首页 | 官方网站   微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
A laboratory scale sequential anaerobic migrating blanket reactor (AMBR)/aerobic completely stirred tank reactor (CSTR) system was operated to investigate the effect of increasing nitrobenzene (NB) concentrations on the performance of AMBR/CSTR reactor system. The reactor system was operated at increasing NB loading rates from 1.93?to?38.54?g?NB?m?3?day?1 and at a constant hydraulic retention time of 10.38?days. In this study, chemical oxygen demand (COD) and NB removal efficiencies, variations of bicarbonate alkalinity (Bic.Alk.), total volatile fatty acid (TVFA), and total methane gases were monitored. COD removal efficiencies were 93–94% until a NB loading rate of 5.78?g?m?3?day?1 in the AMBR reactor. For maximum COD removal, the optimum NB loading rate and NB concentration were found to be 5.78?g?m?3?day?1 and 60?mg?L?1, respectively. COD removal efficiencies decreased from 94 to 87% and to 85% at NB loading rates of 1.93–28.90 and 38.54?g?m?3?day?1, respectively. COD was mainly removed in the first compartment. NB removal efficiencies also were approximately 100% at all NB loading rates in the effluent of the AMBR reactor. The maximum total gas and methane gas productions were found to be 2.8?L?day?1 and 1.3?mL?day?1, respectively, at a NB loading rate of 5.78?g?m?3?day?1. The TVFA concentration in the effluent of AMBR was low (17?mg?L?1) at a NB loading rate as high as 38.54?g?m?3?day?1. Overall COD removal efficiencies were found to be 99 and 96% at NB loading rates of 1.93 and 38.54?g?m?3?day?1, respectively, in a sequential AMBR/CSTR reactor system. In this study, NB was reduced to aniline under anaerobic conditions. Aniline removal efficiencies were 100% until a NB loading rate of 17.34?g?m?3?day?1 in aerobic CSTR reactor while aniline removal efficiency decreased to 90% at a NB loading rate of 38.54?g?m?3?day?1 in an aerobic reactor. In the aerobic step, aniline was mineralized to catechol. The contribution of aerobic step is not only the degradation of aniline, it may also increase the COD removals from 85 to 99% at a NB loading rate as high as 38.54?g?m?3?day?1.  相似文献   

2.
Three 3?L laboratory scale submerged anaerobic membrane bioreactors (SAMBRs) with in situ membrane cleaning due to the bubbling of recycled biogas underneath them were studied for their ability to treat dilute wastewaters. Both Mitsubishi Rayon hollow-fiber and Kubota flat sheet membranes made of polyethylene with a pore size of 0.4?μm were used in this study, and the effect of different substrates (460?mg/L of glucose or synthetic) on chemical oxygen demand (COD) performance in the SAMBR was investigated. It was found that both membranes resulted in similar COD removals (>90% soluble COD at a hydraulic retention time of 3?h), but that the transmembrane pressure across the hollow fiber membranes was higher under similar conditions. Molecular weight analysis of the feed, reactor contents, effluent, and extracellular polymers using high pressure liquid chromatography showed that the membrane filtered out most of the high MW soluble organics, resulting in high COD removals. The experimental results from the SAMBR show the potential benefits of using this novel reactor design in a biological wastewater treatment process to minimize energy use and sludge production.  相似文献   

3.
Anaerobic degradation of phenol mixed with a readily degradable synthetic wastewater (DSWW) as a cosubstrate was studied in a 12?L upflow anaerobic sludge blanket reactor at 30±2°C over a period of 632?days. DSWW was prepared by diluting sugar cane based molasses. The biomass was acclimatized to high phenol concentration by gradually decreasing the DSWW chemical oxygen demand (COD) of 4,000?mg/L. Feed made up of phenol COD and DSWW COD in the ratio of 7:3 (phenol concentration = 1,176?mg/L) was successfully treated at a hydraulic retention time (HRT) of 12?h and organic loading rate (OLR) of 8?g?COD/L?day. Phenol removal ranged from 99.9 to 84% at phenol COD varying from 10 to 70% in the feed. During the entire operation, COD removal varied from about 74 to 91.3%. The influent COD was distributed into CH4–COD ( ~ 72%), effluent COD ( ~ 17%), and sludge and unaccounted COD ( ~ 11%). The process failure occurred at 4:1 phenol COD: DSWW COD. Specific methanogenic activity of granular sludge exhibited uniform activity up to phenol COD of 70%. The performance of the reactor could not be maintained beyond 70% phenol COD even by reducing the sludge loading rate, increasing HRT, or decreasing OLR.  相似文献   

