首页 | 官方网站   微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 62 毫秒
1.
This paper presents a comparison between the dynamic behavior of a 250 kW stand-alone proton exchange membrane fuel cell power plant (PEM FCPP) and a 250 kW stand-alone microturbine (MT). Dynamic models for the two are introduced. To control the voltage and the power output of the PEM FCPP, voltage and power control loops are added to the model. For the MT, voltage, speed, and power control are used. Dynamic models are used to determine the response of the PEM FCPP and MT to a load step change. Simulation results indicate that the response of the MT to reach a steady state is about twice as fast as the PEM FCPP. For stand-alone operation of a PEM FCPP, a set of batteries or ultracapacitors is needed in order to satisfy the power mismatch during transient periods. Software simulation results are obtained by using MATLAB®, Simulink®, and SimPowerSystems®.  相似文献   

2.
This paper reports on the dynamic behavior of a 250 kW proton exchange membrane fuel cell power plant (PEM FCPP) and a 250 kW microturbine (MT) when operating in parallel. A load sharing control scheme is used to distribute the load equally between the PEM FCPP and the MT. For stand alone operation of a PEM FCPP, a set of batteries or ultracapacitors are needed in order to satisfy the power mismatch during transient periods. Using MT in parallel with the PEM FCPP helps in eliminating the need for storage devices. Models for the PEM FCPP and the MT with power, voltage and speed controls are used to determine the dynamic response of the system to a step change in the load. Simulation results indicate viability of parallel operation of the PEM FCPP and the MT. These results are obtained using MATLAB®, Simulink®, and SimPowerSystems®.  相似文献   

3.
A numerical model is developed from a stationary proton exchange membrane fuel cell (PEMFC) system comprising a PEMFC, a DC‐DC buck converter, an auxiliary power supply (a lithium battery and supercapacitor), and a DC‐AC inverter. The transient and steady‐state performance of the PEMFC system is investigated by means of Matlab/Simulink simulations. It is shown that a good agreement exists between the simulated polarization curve of the PEMFC and the experimental results presented in the literature. In addition, it is shown that the DC‐DC buck converter provides an effective means of stabilizing the output voltage of the PEMFC. Finally, the results confirm the effectiveness of the auxiliary power source in enabling the PEMFC to satisfy the peak load demand. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

4.
A fuel cell powered system is regarded as a high current and low voltage source. To boost the output voltage of a fuel cell, a DC/DC converter is employed. Since these two systems show different dynamics, they need to be coordinated to meet the demand of a load. This paper proposes models for the two systems with associated controls, which take into account a PEM fuel cell stack with air supply and thermal systems, and a PWM DC/DC converter. The integrated simulation facilitates optimization of the power control strategy, and analyses of interrelated effects between the electric load and the temperature of cell components. In addition, the results show that the proposed power control can coordinate the two sources with improved dynamics and efficiency at a given dynamic load.  相似文献   

5.
The proton exchange membrane fuel cell (PEMFC) stacks are not widely used in the field of transportation industry, due to their limited power. Thus, the PEMFC stacks usually connected in parallel or series to meet the load demand power in high-power applications. The hydrogen consumption of multi-stack fuel cells (MFCs) system is related to the efficiency and output power. In addition, the efficiency of PEMFC depends on the applied voltage and other parameters. Consequently, the hydrogen consumption of system changes with varying load, because the system parameters are also varying. It makes reducing the fuel consumption of system a challenging assignment. In order to achieve the goal of minimizing fuel consumption of parallel-connected PEMFCs system, this paper proposes a novel power distribution strategy based on forgetting factor recursive least square (FFRLS) online identification. The FFRLS algorithm is based on data-driven and uses real-time data of the system to improve the estimation accuracy of PEMFC system parameters. On the test bench of parallel-connected PEMFCs system consists of two 300 W PEMFC stacks, PEMFC stack controller, DC/DC converters, and DSP controller etc., a multi-index performance test and comparative analysis are carried out. The results showed that, the performance of proposed power allocation strategy has been successfully validated. In addition, compared with the power average and daisy chain algorithms, the proposed online identification power distribution method can get more satisfactory results. Such as, reducing the hydrogen consumption and improving efficiency.  相似文献   

6.
分析了质子交换膜燃料电池(PEMFC)的机理模型,在此基础上运用MATLAB的Simulink仿真工具,建立了PEMFC发电系统带负载模型。通过仿真,分析了负载对PEMFC电堆的各项动态特性(燃料的流量、效率、输出电压等)的影响,以及DC/DC、负载端的电压响应。仿真结果中负载电压呈三相交流正弦波形,表明搭建的整个PEMFC发电系统是基本正确的,为实现PEMFC并网的实时分析和动态优化提供了理论依据和参考方法。  相似文献   

