首页 | 官方网站   微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 24 毫秒
1.
E.M. Nfah  J.M. Ngundam 《Solar Energy》2012,86(10):2935-2949
Photovoltaic hybrid systems (PVHS) with 2 days of energy autonomy are shown to be optimal options for the supply of the daily energy demands of 33 base transceiver stations of MTN Cameroon. PVHS were computed for all sites using the technical data for a 150 Wp mono-crystalline module, the site specific hourly load data, the average monthly solar radiation and temperature. Hourly solar radiation data for all sites were downloaded using the solar resource module of HOMER and geographical coordinates of the selected sites. The 3-hourly temperature data available on a website maintained NASA was used to generate average monthly hourly temperatures needed in the calculation of the output of solar modules. The energy costs and breakeven grid distances for possible power options were computed using the Net Present Value Technique and financial data for selected power system components. The results with a PV module cost of 7.5 €/Wp, a remote diesel price of 1.12 €/l, a general inflation rate of 5% and a fuel escalation of 10% showed that the annual operational times of the diesel generator were in the range 3–356 h/year with renewable energy fractions in the range 0.89–1.00. However, only 22 PVHS had two parallel battery strings as stipulated in the request for proposal launched by MTN Cameroon in 2008. The PV array sizes evaluated for the 22 PVHS were found to be the range 2.4–10.8 kWp corresponding to daily energy demands in the range 7.31–31.79 kW h/d. The energy costs and breakeven grid distances determined were in the ranges 0.81–1.32 €/kW h and 10.75–32.00 km respectively.  相似文献   

2.
Pico-hydro (pH) and photovoltaic (PV) hybrid systems incorporating a biogas generator have been simulated for remote villages in Cameroon using a load of 73 kWh/day and 8.3 kWp. Renewable energy systems were simulated using HOMER, the load profile of a hostel in Cameroon, the solar insolation of Garoua and the flow of river Mungo. For a 40% increase in the cost of imported power system components, the cost of energy was found to be either 0.352 €/kWh for a 5 kW pico-hydro generator with 72 kWh storage or 0.396 €/kWh for a 3 kWp photovoltaic generator with 36 kWh storage. These energy costs were obtained with a biomass resource cost of 25 €/tonne. The pH and PV hybrid systems both required the parallel operation of a 3.3 kW battery inverter with a 10 kW biogas generator. The pH/biogas/battery systems simulated for villages located in the south of Cameroon with a flow rate of at least 92 l/s produced lower energy costs than PV/biogas/battery systems simulated for villages in the north of Cameroon with an insolation level of at least 5.55 kWh/m2/day. For a single-wire grid extension cost of 5000 €/km, operation and maintenance costs of 125 €/yr/km and a grid power price of 0.1 €/kWh, the breakeven grid extension distances were found to be 12.9 km for pH/biogas/battery systems and 15.2 km for PV/biogas/battery systems respectively. Investments in biogas based renewable energy systems could thus be considered in the National Energy Action Plan of Cameroon for the supply of energy to key sectors involved in poverty alleviation.  相似文献   

3.
Off-grid generation options have been simulated for remote villages in Cameroon using a load of 110 kWh/day and 12 kWp. The energy costs of proposed options were simulated using HOMER, a typical village load profile, the solar resource of Garoua and the flow of river Mungo. For a 40% increase in the cost of imported power system components, the cost of energy was found to be 0.296 €/kWh for a micro-hydro hybrid system comprising a 14 kW micro-hydro generator, a 15 kW LPG generator and 36 kWh of battery storage. The cost of energy for photovoltaic (PV) hybrid systems made up of an 18 kWp PV generator, a 15 kW LPG generator and 72 kWh of battery storage was also found to be 0.576 €/kWh for remote petrol price of 1 €/l and LPG price of 0.70 €/m3. The micro-hydro hybrid system proved to be the cheapest option for villages located in the southern parts of Cameroon with a flow rate of at least 200l/s, while the PV hybrid system was the cheapest option for villages in the northern parts of Cameroon with an insolation level of at least 5.55 kWh/m2/day. For a single-wire grid extension cost of 5000 €/km, operation and maintenance costs of 125 €/yr/km and a local grid power price of 0.1 €/kWh, the breakeven grid extension distances were found to be 15.4 km for micro-hydro/LPG generator systems and 37.4 km for PV/LPG generator systems respectively. These results could be used in Cameroon's National Energy Action Plan for the provision of energy services in the key sectors involved in the fight against poverty.  相似文献   

