首页 | 官方网站   微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Passive treatment of ferruginous mine waters using high surface area media   总被引:1,自引:0,他引:1  
Jarvis AP  Younger PL 《Water research》2001,35(15):3643-3648
Rapid oxidation and accretion of iron onto high surface area media has been investigated as a potential passive treatment option for ferruginous. net-alkaline minewaters. Two pilot-scale reactors were installed at a site in County Durham, UK. Each 2.0 m high cylinder contained different high surface area plastic trickling filter media. Ferruginous minewater was fed downwards over the media at various flow-rates with the objective of establishing the efficiency of iron removal at different loading rates. Residence time of water within the reactors was between 70 and 360 s depending on the flow-rate (1 and 12 l/min, respectively). Average influent total iron concentration for the duration of these experiments was 1.43 mg/l (range 1.08-1.84 mg/l; n = 16), whilst effluent iron concentrations averaged 0.41 mg/l (range 0.20-1.04 mg/l; n = 15) for Reactor A and 0.38 mg/l (range 0.11-0.93 mg/l; n = 16) for Reactor B. There is a strong correlation between influent iron load and iron removal rate. Even at the highest loading rates (approximately 31.6 g/day) 43% and 49% of the total iron load was removed in Reactors A and B, respectively. At low manganese loading rates (approximately 0.50-0.90 g/day) over 50% of the manganese was removed in Reactor B. Iron removal rate (g/m3/d) increases linearly with loading rate (g/day) up to 14 g/d and the slope of the line indicates that a mean of 85% of the iron is removed. In conclusion. it appears that the oxidation and accretion of ochre on high surface area media may be a promising alternative passive technology to constructed wetlands at certain sites.  相似文献   

2.
A full‐scale wastewater treatment plant with a 5500 population equivalent was retrofitted with a pre‐denitrification‐submerged anoxic filter (SAnoF) in order to achieve new total nitrogen (TN) consent of 35 mg/L. A 36 m3 SAnoF was installed downstream the primary settling tanks. The optimal operation of the anoxic SAnoF was investigated by varying the recirculation ratio, the carbon‐to‐nitrate ratio, and the hydraulic retention time. After stable operation was achieved, nitrate was removed by 80% at a loading of 0.5 kg NO3/m3 day and a retention time of 60 min. The SAnoF presented a number of advantages, including the use of internal carbon for denitrification, decrease of carbon load to the trickling filter by 30%, and production of alkalinity required for nitrification in the trickling filter (11 mg CaCO3/mg NH4 removed). Overall, the SAnoF was satisfactory and the effluent TN concentration reached 20–25 mg TN/L.  相似文献   

3.
Hidaka T  Tsuno H  Kishimoto N 《Water research》2003,37(17):4259-4269
A pre-coagulation and bio-filtration process for advanced treatment of sewage was developed and experimentally discussed with a pilot plant. The bio-filtration unit consists of a denitrification filter, a nitrification filter with side stream to the denitrification filter, and a polishing filter with anoxic and aerobic parts. Concentrations of SS, T-COD(Cr), T-carbonaceous BOD, T-N and T-P in the effluent were stably kept at less than 3, 20, 5mg/L, 2mg N/L and 0.2mg P/L, respectively, and transparency at higher than 100 cm, under total hydraulic retention time of 3.2h in the bio-filtration parts (filter-bed). ORP in an anoxic tank before a nitrification tank should be at a low level of less than -120 mV to keep remaining NO(-)(x) - N less than 1mg N/L, but must be maintained at a level higher than -150 mV. The maximum nitrogen-loading rate under a water temperature of 18 degrees C should be less than 0.25 kg N/(m(3)-filter-bed.d). Concentrations of microorganisms kept in the reactors were as high as 4000-5000 mg COD/L-filter-bed. Denitrification activity of 0.4 or 0.7 kg N/(m(3)-filter-bed.d), and nitrification activity of 0.3 kg N/(m(3)-filter-bed.d) were obtained, respectively, under a water temperature of about 18 degrees C. Backwashing in each tank as well as methanol addition and aeration in the polishing filter were operated successfully by the automatic control systems. These results proved that this process is applicable to advanced treatment of sewage with easy maintenance.  相似文献   