4.
Anaerobic and aerobic treatment of high-strength pharmaceutical wastewater was evaluated in this study. A batch test was performed to study the biodegradability of the wastewater, and the result indicated that a combination anaerobic-aerobic treatment system was effective in removing organic matter from the high-strength pharmaceutical wastewater. Based on the batch test, a pilot-scale system composed of an anaerobic baffled reactor followed by a biofilm airlift suspension reactor was designed. At a stable operational period, effluent chemical oxygen demand (COD) from the anaerobic baffled reactor ranged from 1,432 to 2,397?mg/L at a hydraulic retention time (HRT) of 1.25 day, and 979 to 1,749?mg/L at an HRT of 2.5 day, respectively, when influent COD ranged from 9,736 to 19,862?mg/L. As a result, effluent COD of the biofilm airlift suspension reactor varied between 256 and 355?mg/L at HRTs of from 5.0 to 12.5 h. The antibiotics ampicillin and aureomycin, with influent concentrations of 3.2 and 1.0?mg/L, respectively, could be partially degraded in the anaerobic baffled reactor: ampicillin and aureomycin removal efficiencies were 16.4 and 25.9% with an HRT of 1.25 day, and 42.1 and 31.3% with HRT of 2.5 day, respectively. Although effective in COD removal, the biofilm airlift suspension reactor did not display significant antibiotic removal, and the removal efficiencies of the two antibiotics were less than 10%.  相似文献   

5.
Carbon tetrachloride (CT) in a synthetic wastewater was effectively degraded in a 2?l upflow anaerobic sludge blanket reactor during the granulation process by increasing the chemical oxygen demand (COD) and CT loadings. The effect of operational parameters such as influent CT concentrations, COD, CT loading, food to mass (F/M) ratio, and specific methanogenic activity (SMA) were also detected during granulation. Over 97% of CT was removed at 37°C, at a COD loading rate of 10?g/L?day. Chemical oxygen demand and CT removal efficiencies of 92 and 88% were achieved when the reactor was operating at CT and COD loading rates of 17.5?mg/L?day and 12.5?g/L?day, respectively. This corresponds to an hydraulic retention time of 0.28?day and an F/M ratio of 0.57?g?COD/g?volatile?suspended?solids?(VSS)?day. In 4?weeks, the seed sludge developed the CT degrading capability that was not very sensitive to shocks. The granular sludge cultivated had a maximum diameter of 2.5?mm and SMA of 1.64?g?COD/g?VSS?day. Glucose biodegradation by CT acclimated anaerobic granules was expressed with competitive inhibition. However the competitive inhibition was not significant since the competitive inhibition coefficient (Ki) was as high as 18.72?mg/L. Kinetic coefficients of k (maximum specific substrate utilization rate), Ks (half velocity coefficient), Y (growth yield coefficient), and b (decay coefficient) were determined as 0.6/day, 1.1?mg/L, 0.23?g?VSS/g glucose-COD, and 0.01/day, respectively, based on growth substrate glucose–COD during CT biotransformation. The CT was treated via biodegradation and this contributed to 89% of the total removal. The removal contributions from biomass adsorption, abiotic transformation, and volatilization were negligible. Adsorption and volatilization accounted for only 0.8 and 0.5% of the total removal, respectively.  相似文献   

6.
The use of a combined anaerobic fluidized bed and zeolite fixed bed system in sanitary landfill leachate treatment was investigated. Anaerobic treatability studies were successfully performed in the anaerobic fluidized bed reactor. The chemical oxygen demand (COD) removal was attained up to 90% with increasing organic loading rates as high as 18?g?COD/L?day after 80?days of operation. Good biogas production yield (Ygas) of 0.53?L biogas per gram removed COD with methane (CH4) content of 75% was obtained. The attached biomass concentration increased along the column height from bottom to top, and its mean value was found 6,065?mg/L after 100?days of operation. The anaerobically treated landfill leachate was further treated by a zeolite fixed bed reactor. While excellent ammonia removal (>90%) was obtained with the untreated zeolite, the regenerated zeolites showed higher performance. Consequently, this combined anaerobic and adsorption system is an effective tool to remove high COD and high ammonia in landfill leachate.  相似文献   

