首页 | 官方网站   微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 312 毫秒
1.
OBJECTIVES: This study was designed to examine whether oversized implantation of the new, less shortening Wallstent provides a more favorable long-term clinical and angiographic outcome in chronic total occlusions than does conventional coronary balloon angioplasty. BACKGROUND: Restenosis and reocclusion remain major limitations of balloon angioplasty for chronic total occlusions. Enforced mechanical remodeling by implantation of the oversized Wallstent may prevent elastic recoil and improve accommodation of intimal hyperplasia. METHODS: Lumen dimension was measured by a computer-based quantitative coronary angiography system (CAAS II). These measurements (before and after intervention and at 6-month follow-up) were compared between the groups with Wallstent implantation (20 lesions, 20 patients) and conventional balloon angioplasty (266 lesions, 249 patients) for treatment of chronic total occlusion. Acute gain (minimal lumen diameter after intervention minus that before intervention), late loss (minimal lumen diameter after intervention minus that at follow-up) and net gain (acute gain minus late loss) were examined. RESULTS: Wallstent deployment was successful in all patients. High pressure intra-Wallstent balloon inflation (mean +/- SD 14 +/- 3 atm) was performed in all lesions. Although vessel size did not differ between the Wallstent and balloon angioplasty groups, acute gain was significantly greater in the Wallstent group (2.96 +/- 0.55 vs. 1.61 +/- 0.34 mm, p < 0.0001). Although late loss was also significantly larger in the Wallstent group (0.81 +/- 0.95 vs. 0.43 +/- 0.68 mm, p < 0.05), net gain was still significantly greater in this group (2.27 +/- 1.00 vs. 1.18 +/- 0.69 mm, p < 0.0001). Angiographic restenosis (> or = 50% diameter stenosis) occurred at 6 months in 29% of lesions in the Wallstent group and in 45% of those in the balloon angioplasty group (p = 0.5150). CONCLUSIONS: Implantation of the oversized Wallstent, with full coverage of the lesion length, ensures resetting of the vessel size to its original caliber before disease and allows greater accommodation of intimal hyperplasia and chronic vessel recoil. Wallstent implantation provides a more favorable short- and long-term clinical and angiographic outcome than does conventional balloon angioplasty for chronic total occlusions.  相似文献   

2.
Restenosis remains a major limitation of coronary angioplasty in spite of major advances in techniques and technology. Recent studies have demonstrated that ionizing radiation may limit the degree of this problem. Gamma radiation has been shown to be effective in reducing in stent restenosis in humans, and beta radiation following encouraging results in animals has been shown to be feasible in humans. The objective of this study was to assess the feasibility of a 5 F non-centered catheter to deliver beta radiation emitting seeds to the lesion site post angioplasty and its effect on restenosis. Following successful angioplasty, patients were randomized to treatment with 12, 14 or 16 Gy at the angioplasty site. This was delivered with a 5 F non-centered catheter. Twelve beta radiation emitting seeds (90Sr/Y) were delivered to an area 3 cm in length to cover the angioplasty site. Angiographic follow-up was performed at 6 months. Baseline and follow-up angiograms were performed by blinded investigators at a core laboratory. This interim report comprises the first 35 patients to complete 6-month angiographic follow-up. There were no major radiation incidents. Four patients had evidence of angiographic restenosis. The MLD (mm) and percent stenosis were 0.77 +/- 0.27/72.5 +/- 8.6 pre angioplasty, 2.08 +/- 0.4/25.7 +/- 9.8 post angioplasty and radiation and 2.05 +/- 0.59/25.7 +/- 19.8 at follow-up respectively. CONCLUSION: Beta radiation can be feasibly and safely delivered post coronary angioplasty with a very encouraging reduction of restenosis.  相似文献   

3.
Technical advancement and new anti-thrombotic regimens have recently shown so much improvement in the results of coronary stenting that the conventional contra-indication for stenting in small coronary arteries (<3 mm) needs to be revised. We undertook a prospective pilot study of elective Palmaz-Schatz stenting in de novo lesions located in coronary arteries of less than 3 mm diameter. Fifty consecutive patients (63 +/- 9 years) with stable (n = 38) and unstable angina (n = 12) were included. Philips-DCI quantitative coronary analysis was used to measure reference diameter, minimal lumen diameter and percent diameter stenosis before PTCA, after stenting and at 6-month angiographic follow-up study. All measurements were performed after intracoronary injection of nitroglycerin (300 microg). All patients received ticlopidine (250 mg/day) and aspirin (100 mg/day). The mean lesion length was 9 +/- 3 mm. The balloon size used for stent delivery was 2.75 mm in 30 patients and 2.5 mm in 20 patients and the mean balloon inflation pressure used for stent deployment was 12 +/- 2 atm. All stents were deployed successfully. In-hospital complications occurred in two patients, diagonal branch occlusion at day 2 requiring emergency PTCA in one and a hematoma at the femoral puncture site requiring surgery in the other. Major adverse cardiac event (MACE) rate remained 2% (nonfatal infarct in one). Follow-up angiography (n = 46, 92%) at 6 +/- 3 months showed a 30% restenosis rate. Target vessel revascularization (TVR) rate was 13%. We conclude that elective stenting in small coronary arteries is feasible and involves an acceptable risk of restenosis.  相似文献   