4.
An empirical model has been developed to predict the effluent ammoniacal nitrogen concentration from structured cross flow plastic media trickling filters operated over the range of BOD loadings 0.12–0.38 kg/m3/day and ammoniacal nitrogen loadings of 0.06–0.23 kg/m3/day. The model gives good predictions based on 24‐h average effluent concentrations over a range of filter depths, organic and hydraulic loading rates. When incorporated with suitable hydraulic models, effluent ammoniacal concentration can be predicted through the diurnal range. The data gathering for the model included depth profiles on three filters. These have shown that at all but the very highest BOD loadings, nitrification commences from the very top of the filter in the presence of soluble BOD loadings previously thought to preclude the development of nitrifying biomass. Several reasons have been proposed to explain this, with the key argument being that the efficient oxygen transfer afforded by the media design is sufficient to satisfy heterotroph and autotroph oxygen demand simultaneously.  相似文献   

5.
H Simsek  M Kasi  T Wadhawan  C Bye  M Blonigen  E Khan 《Water research》2012,46(16):5115-5126
Dissolved organic nitrogen (DON) represents a significant portion of nitrogen in the final effluent of wastewater treatment plants (WWTPs). Biodegradable portion of DON (BDON) can support algal growth and/or consume dissolved oxygen in the receiving waters. The fate of DON and BDON has not been studied for trickling filter WWTPs. DON and BDON data were collected along the treatment train of a WWTP with a two-stage trickling filter process. DON concentrations in the influent and effluent were 27% and 14% of total dissolved nitrogen (TDN). The plant removed about 62% and 72% of the influent DON and BDON mainly by the trickling filters. The final effluent BDON values averaged 1.8 mg/L. BDON was found to be between 51% and 69% of the DON in raw wastewater and after various treatment units. The fate of DON and BDON through the two-stage trickling filter treatment plant was modeled. The BioWin v3.1 model was successfully applied to simulate ammonia, nitrite, nitrate, TDN, DON and BDON concentrations along the treatment train. The maximum growth rates for ammonia oxidizing bacteria (AOB) and nitrite oxidizing bacteria, and AOB half saturation constant influenced ammonia and nitrate output results. Hydrolysis and ammonification rates influenced all of the nitrogen species in the model output, including BDON.  相似文献   

6.
This work aimed to assess the technical and energetic feasibility of a passively aerated laboratory-scale trickling filter, configured as a two-stage system, to produce urban wastewater (UWW) reusable in agriculture. The trickling filter was fed continuously with high-strength UWW at four hydraulic retention times (HRTs), that is, 10, 5, 2 and 1 day, corresponding to organic loading rates (OLRs) of 0.1, 0.2, 0.5 and 0.9 kg COD/m3/d, respectively. The results revealed a good performance in organic load removal and nitrification at the four HRTs. The trickling filter showed high organic pollutant removal efficiencies of up to 93%, 94% and 98% for chemical oxygen demand (COD), BOD5 and total suspended solid (TSS), respectively, as well as high ammonia nitrogen removal above 96% at the shortest HRT of 1 day. All physicochemical parameters were significantly lower than the allowable limits set out in ISO 16075 for category C (non-food crop irrigation) irrigation water. The reuse of treated UWW in irrigation led to germination indexes and growth parameters of triticale (Triticosecale Wittm.) almost equal to those obtained using tap water. Energy use was found to be about 0.2754 kWh/m3 of treated wastewater, making it competitive with trickling filter plants reported in the literature. The simplicity and energy efficiency of the developed trickling filter system, combined with its capacity for almost full nitrification, make it appealing for sewage treatment in small communities in developing countries.  相似文献   