7.
The performance of a sequencing batch biofilter integrating anaerobic/aerobic conditions in one tank to treat a pharmaceutical wastewater effluent was studied. A pilot reactor, packed with a porous volcanic stone (puzzolane) was used in the study. The reactor operated as a sequencing batch biofilter, SBB, with reaction times varying for the anaerobic stage from 8 to 24 h and for the aerobic one from 4 to 12 h. The volume of exchange was from 16 to 88%. The pharmaceutical wastewater contained organic chemicals including phenols and o-nitroaniline, a concentration of organic matter that varied from 28,400 to 72,200 mg/L (as total COD), 280 to 605 mg N-NH4/L. and 430 to 650 mg SST/L. In order to acclimatize the microorganisms to the industrial wastewater, the organic load was increased stepwise from 1 to 7.7 kg COD/m3/d. The adequate time was obtained when the removal efficiency of COD reached 80%, or more. Maximal removal loads, associated to high removal efficiencies (95-97% as COD), varied from 4.6 to 5.7 kg COD/m3/d. Under these conditions color removal was 80% as Pt-Co units. Microtox analysis was performed to the wastewater and to the anaerobic and aerobic stages. It was observed that the aerobic stage was the responsible for wastewater detoxification. Results showed that the anaerobic/aerobic SBB was able to treat efficiently initial concentrations of the raw effluent up to 28,400 mg COD/L.  相似文献   

8.
Aerobic granular sludge technology was applied to the simultaneous nitrogen and phosphorus removal from livestock wastewater that contains high concentrations of nitrogen and phosphorus (TN: 650?mg/L; TP: 125?mg/L). A lab-scale sequencing batch reactor was operated in an alternating anaerobic/oxic/anoxic denitrification mode. Granular sludge was first formed using synthetic wastewater. When livestock wastewater was diluted with tap water, the shape and settleability of aerobic granular sludge were maintained even though livestock wastewater contained suspended solids. Simultaneous nitrification, denitrification, and phosphate uptake were observed under an aerobic condition. However, when nondiluted livestock wastewater was used, the diameter of granular sludge and the denitrification efficiency under an oxic condition decreased. When the concentrations of nitrogen and phosphorus in wastewater increased, hydraulic retention time (HRT) increased resulting in a decrease in selection pressure for granular sludge. Therefore, the sustainment of granular sludge was difficult in livestock wastewater treatment. However, by applying a new excess sludge discharge method based on Stokes’ law, the shape of granular sludge was maintained in spite of the long HRT (7.5?days). To select large granular sludge particles, excess sludge was discharged from the upper part of settled sludge because small particles localized there after settling. Finally, excellent nitrogen and phosphorus removal was accomplished in practical livestock wastewater treatment. The effluent concentrations of NH4–N, NOx–N, and PO4–P were <0.1, 1.4, and 1.2?mg/L, respectively.  相似文献   

9.
This study examined the effect of the addition of activated carbon to three, 3 L submerged anaerobic membrane bioreactors (SAMBRs) in terms of chemical oxygen demand (COD) removal, flux, and transmembrane pressure (TMP). The feed was a synthetic substrate with a COD of 460?mg?L?1, with one reactor run as a control, one with 1.7?g?L?1 of powdered activated carbon (PAC), and the third with 1.7?g?L?1 of granular activated carbon (GAC). While COD removal was high in all reactors (>90%), in comparison to the control (SAMBR1), the average COD removal in SAMBR2 (PAC) increased by 22.4%, while SAMBR3 with GAC was not significantly better. Because PAC has a significantly greater surface area per mass than GAC, it is probable that this difference was primarily due to the greater absorbance of fine colloidal particles and high molecular weight organics onto the carbon surface. These effects manifested themselves by SAMBR2 having lower TMPs and higher fluxes than both SAMBR3 and SAMBR1. Volatile fatty acids in the effluent from all three SAMBRs were extremely low (<18?mg?L?1), even during step changes in hydraulic retention tune, and most of the soluble COD in the effluent was soluble microbial products. Biochemical methane potential assays showed that biomass in the SAMBRs was less active than the seed sludge, and it appears that the addition of activated carbon to Reactors SAMBR2 and SAMBR3 provided a solid support for growth, and hence reduced floc breakage.  相似文献   