4.
Optimized stent expansion by high-pressure inflations of oversized balloons has initially been derived from experience obtained with the Palmaz-Schatz stent, whereas there is little experience with this strategy in the Wallstent. By using this approach with quantitative coronary angiographic guidance, 20 Wallstents and 20 Palmaz-Schatz stents were implanted in 34 patients and consecutively examined by conventional two-dimensional (2D) intracoronary ultrasound (ICUS) and three-dimensional (3D) ICUS on the basis of the application of a pattern recognition algorithm. Ultrasound criteria of adequate stent expansion were defined as a complete apposition of the stent to the vessel wall, a stent symmetry index (SSI = minimum/maximum lumen diameter) > or = O.7, and a stent-reference lumen area ratio (SRR = Minimum intrastent lumen area/Average of proximal and distal reference lumen area) > or = O.8. In all cases a smooth angiographic lumen and a negative diameter stenosis, on the basis of a distal reference, was achieved. For the Wallstents ICUS showed a higher SSI (2D, 0.95 +/- 0.04 vs 0.85 +/- 0.09; p < 0.001; 3D, 0.90 +/- 0.09 vs 0.82 +/- 0.11, p < 0.05) and a lower SRR (2D, 0.66 +/- 0.12 vs 0.81 +/- 0.13, p < 0.005; 3D, 0.63 +/- 0.14 vs 0.74 +/- 0.15, p < 0.05) than for the Palmaz-Schatz stents. Ninety percent of failure in meeting these criteria resulted from a low SRR. The incidence of incomplete stent apposition (one in both stents) or SSI <0.7 was low and generally associated with an SRR <0.8. The Wallstents met the ICUS criteria less often (2D, 2(1O%) vs 10(50%), p < 0.01; 3D, 3(15%) vs 9(45%), p < 0.05), were significantly longer (35.1 +/- 7.7 mm and 14.3 +/- 3.3 mm, p < 0.0001), and generally demonstrated a larger vessel tapering, measured as proximal minus distal ICUS reference lumen area (1.33 +/- 2.91 mm2 vs 0.44 +/- 1.97 mm(2), not significant). Wallstents meeting the ICUS criteria, however, showed less vessel tapering (0.18 +/- 1.64 mm(2)). Thus optimized stent expansion was followed by excellent angiographic results for both Palmaz-Schatz and Wallstent. Although angiographic results and visual assessment of the ICUS examination suggested a good outcome, few Wallstents met the ICUS criteria in contrast to the Palmaz-Schatz stents. The low value of the SRR in the Wallstents is likely to be caused by vessel tapering, suggesting that this criterion may be unsuitable in assessing the adequacy of the expansion of relatively long stents such as the Wallstent.  相似文献   

5.
OBJECTIVES: The purpose of this prospective study was to evaluate the immediate results and the 6-month angiographic recurrent restenosis rate after balloon angioplasty for in-stent restenosis. BACKGROUND: Despite excellent immediate and mid-term results, 20% to 30% of patients with coronary stent implantation will present an angiographic restenosis and may require additional treatment. The optimal treatment for in-stent restenosis is still unclear. METHODS: Quantitative coronary angiography (QCA) analyses were performed before and after stent implantation, before and after balloon angioplasty for in-stent restenosis and on a 6-month systematic coronary angiogram to assess the recurrent angiographic restenosis rate. RESULTS: Balloon angioplasty was performed in 52 patients presenting in-stent restenosis. In-stent restenosis was either diffuse (> or =10 mm) inside the stent (71%) or focal (29%). Mean stent length was 16+/-7 mm. Balloon diameter of 2.98+/-0.37 mm and maximal inflation pressure of 10+/-3 atm were used for balloon angioplasty. Angiographic success rate was 100% without any complication. Acute gain was lower after balloon angioplasty for in-stent restenosis than after stent implantation: 1.19+/-0.60 mm vs. 1.75+/-0.68 mm (p=0.0002). At 6-month follow-up, 60% of patients were asymptomatic and no patient died. Eighteen patients (35%) had repeat target vessel revascularization. Angiographic restenosis rate was 54%. Recurrent restenosis rate was higher when in-stent restenosis was diffuse: 63% vs. 31% when focal, p=0.046. CONCLUSIONS: Although balloon angioplasty for in-stent restenosis can be safely and successfully performed, it leads to less immediate stenosis improvement than at time of stent implantation and carries a high recurrent angiographic restenosis rate at 6 months, in particular in diffuse in-stent restenosis lesions.  相似文献   

