1.
The geometrical surfaces of soil-burrowing animals were imitated and modeled on a cone component, the measuring tip part of a soil cone penetrometer. These biomimetic surfaces are concave dimples, convex domes and two wavy forms. The conventional cone surface and the biomimetic cone surfaces were analyzed in ANSYS 11.0 program to estimate cone equivalent stress and soil equivalent stress. Results show that biomimetic surfaces with the geometrical structures have lower cone equivalent stresses and soil equivalent stresses than that with conventional (smooth) surface. The least maximum cone equivalent stress and least maximum soil equivalent stress were recorded for biomimetic surfaces with concave dimples and wavy form-2 respectively. The two-body abrasive wear of biomimetic cone surfaces and conventional (smooth) cone surface were run on a rotary disk type of abrasive wear testing machine. The biomimetic cone surfaces were found to have lower abrasive wear than the conventional surface. It was found that and biomimetic cone surface with concave dimples has the lowest abrasive wear among the all tested surfaces.  相似文献   

2.
Ultra High Molecular Weight Polyethylene(UHMWPE)has been widely used as a bearing material for artificial joint replacementover forty years.It is usually crosslinked by gamma rays irradiation before its implantation into human body.In thisstudy,UHMWPE and UHMWPE/nano-hydroxyapatite(n-HA)composite were prepared by vacuum hot-pressing method.Theprepared materials were irradiated by gamma rays in vacuum and molten heat treated in vacuum just after irradiation.The effectof filling n-HA with gamma irradiation on tribological properties of UHMWPE was investigated by using friction and wearexperimental machine(model MM-200)under deionized water lubrication.Micro-morphology of worn surface was observedby metallographic microscope.Contact angle and hardness of the materials were also measured.The results show that contactangle and hardness are changed by filling n-HA and gamma irradiation.Friction coefficient and wear rate under deionized waterlubrication are reduced by filling n-HA.While friction coefficient is increased and wear rate is reduced significantly by gammairradiation.The worn surface of unfilled material is mainly characterized as adhesive wear and abrasive wear,and that of n-HAfilled material is mainly characterized as abrasive wear.After gamma irradiation,the degrees of adhesive and abrasive wear forunfilled material and abrasive wear of n-HA filled material are significantly reduced.Unfilled and filled materials after irradiationare mainly shown as slight fatigue wear.The results indicate that UHMWPE and UHMWPE/n-HA irradiated at the doseof 150 kGy can be used as bearing materials in artificial joints for its excellent wear resistance compared to original UHMWPE.  相似文献   

3.
Computational simulations of wear of orthopaedic total joint replacement implants have proven to valuably complement laboratory physical simulators, for pre-clinical estimation of abrasive/adhesive wear propensity. This class of numerical formulations has primarily involved implementation of the Archard/Lancaster relationship, with local wear computed as the product of (finite element) contact stress, sliding speed, and a bearing-couple-dependent wear factor. The present study introduces an augmentation, whereby the influence of interface cross-shearing motion transverse to the prevailing molecular orientation of the polyethylene articular surface is taken into account in assigning the instantaneous local wear factor. The formulation augment is implemented within a widely utilized commercial finite element software environment (ABAQUS). Using a contemporary metal-on-polyethylene total disc replacement (ProDisc-L) as an illustrative implant, physically validated computational results are presented to document the role of cross-shearing effects in alternative laboratory consensus testing protocols. Going forward, this formulation permits systematically accounting for cross-shear effects in parametric computational wear studies of metal-on-polyethylene joint replacements, heretofore a substantial limitation of such analyses.  相似文献   