10.
An innovative anaerobic digestion elutriated phased treatment (ADEPT) has been evaluated at mesophilic (M-ADEPT) (35°C) and thermophilic (T-ADEPT) (55°C) temperatures in which the organic loading rate (OLR) was increased until reactor failure (pH<5.5). Single-stage continuously stirred tank reactors (CSTRs) at both temperatures were also operated as controls (M-CSTR for 35°C and T-CSTR for 55°C). The T-CSTR failed at an OLR of 7.4 g volatile solid (VS)/L?day and the M-CSTR at an OLR of 10 g VS/L?day while the M-ADEPT continued until an OLR of 18 g VS/L?day and the T-ADEPT reached an OLR of 24 g VS/L?day before system failure. The T-CSTR produced the poorest effluent quality as manifested by high propionate concentrations (1,500–2,500 mg/L) while both M-ADEPT and T-ADEPT produced much better quality of effluent with propionate concentrations below 100 mg/L. Thus it appears that the T-ADEPT design may solve effluent quality problems associated with normally high propionate concentrations produced during thermophilic anaerobic digestion. Superior effluent quality, reduced reactor volume requirements, more stable methanogenesis due to the extended solids retention time, and uncoupling of the methanogen wasting from the refractory sludge wasting process resulted in stable and efficient processing at both temperatures for the innovative ADEPT design. Because the higher amounts of volatile fatty acids produced in the acid elutriation phase of the ADEPT system can be a favorable carbon source for biological nutrient removal in wastewater treatment plants, this positive aspect should be considered in future applications of the ADEPT system.  相似文献   

11.
An innovative anaerobic–aerobic integrated bioreactor system consisting of an upflow anaerobic sludge blanket (UASB) and a jet loop reactor was developed to investigate the feasibility of combined removal of carbon and nitrogen for a low-strength wastewater at different hydraulic retention times (HRTs) and recycle ratios. Total chemical oxygen demand (COD) removal of the integrated system increased from 87 to 92%, at a combined system HRT of 44?h, when the recycle ratio was increased from 100 to 400%, respectively. Denitrification efficiency of the integrated system increased from 49 to 86%, at all HRTs, when the recycle ratio was increased from 100 to 400%. The integrated system, on average, achieved more than 78% of total nitrogen at all HRTs. Nitrogen content of the biogas produced from the UASB reactor increased with increase in recycle ratios while the methane content exhibited a reverse trend, irrespective of the HRTs. Sludge volume index of the UASB reactor increased from 15?to?42?mL/g total suspended solids at the end of the study. Specific methanogenic activity of the granular sludge decreased from 1.3 to 0.8 g CH4–COD/g volatile suspended solids per day at the end of the study. Nitrogen and COD mass balance of the integrated system indicated that a substantial amount of influent nitrogen and COD was lost in the effluent as dissolved form.  相似文献   

12.
Models ranging through simple, intermediate, and International Water Association complex activated sludge models (ASMs) were evaluated to compare their ability to describe biomass growth and substrate removal in an activated sludge system. A membrane-activated sludge bench-scale system was used to treat a complex synthetic wastewater over a wide range of operating conditions, ranging from 1 to 15 days solids retention time and 4 to 12 h hydraulic retention time. Total suspended solids, volatile suspended solids (VSSs), and total and soluble chemical oxygen demands (CODs) were monitored in the influent, the reactor, and the effluent. A variety of substrate removal formulations were used with the simple and intermediate models. Although all models provide excellent prediction of biomass growth, the intermediate model was best. Prediction of substrate removal was good with models that incorporated a nonbiodegradable component in the influent. ASM3 was the best model for predicting effluent soluble COD, but overall, the intermediate model was judged best for prediction of mixed liquor VSS and effluent soluble COD.  相似文献   