6.
BACKGROUND: Restenosis has been perceived as the tail end of a normal distribution of the response of the vessel to the intervention. However, recent studies have described a bimodal distribution for de novo lesions after percutaneous transluminal coronary angioplasty. This finding suggests that some lesions may be more susceptible for restenosis. Whether this holds true for a wider spectrum of lesions undergoing stent placement is not yet known. The present study analyzes the frequency distribution of angiographic indexes of restenosis 6 months after coronary stent implantation. METHODS AND RESULTS: Quantitative angiographic evaluation was performed in 1084 lesions of 1084 patients before, immediately after, and 6 months after successful Palmaz-Schatz stent placement; this represented 80.4% of patients eligible for follow-up angiography. Principal end points of the analysis were angiographic indexes of restenosis at 6 months. Twenty-two lesions that became totally occluded at follow-up were excluded from most parts of the analysis. Diameter stenosis, minimal luminal diameter (MLD), and lumen loss at 6 months did not follow a normal pattern; the bimodal pattern was demonstrated through deconvolution that yielded two separate normal components delineating two lesion populations, which developed distinctively different degrees of lumen renarrowing. The first and larger subgroup of lesions, which was less prone to restenosis, was centered around a mean value of 27% for diameter stenosis and 2.19 mm for MLD, whereas the second subgroup, with a greater tendency for restenosis, was situated around a mean value of 68% for diameter stenosis and 0.76 mm for MLD. The intersection point between the two theoretical normal distribution components was 53.5% for diameter stenosis and 1.09 mm for MLD at follow-up. CONCLUSIONS: Frequency-distribution curves of angiographic indexes of restenosis after coronary stent placement have a bimodal pattern, suggesting the existence of two distinct populations with different propensity to restenosis. These findings may encourage future efforts for the timely identification of the subset with a higher risk as the target of specific antirestenotic strategies.  相似文献   

7.
OBJECTIVES: We aimed to investigate the impact of intravascular ultrasound (IVUS)-guided stent implantation on the 6-month restenosis rate, which has not yet been fully established in randomized trials. BACKGROUND: The 6-month angiographic restenosis rate was compared in patients with symptomatic ischemic heart disease who were randomly allocated to angioplasty and stent deployment, with versus without IVUS guidance. METHODS: After successful stent implantation, patients were randomized into two groups: Group A had no further dilation, and Group B had additional balloon dilation until achievement of IVUS criterion for stent expansion. The study group consisted of 164 patients, assuming a 50% reduction of the restenosis rate in Group B (15% vs. 30%) (alpha = 10%, beta = 20%). RESULTS: We enrolled 155 patients. Overdilation was carried out in 31 (39%) of 79 Group B patients, with the IVUS criterion being achieved in 63 (80%) of 79. No significant difference was observed in the minimal luminal diameter (MLD), but the stent lumen cross-sectional area (CSA) was significantly larger in Group B (mean +/- SD) (7.16 +/- 2.48 vs. 7.95 +/- 2.21 mm2, p = 0.04). At 6 months, there was no significant difference in the restenosis rate, (28.8% [21 of 73] in Group A vs. 22.5% [16 of 71] in Group B, p = 0.25), but according to the observed difference in the restenosis rate, the power of the study was only 40%. The difference in MLD was also nonsignificant (1.60 +/- 0.65 mm in Group A vs. 1.70 +/- 0.64 mm in Group B, p = 0.20), whereas the lumen CSA was 20% larger in the IVUS-guided group (4.47 +/- 2.59 vs. 5.36 +/- 2.81 mm2, p = 0.03). Lumen CSA was the only predictor of restenosis by multivariate logistic regression analysis. CONCLUSIONS: A nonsignificant 6.3% absolute reduction in the restenosis rate and a nonsignificant difference in MLD were observed in this study. Nonetheless, we still cannot rule out a beneficial effect of IVUS guidance, although this may have gone undetected owing to a lack of statistical power. A significant increase was observed in immediate and 6-month lumen size, as detected by IVUS, indicating that ultrasound guidance in stent deployment may be beneficial.  相似文献   

