首页 | 官方网站   微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
For selective C-terminal derivatization of peptides and proteins, we have devised a method for activating the C-terminal carboxyl group by extending the oxazolone chemistry. A mixture of formic acid and acetic anhydride was found to be effective for the formation of an oxazolone, which was converted to an active ester in situ in the presence of a phenol or an N-hydroxide. In particular, the resulting active ester with pentafluorophenol facilitated the subsequent reaction with an amine and the hydrazine derivative to yield the C-terminal amide and hydrazide, respectively. The peptides thus coupled with arginine methyl ester or 2-hydrazino-2-imidazoline containing the guanidino moiety exhibited the positive-ion peaks in matrix-assisted laser desorption/ionization (MALDI) mass spectra with appreciably enhanced intensities. As expected from the reaction mechanism, the carboxyl groups of aspartic and glutamic acid residues were not modified, while the amino groups that could react with the activated peptides were concomitantly protected by formylation. The MALDI peaks corresponding to the C-terminal peptide fragments of proteins were specifically enhanced, discriminating against those from internal peptides that were not tagged with a positive charge. In favorable cases, the C-terminal peptide fragments were clearly discerned by MALDI-MS after chymotryptic digestion and were identified by their MALDI postsource decay analysis. Based on these results, we suggest a method for C-terminal sequencing of a protein.  相似文献   

2.
C-Terminal sequence analysis of peptides and proteins using carboxypeptidase digestion in combination with matrix-assisted laser desorption/ionization mass spectrometry (MALDI-MS) is convenient for protein and peptide characterization. After a short digestion, a sequence up to 20 residues can be identified, but the total number depends on the individual sequence. Due to the accuracy limits of the MALDI time-of-flight arrangement, the assignment of several residues with close mass values, including Lys/Glx, may remain ambiguous. We have used derivatization of lysine residues by guanidination to overcome the problem of Lys identification. The reaction is rapid and specific and results in full derivatization. In the case of Cys-containing peptides, problems arise from the fact that carboxypeptidases Y and P do not cleave peptides that contain nonderivatized cystine, cysteic acid, or (carboxymethyl)cysteine. Successful identification of Cys residues within the sequence is instead achieved by conversion of Cys to 4-thialaminine by (trimethylamino)-ethylation. The two derivatizations of Lys and Cys side chains provide opportunities for proton attachment and therefore facilitate the analysis by MALDI-MS. This C-terminal sequence analysis method is also useful for large proteins after fragmentation with specific enzymes.  相似文献   

3.
The identification and quantification of specific phosphorylation sites within a protein by mass spectrometry has proved challenging when measured from peptides after protein digestion because each peptide has a unique ionization efficiency that alters with modification, such as phosphorylation, and because phosphorylation can alter cleavage by trypsin, shifting peptide distribution. In addition, some phosphorylated peptides generated by tryptic digest are small and hydrophilic and, thus, are not retained well on commonly used C18 columns. We have developed a novel C-terminal peptide (2)H-labeling derivatization strategy and a mass balance approach to quantify phosphorylation. We illustrate the application of our method using electrospray ionization liquid chromatography-mass spectrometry by quantifying phosphorylation of troponin I with protein kinase A and protein kinase C. The method also improves the retention and elution of hydrophilic peptides. The method defines phosphorylation without having to measure the phosphorylated peptides directly or being affected by variable miscleavage. Measurement of phosphorylation is shown to be linear (relative standard error <5%) with a detection limit of <10%.  相似文献   

4.
The peptide content of individual mammalian cells is profiled using matrix-assisted laser desorption/ionization (MALDI) time-of-flight mass spectrometry. Both enzymatic and nonenzymatic procedures, including a glycerol cell stabilization method, are reported for the isolation of individual mammalian cells in a manner compatible with MALDI MS measurements. Guided microdeposition of MALDI matrix allows samples to be created with suitable analyte-to-matrix ratios. More than 15 peptides are observed in individual rat intermediate pituitary cells. The combination of accurate mass data, expected cleavages by proteolytic enzymes, and postsource decay sequencing allows identification of 14 of these peptides as pro-opiomelanocortin prohormone-derived molecules. These protocols permit the classification of individual mammalian cells by peptide profile, the elucidation of cell-specific prohormone processing, and the discovery of new signaling peptides on a cell-to-cell basis in a wide variety of mammalian cell types.  相似文献   