4.
Since 2010 the Dutch photovoltaic (PV) market has been growing fast, with around doubling of installed capacity in 2011 and 2012. Four quarterly inventories have been made in 2012 for modules, inverters, and systems that are presently available for purchase in the Netherlands. We have found that the average selling price of modules, inverters, and systems decreased with 44.3, 14, and 7.3–10.2%, respectively: average selling prices are 1.26 €/Wp, 0.41 €/Wp, and 1.46 €/Wp for modules, inverters, and systems on tilted roofs, respectively, at the end of 2012. Average installation costs amount to 0.43 €/Wp. Using an energy yield of 900 kWh/kWp, 25 years system lifetime, 6% discount rate, and 1% operation and maintenance (O&M) cost, a levelized cost of electricity (LCOE) is calculated for a 2.5 kWp system to be 0.194 €/kWh for a system price of 1.98 €/Wp (including installation). Grid parity conditions are apparent, with electricity retail prices of around 0.23 €/kWh.  相似文献   

5.
Solar/diesel/battery hybrid power systems have been modelled for the electrification of typical rural households and schools in remote areas of the far north province of Cameroon. The hourly solar radiation received by latitude-titled and south-facing modules was computed from hourly global horizontal solar radiation of Garoua using Hay's anisotropic model. Using the solar radiation computed for latitude-tilted and south-facing modules, the average daytime temperatures for Garoua and parameters of selected solar modules, the monthly energy production of the solar modules was computed. It was found that BP solar modules with rated power in the range 50–180 Wp produced energy in the range 78.5–315.2 kWh/yr. The energy produced by the solar modules was used to model solar/diesel/battery hybrid power systems that could meet the energy demand of typical rural households in the range 70–300 kWh/yr. It was also found that a solar/diesel/battery hybrid power system comprising a 1440 Wp solar array and a 5 kW single-phase generator operating at a load factor of 70%, required only 136 generator h/yr to supply 2585 kWh/yr or 7 kWh/day to a typical secondary school. The renewable energy fraction obtained in all the systems evaluated was in the range 83–100%. These results show that there is a possibility to increase the access rate to electricity in the far north province without recourse to grid extension or more thermal plants in the northern grid or more independent diesel plants supplying power to remote areas of the province.  相似文献   

6.
Hydrogen energy will play a credible role to reduce gas emissions in the transportation sector, the storage of energy, and other industrial applications. Moreover, the hydrogen produced from renewable energy sources allows to minimize greenhouse gas and increase the net profit of energy projects. This paper discusses the feasibility of the conversion of solar energy into hydrogen in a Photovoltaic Hydrogen Station (PVHS) in the south of Oman. Then, the sizing of different equipment and hydrogen production estimation in a 5 MWp PVHS is presented. The analysis of the investment cost (IC), the Net Profit (NP), and the Levelized Hydrogen Energy Cost (LHEC) are discussed to investigate the benefit of the project. The energy generated from the PV system and the produced hydrogen is calculated through an analytical model. The PVHS consists of 5 MWp PV panels connected to electrolyzers through maximum power point-controlled converters. The electrolyzers convert the electrical energy and the water into hydrogen. The hydrogen compressed and stored in special tanks can be used later in many industrial applications. The system produces about 90 910 kg of hydrogen per year with an IC of 5 301 760 €. The calculated LHEC is equal to 6.2 €/kg at an interest rate of 2%. The analysis has shown promising green hydrogen production projects in Oman.  相似文献   

7.
O. U. Oparaku   《Renewable Energy》2003,28(13):2089-2098
A large proportion of the population of Nigeria reside in the rural communities. In this work, the financial costs of providing centralized (photovoltaic) PV generating system of various capacities—to satisfy different load requirements—in a remote village in Nigeria is compared with the cost of grid extension over a distance of 1.8 km. Comparison is also made with the centralised diesel generator power supply option. In addition, the costs of decentralised PV home systems are compared with those of decentralised gasoline generator systems. For all the systems, the initial capital costs and the life cycle costs over a 20-year life cycle are reported. Sensitivity analysis was performed using variations in module costs, diesel fuel prices and grid extension distance. The results suggest that PV has a remarkable potential as a cost-effective option for low-power electrical energy supply to the rural communities in the country.  相似文献   

