共查询到17条相似文献,搜索用时 46 毫秒
1.
本文叙述了背射式穆斯堡尔谱仪用的β共振探测器的工作原理、特点、结构和它的性能,通过实测得到了不锈钢、铁板、α铁的穆斯堡尔背散射谱。 相似文献
2.
3.
多路背散射穆斯堡尔谱仪包括多丝正比室、多路数据获取和处理系统(包含有多路前放和数字单道、多路数据获取单元、控制微机和图像显示器)。该谱仪具有高的几何效率,可实时数据采集和处理,可以同时获取几个来自不同深度和方向的信息。 相似文献
4.
通过计算机的声卡以及辅助电路把穆斯堡尔谱仪的速度参考信号和差误信号在计算机上实时采样分析,从而可以随时监控谱仪的运动情况,确保谱仪的工作质量。 相似文献
5.
6.
7.
8.
9.
本文描述了用8031单片机组成的穆斯堡尔谱仪的数据采集和传输系统的硬件和软件。系统道数为512道,每道计数容量为10^8-1。系统直接与IBMPC/XT及其兼容机相连构成计算机穆斯堡尔谱仪。 相似文献
10.
本文叙述了微机化穆斯堡尔谱仪数据采集控制器的工作原理,并着重介绍了采用DAC输出方式的函数发生器和用可调参数来调整起始道延迟的方法,改进穆斯堡尔谱折叠谱的获取指标。使所测得的折叠谱与相同条件下的单谱具有几乎相同水平的测量指标,对0.25μm的αFe3,4峰的平均线宽为0.221mm/s,非线性度优于0.12%。 相似文献
11.
《核技术(英文版)》2016,(6):190-194
In this study,we present a new method for the indirect integration of beam charges in external beam proton-induced X-ray emission and proton-induced c-ray emission(PIXE–PIGE) analysis.We recorded proton spectra backscattered by a Kapton film extraction window in different sample situations and under different beam currents.We also simulated backscattering spectra using the simulation of backscattering spectra program(SIMNRA).We determined that in a specific geometrical arrangement,different sample situations did not significantly affect factor C_Q(the ratio between integral backscattering proton counts and integral beam charges).We also studied the reproducibility and beam current dependence of factor C_Q.The statistic factor of C_Q was28.95 ± 0.6 kilo counts/l C,with a relative standard deviation of 2.0 %.Significantly,in external beam PIXE–PIGE analysis,we were able to calculate beam charge integration from the integral backscattering proton counts in an energy region. 相似文献
12.
CHENG Cheng WEI Yong-Bo XU Hui-Chao ZHAO Cui-Lan ZHANG Jin-Zhou PU Shi-Jie JIANG Da-Zhen 《核技术(英文版)》2006,17(2):106-112
A kind of excellent CdZnTe crystal has been grown in Yinnel Tech, Inc. in recent years. Based on these CdZnTe crystals and some new techniques, a portable energy-dispersive spectrometer has been constructed which has yielded good results. CdZnTe detector has a 3% relative resolution in high-energy field and can detect gamma rays at room temperature. An integrated circuit based on preamplifier and shaping amplifier chips is connected to the detector. Voltage pulses are transformed into digital signals in MCA (multichannel analyzer) and are then transmitted to computer via USB bus. Data process algorithms are improved in this spectrometer. Fast Fourier transform (FFT) and numerical differentiation (ND) are used in energy peak's searching program. Sampling-based correction technique is used in X-ray energy calibration. Modified Gaussian-Newton algorithm is a classical method to solve nonlinear curve fitting problems, and it is used to compute absolute intensity of each detected characteristic line. 相似文献
13.
14.
15.
16.
用超薄窗Si(Li)探测器测量低能X射线,将传统的PIXE谱测量范围推广到如Si、Al、Na等低原子序数元素。还对超薄窗Si(Li)探测器的具体应用作了描述。 相似文献
17.
介绍了一个原有穆斯堡尔谱仪硬件基础上开发的基于Windows的数据获取系统,同基于MS-DOS的数据获限系统相比,新系统具有人机交互方便、多线程工作方式、充分利用Windows资源等特点。 相似文献