5.
Matrix-assisted laser desorption/ionization (tandem) mass spectrometry (MALDI MS) is widely used in protein chemistry and proteomics research for the identification and characterization of proteins isolated by polyacrylamide gel electrophoresis. In an effort to minimize sample handling and increase sample throughput, we have developed a novel in-gel digestion protocol where sample preparation is performed directly on a MALDI probe with prestructured sample support. The protocol consists of few sample-handling steps and has minimal consumption of reagents, making the protocol sensitive, timesaving, and cost-efficient. Performance of the on-probe sample preparation protocol was demonstrated by analysis of a set of rat liver proteins obtained from a fluorescently stained (Cy3 and SyproRuby) two-dimensional polyacrylamide gel. The success rate of protein identification by on-probe tryptic digestion and MALDI peptide mass mapping was 89%. The on-probe in-gel digestion procedure provided superior sensitivity and peptide mass mapping performance as compared to our standard in-gel digestion protocol. The on-probe digestion technique resulted in significantly improved amino acid sequence coverage of proteins, mainly due to efficient recovery and detection of large (>1.5 kDa) hydrophobic peptides. These observations indicate that numerous tryptic peptides are lost when using the standard in-gel digestion methods and sample preparation techniques for MALDI MS. This study also demonstrates that the on-probe digestion protocol combined with MALDI tandem mass spectrometry provides a robust platform for proteomics research, including protein identification and determination of posttranslational modifications.  相似文献   

6.
Although alpha-cyano-4-hydroxycinnamic acid functions as an excellent matrix for the analysis of most peptides using matrix-assisted laser desorption/ionization time-of-flight (MALDI TOF) mass spectrometry, the ionization of phosphorylated peptides is usually suppressed by nonphosphorylated peptides. As an alternative matrix, 2',4',6'-trihydroxyacetophenone (THAP) with diammonium citrate was found to overcome this problem for the MALDI TOF mass spectrometric analysis of proteolytic digests of phosphorylated proteins. Specifically, the abundances of phosphorylated peptides in tryptic digests of bovine beta-casein and protein kinase C (PKC)-treated mouse cardiac troponin I were enhanced more than 10-fold using THAP during positive ion MALDI TOF mass spectrometry. The protonated molecules of phosphorylated peptides were sufficiently abundant that postsource decay TOF mass spectrometry was used to confirm the number of phosphate groups in each peptide. Finally, tryptic digestion followed by analysis using MALDI TOF mass spectrometry with THAP as the matrix facilitated the identification of a unique phosphorylation site in PKC-treated troponin I.  相似文献   

7.
Protein ubiquitination plays an important role in the degradation and other functional regulation of cellular proteins in organisms ranging from yeasts to mammals. Trypsin digestion of ubiquitin conjugated proteins produces diglycine branched peptides in which the C-terminal Gly-Gly fragment of ubiquitin is attached to the epsilon-amino group of a modified lysine residue within the peptide. This provides a platform for mapping ubiquitination sites using mass spectrometry. Here we report the development of a novel strategy for determining posttraslational protein ubiquitination based on the N-terminal sulfonation of diglycine branched peptides. In contrast to conventional tandem MS spectra of native tryptic peptides, MALDI MS/MS analysis of a sulfonated tryptic peptide containing a diglycine branch generates a unique spectrum composed of a signature portion and a sequence portion. The signature portion of the spectrum consists of several intense ions resulting from the elimination of the tags, the N-terminal residues at the peptide and the branch, and their combination. This unique ion distribution pattern can distinguish ubiquitination modificatons from others and can identify the first N-terminal residues of the peptides as well. The sequence portion consists of an exclusive series of y-type ions and y' ions (differing by the loss of one glycine residue from the sulfonated diglycine branch) that can directly reveal the amino acid sequence of the peptide and the precise location of the ubiquitination site. The technique is demonstrated for a series of synthetic peptides and is validated by a model protein, tetraubiquitin. Our results show that the MALDI MS/MS analysis of sulfonated tryptic peptides can provide a highly effective method for the determination of ubiquitination substrates, ubiquitination sites on protein targets, and modification sites on ubiquitins themselves.  相似文献   