8.
Most inhabitants of rural communities in Africa lack access to clean and reliable electricity. This has deprived the rural dwellers access to modern healthcare delivery. In this paper, an off-grid renewable energy system consisting of solar PV and wind turbine with hydrogen storage scheme has been explored to meet the electrical energy demands of a health clinic. The health clinic proposed is a group II with 10 beds located in a typical village in South Africa. First, the wind and solar energy resources of the village were analysed. Thereafter, the microgrid architecture that would meet the energy demand of the clinic (18.67 kWh/day) was determined. Some of the key results reveal that the average annual wind speed at 60 m anemometer height and solar irradiation of the village are 7.9 m/s and 4.779 kWh/m2/day, respectively. The required architecture for the clinic composes of 40 kW solar PV system, 3 numbers of 10 kW wind turbines, 8.6 kW fuel cell, 25 kW electrolyser and 40 kg hydrogen tank capacity. The capital cost of the microgrid was found to be $177,600 with a net present cost of $206,323. The levelised cost of energy of the system was determined to be 2.34 $/kWh. The project has a breakeven grid extension distance of 8.81 km. Since this distance is less than the nearest grid extension distance of 21.35 km, it is established that the proposed renewable energy microgrid with a hydrogen storage system is a viable option for the rural community health clinic.  相似文献   

9.
Renewable energy resources play a very important rule these days to assist the conventional energy systems for doing its function in the UAE due to high greenhouse gas (GHG) emissions and energy demand. In this paper, the analysis and performance of integrated standalone hybrid solar PV, fuel cell and diesel generator power system with battery energy storage system (BESS) or supercapacitor energy storage system (SCESS) in Khorfakkan city, Sharjah were presented. HOMER Pro software was used to model and simulate the hybrid energy system (HES) based on the daily energy consumption for Khorfakkan city. The simulation results show that using SCESS as an energy storage system will help the performance of HES based on the Levelized cost of energy (LCOE) and greenhouse gas (GHG) emissions. The HES with SCESS has renewable fraction (68.1%) and 0.346 $/kWh LCOE. The HES meets the annual AC primary load of the city (13.6 GWh) with negligible electricity excess and with an unmet electrical load of 1.38%. The reduction in GHG emissions for HES with SCESS was 83.2%, equivalent to saving 814,428 gallons of diesel.  相似文献   

10.
The economics of stand-alone photovoltaic power system is studied to test its feasibility in remote and rural areas of Bangladesh and to compare renewable generators with non-renewable generators. The life cycle cost of these generators are determined using the method of net present value analysis. It is found that the life cycle cost of this experimental PV system is Tk. 43.40/kWh for one family (US $1.00 = Bangladeshi taka Tk.50.00). The life cycle cost for grid electricity is Tk. 20.00/kWh and Tk. 7.75/kWh for generation of fuel costs of Tk. 6.80/kWh and Tk. 0.47/kWh respectively. For a village 1 km away from the distribution line, this cost becomes Tk. 125.00/kWh for a family. For petrol generator life cycle cost is Tk. 50.00/kWh at fuel price of Tk. 22.00 per litre. For diesel generator life cycle cost is found to be Tk. 46.10/kWh at fuel cost of Tk. 15.00 per litre. It is observed that the life cycle cost of one unit of energy from grids that are 1 km away from a village is much higher than the cost of energy from a PV system. Thus, the use of PV system is economically feasible in rural villages and remote areas of Bangladesh, where grid electricity is not available.  相似文献   

11.
The role and share of photovoltaic (PV) generated electricity in our nation's future energy arsenal is primarily dependent on its future production cost. This paper provides a framework for obtaining a minimum achievable electrical generating cost (a lower bound) for fixed, flat-plate photovoltaic systems. A cost of 2.8¢/kWh (1990$) was derived for a plant located in Southwestern US sunshine using a cost of money of 8%. In addition, a value of 22¢/Wp (1990$) was estimated as a minimum module manufacturing cost/price.  相似文献   

12.
A techno-economic analysis of a hydrogen valley is carried out in this paper. A hydrogen generator fed by a wind farm (WF) and/or a photovoltaic (PV) plant supplies four end-users: a stationary fuel cell, a hydrogen refuelling station, the injection in the natural gas pipeline and, in case of sufficient hydrogen surplus, a biological hydrogen methanation (BHM) process.The results demonstrated that an efficiency improvement and a reduction in hydrogen production costs arise from a balanced supply from wind and solar energy. Without the inclusion of a BHM process, hydrogen production costs lower than 7 €/kg were achieved by a hydrogen generator using 10–12% of the PV + WF annual energy with a PV share of 20%–50%. The hydrogen production costs were further reduced to 5 €/kg by introducing a BHM process and increasing the percentage of electrical energy supplied by the PV + WF system to 25% of its overall production.  相似文献   