4.
Recently, highly crosslinked UHMWPE components have been promoted for their high abrasive wear resistance over conventional UHMWPE (PE) in total joint replacement (TJR) prostheses to minimize osteolysis and consequent implant loosening. This study was aimed at investigating the role of friction gradients induced by localized coefficients of friction at both crystalline and amorphous nanoregions in PE, and crystalline and crosslinked nanoregions in crosslinked UHMWPE (XPE), in submicron wear debris generation. An abrasive wear study performed on both XPE and PE using atomic force microscopy (AFM) illustrated that the onset of plastic deformation for XPE occurred at a normal load that was approximately 3 times higher when compared to PE. Coefficients of friction (mu d) of 0.2, 0.35, and 0.61, experimentally derived using AFM, were used as representative mu d for crystalline, amorphous, and crosslinked nanoregions, respectively, in a numerical Hertzian model. An increase in mu (0.2 +/- 0.02, 0.35 +/- 0.01 and 0.6 +/- 0.04) was observed with a decrease in crystallinity and storage modulus at 22 degrees C. Using the Hertzian contact model, it was observed that variability in friction between nanoregions contributed to higher magnitude stresses for XPE (0.2 to 0.61; maximum sigma eff = 2.8) compared to PE (0.2 to 0.35; maximum sigma eff = 1.1) over a negligible thickness of the interfacial zone (IZ) between nanoregions. The experimentally observed increase in abrasive wear resistance of XPE could be attributed to an increase in the thickness of the interfacial zone between nanoregions with mu changing gradually from crystalline to crosslinked nanoregions, a situation that may not be observed with PE. This would cause a decrease in the friction gradient and resulting stresses thereby agreeing with the observed experimental higher abrasive wear resistance for XPE. However, in both PE and XPE, the presence of stress concentrations over a period of time could lead to irreversible damage of the material eventually generating submicron wear debris. Hence, semicrystalline, inhomogenous UHMWPE with several nanoregions (amorphous and crystalline) would be at a disadvantage for bearing application in terms of abrasive wear resistance compared to UHMWPE with relatively lower number of nanoregions and crosslinked nanoregions.  相似文献   

5.
The Pangolin, a soil-burrowing animal, is covered with scales. These scales are often abraded by soil and rock and their surface is corrugated. The abrasive wear of the surface of the scales was examined. The scales were taken from a pangolin that had died of natural causes. The tests were run on a rotary disc abrasive wear tester. The abrasive material was quartz sand (96.5 wt.%) and bentonite (3.5 wt.%). The morphology of the abraded surfaces and the abrasion were examined by stereoscopic microscopy and scanning electron microscopy. The concepts are proposed of "Guiding-Effect" and "Rolling-Effect" on the textured surfaces under free abrasive wear conditions and the critical dimensions of the "Rolling-Effect" are discussed.  相似文献   

6.
PurposeBeta particles emitted by radioisotopes used in targeted radionuclide therapies (TRT) create Bremsstrahlung (BRS) which may affect SPECT quantification when imaging these isotopes. The purpose of the current study was to investigate the characteristics of Bremsstrahlung produced in tissue by three β-emitting radioisotopes used in TRT.MethodsMonte Carlo simulations of 177Lu, 188Re, and 90Y sources placed in water filled cylinders were performed. BRS yields, mean energies and energy spectra for (a) all photons generated in the decays, (b) photons that were not absorbed and leave the cylinder, and (c) photons detected by the camera were analyzed. Next, the results of simulations were compared with those from experiments performed on a clinical SPECT camera using same acquisition conditions and phantom configurations as in simulations.ResultsSimulations reproduced relatively well the shapes of the measured spectra, except for 90Y which showed an overestimation in the low energy range. Detailed analysis of the results allowed us to suggest best collimators and imaging conditions for each of the investigated isotopes. Finally, our simulations confirmed that the BRS contribution to the energy spectra in quantitative imaging of 177Lu and 188Re could be ignored.ConclusionsFor 177Lu and 188Re, BRS contributes only marginally to the total spectra recorded by the camera. Our analysis shows that MELP and HE collimators are the best for imaging these two isotopes. For 90Y, HE collimator should be used.  相似文献   

7.
A comprehensive computational fluid-dynamics-based study of a pleated wing section based on the wing of Aeshna cyanea has been performed at ultra-low Reynolds numbers corresponding to the gliding flight of these dragonflies. In addition to the pleated wing, simulations have also been carried out for its smoothed counterpart (called the 'profiled' airfoil) and a flat plate in order to better understand the aerodynamic performance of the pleated wing. The simulations employ a sharp interface Cartesian-grid-based immersed boundary method, and a detailed critical assessment of the computed results was performed giving a high measure of confidence in the fidelity of the current simulations. The simulations demonstrate that the pleated airfoil produces comparable and at times higher lift than the profiled airfoil, with a drag comparable to that of its profiled counterpart. The higher lift and moderate drag associated with the pleated airfoil lead to an aerodynamic performance that is at least equivalent to and sometimes better than the profiled airfoil. The primary cause for the reduction in the overall drag of the pleated airfoil is the negative shear drag produced by the recirculation zones which form within the pleats. The current numerical simulations therefore clearly demonstrate that the pleated wing is an ingenious design of nature, which at times surpasses the aerodynamic performance of a more conventional smooth airfoil as well as that of a flat plate. For this reason, the pleated airfoil is an excellent candidate for a fixed wing micro-aerial vehicle design.  相似文献   