8.
A new method for improving low-concentration sample recovery and reducing sample preparation steps in matrix-assisted laser desorption/ionization mass spectrometry (MALDI MS) is presented. In the conventional approach, samples are typically desalted and/or concentrated with various techniques and deposited on the MALDI target as small droplets. In this work, we describe a new approach in which an elastomeric device is reversibly sealed on the MALDI target to form a multi-well plate with the MALDI target as the base of the plate. The new format allows a larger volume (5-200 microL) of samples to be deposited on each spot and a series of sample handling processes, including desalting and concentrating, to be performed directly on the MALDI target. Several advantages have been observed: (i) multiple sample transferring steps are avoided; (ii) recovery of low-concentration peptides during sample preparation is improved using a novel desalting method that utilizes the hydrophobic surface of the elastomeric device; and (iii) sequence coverage of the peptide mass fingerprinting map is improved using a novel method in which proteins are immobilized on the hydrophobic surface of the elastomeric device for in-well trypsin digestion, followed by desalting and concentrating the digestion products in the same well.  相似文献   

9.
Ramos AA  Yang H  Rosen LE  Yao X 《Analytical chemistry》2006,78(18):6391-6397
Parallel fragmentations of peptides in the source region and in the collision cell of tandem mass spectrometers are sequentially combined to develop parallel collision-induced-dissociation mass spectrometry (p2CID MS). Compared to MS/MS spectra, the p2CID mass spectra show increased signal intensities (2-400-fold) and number of sequence ions. This improvement is attributed to the fact that p2CID MS virtually samples all the ions generated by electrospray ionization, including intact and fragment ions of different charge states from a peptide. We implement the method using a quadrupole time-of-flight tandem mass spectrometer. The instrument is operated in TOF-MS mode that allows the ions from source region broadband-passing the first mass analyzer to enter the collision cell. Cone voltage and collision energy are investigated to optimize the outcome of the two parallel CID processes. In the in-source parallel CID, elevated cone voltage produces singly charged intact peptide ions and large fragment ions, as well as decreases the charge-state distribution of peptide ions mainly to double and single charges. The in-collision-cell parallel CID is optimized to dissociate the ions from the source region to produce small and medium fragment ions. The method of p2CID MS is especially useful for sequencing of large peptides with labile amide bonds and peptides with C-terminal arginine. It has unique potential for de novo sequencing of peptides and proteome analysis, especially for affinity-enriched subproteomes.  相似文献   

10.
A novel ion trap time-of-flight hybrid mass spectrometer (qIT-TOF MS) has been applied for peptide sequencing in proteolytic digests generated from spore mixtures of Bacilli. The method of on-probe solubilization and in situ proteolytic digestion of small, acid-soluble spore proteins has been recently developed in our laboratory, and microorganism identification in less than 20 min was accomplished. In this study, tryptic peptides were generated in situ from complex spore mixtures of B. subtilis 168, B. globigii, B. thuringiensis subs. Kurstaki, and B. cereus T, respectively. MALDI analysis of bacterial peptides generated was performed with an average mass resolving power of 6200 and a mass accuracy of up to 10 ppm using a trap-TOF tandem configuration. Precursor ions of interest were usually selected and stored in the quadrupole ion trap with their complete isotope distribution by choosing a window of +/- 2 Da. Sequence-specific information on isolated protonated peptides was gained via tandem MS experiments with an average mass resolving power of 4450 for product ion analysis, and protein and bacterial sources were identified by database searching.  相似文献   