8.
BACKGROUND: Diabetes is a major risk factor for restenosis after coronary balloon angioplasty. Recent studies have shown that coronary stenting significantly reduces restenosis compared with balloon angioplasty alone. However, limited information is available on the effect of coronary stenting in diabetic patients. METHODS AND RESULTS: We designed this study to analyze the effect of diabetes on restenosis in patients treated with either balloon angioplasty or coronary stenting who were enrolled in a 6-month angiographic follow-up program. Three hundred consecutive patients, 19% of whom were diabetics, who underwent coronary stent implantation during a single-vessel procedure on native coronary vessels and who had 6-month angiographic follow-up constituted the study group (stent group). Three hundred consecutive patients who underwent 6-month angiographic follow-up after single-vessel conventional balloon angioplasty served as control patients (balloon group). Preprocedural, postprocedural, and follow-up angiograms were analyzed with quantitative angiography. In the balloon group, the restenosis rate was almost twofold higher in diabetic than in nondiabetic patients (63% versus 36%; P=.0002) owing to both a greater late loss (0.79+/-0.70 versus 0.41+/-0.61 mm, respectively; P<.0001) and a higher rate of late vessel occlusion (14% versus 3%, respectively; P<.001). In the stent group, restenosis rates were similar in diabetics and nondiabetics (25% versus 27%, respectively). Furthermore, in the stent group, late loss (0.77+/-0.65 versus 0.79+/-0.57 mm, respectively) and the rate of late vessel occlusion (2% versus 1%, respectively) did not differ significantly between diabetic and nondiabetic patients. CONCLUSIONS: Although diabetics have increased rates of restenosis and late vessel occlusion after simple balloon angioplasty, they have the same improved outcome with coronary stenting that has been documented in nondiabetic patients.  相似文献   

9.
The EBI (BARD-XT, C.R. Bard, Murray Hill, NJ) stent is a new radiopaque balloon expandable coronary stent with high resistance to external radial forces. It does not shorten significantly with expansion and allows stent implantation in bifurcation lesions. A total of 28 EBI stents were implanted in 23 lesions in 21 patients. Indications for stent implantation were acute closure in 1, threatened closure in 15, and electively in 7 lesions. In 2 cases, the lesion involved a bifurcation where a stent was implanted in both vessels. All patients received aspirin and ticlopidine. No anticoagulant therapy was given. The stenting procedure was successful in 22 of 23 lesions. No complications occurred with the exception of 1 patient with a thrombotic reocclusion within 1 hr after stent implantation and 1 patient with a temporary occlusion of a side branch. The mean minimal luminal diameter (MLD) increased from 0.74+/-0.46 mm before balloon dilatation to 1.27+/-0.62 mm before stent implantation and 2.32+/-0.57 mm after stent implantation. Percent stenosis decreased from 71+/-19% before angioplasty to 46+/-25% after angioplasty to 5+/-8% after stent implantation. MLD at the time of follow-up angiography after 4 months was 1.98+/-0.77 mm and percent stenosis was 26+/-21%. Restenosis of more than 50% occurred in 2 lesions. In these lesions, a second percutaneous transluminal coronary angioplasty was performed. Advantages of this stent are its flexibility together with an acceptable radial strength as well as enabling radiopacity without obscuring the arterial lumen. Stenting of bifurcation lesions is possible.  相似文献   

10.
The Bard Atherectomy Catheter is a new rotational atherectomy device that consists of a flexible, hollow, thin-walled cutting catheter that, while rotated at 1,500 revolutions per minute, is advanced across the lesion over a special spiral guidewire system. We report the initial clinical experience with this device in 20 peripheral lesions in ten patients. The majority of patients were treated for limb salvage. All lesions were successfully intervened on by atherectomy followed by adjunctive balloon angioplasty. A reduction to less than 50% stenosis was achieved in 13 of the 20 lesions (65%) after atherectomy but in all 20 lesions (100%) after adjunctive angioplasty for all lesions and stenting for dissections in two. Baseline minimal lesion lumen diameter was 0.8 +/- 0.7 mm with a reference vessel diameter of 4.2 +/- 1.7 mm (75 +/- 21% stenosis). The lumen improved to 2.0 +/- 0.8 mm (45 +/- 19% stenosis) (P < 0.001) following atherectomy and to 3.9 +/- 1.9 mm (13 +/- 16% stenosis) (P < 0.001) after adjunctive angioplasty. The average weight of removed atheroma was 45 +/- 58 mg. All ten patients had initial improvement in symptoms. At 6 months follow-up there was persistent improvement in eight patients and two subjects had undergone amputations. Our early clinical experience with this low profile, flexible atherectomy device, that enables extraction of a large amount of atheroma, suggests that it will become a valuable addition to current atherectomy technologies in small- and medium-sized vessels. The value of this device in coronary vessels is under investigation.  相似文献   