13.
Anaerobic degradation of sulfate laden organics has been investigated employing bench-scale models of an upflow anaerobic sludge blanket (UASB) reactor, anaerobic baffled reactor (ABR), and hybrid ABR (HABR). Results indicated chemical oxygen demand (COD) removal over 65% in all three systems at a COD/SO42? ratio of 8.57–8.59. However, the performance deteriorated at a low COD/SO42? ratio of 6.92–7.05 with a reduction in COD removal to 41–55%. Supplementation of limiting nutrients improved COD removal ( ≈ 94.5%) in an UASB system and indicated nutrient deficiency as a primary cause of poor performance. However, poor COD removal (45.92–56.12%) in ABR and HABR indicated a severe inhibition of microbial consortia by sulfide. This study revealed that system configuration aggravated the problem of sulfide toxicity due to sequential phase separation in ABR and HABR systems at low dissolved sulfide concentration relative to the UASB reactor, a single-phase system. Sulfate removal was over 88% in all three systems.  相似文献   

14.
This study examined the effects of COD:N:P ratio on nitrogen and phosphorus removal in a single upflow fixed-bed filter provided with anaerobic, anoxic, and aerobic conditions through effluent and sludge recirculation and diffused air aeration. A high-strength wastewater mainly made of peptone, ammonium chloride, monopotassium phosphate, and sodium bicarbonate with varying COD, N, and P concentrations (COD: 2,500–6,000, N: 25–100, and P: 20–50 mg/L) was used as a substrate feed. Sodium acetate provided about 1,500 mg/L of the wastewater COD while the remainder was provided by glucose and peptone. A series of orthogonal tests using three factors, namely, COD, N, and P concentrations, at three different concentration levels were carried out. The experimental results obtained revealed that phosphorus removal efficiency was affected more by its own concentration than that of COD and N concentrations; while nitrogen removal efficiency was unaffected by different phosphorus concentrations. At a COD:N:P ratio of 300:5:1, both nitrogen and phosphorus were effectively removed using the filter, with removal efficiencies at 87 and 76%, respectively, under volumetric loadings of 0.1?kg?N/m3?d and 0.02?kg?P/m3?d.  相似文献   

15.
Anaerobic pretreatment followed by aerobic posttreatment of municipal wastewater is being used more frequently. Recent investigations in this field using an anaerobic fluidized bed reactor/aerobic solids contact combination demonstrated the technical feasibility of this process. The investigation presented herein describes the use of a combined upflow anaerobic sludge bed (UASB)/aerobic solids contact system for the treatment of municipal wastewater and attempts to demonstrate the technical feasibility of using the UASB process as both a pretreatment unit and a waste activated sludge digestion system. The results indicate that the UASB reactor has a total chemical oxygen demand removal efficiency of 34%, and a total suspended solids removal efficiency of about 36%. Of the solids removed by the unit, 33% were degraded by the action of microorganisms, and 4.6% accumulated in the reactor. This low solids accumulation rate allowed operating the UASB reactor for three months without sludge wasting. The long solids retention time in this unit is comparable to the one normally used in conventional sludge digestion units, thus allowing the stabilization of the waste activated sludge returned to the UASB reactor. Particle flocculation was very poor in the UASB reactor, and therefore, it required postaeration periods of at least 100?min to proceed successfully in the aerobic unit. Polymer generation, which is necessary for efficient biological flocculation, was practically nonexistent in the anaerobic unit; therefore, it was necessary to maintain dissolved oxygen levels greater than 1.5?mg/L in the aerobic solids contact chamber for polymer generation to proceed at optimum levels. Once these conditions were attained, the quality of the settled solids contact chamber effluent always met the 30?mg BOD/L, 30?mg SS/L secondary effluent guidelines.  相似文献   

16.
Color removal from cotton textile processing wastewater by addition of powdered activated carbon (PAC) into a lab-scale activated sludge system was examined. The activated sludge system was continuously operated in different sludge ages (SRTs) and hydraulic retention times (HRTs). SRT = 30?d and HRT = 1.6?d operation resulted in up to 36% color removal and 94% COD removal. PAC was added 100, 200, and 400 mg/L into the activated sludge system under these operating conditions. The results indicated that 100 mg/L PAC was sufficient to remove the maximum color measured (up to 50 m?1) from the wastewater. The addition of PAC did not affect chemical oxygen demand (COD) removal significantly. Oxygen uptake rate (OUR) tests were also performed to investigate the microbial activities controlling the system performance. The average OUR was 74.1 mg/L/h without PAC addition while it was 70 mg/L/h with PAC addition. Adsorbable organic halogens of the effluent wastewater decreased from 400 to 50 μg/L with the addition of PAC. Toxicity dilution factor decreased from 2 to 1.5 with the PAC addition into the activated sludge system.  相似文献   