11.
Peptide mass mapping using matrix-assisted laser desorption/ionization (MALDI) mass spectrometry in conjunction with interrogation of sequence databases is a powerful tool for the identification of proteins. Glycosylated proteins often yield poor MALDI peptide maps due to shielding of proteolytic cleavage sites and the presence of modified peptides. Here we demonstrate that enzymatic removal of N-linked glycans with simultaneous partial (50%) 18O-labeling of glycosylated asparagine residues prior to proteolysis and MALDI peptide mass mapping can overcome these problems. As a result, more peptides are observed in MALDI spectra which, in turn, increases the specificity of subsequent database searches. Furthermore, the detection of a labeled peptide directly translates into partial sequence information as N-linked carbohydrates are exclusively attached to asparagine residues that form part of the NXS/T sequence. The mass of the formerly glycosylated peptide together with the NXS/T sequence pattern represents a discriminating criterion for database searching which, on average, increases the search specificity by a factor of 100. This procedure allows the unambiguous identification of glycoproteins that would otherwise require sequencing and, at the same time, enables the identification of N-glycosylation sites with higher sensitivity than previously possible.  相似文献   

12.
A new matrix-assisted laser desorption/ionization (MALDI) time-of-flight/time-of-flight (TOF/TOF) high-resolution tandem mass spectrometer is described for sequencing peptides. This instrument combines the advantages of high sensitivity for peptide analysis associated with MALDI and comprehensive fragmentation information provided by high-energy collision-induced dissociation (CID). Unlike the postsource decay technique that is widely used with MALDI-TOF instruments and typically combines as many as 10 separate spectra of different mass regions, this instrument allows complete fragment ion spectra to be obtained in a single acquisition at a fixed reflectron voltage. To achieve optimum resolution and focusing over the whole mass range, it may be desirable to acquire and combine three separate sections. Different combinations of MALDI matrix and collision gas determine the amount of internal energy deposited by the MALDI process and the CID process, which provide control over the extent and nature of the fragment ions observed. Examples of peptide sequencing are presented that identify sequence-dependent features and demonstrate the value of modifying the ionization and collision conditions to optimize the spectral information.  相似文献   

13.
Gu S  Pan S  Bradbury EM  Chen X 《Analytical chemistry》2002,74(22):5774-5785
Here, we describe a method for protein identification and de novo peptide sequencing. Through in vivo cell culturing, the deuterium-labeled lysine residue (Lys-d4) introduces a 4-Da mass tag at the carboxyl terminus of proteolytic peptides when cleaved by certain proteases. The 4-Da mass difference between the unlabeled and the deuterated lysine assigns a mass signature to all lysine-containing peptides in any pool of proteolytic peptides for protein identification directly through peptide mass mapping. Furthermore, it was used to distinguish between N- and C-terminal fragments for accurate assignments of daughter ions in tandem MS/MS spectra for sequence assignment. This technique simplifies the labeling scheme and the interpretation of the MS/MS spectra by assigning different series of fragment ions correctly and easily and is very useful in de novo peptide sequencing. We have also successfully implemented this approach to the analysis of protein mixtures derived from the human proteome.  相似文献   