11.
With the increasing clinical application of new devices for percutaneous coronary revascularization, maximization of the acute angiographic result has become widely recognized as a key factor in maintained clinical and angiographic success. What is unclear, however, is whether the specific mode of action of different devices might exert an additional independent effect on late luminal renarrowing. The purpose of this study was to investigate such a difference in the degree of provocation of luminal renarrowing (or 'restenosis propensity') by different devices, among 3660 patients, who had 4342 lesions successfully treated by balloon angioplasty (n = 3797), directional coronary atherectomy (n = 200), Palmaz-Schatz stent implantation (n = 229) or excimer laser coronary angioplasty (n = 116) and who also underwent quantitative angiographic analysis pre- and post-intervention and at 6-month follow-up. To allow valid comparisons between the groups, because of significant differences in coronary vessel size (balloon angioplasty = 2.62 +/- 0.55 mm, directional coronary atherectomy = 3.28 +/- 0.62 mm, excimer laser coronary angioplasty = 2.51 +/- 0.47 mm, Palmaz-Schatz = 3.01 +/- 0.44 mm; P < 0.0001), the comparative measurements of interest selected were the 'relative loss' in luminal diameter (RLoss = loss/vessel size) to denote the restenosis process, and the 'relative lumen at follow-up' (RLfup = minimal luminal diameter at follow up/vessel size) to represent the angiographic outcome. For consistency, lesion severity pre-intervention was represented by the 'relative lumen pre' (RLpre = minimal luminal diameter pre/vessel size) and the luminal increase at intervention was measured as 'relative gain' (relative gain = gain/ vessel size). Differences in restenosis propensity between devices was evaluated by univariate and multivariate analysis. Multivariate models were constructed to determine relative loss and relative lumen at follow-up, taking account of relative lumen pre-intervention, lesion location, relative gain, vessel size and the device used. In addition, model-estimated relative loss and relative lumen at follow-up at given relative lumen pre-intervention relative gain and vessel size, were compared among the four groups. Significant differences were detected among the groups both with respect to these estimates, as well as in the degree of influence of progressively increasing relative gain, on the extent of renarrowing (relative loss) and angiographic outcome (relative lumen at follow-up), particularly at higher levels of luminal increase (relative gain). Specifically, lesions treated by balloon angioplasty or Palmaz-Schatz stent implantation (the predominantly 'dilating' interventions) were associated with more favourable angiographic profiles than directional atherectomy or excimer laser (the mainly 'debulking' interventions). Significant effects of lesion severity and location, as well as the well known influence of luminal increase on both luminal renarrowing and late angiographic outcome were also noted. These findings indicate that propensity to restenosis after apparently successful intervention is influenced not only by the degree of luminal enlargement achieved at intervention, but by the device used to achieve it. In view of the clinical implications of such findings, further evaluation in larger randomized patient populations is warranted.  相似文献   

12.
CJ White 《Canadian Metallurgical Quarterly》1997,41(1):1-3; discussion 4
Wiktor-GX coil stents and Palmaz-Schatz 154A tubular stents were implanted in a consecutive series of 40 patients and 45 arteries undergoing successful primary stent placement in de novo lesions treated with single stents in order to compare the acute recoil of a coil stent to a tubular stent in native coronary arteries. Acute stent recoil was determined by measuring the difference between the maximum inflated diameter of the stent deployment balloon and the minimum lumen diameter after stent deployment. There was no difference between the two groups for reference vessel diameter, nominal balloon diameter, maximum inflated balloon diameter, maximum inflation pressure, or poststent vessel minimum lumen diameter. Acute recoil averaged 0.15 +/- 0.2 mm for the Wiktor-GX and 0.13 +/- 0.1 for the Palmaz-Schatz (P = 0.58). In this series of patients, there was no significant difference between the acute recoil of the coil stent compared to the tubular stent.  相似文献   

13.
Patients with recurrent angina after coronary artery bypass graft surgery pose a problem. Stent implantation has been advocated in an effort to avoid repeat operation and to address the limitations of balloon angioplasty. Aim of the present study was to determine the in-hospital and long-term results of stent deployment in focal, de novo lesions of vein grafts. Thirty-five focal, de novo lesions of vein grafts in 31 patients were treated with stent deployment. Twenty-four patients (77%) had three vessels, 6 (20%) two vessels and 1 (3%) single vessel disease. Saphenous vein grafts aged 9.7 +/- 4.2 years (range 1-19 years). Twenty-two lesions (63%) were located within the body of the saphenous graft, 8 (23%) at the graft/coronary artery anastomosis and 5 (14%) at the aorta/graft anastomosis. The indications for stent deployment included: suboptimal result from balloon angioplasty (defined as > or = 50% post-angioplasty residual stenosis) in 29/35 lesions (83%); post-angioplasty coronary dissection with threatening occlusion in 4/35 (11%); abrupt closure in 2/35 (6%). Patients were screened for death, myocardial infarction, bypass surgery and repeat angioplasty during in-hospital stay and after a follow-up of 12 +/- 8 months. Even-free survival curve was constructed by the Kaplan-Meier method. Stent deployment was successful in all patients. One stent was deployed in 24/35 lesions (69%), half Palmaz-Schatz stent in 6/35 (17%) and 2 or more stents in 5/35 (14%). The balloon/vessel ratio resulted of 1.0 +/- 0.1 Minimal lumen diameter increased from 0.8 +/- 0.4 to 3.8 +/- 0.6 mm, with a mean gain of 1.8 +/- 0.6 mm (range 1.8-4.0 mm). During the in-hospital period 1 patient (3.2%) died and 1 (3.2%) had a non Q wave myocardial infarction. Therefore, the clinical success rate, was 94%. During the follow-up period, 2 patients died (6.9%), 2 (6.9%) developed a non Q wave myocardial infarction, 1 (3.4%) underwent bypass surgery and 3 (10.3%) underwent repeat angioplasty. The estimated 2-year event-free survival rate (free from myocardial infarction, repeat surgery and repeat angioplasty) was 62%. In conclusion, Palmaz-Schatz stent deployment in focal, de novo vein grafts presents a high rate of procedural success, a low rate of acute complications and good long-term results.  相似文献   