7.
Because the AC impedance technique, also known as electrochemical impedance spectroscopy (EIS), is being utilized by more and more researchers in proton exchange membrane (PEM) fuel cell studies, the technique has developed into a primary tool in such research. In this paper the recent work on PEM fuel cells using the AC impedance technique is reviewed. Both in situ and ex situ impedance measurements are discussed, with primary focus on the in situ measurements. Within the domain of in situ studies, various methods for measuring the impedance of a PEM fuel cell are examined, and typical impedance spectra in several common scenarios are presented. Representative applications of the AC impedance technique in PEM fuel cell research are also discussed. Finally, the necessity of a time domain rapid AC impedance technique is briefly discussed.  相似文献   

8.
In order to improve the robustness of the energy management system (EMS) and avoid the influence of demand power on the design of EMS, a coupled power-voltage equilibrium strategy based on droop control (CPVE-DC) is proposed in this paper. Making use of the principal that the DC bus can directly reflect the changes of load power, the proposed strategy couples DC bus voltage with output powers through droop control to achieve self-equilibrium. The proposed EMS is applied into a hybrid tramway model configured with multiple proton exchange membrane fuel cell (PEMFC) systems, batteries and super capacitors (SCs). FC systems and SC systems are responsible for satisfying most of the demand power, therefore the CPVE-DC strategy generates FCs and SCs reference power through power-voltage droop control on the primary control. Then batteries supplement the rest part of load power and generate DC bus voltage reference value of the next sampling time. With the gambling between output power and DC bus voltage, the hybrid system achieves self-equilibrium and steps into steady operation by selecting appropriate droop coefficients. Then the secondary control of the proposed strategy allocates power between every single unit. In addition, a penalty coefficient is introduced to balance SOC of SCs. The proposed strategy is tested under a real drive cycle LF-LRV on RT-LAB platform. The results demonstrate that the proposed strategy can achieve self-equilibrium and is effective to allocate demand power among these power sources,achieve active control for the range of DC bus voltage and SOC consensus of SCs as well. In addition, some faults are simulated to verify the robustness of the proposed strategy and it turns out that the CPVE-DC strategy possesses higher robustness. Finally, the CPVE-DC strategy is compared with equivalent consumption minimization strategy (ECMS) and the results shows that the proposed strategy is able to get higher average efficiency and lower equivalent fuel consumption.  相似文献   

9.
The nonlinear loads create a wide range of current harmonics in the system. Such loads can make distortions on the output voltage profile, influence on the fuel cell (FC) performance, and endanger safe operation of the FC unit. In this paper, new strategies for power-following and AC voltage control have been developed. The proposed system consists of the ultracapacitor (UC) bank and proton exchange membrane fuel cell (PEMFC) supplying nonlinear AC loads. The power tracking strategy is based on the Fourier analysis of total load demand. The Fourier analysis is used as an effective tool to eliminate destructive effect of current harmonics on the PEMFC output current. To supply the nonlinear AC loads under sinusoidal voltage with the fast response, a dynamic model for the inverter control loop is also presented. This model is used to enhance the input reference tracking and reject input/output disturbances. The simulation outcomes confirm the desirable PEMFC performance against nonlinear load disturbances. In addition, the output AC voltage is kept sinusoidal and has low deviations under nonlinear load variations.  相似文献   

10.
沙德尚  孔力  孙晓 《太阳能学报》2004,25(2):227-231
燃料电池电压输出范围比较宽,电压比较低。针对该特点本文设计了DC/DC和DC/AC两级变换的功率调节系统(PCS)。其中DC/DC将燃料电池输出的低压直流电高频变换成高压直流电,变换器为电压单环控制。DC/AC逆变器采用基于电压电流瞬时值反馈的双闭环控制,将高压直流电逆变为正弦交流电。分析了整个功率调节系统的工作原理及逆变器电路参数对稳定性的影响。0.5KVA佯饥实验结果表明整个系统具有电压输入范围宽、变换效率高、输出波形THD小等优点。为开发高效、高功率密度的燃料电池电源系统提供技术基础。  相似文献   

