首页 | 官方网站   微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 437 毫秒
1.
Aortic valve disease is usually treated by prosthetic valve replacement. We have performed aortic valve plasty (AVP) using glutaraldehyde-treated autologous pericardium. AVP was performed for 88 patients from April 2007 through August 2009. Sixty-five patients had aortic stenosis, and 23 patients had aortic regurgitation (AR). Twenty-one patients showed bicuspid aortic valves, and one patient showed quadricuspid valve. There were 43 males and 45 females. Their mean age was 70.6±10.5 years old. First, diseased leaflets excised. Then, the distance between each commissure was measured. The new leaflet were trimmed with an original template from a glutaraldehyde-treated autologous pericardium sample. Finally, the annular margin of the pericardial leaflet was running sutured to each annulus. There was no operative mortality or embolic event. Postoperative echocardiography revealed a mean peak pressure gradient (PG) of 19.0±9.1 mmHg one week after surgery. Thirty-two patients had echocardiography one year after surgery. The peak PG became 12.9±5.8 mmHg. Ten patients showed no AR, 20 patients showed trivial AR, and two patients showed mild AR. Freedom from reoperation is 100% at three years follow-up.  相似文献   

2.
3.
4.
From January 1998 to December 2002, a total of 120 patients underwent aortic valve surgery at our institution. Of these, 26 patients (22%) had congenital bicuspid aortic valve (BAV). Main valvular lesion of BAV was aortic valve stenosis (AS) in 17 and regurgitation (AR) in 9. There was no significant difference in the aortic annular size between BAV and non-BAV cases measured by echocardiography preoperatively [22.8 +/- 2.0 mm versus 22.5 +/- 2.2 mm in AS (NS), and 25.4 +/- 2.4 mm versus 23.4 +/- 2.5 mm in AR (NS)]. At operation, however, supraannular type prosthetic valve was selected more frequently in BAV than in non-BAV because of the difficulty of implanting the proper size prosthetic valve in annular position in BAV [10/25 (40%) in BAV versus 18/91 (20%) in non-BAV (p < 0.05)]. Moreover, ascending aortic dimension in BAV cases was significantly larger than in non-BAV cases [43.7 +/- 7.3 mm versus 39.6 +/- 7.3 mm (p<0.05)]. These features were more prominent in non-raphe BAV cases. These results suggested that operative procedure including prosthetic valve selection needs careful consideration in BAV especially no-raphe patients.  相似文献   

5.
Quadricuspid aortic valve   总被引:2,自引:0,他引:2  
A case of quadricuspid aortic valve is described. The anomaly was unexpectedly found during operation for aortic valve replacement in a 70-year-old woman. Macroscopic and histological examinations of the valve showed no sign of previous inflammatory disease. Quadricuspid aortic valve must be considered, therefore, a malformation capable of leading to severe valve failure in later life.  相似文献   

6.
7.
8.
9.
10.
11.
Stentless porcine aortic bioprosthesis has several potential advantages over conventional stented bioprosthesis. The Medtronic Freestyle aortic bioprosthesis, a stentless design analogous to an aortic allograft, has zero-pressure-fixed leaflets treated with an antimineralization agent, and has been shown to have benefits of superior effective orifice area, excellent flow characteristics and durability. To evaluate the early results for its efficacy in view of post-operative performance. The valve was implanted using the cylinder method, with subcoronary, root-inclusion techniques or full root techniques. No patients experienced any significant valvular regurgitation on echocardiography. The post-operative data of EDVI, ESVI and LVPWD decreased significantly as compared with the pre-operative data while ejection fraction remained unchanged. The average peak pressure gradient was 16.5 mmHg, and the average effective orifice area was 2.45 cm2. In conclusion, Freestyle stentless aortic bioprosthesis showed excellent hemodynamic function. It seems to be suited for the older patient with a small aortic annulus.  相似文献   

12.
13.
OBJECTIVE: Surgical aortic valvotomy has a long history of providing excellent palliation for aortic stenosis in infancy and childhood. The fate of aortic valve repairs for dominant aortic regurgitation in this same age group is considerably less clear. METHODS: From 1990 to 2000, a total of 21 patients underwent aortic valve repair for aortic regurgitation at our institution. Seventeen patients were younger than 17 years at the time of repair (3-17 years, mean 8.1 +/- 3.7 years). Of these 17 children, 6 (35%) had bicuspid valves and 11 (65%) had tricuspid valves. Type of repair varied with valve type, but repair generally consisted of commissure resuspension, partial commissure closure, triangular resection of redundant leaflets, or some combination. RESULTS: There were no deaths. Follow-up ranged from 1 to 11 years (mean 5.3 +/- 2.4 years). At present 3 of 17 (17.6%) have mild aortic regurgitation according to echocardiography and 6 (35.2%) have moderate aortic regurgitation. In 8 of 17 cases (47.1%) the repair clearly failed, requiring reoperation from 0.5 to 73 months after the original operation (mean 18.9 months). Reoperation consisted of 6 Ross procedures and 2 mechanical aortic valve replacements. There were no deaths at the secondary operation. CONCLUSION: Aortic valve repair in children with a dominant feature of aortic insufficiency tended to fail progressively and at a high rate. Leaflet thickening was associated with higher risk of repair failure in this series. The threshold for aortic valve replacement should remain low.  相似文献   

14.
15.
16.
17.
18.
A 53-year-old male who had been performed aortic valve replacement 15 weeks before was admitted to our hospital because of severe chest pain. Cjest computerized tomography showed dissection of aorta from ascending to descendig aorta and hemorrhage around ascending aorta. An emergency operation was performed under hypothermic circulatory arrest with a selective cerebral perfusion. An entry of dissection was found at posterior wall where was 3 cm upper from an artificial valve. Total arch replacement was successfully performed. There is a few caces of aortic dissection after aortic valve replacement, but careful peri and post operative care is necessary after aortic valve replacement.  相似文献   

19.
Aortic stenosis is one of the most common valve pathologies found in adults. Aortic valve replacement via a sternotomy and cardiopulmonary bypass is the treatment of choice for patients with symptomatic aortic stenosis with very acceptable risk. However, patients with advanced age and multiple comorbidities carry significant operative risk; operative mortality as high as 25% was reported by many groups. Many of these patients are deemed nonsurgical for conventional aortic valve replacement by their cardiologists and surgeons. Novel surgical technique and valve technology offers an alternative treatment for aortic valve stenosis. Endovascular transcatheter aortic valve replacement is an emerging and promising technique, and may lower the risk in this subset of difficult patients.  相似文献   

20.
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司    京ICP备09084417号-23

京公网安备 11010802026262号