14.
The standard coronary stent implantation technique requires routine predilatation of the target lesion with a balloon catheter. In this study, we prospectively studied the feasibility and efficiency of elective coronary stent implantation without predilatation. In 94 patients who presented with various ischemic syndromes, direct implantation of 100 balloon expandable ACS MultiLink stents (7 over-the-wire, 93 rapid exchange) was attempted in 100 coronary lesions selected to have favorable characteristics. The stent crossed the lesion without predilatation in 97 cases (97%) and was successfully deployed in 93 (95.8%). In 4 patients, adjunctive high-pressure postdilatation was necessary to achieve optimal stent expansion. Reference vessel diameter was 3.12+/-0.77 mm and lesion length 8.8+/-2.7 mm. Minimal luminal diameter increased from 0.95+/-0.38 mm to 2.98+/-0.28 mm and diameter stenosis decreased from 71+/-11% to 8+/-11% after stenting. One occlusive dissection was treated by a second stent. There were no major in-hospital complications. At 1 month follow-up, 1 subacute thrombotic occlusion occurred. These results indicate that in a carefully selected coronary lesion subset, elective stent implantation without predilatation can be safely and effectively performed. The long-term results of this approach and possible advantages over the conventional implantation techniques remain unclear and need to be evaluated in further clinical studies.  相似文献   

15.
OBJECTIVE: This study sought to compare two strategies of revascularization in patients obtaining a good immediate angiographic result after percutaneous transluminal coronary angioplasty (PTCA): elective stenting versus optimal PTCA. A good immediate angiographic result with provisional stenting was considered to occur only if early loss in minimal luminal diameter (MLD) was documented at 30 min post-PTCA angiography. BACKGROUND: Coronary stenting reduces restenosis in lesions exhibiting early deterioration (>0.3 mm) in MLD within the first 24 hours (early loss) after successful PTCA. Lesions with no early loss after PTCA have a low restenosis rate. METHODS: To compare angiographic restenosis and target vessel revascularization (TVR) of lesions treated with coronary stenting versus those treated with optimal PTCA, 116 patients were randomized to stent (n=57) or to optimal PTCA (n=59). After randomization in the PTCA group, 13.5% of the patients crossed over to stent due to early loss (provisional stenting). RESULTS: Baseline demographic and angiographic characteristics were similar in both groups of patients. At 7.6 months, 96.6% of the entire population had a follow-up angiographic study: 98.2% in the stent and 94.9% in the PTCA group. Immediate and follow-up angiographic data showed that acute gain was significantly higher in the stent than in the PTCA group (1.95 vs. 1.5 mm; p < 0.03). However, late loss was significantly higher in the stent than the PTCA group (0.63+/-0.59 vs. 0.26+/-0.44, respectively; p=0.01). Hence, net gain with both techniques was similar (1.32< or =0.3 vs. 1.24+/-0.29 mm for the stent and the PTCA groups, respectively; p=NS). Angiographic restenosis rate at follow-up (19.2% in stent vs. 16.4% in PTCA; p=NS) and TVR (17.5% in stent vs. 13.5% in PTCA; p=NS) were similar. Furthermore, event-free survival was 80.8% in the stent versus 83.1% in the PTCA group (p=NS). Overall costs (hospital and follow-up) were US $591,740 in the stent versus US $398,480 in the PTCA group (p < 0.02). CONCLUSIONS: The strategy of PTCA with delay angiogram and provisional stent if early loss occurs had similar restenosis rate and TVR, but lower cost than primary stenting after PTCA.  相似文献   