11.
The energy use of the world grows continuously and the development of a clean distributed power generation becomes environmentally important. Fuel cells are one such integral part of Renewable Energy Sources based clean energy supply; that they operate with hydrogen as fuel and water with heat as process waste. Due to the electrochemical reaction, fuel cell has the power quality of delivering low voltage with high current capability. Here an attempt is made to develop a power conditioner with a series of conversion to get a 220 V sinusoidal AC, 50 Hz single phase voltage of low distortion and fast dynamic regulation to cater load variations. A novel Polyphase Boost DC-to-DC switching converter based on parallel connection of 8 identical converters with current mode control is devised to have minimum reflected ripple current and voltage injected to fuel cell input. A full bridge converter with high frequency transformer isolation, step-up the DC voltage level from the low voltage fuel cell along with poly phase boost converter, deliver required DC to the PWM inverter, which generate AC utility power output. Recent trend of Ultra-capacitor based transient energy storage and retrieval system, to cater for the sluggish behavior of fuel cell, for load transients is incorporated. DSP and FPGA based digital real time controllers are used to realize the gating of MOSFETs and IGBTs used in the power conditioner. A 1 kW power conditioner is developed for a PAFC fuel cell system with 12 V DC nominal and their performance evaluations are satisfactory.  相似文献   

12.
This paper describes dynamic modeling and simulation results of a small wind–fuel cell hybrid energy system. The system consists of a 400 W wind turbine, a proton exchange membrane fuel cell (PEMFC), ultracapacitors, an electrolyzer, and a power converter. The output fluctuation of the wind turbine due to wind speed variation is reduced using a fuel cell stack. The load is supplied from the wind turbine with a fuel cell working in parallel. Excess wind energy when available is converted to hydrogen using an electrolyzer for later use in the fuel cell. Ultracapacitors and a power converter unit are proposed to minimize voltage fluctuations in the system and generate AC voltage. Dynamic modeling of various components of this small isolated system is presented. Dynamic aspects of temperature variation and double layer capacitance of the fuel cell are also included. PID type controllers are used to control the fuel cell system. SIMULINKTM is used for the simulation of this highly nonlinear hybrid energy system. System dynamics are studied to determine the voltage variation throughout the system. Transient responses of the system to step changes in the load current and wind speed in a number of possible situations are presented. Analysis of simulation results and limitations of the wind–fuel cell hybrid energy system are discussed. The voltage variation at the output was found to be within the acceptable range. The proposed system does not need conventional battery storage. It may be used for off-grid power generation in remote communities.  相似文献   

13.
Composite film of carbon nanotube (CNT) and polytetrafluoroethylene (PTFE) was successfully formed by using their dispersion fluids. This CNT/PTFE composite film was electrically conductive in the range of 10 S cm−1. The proton exchange membrane fuel cell (PEMFC) was assembled with the stainless steel bipolar plate coated with the CNT/PTFE composite film. This coating decreased the contact resistance between the surface of the bipolar plate and the membrane electrode assemble (MEA). Therefore, the output power of the fuel cell increased by 1.6 times.  相似文献   

14.
In this paper a collaborative simulation platform for proton exchange membrane fuel cell (PEMFC) power systems is presented, where the stack is simulated by a two-phase distributed parameter model and the auxiliary units by lumped parameter models. By exchanging the dynamic data between the external load/auxiliary units and PEMFC stack, dynamic simulation of PEMFC stack has been carried out during the load changes for various states associated with different characteristic variables. The internal states of the stack can be observed due to variation of external load/auxiliary units. Numerical experiments are provided for a special case with multiple cycles of load changes derived from an acceleration mode of a fuel cell vehicle. The numerical results demonstrate that the “undershoot” of output voltage is due to the response lag of the auxiliary units and liquid water accumulation in the fuel cell stack.  相似文献   

15.
Fuel cell powered systems generally have a high current and a low voltage. Therefore, the output voltage of the fuel cell must be stepped-down using a DC-DC buck converter. However, since the fuel cell and converter have different dynamics, they must be suitably coordinated in order to satisfy the demanded load. Accordingly, this study commences by constructing a MATLAB/Simulink model of a proton exchange membrane fuel cell (PEMFC) system comprising a PEMFC stack, an air/fuel supply system, and a temperature control system. The validity of the PEMFC model is demonstrated by comparing the simulation results obtained for the polarzation curves of a single fuel cell with the corresponding experimental curves. A model is then constructed of the DC-DC buck converter used to step-down the PEMFC output voltage. In addition, a sliding mode control (SMC) scheme is proposed for the DC-DC buck converter which guarantees a low and stable output voltage given transient variations in the output voltage of the PEMFC. Finally, a model is constructed of a DC-AC inverter with a pulse width modulated (PWM) control scheme which enables the PEMFC stack to supply the grid or power AC applications directly. Overall, the combined PEMFC/DC-DC buck converter/DC-AC inverter model provides a powerful and versatile tool for the design and development of a wide range of PEMFC power systems.  相似文献   