14.
Immobilized metal ion affinity chromatography (IMAC) is a useful method to selectively isolate and enrich phosphopeptides from a peptide mixture. Mass spectrometry is a very suitable method for exact molecular weight determination of IMAC-isolated phosphopeptides, due to its inherent high sensitivity. Even exact molecular weight determination, however, is not sufficient for identification of the phosphorylation site if more than one potential phosphorylation site is present on a peptide. The previous method of choice for sequencing the affinity-bound peptides was electrospray tandem mass spectrometry (ESI-MS/MS). This method required elution and salt removal prior to MS analysis of the peptides, which can lead to sample loss. Using a matrix-assisted laser desorption/ionization (MALDI) source coupled to an orthogonal injection quadrupole time-of-flight (QqTOF) mass spectrometer with true MS/MS capabilities, direct sequencing of IMAC-enriched peptides has been performed on IMAC beads applied directly to the MALDI target. The utility of this new method has been demonstrated on a protein with unknown phosphorylation sites, where direct MALDI-MS/MS of the tryptic peptides bound to the IMAC beads resulted in the identification of two novel phosphopeptides. Using this technique, the phosphorylation site determination is unambiguous, even with a peptide containing four potentially phosphorylated residues. Direct analysis of phosphorylated peptides on IMAC beads does not adversely affect the high-mass accuracy of an orthogonal injection QqTOF mass spectrometer, making it a suitable technique for phosphoproteomics.  相似文献   

15.
The separation of peptide mixtures from proteolytic cleavage is often necessary prior to mass spectrometry (MS) to enhance sensitivity and peptide mapping coverage. When buffers, salts, and other higher abundance peptides/contaminants are present, competition for charge during the electrospray ionization and matrix-assisted laser desorption/ionization (MALDI) processes can lead to ion suppression for the targeted analyte(s). In this note, a simple reversed-phase microcolumn sample separation and deposition device (Sep-Dep) is described. The use of this device improves or renders possible the analysis of complex or contaminated peptide mixtures by MALDI-MS. The method is simple and inexpensive and utilizes single-use low-cost Geloader-type columns packed with reversed-phase material. The device described utilizes an open column, allowing for a gradient or narrow-step gradient to be applied by any solvent delivery system or manually with a pipet. A key feature of the device is a deposition chamber that can be custom-built to hold any MALDI target. The Sep-Dep device is attached directly to an in-house vacuum line and draws solvent from the open-ended LC column. The elution of separated peptides is performed directly onto a target that has been treated with a hydrophobic barrier. This barrier effectively isolates fractions and improves the quality and morphology of the matrix crystals. The method produces efficient separations of proteolytic peptides, significantly reducing signal suppression effects in MALDI.  相似文献   

16.
Improved procedures for guanidination of lysine-containing peptides, a derivatization that results in increased MALDI mass spectral signal intensities are presented. The complete conversion of lysines to homoarginines can be accomplished in as little as 5 min. The method is demonstrated on a model peptide and on tryptic digests of three proteins. To demonstrate the applicability to proteomics samples, it is successfully applied to the digest of 50 fmol of a protein. Approaches for concentrating and purifying low-quantity protein digests following guanidination are evaluated. Experiments with the model peptide GRGDSPK enable investigation of the specificity of the guanidination reaction.  相似文献   

17.
We report an online nonenzymatic method for site-specific digestion of proteins to yield peptides that are well suited for collision-induced dissociation tandem mass spectrometry. The method combines online microwave heating acid hydrolysis at aspartic acid and online electrochemical oxidation at tryptophan and tyrosine. The combined microwave/electrochemical digestion is reproducible and produces peptides with an average sequence length of 10 amino acids. This peptide length is similar to the average peptide length of 9 amino acids obtained by digestion of proteins with the enzyme trypsin. As a result, the peptides produced by this novel nonenzymatic digestion method, when analyzed by electrospray ionization mass spectrometry, produce protonated molecules with mostly +1 and +2 charge states. The combination of these two nonenzymatic methods overcomes shortcomings with each individual method in that (i) peptides generated by the microwave-hydrolysis method have an average amino acid length of 16 amino acids and (ii) the electrochemical-cleavage method is unable to reproducibly digest proteins with molecular masses above 4 kDa. Preliminary results are presented on the application and utility of this rapid online digestion (total of 6 min of digestion time) on a series of standard peptides and proteins as well as an Escherichia coli protein extract.  相似文献   