17.
A predenitrification system consisting of an ultracompact biofilm reactor (UCBR) and a packed bed column was used for removing nitrogen from synthetically simulated wastewater. The UCBR column was maintained under aerobic conditions to favor nitrification process, while the packed bed column was operated under an anoxic environment for denitrification process. A peristaltic pump was used to recycle fluid between the anoxic-packed bed and aerobic-UCBR columns to facilitate nitrogen removal. Five recycle ratios (R) were investigated, namely, 3, 4, 5, 6, and 10. The highest average total nitrogen (TN) removal rate was achieved at R = 4. The NH4+–N, TN, and chemical oxygen demand (COD) removal rates at this R were 0.56±0.05?kg NH4+–N/m3/day, 0.39±0.09?kg TN/m3/day, and 1.83±0.18?kg COD/m3/day, respectively. It was noted that poor nitrification in the UCBR was accompanied by a corresponding reduction in overall TN removal efficiency. This observation suggested that nitrification process was the limiting step for TN removal in this setup. Thus, the performance of this predenitrification system could be enhanced by optimizing the performance of the nitrification process.  相似文献   

18.
Three dye solutions, namely, C.I. Acid Yellow 17, C.I. Basic Blue 3, and C.I. Basic Red 2, were treated in an upflow anaerobic sludge blanket (UASB) reactor followed by a semi-continuous aerobic activated sludge tank. When hydraulic retention time was about 12 hours, no significant color removal was observed in the aerobic stage. In the anaerobic stage, Acid Yellow 17, Basic Blue 3, and Basic Red 2 were removed by 20%, 72%, and 78%, respectively. To treat wastewater from a dye manufacturing factor with COD concentration of 1200 mg/l and Color of 500 degrees (dilution factor), an UASB reactor (4.5 liters) and an activated sludge tank (5 liters, adjustable), COD and color were removed by more than 83% and 90% at a COD loading rate of 5.3 kg COD/m3-day in the anaerobic stage, and at the hydraulic retention time of 6-10 hours for the anaerobic stage and 6.5 for the aerobic stage. The anaerobic stage of the A/O system removes both color and COD. In addition, it also improves biodegradability of dyes for further aeroic treatment.  相似文献   

19.
The main objective of the present study is to develop a modified membrane bioreactor (MBR) system for the treatment of municipal wastewater for the enhanced biological removal of nitrogen (N) and phosphorus (P) simultaneously with the ultimate goal of optimizing the two processes. The paper will address the implementation and optimization of the MBR process with respect to biological characteristics, operational performance, and effluent quality. The system utilizes anoxic P uptake and nitrification–denitrification in a MBR. Following optimization, the system achieved 99% chemical oxygen demand (COD), 98.4% NH3–N, 77.5% TN, and 96.3% P removal producing effluent biological oxygen demand, COD, NH3–N,NO3–N,NO2–N, and P of <3, 3, 0.4, 5.8, 0.050, and 0.18?mg/L, respectively.  相似文献   

20.
This study demonstrated the use of batch bioreactor experiments as an evaluation tool to determine appropriate influent medium composition and concentration for effective startup of an upflow anaerobic sludge blanket (UASB) reactor. Using seed sludge from a domestic treatment plant, the weight ratio of glucose and volatile fatty acids (VFA) present in the influent synthetic medium was varied and the batch performance was assessed in terms of pH variation during the course of the experiment, chemical oxygen demand (COD) reduction, specific substrate uptake rates, methanogenic activity, and methane yield. The performance was also evaluated by increasing the concentration of influent COD. Medium composition with glucose to VFA weight ratio at or below 2:8 and COD concentration at 11?g/L was determined to be optimum for effective startup of the UASB reactors. Utilization of the optimized influent medium provided a pH variation from 6.5 to 7.8 over the length of the UASB reactor and resulted in granule formation, high methanogenic activity, and methane yield. The evaluation method provided a practical approach to determine the applicability of seed sludge from a particular source and the desired influent characteristics for reduced startup duration in UASB processes.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司    京ICP备09084417号-23

京公网安备 11010802026262号