7.
Effect of backwashing on perchlorate removal in fixed bed biofilm reactors   总被引:2,自引:0,他引:2  
Choi YC  Li X  Raskin L  Morgenroth E 《Water research》2007,41(9):1949-1959
The influence of backwashing on biological perchlorate reduction was evaluated in two laboratory scale fixed bed biofilm reactors using 1- or 3-mm glass beads as support media. Influent perchlorate concentrations were 50 microg/L and acetate was added as the electron donor at a concentration of 2 mg C/L. Perchlorate removal was evaluated at various influent dissolved oxygen (DO) concentrations. Complete perchlorate removal was achieved with an influent DO concentration of 1mg/L resulting in bulk phase DO concentrations below the detection limit of 0.01 mg/L. The influence of increasing influent DO concentrations for 12 h periods was evaluated before and after individual backwash events. Partial perchlorate removal was achieved with an influent DO concentration of 3.5 mg/L before a strong backwash (bulk phase DO concentrations of approximately 0.2mg/L), while no perchlorate removal was observed after the strong backwash at the same influent DO level (bulk phase DO concentrations of approximately 0.8 mg/L). The immediate effect of backwashing depended on influent DO concentrations. With influent DO concentrations of 1 mg/L, strong backwashing resulted in a brief (<12 h) increase of effluent perchlorate concentrations up to 20 microg/L; more pronounced effects were observed with influent DO concentrations of 3mg/L. Daily weak backwashing had a small and, over time, decreasing negative influence on perchlorate reduction, while daily strong backwashing ultimately resulted in the breakdown of perchlorate removal with influent DO concentrations of 3 mg/L.  相似文献   

8.
Hu Z  Gagnon GA 《Water research》2006,40(7):1474-1480
The main objective of this paper was to evaluate the effectiveness of silica sand, crushed glass, peat, and geotextile as a medium in RBFs in the removal for organic matter, nutrients and bacteria from domestic wastewater based on a field-scale study. In particular, this field-scale study was conducted to treat domestic wastewater from a small community of 10 households from the Municipality of Lunenburg, Nova Scotia, Canada. The average influent 5d biochemical oxygen demand (BOD(5)) and total suspended solids (TSS) concentrations into the field filter system were 381+/-64 (mean+/-standard deviation) and 46+/-21 mg/L, respectively. The results showed that crushed glass could be an effective medium in RBFs since the crushed glass filter produced stable effluent BOD(5) and TSS concentrations of less than 20mg/L. Geotextile was found to be another successful alternative filter medium with the effluent BOD(5) and TSS of 18+/-11 and 11+/-7 mg/L, respectively, even though the porosity of geotexitle filter was as high as 0.90. Peat was not able to provide efficient performance due to its poor BOD(5) and NH(4)(+)-N removals. This study measured the water quality variation at different components of the RBFs. The results of this study showed that the recirculation tank was the main facilitator of the denitrification process. In addition, this study found that RBFs could efficiently treat domestic wastewater for BOD(5) removal under the organic loading rates as high as 0.070 kg/m(2)/d.  相似文献   

9.
The trickling filter/solids contact process has been shown to be an excellent means of upgrading biological filter plants in North America, and about 100 plants have been built since 1979 in both cold and warm climates, and on both large and small works. A variety of effluent requirements has been satisfied consistently, including monthly average BOD and SS concentrations of 10 mg/l and 10 mg/l respectively. Key design features are described, including the use of an aerated solids contact tank to flocculate dispersed solids. Also, a flocculator-clarifier with special design features allows the use of high overflow rates and smaller sedimentation tanks.  相似文献   