13.
Renewable energy sources have been taken the place of the traditional energy sources and especially rapidly developments of photovoltaic (PV) technology and fuel cell (FC) technology have been put forward these renewable energy sources (RES) in all other RES. PV systems have been started to be used widely in domestic applications connected to electrical grid and grid connected PV power generating systems have become widespread all around the world. On the other hand, fuel cell power generating systems have been used to support the PV generating so hybrid generation systems consist of PV and fuel cell technology are investigated for power generating. In this study, a grid connected fuel cell and PV hybrid power generating system was developed with Matlab Simulink. 160 Wp solar module was developed based on solar module temperature and solar irradiation by using real data sheet of a commercial PV module and then by using these modules 800 Wp PV generator was obtained. Output current and voltage of PV system was used for input of DC/DC boost converter and its output was used for the input of the inverter. PV system was connected to the grid and designed 5 kW solid oxide fuel cell (SOFC) system was used for supporting the DC bus of the hybrid power generating system. All results obtained from the simulated hybrid power system were explained in the paper. Proposed model was designed as modular so designing and simulating grid connected SOFC and PV systems can be developed easily thanks to flexible design.  相似文献   

14.
This paper presents a methodology to optimise a hybrid solar Photovoltaic—wind turbine generator for the villages situated in the remote areas, especially coastal regions of India. Owing to good insolation and wind density, the hybrid system composed of 6 photovoltaic (PV) modules, one wind turbine and 3 batteries are sufficient to fulfil all the necessary power demand without interruption for an Indian village. The analytical analysis shows that the system having lifespan of 30 years has return on capital, cost of power produced and cost of the hybrid solar-wind generators as 4.08%, € 0.155/kWh and € 4723.5/kWh respectively. The energy payback time is 2.47 years and will lead to earn € 28.52 every year of carbon credits.  相似文献   

15.
The burning of depleting fossil fuels for power generation has detrimental impact on human life and climate. In view of this, renewable solar energy sources are being increasingly exploited to meet the energy needs. Moreover, solar photovoltaic (PV)–diesel hybrid system technology promises lot of opportunities in remote areas which are far from utility grid and are driven by diesel generators. Integration of PV systems with the diesel plants is being disseminated worldwide to reduce diesel fuel consumption and to minimize atmospheric pollution. The Kingdom of Saudi Arabia (K.S.A.) being endowed with high intensity of solar radiation, is a prospective candidate for deployment of PV systems. Also, K.S.A. has large number of remote scattered villages. The aim of this study is to analyze solar radiation data of Rafha, K.S.A., to assess the techno-economic feasibility of hybrid PV–diesel–battery power systems to meet the load requirements of a typical remote village Rawdhat Bin Habbas (RBH) with annual electrical energy demand of 15,943 MWh. Rafha is located near RBH. The monthly average daily global solar radiation ranges from 3.04 to 7.3 kWh/m2. NREL's HOMER software has been used to perform the techno-economic evaluation. The simulation results indicate that for a hybrid system composed of 2.5 MWp capacity PV system together with 4.5 MW diesel system (three 1.5 MW units) and a battery storage of 1 h of autonomy (equivalent to 1 h of average load), the PV penetration is 27%. The cost of generating energy (COE, US$/kWh) from the above hybrid system has been found to be 0.170$/kWh (assuming diesel fuel price of 0.1$/l). The study exhibits that the operational hours of diesel generators decrease with increase in PV capacity. The investigation also examines the effect of PV/battery penetration on COE, operational hours of diesel gensets. Concurrently, emphasis has been placed on: un-met load, excess electricity generation, percentage fuel savings and reduction in carbon emissions (for different scenarios such as: PV–diesel without storage, PV–diesel with storage, as compared to diesel-only situation), COE of different hybrid systems, etc. The decrease in carbon emissions by using the above hybrid system is about 24% as compared to the diesel-only scenario.  相似文献   

