base-isolated structure under long-period ground motions is worse than that associated with ordinary ground motions when the seismic response reduction rate of the large base floor significantly decreases compared with that of the tower. When the inter-story displacement angle and the displacement of isolation layer of the chassis exceeds the limit of Code for Seismic Design of Buildings(GB 50011-2010), it is recommended to adopt composite seismic isolation technology or add limit devices. Under the condition of long-period ground motions, the baseisolated structure reduces the lateral-torsional coupling effect of the large chassis structure, while the torsion response of large chassis' top layer increases. Under long-period ground motions with the same acceleration peak,the response of the base-isolated structure increases much more than that of the seismic structure and the consideration of this impact is suggested to be added to the Code.  相似文献   

18.
Traditional control strategies have difficulty handling nonlinear behavior of structures, time variable features and parameter uncertainties of structural control systems under seismic excitation. An off-and-towardsequilibrium (OTE) strategy combined with fuzzy control is presented in this paper to overcome these difficulties. According to the OTE strategy, the control force is designed from the viewpoint of a mechanical relationship between the motions of the structure, the exciting force and the control force. The advantage of the OTE strategy is that it can be used for a variety of control systems. In order to evaluate the performance of the proposed strategy, the seismic performance of a three-story shear building with an Active Tendon System (ATS) using a Fuzzy Logic Controller (FLC) is studied. The main advantage of the fuzzy controller is its inherent robustness and ability to handle any nonlinear behavior of structures. However, there are no design guidelines to set up the corresponding control rule table for a FLC. Based on the proposed strategy for the FLC, a control rule table associated with the building under study is developed, which then allows formation of a detailed algorithm. The results obtained in this study show that the proposed strategy performs slightly better than the linear quadratic regulator (LQR) strategy, while possessing several advantages over the LQR controller. Consequently, the feasibility and validity of the proposed strategy are verified.  相似文献   

19.
带裙房高层建筑地震反应控制振动台试验研究   总被引:1,自引:1,他引:0  
2002年9月在香港理工大学成功地进行了带裙房高层建筑地震反应控制试验研究。设计和制作的结构模型是带3层裙房的12层高楼剪切模型,在裙房顶层与主楼之间安装单MR阻尼器形成MR阻尼器耦联结构模型。MR阻尼器采用美国LORD公司摩擦型MR阻尼器,并且选用其配套产品计算机电流控制器对其进行控制,控制系统采用德国dSPACE公司实时控制系统。对独立主楼、独立裙房和原结构模型的动力特性进行了辨识;对结构模型进行了El Centro地震动作用下的地震反应振动台试验;以作者提出的MR阻尼器半主动逻辑控制算法,对MR阻尼器耦联的结构模型进行了地震反应振动台试验。试验结果表明:用MR阻尼器耦联主楼与裙房,采用半主动逻辑控制方法进行控制,能有效抑制主楼的鞭梢效应并使主楼和裙房的地震反应减小。  相似文献   

20.
近断层脉冲型地震动作用下隔震结构地震反应分析   总被引:17,自引:5,他引:17  
隔震结构在远震场地减震效果良好,但是近断层地震动的明显的长周期速度和位移脉冲运动可能对隔震建筑等长周期结构的抗震性能和设计带来不利影响,需要深入探讨。本文首先讨论近断层地震动的长周期脉冲运动特征,然后以台湾集集地震8条典型近震记录和其它4条常用近震记录以及4条远震记录作为地震动输入,对两幢安装铅芯橡胶隔震支座的钢筋混凝土框架隔震结构进行非线性地震反应时程分析,通过比较探讨了算例计算结果,定量说明隔震结构的近震脉冲效应显著,是隔震设计不容忽视的问题。  相似文献   