10.
Downing LS  Nerenberg R 《Water research》2008,42(14):3697-3708
The hybrid (suspended and attached growth) membrane biofilm process (HMBP) is a novel method to achieve total nitrogen removal from wastewater. Air-filled hollow-fiber membranes are incorporated into an activated sludge tank, and a nitrifying biofilm develops on the membranes, producing nitrite and nitrate. By suppressing bulk aeration, the bulk liquid becomes anoxic, and the nitrate/nitrite can be reduced with influent BOD. The key feature that distinguishes the HMBP from other membrane-aerated processes is that it is hybrid; heterotrophic bacteria are kept mainly in suspension by maintaining low bulk liquid BOD concentrations. We investigated the HMBP's performance under a variety of BOD and ammonium loadings, and determined the dominant mechanisms of nitrogen removal. Suspended solids increased with the BOD loadings, maintaining low bulk liquid BOD concentrations. As a result, nitrification rates were insensitive to the BOD loadings, remaining at 1gNm(-2)day(-1) for BOD loadings ranging from 4 to 17gBODm(-2)day(-1). Nitrification rates decreased during short-term spikes in bulk liquid BOD concentrations. Shortcut nitrogen removal was confirmed using microsensor measurements, showing that nitrite was the dominant form of oxidized nitrogen produced by the biofilm. Fluorescence in situ hybridization (FISH) showed that ammonia oxidizing bacteria (AOB) were dominant throughout the biofilm, while nitrite oxidizing bacteria (NOB) were only present in the deeper regions of the biofilm, where the oxygen concentration was above 2mg/L. Denitrification occurred mainly in the suspended phase, instead of in the biofilm, decreasing the potential for biofouling. When influent BOD concentrations were sufficiently high, full denitrification occurred, with total nitrogen (TN) removal approaching 100%. These results suggest that the process is well-suited for achieving concurrent BOD and TN removal in activated sludge.  相似文献   

11.
Kinetic model of autotrophic denitrification in sulphur packed-bed reactors   总被引:7,自引:0,他引:7  
Koenig A  Liu LH 《Water research》2001,35(8):1969-1978
Autotrophic denitrification of synthetic wastewater by Thiobacillus denitrificans in upflow sulphur packed-bed reactors was studied in order to establish the process kinetics for prediction of effluent concentration. Elemental sulphur particles of different size served as energy substrate as well as the physical support for the microbial biofilm. Experiments were performed under operating conditions of (i) different flow rates at constant influent nitrate concentration; and (ii) different influent nitrate concentrations at constant flow rate. The experimental results show that autotrophic denitrification rates in upflow sulphur packed-bed reactors can be described by a half-order kinetic model for biofilms. It was found that the half-order kinetic constants of upflow packed-bed reactors are 2.94-3.60, 1.47-2.04, and 1.12-1.29 mg1/2/L1/2 h for sulphur particle sizes of 2.8-5.6, 5.6-11.2, and 11.2-16 mm, respectively. The half-order kinetic constants could be related to the specific surface area of the reactor media by a simple equation. Successful application of the half-order reaction rate model was demonstrated for an actual wastewater (nitrified leachate). A comparison with the literature showed that the half-order reaction rate constants for autotrophic denitrification using elemental sulphur are approximately one order of magnitude lower than those of heterotrophic denitrification. An improved stoichiometric equation for autotrophic denitrification using elemental sulphur as electronic donor is also proposed.  相似文献   

12.
DeniteFilter(反硝化滤池)是将生物脱氮及过滤功能合二为一的处理单元,一池多用,兼具除磷脱氮功能。针对TN达标难点,无锡市芦村污水处理厂四期工程深度处理中采用了该工艺,运行中发现,投加理论碳源量时,出水TN不能达标,经分析,是二沉池出水DO及滤池进水DO上升消耗了碳源所致,因此,重新核定了碳源投加量。运行结果表明,增加碳源投加量后出水TN达标。建议通过改进滤池出水堰形状和增加碳源投加精确控制系统来削减碳源投量。  相似文献   