16.
Traditional sliding mode controller applied to a DC/DC boost converter for the improvement and optimization of the proton exchange membrane fuel cell (PEMFC) system efficiency, has the drawback of chattering phenomenon. Thus, based on the analysis of the mathematical model of PEMFC, this paper addresses the second order super twisting algorithm (STA) as a solution of chattering reduction, Stability of the closed loop system is analytically proved using Lyapunov approach for the proposed controller. The model and the controllers are implemented in the MATLAB and SIMULINK environment. A comparison of results indicates that the suggested approach has considerable advantages compared to the classical sliding mode control.  相似文献   

17.
In this work a state and transfer function model of the set made up of a proton exchange membrane (PEM) fuel cell and a DC/DC converter is developed. The set is modelled as a plant controlled by the converter duty cycle. In addition to allow setting the plant operating point at any point of its characteristic curve (two interesting points are maximum efficiency and maximum power points), this approach also allows the connection of the fuel cell to other energy generation and storage devices, given that, as they all usually share a single DC bus, a thorough control of the interconnected devices is required. First, the state and transfer function models of the fuel cell and the converter are obtained. Then, both models are related in order to achieve the fuel cell+DC/DC converter set (plant) model. The results of the theoretical developments are validated by simulation on a real fuel cell model.  相似文献   

18.
Proton exchange membrane fuel cell (PEMFC), according to its merits of high energy density, zero emission, and low noise, has been widely applied in industrial appliances. A full bridge converter is used to implement PEMFC-powered DC motor bidirectional rotation in this paper. For the sake of the regulations of DC motor angular velocity as well as bus voltage, an adaptive backstepping sliding-mode control (ABSMC) technique integrated with Chebyshev neural network (CNN) is proposed. Based on the equivalent-circuit method, the control-oriented model of the PEMFC-powered motor system is structured. By constructing Lyapunov function, the adaptive laws and control laws can be obtained to achieve bus voltage and angular velocity regulations simultaneously. Moreover, the proposed neural network is applied to estimate the uncertainties of the system through orthogonal basis Chebyshev polynomials. To highlight the advantages of proposed technique, a proportional-integral (PI) control was introduced subsequently and two controllers were compared via numerical simulations. The simulation results demonstrate that CNN estimation method in conjunction with backstepping sliding-mode shows fast and accurate response even though the existence of system uncertainties and external disturbances.  相似文献   

19.
A hybrid system combining a 2 kW air-blowing proton exchange membrane fuel cell (PEMFC) stack and a lead–acid battery pack is developed for a lightweight cruising vehicle. The dynamic performances of this PEMFC system with and without the assistance of the batteries are systematically investigated in a series of laboratory and road tests. The stack current and voltage have timely dynamic responses to the load variations. Particularly, the current overshoot and voltage undershoot both happen during the step-up load tests. These phenomena are closely related to the charge double-layer effect and the mass transfer mechanisms such as the water and gas transport and distribution in the fuel cell. When the external load is beyond the range of the fuel cell system, the battery immediately participates in power output with a higher transient discharging current especially in the accelerating and climbing processes. The DC–DC converter exhibits a satisfying performance in adaptive modulation. It helps rectify the voltage output in a rigid manner and prevent the fuel cell system from being overloaded. The dynamic responses of other operating parameters such as the anodic operating pressure and the inlet and outlet temperatures are also investigated. The results show that such a hybrid system is able to dynamically satisfy the vehicular power demand.  相似文献   

20.
This paper studies the transient response of the output voltages of a Ballard-Mark-V 35-cell 5 kW proton exchange membrane fuel cell (PEMFC) stack with power conversion for applications in autonomous underwater vehicles (AUVs) under load changes. Four types of pulse-width modulated (PWM) dc-dc power converters are employed to connect to the studied fuel cell in series for converting the unregulated fuel cell stack voltage into the desired voltage levels. The fuel cell model in this paper consists of the double-layer charging effect, gases diffusion in the electrodes, and the thermodynamic characteristic; PWM dc-dc converters are assumed to operate in continuous-conduction mode with a voltage-mode control compensator. The models of the study's fuel cell and PWM dc-dc converters have been implemented in a Matlab/SIMULINKTM environment. The results show that the output voltages of the studied PEMFC connected with PWM dc-dc converters during a load change are stable. Moreover, the model can predict the transient response of hydrogen/oxygen out flow rates and cathode and anode channel temperatures/pressures under sudden change in load current.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司    京ICP备09084417号-23

京公网安备 11010802026262号