18.
MALDI imaging allows the creation of a "molecular image" of a tissue slice. This image is reconstructed from the ion abundances in spectra obtained while rastering the laser over the tissue. These images can then be correlated with tissue histology to detect potential biomarkers of, for example, aberrant cell types. MALDI, however, is known to have problems with ion suppression, making it difficult to correlate measured ion abundance with concentration. It would be advantageous to have a method which could provide more accurate protein concentration measurements, particularly for screening applications or for precise comparisons between samples. In this paper, we report the development of a novel MALDI imaging method for the localization and accurate quantitation of proteins in tissues. This method involves optimization of in situ tryptic digestion, followed by reproducible and uniform deposition of an isotopically labeled standard peptide from a target protein onto the tissue, using an aerosol-generating device. Data is acquired by MALDI multiple reaction monitoring (MRM) mass spectrometry (MS), and accurate peptide quantitation is determined from the ratio of MRM transitions for the endogenous unlabeled proteolytic peptides to the corresponding transitions from the applied isotopically labeled standard peptides. In a parallel experiment, the quantity of the labeled peptide applied to the tissue was determined using a standard curve generated from MALDI time-of-flight (TOF) MS data. This external calibration curve was then used to determine the quantity of endogenous peptide in a given area. All standard curves generate by this method had coefficients of determination greater than 0.97. These proof-of-concept experiments using MALDI MRM-based imaging show the feasibility for the precise and accurate quantitation of tissue protein concentrations over 2 orders of magnitude, while maintaining the spatial localization information for the proteins.  相似文献   

19.
Interest in peptides incorporating boronic acid moieties is increasing due to their potential as therapeutics/diagnostics for a variety of diseases such as cancer. The utility of peptide boronic acids may be expanded with access to vast libraries that can be deconvoluted rapidly and economically. Unfortunately, current detection protocols using mass spectrometry are laborious and confounded by boronic acid trimerization, which requires time-consuming analysis of dehydration products. These issues are exacerbated when the peptide sequence is unknown, as with de novo sequencing, and especially when multiple boronic acid moieties are present. Thus, a rapid, reliable, and simple method for peptide identification is of utmost importance. Herein, we report the identification and sequencing of linear and branched peptide boronic acids containing up to five boronic acid groups by matrix-assisted laser desorption/ionization mass spectrometry (MALDI-MS). Protocols for preparation of pinacol boronic esters were adapted for efficient MALDI analysis of peptides. Additionally, a novel peptide boronic acid detection strategy was developed in which 2,5-dihydroxybenzoic acid (DHB) served as both matrix and derivatizing agent in a convenient, in situ, on-plate esterification. Finally, we demonstrate that DHB-modified peptide boronic acids from a single bead can be analyzed by MALDI-MSMS analysis, validating our approach for the identification and sequencing of branched peptide boronic acid libraries.  相似文献   

20.
Xu Y  Zhang L  Lu H  Yang P 《Analytical chemistry》2008,80(21):8324-8328
A nearly 100% yield peptide carboxy group derivatization method was offered to largely enhance phosphopeptide ionization efficiency. This method, adopting 1-(2-pyrimidyl) piperazine (PP) as the derivatization reagent, shows several advantages such as good reproducibility, ease of handling, rapid reaction time, and no side reaction. PP derivatization improves the hydrophobicities, p I values, and gas-phase basicities of peptides especially those of phosphopeptides. In the matrix assisted laser desorption ionization (MALDI) source, the ionization efficiencies of four synthetic phosphopeptides were increased by 50-101 times while that of three nonphosphopeptides were 10-40-fold. In the electrospray ionization (ESI) source, PP-derivatized phosphopeptides also gave much higher ionization efficiency improvements than nonphosphopeptides. When this method was applied to much more complex mixtures, tryptic BSA digests spiked with one single phosphopeptide in different molar ratios, the signal intensity of this phosphopeptide always had the largest increment among all those peptides. Obviously, this easily manipulated as well as highly specific method provides a promising tool for high-throughput phosphoproteome research.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司    京ICP备09084417号-23

京公网安备 11010802026262号