16.
Management of in-stent restenosis has become a significant challenge in interventional cardiology. The results of balloon angioplasty have been disappointing due to the high recurrence of restenosis at follow-up. Debulking of the restenotic tissue within the stents using directional coronary atherectomy (DCA) may offer a therapeutic advantage. We report the immediate clinical and angiographic outcomes and long-term clinical follow-up results of 45 patients (46 lesions), mean age 63+/-12 years, 73% men, with a mean reference diameter of 2.9+/-0.6 mm, treated with DCA for symptomatic Palmaz-Schatz in-stent restenosis. DCA was performed successfully in all 46 lesions and resulted in a postprocedural minimal luminal diameter of 2.7+/-0.7 mm and a residual diameter stenosis of 17+/-10%. There were no in-hospital deaths, Q-wave myocardial infarctions, or emergency coronary artery bypass surgeries. Four patients (9%) suffered a non-Q-wave myocardial infarction. Target lesion revascularization was 28.3% at a mean follow-up of 10+/-4.6 months. Kaplan-Meier event-free survival (freedom from death, myocardial infarction, and repeat target lesion revascularization) was 71.2% and 64.7% at 6 and 12 months after DCA, respectively. Thus, DCA is safe and efficacious for the treatment of Palmaz-Schatz in-stent restenosis. It results in a large postprocedural minimal luminal diameter and a low rate of both target lesion revascularization and combined major clinical events at follow-up.  相似文献   

17.
OBJECTIVES: A study was set up to validate the safety and feasibility of intravascular ultrasound-guided stenting without subsequent anticoagulation, and its impact on the 6 months restenosis rate. METHODS: The study was designed to be multicentred, prospective, and observational. RESULTS: One hundred and sixty-one patients with stable angina and a de novo coronary artery lesion were enrolled. In four patients, the implantation of a Palmaz-Schatz (with spiral bridge) stent had failed. One of these four patients died 3 days following bypass surgery. In two other patients, intravascular ultrasound assessment was not performed. One hundred and twenty-five of the remaining 155 patients (81%) were treated with aspirin (100 mg x day(-1)), because all three criteria for optimized stent expansion were met. Twenty-two of the remaining 38 patients (25%), in whom at least one criterion was not met were treated with aspirin and acenocoumarol (3 months, INR 2.5-3.5), while 16 patients only received aspirin. Stent thrombosis was documented in two patients (1.3%) for which repeat angioplasty was performed. During the hospital stay, there were no deaths or Q-wave myocardial infarctions. Five patients (3.2%) sustained a non-Q-wave myocardial infarction. During the follow-up period (198+/-38 days, complete for all patients, except one), one patient (0.6%) sustained a Q-wave myocardial infarction, one (0.6%) underwent bypass surgery, and repeat angioplasty was performed in nine patients (5.7%). In two of the nine patients, repeat angioplasty involved another lesion. Therefore, the target lesion revascularization rate during follow-up was 4.5% (seven patients). At quantitative coronary angiography, the minimal lumen diameter (mean+/-SD) increased from 1.12+/-0.34 mm before to 2.89+/-0.35 mm after stenting. Repeat angiography at 6 months was performed in 144 patients (92%). The minimal lumen diameter at follow-up was 2.12+/-0.67 mm. Restenosis (diameter stenosis of 50% or more) was documented in 12 patients or 8.3%. When the two patients with documented stent thrombosis are included, the restenosis rate amounts to 97%. CONCLUSIONS: These data confirm that, in selected patients, stents can safely be implanted without the use of systemic anticoagulation, provided optimal stent expansion is achieved. The exact role of intravascular ultrasound in the achievement of these results needs to be established by appropriately designed studies. In the meantime, intravascular ultrasound coupled with the Palmaz-Schatz stent incorporating a spiral bridge, may have contributed considerably to the immediate angiographic outcome, which in turn may explain the favourable clinical and angiographic outcome at 6 months.  相似文献   

18.
OBJECTIVES: The purpose of this study was to compare the immediate angiographic and long-term results of debulking versus balloon angioplasty for treatment of true bifurcation lesions. BACKGROUND: Previous studies have shown true bifurcation lesions to be a high risk morphological subset for percutaneous transluminal coronary angioplasty (PTCA). Although atherectomy devices have been used to treat bifurcation lesions, no studies have compared the outcomes of these alternative treatment modalities. METHODS: Between January 1992 and May 1997, we treated 70 consecutive patients with true bifurcation lesions (defined as a greater than 50% stenosis in both the parent vessel and contiguous side branch) with conventional PTCA (n = 30) or debulking (with rotational or directional atherectomy) plus adjunctive PTCA (n = 40). Paired angiograms were analyzed by quantitative angiography, and clinical follow-up was obtained in all patients. RESULTS: Acute procedural success was 73% in the PTCA group and 97% in the debulking group (p = 0.01). Major in-hospital complications occurred in two patients in the PTCA group and one in the debulking group. Treatment with atherectomy plus PTCA resulted in lower postprocedure residual stenoses than PTCA alone (16+/-15% vs. 33+/-17% in the parent vessel, and 6+/-15% vs. 39+/-22% in the side branch; p < 0.001 for both comparisons). At 1 year follow-up, the incidence of target vessel revascularization (TVR) was 53% in the PTCA group as compared with 28% in the debulking group (p = 0.05). Independent predictors of the need for repeat TVR were side branch diameter >2.3 mm, longer lesion lengths, and treatment with PTCA alone. CONCLUSIONS: For the treatment of true bifurcation lesions, atherectomy with adjunctive PTCA is safe, improves acute angiographic results, and decreases target vessel revascularization compared to PTCA alone. The benefits of debulking for bifurcation lesions were especially seen in lesions involving large side branches.  相似文献   