8.
An approximate hemodynamic theory, which predicts the opening dynamics of the Lillehei-Kaster heart valve, is used in conjunction with an abrasive wear model to predict the wear process on the shields. The hemodynamic theory predicts markedly different opening dynamics between the mitral and aortic positions and is shown to give excellent correlation with the experimental results of other investigations. The abrasive wear model is also shown to give excellent correlation with the experiments of others when the abrasive wear coefficient is taken as k = 6.4 X 10(-6). The theoretical results of this effort and the experimental data from clinical explants of other investigators is used to predict that occluder dislodgement is unlikely in less than 90 yr for either the mitral or aortic positions (for a mean cardiac output of 3.8 l.min-1 and a mean heart rate of 70 beats min-1).  相似文献   

9.
Two experimental methods were used to produce wear striations in one direction on unworn teeth. These include: (1) sliding 22 American Indian (Juntunen site, Michigan; Late Woodland) newly erupted incisors, by hand, across a flat grass surface covered with fine loose sand; and (2) using a unidirectional motor driven mechanical wear machine to draw 56 modern human dental extractions across a flat glass surface covered with silicon carbide powder of different grit sizes. A scanning electron microscope examination of individual wear striation morphology indicates that these wear striations begin with broad pits and have extending grooves that become narrower; characteristics that indicate the motion of wear. Patterns of wear striations on the worn dentitions of American Indians (Juntunen site) and the paleocene primate Phenacolemur pagei show similar characteristics and correspond to the buccal phase of mastication when the mandible is drawn upward, forward and slightly medially into centric occlusion. The data provided by this study can be used to test competing hypotheses concerning the direction of mandibular movement during mastication and food preparation.  相似文献   

10.
A sliding distance-based finite element formulation was implemented to predict initial wear rates at the front and back surfaces of a commercially available modular polyethylene component during in vitro loading conditions. We found that contact area, contact stress, and wear at the back surface were more sensitive to the liner/shell conformity than the presence of multiple screw holes. Furthermore, backside linear and volumetric wear rates were at least three orders of magnitude less than respective wear estimates at the articulating surface. This discrepancy was primarily attributed to the difference in maximum sliding distances at the articulating surfaces (measured in mm) versus the back surface (measured in microm). This is the first study in which backside wear has been quantified and explicitly compared with frontside wear using clinically relevant metrics established for the articulating surface. The results of this study suggest that with a polished metal shell, the presence of screw holes does not substantially increase abrasive backside wear when compared with the effects of backside nonconformity.  相似文献   

11.
Large inter-patient variability in wear rate and wear direction have been a ubiquitous attribute of total hip arthroplasty (THA) cohorts. Since patients at the high end of the wear spectrum are of particular concern for osteolysis and loosening, it is important to understand why some individuals experience wear at a rate far in excess of their cohort average. An established computational model of polyethylene wear was used to test the hypothesis that, other factors being equal, clinically typical variability in regions of localized femoral head roughening could account for much of the variability observed clinically in both wear magnitude and wear direction. The model implemented the Archard abrasive/adhesive wear relationship, which incorporates contact stress, sliding distance, and (implicitly) bearing surface tribology. Systematic trials were conducted to explore the influences of head roughening severity, roughened area size, and roughened area location. The results showed that, given the postulated wear factor elevations, head roughening variability (conservatively) typical of retrieval specimens led to approximately a 30 degrees variation in wear direction, and approximately a 7-fold variation in volumetric wear rate. Since these data show that randomness in head scratching can account for otherwise-difficult-to-explain variations in wear direction and wear rate, third-body debris may be a key factor causing excessive wear in the most problematic subset of the THA population.  相似文献   

12.
Abstract

The material components and configurations inside biological materials (e.g. bone and tooth) are quite dissimilar compared to conventional engineering materials. Besides hydroxyapatite minerals and collagen proteins, non-collagenous proteins such as osteopontin are also a very important component in bone. The aim of this paper is to study the role of osteopontin on the mechanical strength of biological composites. The MD simulations were performed to investigate the failure energy of osteopontin in two different directions, i.e. the direction normal to surface (thickness direction) and the direction tangential to surface (interface direction). The FE simulations were then performed to investigate the effects of failure energy in different directions on biological composites. The results show that the failure energy of osteopontin is higher in the interface direction. Significant improvement in the mechanical behaviour of biological composites is also found with the increased failure energy in the interface direction. Contrarily, although lower failure energy of osteopontin is observed in the thickness direction, but it is also found that the mechanical behaviour of biological composites does not greatly affected by the failure energy in the thickness direction. The numerical investigation provides important insights into how the osteopontin affects the mechanical behaviour of biological composites.  相似文献   