16.
The current paper presents the economic evaluation of a two-stage Solar Organic Rankine Cycle (SORC) for using the mechanical energy produced during the thermodynamic process to drive a Reverse Osmosis (RO) desalination unit. The developed integrated system is briefly analysed and the specific fresh water cost, as well as the cost of energy is calculated. The economic assessment results are compared with those obtained from a low-temperature SORC-RO and two alternative variants of PhotoVoltaic RO (PV–RO) systems (with and without batteries). It is found that the critical fresh water cost for the system under consideration is 7.48 €/m3 of permeate water and the cost of energy equals to 2.74 €/kWh, when the water cost is slightly higher than the critical one (meaning 8 €/m3). These values are considered satisfactory enough, in comparison to the other autonomous desalination technologies. Additionally, the specific fresh water cost of the developed technology was calculated to be 6.85 €/m3, being very close to the values of the PV–RO systems. The variant of two-stage SORC significantly improves the efficiency and reduces the cost of the already developed prototype system (single-stage low-temperature SORC for RO desalination), because the specific cost is found to be much lower and taking into consideration its reliability, this technology can constitute an alternative desalination method competitive to the PV–RO on the basis of techno-economic feasibility.  相似文献   

17.
Shafiqur Rehman  Luai M. Al-Hadhrami   《Energy》2010,35(12):4986-4995
This study presents a PV–diesel hybrid power system with battery backup for a village being fed with diesel generated electricity to displace part of the diesel by solar. The hourly solar radiation data measured at the site along with PV modules mounted on fixed foundations, four generators of different rated powers, diesel prices of 0.2–1.2US$/l, different sizes of batteries and converters were used to find an optimal power system for the village. It was found that a PV array of 2000 kW and four generators of 1250, 750, 2250 and 250 kW; operating at a load factor of 70% required to run for 3317 h/yr, 4242 h/yr, 2820 h/yr and 3150 h/yr, respectively; to produce a mix of 17,640 MWh of electricity annually and 48.33 MWh per day. The cost of energy (COE) of diesel only and PV/diesel/battery power system with 21% solar penetration was found to be 0.190$/kWh and 0.219$/kWh respectively for a diesel price of 0.2$/l. The sensitivity analysis showed that at a diesel price of 0.6$/l the COE from hybrid system become almost the same as that of the diesel only system and above it, the hybrid system become more economical than the diesel only system.  相似文献   

18.
This work looks at the feasibility of a standalone hybrid power generation system for providing power to a rural community in the Pacific Islands. The optimization and sensitivity analysis of a proposed PV/Wind/Diesel hybrid System is performed together with economic analysis. We have used HOMER, a sizing and optimization tool for distributed power system, developed by National Renewable Energy Laboratory (NREL) for our analysis. The sensitivity analysis was done using wind speed data and diesel price as variables. An Ice storage facility having a corrected mean daily load of 60 kWh/day was considered as the stand-alone load. The life cycle cost analysis was done for a number of scenarios with different renewable energy contribution to the total electricity produced.  相似文献   

19.
Solar and wind energies are likely to play an important role in the future energy generation in Oman. This paper utilizes average daily global solar radiation and sunshine duration data of 25 locations in Oman to study the economic prospects of solar energy. The study considers a solar PV power plant of 5-MW at each of the 25 locations. The global solar radiation varies between slightly greater than 4 kWh/m2/day at Sur to about 6 kWh/m2/day at Marmul while the average value in the 25 locations is more than 5 kWh/m2/day. The results show that the renewable energy produced each year from the PV power plant varies between 9000 MWh at Marmul and 6200 MWh at Sur while the mean value is 7700 MWh of all the 25 locations. The capacity factor of PV plant varies between 20% and 14% and the cost of electricity varies between 210 US$/MWh and 304 US$/MWh for the best location to the least attractive location, respectively. The study has also found that the PV energy at the best location is competitive with diesel generation without including the externality costs of diesel. Renewable energy support policies that can be implemented in Oman are also discussed.  相似文献   

20.
Results of a techno-economic evaluation of biomass gasifier based projects for decentralized power supply for remote locations in India are presented. Contributions of different components of diesel engine generator (DG) sets, dual fuel (DF) engine generator sets and 100% producer gas (HPG) engine generator sets to their capital costs as well as to the levelized unit cost of electricity (LUCE) delivered by the same have been analyzed. LUCE delivered to the consumers has been estimated to be varying in the range of Rs. 13.14–24.49/kWh (US$1 0.30–0.55/kWh) for DF BGPP. LUCE increases significantly if BGPP is operated at part loads. Presently available 40 kW capacity HPG systems in India are expected to be financially competitive with a DG set of equivalent capacity beyond a break-even diesel price of Rs. 34.70/l. It is expected to be financially more attractive than an equivalent capacity DF BGPP for diesel prices of more than Rs. 44.29/l. In certain specific conditions operating two smaller capacity systems has been found to be attractive as against a single larger capacity system.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司    京ICP备09084417号-23

京公网安备 11010802026262号