19.
OBJECTIVE: Our purpose was to determine echocardiographic trends after initial diagnosis of peripartum cardiomyopathy. STUDY DESIGN: Nine women diagnosed with peripartum cardiomyopathy were prospectively recruited for a longitudinal echocardiographic study. Severe myocardial dysfunction was defined as left ventricular end-diastolic dimension > or = 60 mm + fractional shortening < or = 21%, and mild dysfunction was defined as left ventricular end-diastolic dimension < 60 mm + fractional shortening 22% to 24%. Unpaired t tests were used to compare sample means and Fisher's exact test used to compare discrete variables. RESULTS: All women were seen initially for pulmonary edema. Echocardiography showed decreased systolic function in all women. The mean age at diagnosis was 33.0 +/- 6.9 years. All but one woman had a diagnosis of either chronic hypertension (n = 6) or preeclampsia (n = 2). Four women were first seen ante partum and five post partum (range 1 day to 2 months). Repeat echocardiography was performed in all nine women (median 8 months, range 6 weeks to 5 years). There was no correlation between antepartum or postpartum presentation and cardiovascular status on follow-up (p = 0.3). Values for initial left ventricular end-diastolic dimension, severe versus mild dysfunction (68.3 +/- 7.2 mm vs 55.0 +/- 4.2 mm, p = 0.046), follow-up left ventricular end-diastolic dimension, severe versus mild (68.7 +/- 4.1 mm vs 52.0 +/- 5.7 mm, p = 0.002), and follow-up fractional shortening, severe versus mild (14.6% +/- 5.0% vs 28.5% +/- 9.2%, p = 0.02) are significant. Six of the seven women with severe dysfunction had stable disease in follow-up and one is awaiting heart transplant. One of the two women with mild dysfunction had disease resolution and one had stable disease. CONCLUSION: Patients with severe myocardial dysfunction due to peripartum cardiomyopathy are unlikely to regain normal cardiac function on follow-up.  相似文献   

20.
BACKGROUND: The multicentre, randomised Benestent-II study investigated a strategy of implantation of a heparin-coated Palmar-Schatz stent plus antiplatelet drugs compared with the use of balloon angioplasty in selected patients with stable or stabilised unstable angina, with one or more de-novo lesions, less than 18 mm long, in vessels of diameter 3 mm or more. METHODS: 827 patients were randomly assigned stent implantation (414 patients) or standard balloon angioplasty (413 patients). The primary clinical endpoint was event-free survival at 6 months, including death, myocardial infarction, and the need for revascularisation. The secondary endpoints were the restenosis rate at 6 months and the cost-effectiveness at 12 months. There was also one-to-one subrandomisation to either clinical and angiographic follow-up or clinical follow-up alone. Analyses were by intention to treat. FINDINGS: Four patients (one stent group, three angioplasty group) were excluded from analysis since no lesion was found. At 6 months, a primary clinical endpoint had occurred in 53 (12.8%) of 413 patients in the stent group and 79 (19.3%) of 410 in the angioplasty group (p=0.013). This significant difference in clinical outcome was maintained at 12 months. In the subgroup assigned angiographic follow-up, the mean minimum lumen diameter was greater in the stent group than in the balloon-angioplasty group, (1.89 [SD 0.65] vs 1.66 [0.57] mm, p=0.0002), which corresponds to restenosis rates (diameter stenosis > or =50%) of 16% and 31% (p=0.0008). In the group assigned clinical follow-up alone, event-free survival rate at 12 months was higher in the stent group than the balloon-angioplasty group (0.89 vs 0.79, p=0.004) at a cost of an additional 2085 Dutch guilders (US$1020) per patient. INTERPRETATION: Over 12-month follow-up, a strategy of elective stenting with heparin-coated stents is more effective but also more costly than balloon angioplasty.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司    京ICP备09084417号-23

京公网安备 11010802026262号