13.
Rabah FK  Dahab MF 《Water research》2004,38(17):3719-3728
Two laboratory-scale high performance fluidized bed biofilm reactors (FBBR) with sand as the biofilm carrier were used to investigate the denitrification of high-strength nitrate wastewater with specific emphasis on the effect the nitrogen loading rate and the superficial velocity (V(s)). The results demonstrated that the FBBR system is capable of efficiently handling an exceptionally high nitrate nitrogen concentration of 1000 mg N/L. At a loading rate of 6.3 kg-N/m(3)(bed).d almost complete denitrification was achieved with a removal efficiency of 99.8% and an effluent concentration of 2mg N/L at V(s) values of 45, 55 and 65 m/h. The maximum efficient loading rate (R(max)) at which the US drinking water nitrate-nitrogen standard concentration of 10mg N/L would be exceeded was found to be a function of the applied V(s). The R(max) was found to be 12 kg-N/m(3)(bed).d at a V(s) value of 45 m/h. As V(s) was increased to 55 and 65 m/h, the optimum R(max) dropped to 9.5 and 8 kg-N/m(3)(bed).d, respectively. Higher denitrification rates were achieved at relatively lower V(s). However, there is a minimum practical velocity below which agglomeration of biomass would occur. The suspended solids concentration in the effluent was below 30 mg/L throughout the study.  相似文献   

14.
In the modified Ludzack–Ettinger process, high‐energy input is required in a nitrification tank. To address this issue, a new biological nitrification–denitrification system was constructed with a trickling filter for nitrification. The effects of recirculation rate of nitrified liquor and temperature through the treatment of municipal wastewater were evaluated. The highest DN removal efficiency was observed at 6.5 h of hydraulic retention in the denitrification tank and 350% of recirculation rate of nitrified liquid against the influent flow rate. The DN removal efficiencies did not reach theoretical values for all conditions tested because the COD/N ratios in the influent often decreased to less than 5 g‐COD/g‐N and temperatures dropped to less than 15°C in winter. The former inhibited the denitrification process and the latter significantly decreased the bioactivity of nitrifying bacteria. As such, this system is suitable in tropical and subtropical areas with annual minimum temperatures of over 15°C.  相似文献   

15.
Demonstration of mass transfer and pH effects in a nitrifying biofilm   总被引:7,自引:0,他引:7  
H. Siegrist  W. Gujer 《Water research》1987,21(12):1481-1487
A bench-scale nitrifying trickling filter (surface AREA = 0.5 m2) was developed to permit evaluation of diffusion of oxygen within a biofilm, the pH dependence of ammonium oxidation and external mass transfer. In addition, a biofilm model was developed and verified for homogeneous nitrifying biofilms of varied thickness and for thin nitrifying biofilms covered by heterotrophic biofilms. The model uses literature values for the pH dependence of Monod coefficients for Nitrosomonas and Nitrobacter.

The diffusion coefficient of oxygen in the biofilm was found to be 40–80% of the value in pure water. Due to mass transfer resistance, the biomass ·sees” a lower pH than is measured in the water film passing over it. The surface uptake rate of ammonia is used as an indicator of pH gradients within the biofilm system. With the help of oxygen limitation experiments, the location of nitrifying biomass within mixed biofilms (heterotrophic, autotrophic) can be determined.

The biofilm model predicts ammonium uptake rate of a trickling filter as a function of the bicarbonate concentration in the water film.  相似文献   


16.
The removal of gaseous ammonia in a system consisting of a biotrickling filter, a denitrification reactor and a polishing bioreactor for the trickling liquid was investigated. The system allowed sustained treatment of ammonia while preventing biological inhibition by accumulating nitrate and nitrite and avoiding generation of contaminated water. All bioreactors were packed with cattle bone composite ceramics, a porous support with a large interfacial area. Excellent removal of ammonia gas was obtained. The critical loading ranged from 60 to 120 gm(-3)h(-1) depending on the conditions, and loadings below 56 gm(-3)h(-1) resulted in essentially complete removal of ammonia. In addition, concentrations of ammonia, nitrite, nitrate and COD in the recycle liquid of the inlet and outlet of each reactor were measured to determine the fate of nitrogen in the reactor, close nitrogen balances and calculate nitrogen to COD ratios. Ammonia absorption and nitrification occurred in the biotrickling filter; nitrate and nitrite were biologically removed in the denitrification reactor and excess dissolved COD and ammonia were treated in the polishing bioreactor. Overall, ammonia gas was very successfully removed in the bioreactor system and steady state operation with respect to nitrogen species was achieved.  相似文献   