13.
Ultra high molecular weight polyethylene (PE) remains the primary bearing surface of choice in total knee replacements (TKR). Wear is controlled by levels of cross-shear motion and contact stress. The aim of this study was to compare the wear of fixed-bearing total knee replacements with curved and flat inserts and to test the hypothesis that the flat inserts which give higher contact stresses and smaller contact areas would lead to lower levels of surface wear. A low-conforming, high contact stress knee with a low-medium level of cross shear resulted in significantly lower wear rates in comparison to a standard cruciate sacrificing fixed-bearing knee. The low wear solution found in the knee simulator was supported by fundamental studies of wear as a function of pressure and cross shear in the pin on plate system. Current designs of fixed-bearing knees do not offer this low wear solution due to their medium cross shear, moderate conformity and medium contact stress.  相似文献   

14.
Though changes in normal joint motions and loads (e.g., following anterior cruciate ligament injury) contribute to the development of knee osteoarthritis, the precise mechanism by which these changes induce osteoarthritis remains unknown. As a first step toward identifying this mechanism, this study evaluates computational wear simulations of a patellofemoral joint specimen wear tested on a knee simulator machine. A multibody dynamic model of the specimen mounted in the simulator machine was constructed in commercial computer-aided engineering software. A custom elastic foundation contact model was used to calculate contact pressures and wear on the femoral and patellar articular surfaces using geometry created from laser scan and MR data. Two different wear simulation approaches were investigated--one that wore the surface geometries gradually over a sequence of 10 one-cycle dynamic simulations (termed the "progressive" approach), and one that wore the surface geometries abruptly using results from a single one-cycle dynamic simulation (termed the "non-progressive" approach). The progressive approach with laser scan geometry reproduced the experimentally measured wear depths and areas for both the femur and patella. The less costly non-progressive approach predicted deeper wear depths, especially on the patella, but had little influence on predicted wear areas. Use of MR data for creating the articular and subchondral bone geometry altered wear depth and area predictions by at most 13%. These results suggest that MR-derived geometry may be sufficient for simulating articular cartilage wear in vivo and that a progressive simulation approach may be needed for the patella and tibia since both remain in continuous contact with the femur.  相似文献   

15.
A survey of macroscopic and microscopic wear patterns in the baleen of eight whale species (Cetacea: Mysticeti) discloses structural, functional, and life history properties of this neomorphic keratinous tissue, including evidence of intraoral water flow patterns involved in filter feeding. All baleen demonstrates wear, particularly on its medial and ventral edges, as flat outer layers of cortical keratin erode to reveal horn tubes, also of keratin, which emerge as hair‐like fringes. This study quantified five additional categories of specific wear: pitting of plates, scratching of plates, scuffing of fringes, shortening of fringes, and reorientation of fringes (including fringes directed between plates to the exterior of the mouth). Blue whale baleen showed the most pitting and sei whale baleen the most scratching; gray whale baleen had the most fringe wear. The location of worn baleen within the mouth suggests that direct contact with the tongue is not responsible for most wear, and that flowing water as well as abrasive prey or sediment carried by the flowing water likely causes pitting and scratching of plates as well as fringe fraying, scuffing, shortening, and reorientation. Baleen also has elevated vertical and horizontal ridges that are unrelated to wear; these are probably related to growth and may allow for age determination. J. Morphol. 277:453–471, 2016. © 2016 Wiley Periodicals, Inc.  相似文献   

16.
A method is described that will indicate the direction that an abrasive particle was traveling as it scored the surface of a brittle material. Light and scanning electron micrographs of glass, dentine, and enamel abraded by loose sand, steel carbide, and diamond indicate that partial Hertzian fracture cones are formed at the margins of wear striations during abrasion. The bases of these fracture cones face in the direction of travel of the abrasive particle and, therefore, indicate directionality. Because this method is based only on the consistent geometry of fracturing of brittle materials, it is independent of the loading of the abrasive particle. The only other method available to determine directionality of striations is unreliable since it uses the width of striations, and, hence, is dependent upon a consistent loading regime of the abrasive particle. This new method has direct application for determining the direction of movement of the jaws during mastication in living or fossil animals.  相似文献   

