首页 | 官方网站   微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.

Introduction

Recent publication of multi-ethnic spirometry reference equations for subjects aged from 3-95 years aim to avoid age-related discontinuities and provide a worldwide standard for interpreting spirometric test results.

Objectives

To assess the agreement of the Global Lung Function Initiative (GLI-2012) and All ages (FEV0.5) reference equations with the Spanish preschool lung function data. To verify the appropriateness of these reference values for clinical use in Spanish preschool children.

Methods

Spirometric measurements were obtained from children aged 3 to 6 years attending 10 randomly selected schools in Barcelona (Spain). Stanojevic's quality control criteria were applied. Z-scores were calculated for the spirometry outcomes based on the GLI equations. If the z-score (mean) of each parameter was close to 0, with a maximum variance of ± 0.5 from the mean and a standard deviation of 1, the GLI-2012 equations would be applicable in our population.

Results

Of 543 children recruited, 405 (74.6%) were ‘healthy’, and of these, 380 were Caucasians. Of these 380, 81.6% (169 females, 141 males) performed technically acceptable and reproducible maneuvers to assess FEVt, and 69.5% achieved a clear end-expiratory plateau. Z-scores for FVC, FEV1, FEV1/FVC, FEV0.75, FEV0.75/FVC, FEV0.5, FEF75 and FEF25-75 all fell within ± 0.5, except for FEV1/FVC (0.53 z-scores).

Conclusions

GLI equations are appropriate for Spanish preschool children. These data provide further evidence to support widespread application of the GLI reference equations.  相似文献   

2.
Background and objective: As firefighters are at increased risk of adverse health effects, periodic examination of their respiratory health is important. The objective of this study was to establish whether the use of impulse oscillometry (IOS) reveals respiratory abnormalities in metropolitan firefighters that go undetected during routine respiratory health screening by spirometry and assessment of respiratory symptoms. Methods: This was a cross‐sectional analysis of spirometry, IOS and questionnaire data from 488 male firefighters. Abnormal spirometry was defined as FEV1, FEV1/FVC and/or FEF50 below the lower limit of normal. Abnormal IOS was defined as resistance at 5 Hz (R5), frequency dependence of resistance (ΔR5‐R20) and/or reactance area (AX) above the upper limit of normal. Respiratory symptoms, smoking history, exposures and medical history were assessed. Data were analysed using logistic and linear regression models. Results: The mean age of the firefighters was 43.8 (SD 8.4) years. There were 123 (25%) former smokers and 50 (10%) current smokers. Abnormal spirometry was detected in 12%, abnormal IOS in 9% and respiratory symptoms in 20% of firefighters. Current smoking was associated with all IOS parameters (OR for R5 = 3.1, OR for ΔR5‐R20 = 7.7, OR for AX = 4.3), and with FEF50 (OR = 9.1), chronic productive cough (OR = 4.0) and breathlessness (OR = 5.4) (P < 0.05 for all). Exposure during firefighting duties was associated with chronic productive cough (OR = 2.6), but not with spirometry or IOS parameters. Interaction terms in the linear regression models indicated associations between smoking and ΔR5‐R20, and also between smoking and AX, in the lowest and second lowest quartiles of spirometry parameters. Conclusions: Application of IOS for the assessment of respiratory health in firefighters identified airways dysfunction in some individuals, even when spirometry values were within the normal range and there were no respiratory symptoms.  相似文献   

3.

Background

Occupational mineral dust exposure is a well-known risk factor for numerous respiratory and systemic diseases. The aim of the present longitudinal study was to assess the influence of work-associated dust exposure on spirometric results. Furthermore, the impact of implementation of stricter limit values for occupational contact with quartz dust on lung function was evaluated.

Methods

Anthropometric data (age, gender, BMI), smoking behavior, and lung function parameters (FVC, FEV1, MEF50) from 7,204 medical examinations of 3,229 female and male workers during the years 2002–2010 were examined following Austrian standards for occupational medicine and the guidelines of the European Respiratory Society. Analysis of data was performed using models of multiple linear regression.

Results

Lung function decrease over time was associated with smoking habits and duration of occupational dust exposure. Specifically, occupational quartz exposure negatively influenced the annual lung function parameters (FVC, ?6.68 ml; FEV1, ?6.71 ml; and MEF50, ?16.15 ml/s, all p < 0.001). Thus, an overadditive effect of smoking and work-related contact with quartz was found regarding decline in MEF50 (p < 0.05). Implementation of stricter occupational limit values for dust exposure resulted in a highly significant deceleration of the annual decrease in respiratory function (p = 0.001).

Conclusions

Individual smoking habits and occupational dust exposure had a negative impact on lung function. To reduce the risk of loss of respiratory capacity, smoking cessation is especially recommended to workers exposed to quartz dust. Moreover, stricter limit values could prevent chronic occupational damage to the respiratory system.  相似文献   

4.

BACKGROUND:

Currently, no reference or normative values for spirometry based on a randomly selected Canadian population exist.