17.
UBAF/化学除磷处理宾馆污水并回用   总被引:3,自引:0,他引:3  
济南南郊宾馆的排水量及杂用水量均较大,为此采用水解—上向流曝气生物滤池(UBAF)—纤维过滤器(加药除磷)工艺处理宾馆污水,通过将UBAF的滤层分成缺氧区和好氧区,使UBAF具有了碳化、硝化与反硝化的功能,其对氨氮的去除率>85%,对COD的去除率在80%左右,在回流比为50%的条件下对总氮的去除率约30%。UBAF出水投加硫酸铝后进行纤维过滤除磷,在投量为20mg/mgTP的条件下可确保出水TP<1mg/L。  相似文献   

18.
Environmental fate of Triclosan in the River Aire Basin, UK   总被引:5,自引:0,他引:5  
The concentrations and removal rate of Triclosan, an antibacterial ingredient in consumer products, were measured at advanced trickling filter (TF) and activated sludge (AS) wastewater treatment plants (WWTPs) in the River Aire basin in the UK in September 2000. Additionally, the in-stream removal of Triclosan was measured directly in Mag Brook, the stream receiving the treated effluent from the TF plant, using a fluorescent dye tracer to determine the water plug travel times. The in-stream removal of the dissolved and un-ionized (i.e. bioavailable) fraction of the compound was measured using semipermeable membrane devices (SPMDs) deployed at various distances downstream from the WWTP discharge point. The estimated removal rates were used in the GREAT-ER (Geography-Referenced Regional Exposure Assessment Tool for European Rivers) model to predict the site-specific distribution of Triclosan concentrations in the Aire basin as well as to calculate regional concentrations. High WWTP (approximately 95%) and in-stream (0.21-0.33 h-1) removal rates of Triclosan in Mag Brook confirm that this chemical is rapidly eliminated from the aquatic environment.  相似文献   

19.
A nitrification model for a tertiary trickling filter is developed based on stoichiometry, Fick's Law and Monod kinetics. The design of tertiary trickling filters for nitrification is discussed, with special emphasis on: residual ammonium concentration, recirculation, reactors in series, residual alkalinity, residual nitrite concentration and effects of temperature on reactor performance. Wherever possible the theoretical predictions are compared with experimental results.  相似文献   

20.
Choi YC  Li X  Raskin L  Morgenroth E 《Water research》2008,42(13):3425-3434
Fixed bed biofilm reactors with granular activated carbon (GAC) or glass beads as support media were used to evaluate the influence of short-term (12h) and long-term (23 days) increases of influent dissolved oxygen (DO) concentrations on biological perchlorate removal. The goal was to evaluate the extent by which chemisorption of oxygen to GAC can enhance the stability of biological perchlorate reduction. Baseline influent concentrations were 50 microg/L of perchlorate, 2 mg/L of acetate as C, and 1mg/L of DO. Perchlorate removal in the glass bead reactor seized immediately after increasing influent DO concentrations from 1 to 4 mg/L since glass beads have no sorptive capacity. In the biologically active carbon (BAC) reactor, chemisorption of oxygen to GAC removed a substantial fraction of the influent DO, and perchlorate removal was maintained during short-term increases of influent DO levels up to 8 mg/L. During long-term exposure to influent DO concentrations of 8.5mg/L, effluent perchlorate and DO concentrations increased slowly. Subsequent exposure of the BAC reactor bed to low DO concentrations partially regenerated the capacity for oxygen chemisorption. Microbial analyses indicated similar microbial communities in both reactors, which confirmed that the differences in reactor performance during dynamic loading conditions could be attributed to the sorptive properties of GAC. Using a sorptive biofilm support medium can enhance biological perchlorate removal under dynamic loading conditions.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司    京ICP备09084417号-23

京公网安备 11010802026262号