17.
It is known that surfactants can induce flow in unsaturated porous media due to the dependence of capillary pressure on surface tension. A commonly observed feature in systems with surfactant-induced flow is a transient wetting/drying/wetting sequence associated with the propagation of a surfactant solute front under monotonic flow conditions. Previous efforts to model surfactant-induced flow in relatively complex (e.g., two-dimensional systems) have not successfully incorporated hysteretic moisture retention properties. In this research, hysteretic, two-dimensional simulations of surfactant-induced flow were performed to assess the potential importance of considering hysteresis in such simulations. Hysteretic simulation results were compared to experimental data and to non-hysteretic simulations. The results suggest that the inclusion of hysteresis in numerical simulations can improve the match between simulated and experimental results in systems with surfactant-induced unsaturated flow. Furthermore, the inclusion of hysteresis in numerical simulations played a significant role in predicting the distribution of the contaminant and correct pressure head/moisture condition at the end of the experiment.  相似文献   

18.
This study presents a chain of simulations aimed at estimating the wear in a cervical disc implant and providing insight into the in vivo biomechanical performance of the implant. The simulation chain can start with determining a representative maximum range of motion (ROM) of a person's head. The ROM is used as motion input to a kinematic simulation of the cervical spine containing a disc implant. The cervical spine geometry is obtained from computed tomography (CT) scans and converted to STL format using reverse engineering software. The time histories of the loads imposed by the adjacent vertebrae on the implant, as well as the vertebral relative rotations can be extracted from the kinematic simulation. Alternatively, force and motion profiles prescribed by wear test protocols (e.g. ISO 18192-1 and ASTM F2423-05) can be used. The force and motion profiles are applied as boundary conditions to a non-linear finite element model (FEM) of the implant to determine the time-varying contact stress and slip velocity distributions at the interface between the two halves of the implant. The stresses and slip velocities are used in a linear wear model to estimate the wear rate distribution at the FEM's nodal points where contact occurs. Reverse engineering software is used to triangulate the contact surface so that the total wear volume can be calculated. The simulation chain's predicted wear rate shows good agreement with in vitro results in the literature. The simulation chain is thereby demonstrated to be suitable for comparative pre-experimental studies of spinal implant designs.  相似文献   

19.
This paper presents a theoretical investigation of a geometrically idealized artificial joint with micro-pocket-covered component and biphasic cartilage on the opposite articulating surface. The fluid that exudes from the biphasic cartilage fills and pressurizes the micro-pockets. In this way, a poro-elasto-hydrodynamic regime of lubrication is developed. Assuming that lower friction would result in lower adhesive wear, and neglecting the fatigue as well as the abrasive wear, the proposed bearing system hypothetically could reduce the amount of wear debris. Equations of the linear biphasic theory are applied for the confined and unconfined compression of the cartilage. The fluid pressure and the elastic deformation of the biphasic cartilage are explicitly presented. The effective and equilibrium friction coefficients are obtained for the particular configuration of this bearing system. The micro-pockets geometrical parameters (depth, radius, surface distribution and edge radius) must be established to reduce the local contact stresses, to assure low friction forces and to minimize the biphasic cartilage damage. The influence of the applied pressure, porosity of the micro-pocket-covered component, filling time, cartilage elasticity, permeability and porosity upon the micro-pockets depth is illustrated. Our results are based upon the previously published data for a biphasic cartilage.  相似文献   

20.
Herein we study, through all atom molecular dynamics simulations, the complex between hevein and two N-acetylated chitin oligomers, namely N,N(')-diacetylchitobiose and N,N('),N(")-triacetylchitotriose. The results of the simulations for two disaccharide complexes and one trisaccharide complex show that a carbohydrate oligomer is able to move on the surface of the relatively flat binding pocket of hevein, therefore occupying different binding subpockets. Statistical analysis methods were also applied in order to define the principal overall motions in the complexes, showing how the different ligands in the simulations modulate the protein motions. The oligosaccharide binding can be considered as defined by a subtle balance between enthalpic (formation of intermolecular interactions between the ligand and the receptor) and entropic (due mainly to the possibility for the sugar to move on the surface of the protein domain) effects, determining multiple binding conformations. This structural and dynamical view could parallel the results obtained by regularly used restrained MD simulations based on NOE NMR data that provide a well defined structure for both the disaccharide and trisaccharide complexes, and agrees with the observations for longer oligosaccharide chains.  相似文献   