OBJECTIVE:

The aim of the present analysis was to construct spirometric reference values for Canadian adults 20 to 90 years of age by combining data collected from healthy lifelong nonsmokers in two population-based studies.

METHOD:

Both studies similarly used random population sampling, conducted using validated epidemiological protocols in the Canadian Obstructive Lung Disease study, and the Lung Health Canadian Environment study. Spirometric lung function data were available from 3042 subjects in the COLD study, which was completed in 2009, and from 2571 subjects in the LHCE study completed in 1995. A total of 844 subjects 40 to 90 years of age, and 812 subjects 20 to 44 years of age, were identified as healthy, asymptomatic, lifelong nonsmokers, and provided normative reference values for spirometry. Multiple regression models were constructed separately for Caucasian men and women for the following spirometric parameters: forced expiratory volume in 1 s (FEV1), forced vital capacity (FVC) and FEV1/FVC ratio, with covariates of height, sex and age. Comparison with published regression equations showed that the best agreement was obtained from data derived from random populations.

RESULTS:

The best-fitting regression models for healthy, never-smoking, asymptomatic European-Canadian men and women 20 to 90 years of age were constructed. When age- and height-corrected FEV1, FVC and FEV1/FVC ratio were compared with other spirometry reference studies, mean values were similar, with the closest being derived from population-based studies.

CONCLUSION:

These spirometry reference equations, derived from randomly selected population-based cohorts with stringently monitored lung function measurements, provide data currently lacking in Canada.  相似文献   

5.
Objective: There is controversy about the diagnostic criteria, prevalence, symptoms, and spirometry characteristics of asthma–chronic obstructive pulmonary disease (COPD) overlap (ACO). Recent data indicate that the fixed method for diagnosing airway obstruction (AO) may overestimate ACO prevalence in the elderly, and a variable method may be more accurate. We aimed at estimating ACO prevalence in a general population sample and comparing patient and clinical features in subjects with ACO, COPD, and asthma. Methods: We analyzed data from a cross-sectional study estimating COPD prevalence in randomly selected adults aged 20–79 years in Verona, Italy, and estimated prevalence and analyzed characteristics of asthma, COPD, and ACO. ACO was defined as AO (Forced Expiratory Volume in one second–FEV1/ Forced Vital Capacity–FVC < Lower Limit of Normal–LLN), highly positive bronchodilator test (≥15% increase in FEV1 and FVC ≥400 mL), and personal self-reported history of physician diagnosed asthma and atopy. Results: One thousand two hundred and thirty-six patients were included; 207 (16.7%) had asthma, COPD, or ACO (mean ages: 61.2, 59.7, and 57.2 years, respectively). The 3 groups had similar clinical and demographic variables; however, spirometry revealed differences between ACO and COPD patients, particularly post-bronchodilator FEV1 reversibility, which was detected in ACO and asthma patients but not in those with COPD. Conclusion: ACO prevalence in Northern Italy was estimated at 2.1%, in the range of values reported by previous studies. Marked differences between ACO and COPD revealed by spirometry may have important clinical implications in terms of treatment for patients with ACO.  相似文献   

6.

OBJECTIVE:

To investigate the presence of airway obstruction by determining the FEV1/FVC and FEV1/slow vital capacity (SVC) ratios.

METHODS:

This was a quantitative, retrospective cross-sectional study. The sample comprised 1,084 individuals who underwent spirometry and plethysmography in a central hospital in Lisbon, Portugal. The study sample was stratified into six groups, by pulmonary function.

RESULTS:

The analysis of the FEV1/FVC ratio revealed the presence of airway obstruction in 476 individuals (43.9%), compared with 566 individuals (52.2%) for the analysis of the FEV1/SVC ratio. In the airway obstruction, airway obstruction plus lung hyperinflation, and mixed pattern groups, the difference between SVC and FVC (SVC − FVC) was statistically superior to that in the normal pulmonary function, reduced FEF, and restrictive lung disease groups. The SVC − FVC parameter showed a significant negative correlation with FEV1 (in % of the predicted value) only in the airway obstruction plus lung hyperinflation group.

CONCLUSIONS:

The FEV1/SVC ratio detected the presence of airway obstruction in more individuals than did the FEV1/FVC ratio; that is, the FEV1/SVC ratio is more reliable than is the FEV1/FVC ratio in the detection of obstructive pulmonary disease.  相似文献   

7.

BACKGROUND:

Bronchodilator responses (BDR) are routinely used in the diagnosis and management of asthma; however, their acceptability and repeatability have not been evaluated using quality control criteria for preschool children.

OBJECTIVES:

To compare conventional spirometry with an impulse oscillometry system (IOS) in healthy and asthmatic preschool children.

METHODS:

Data from 30 asthmatic children and 29 controls (two to six years of age) who underwent IOS and spirometry before and after salbutamol administration were analyzed.

RESULTS:

Stable asthmatic subjects significantly differed versus controls in their spirometry-assessed BDR (forced expiratory volume in 1 s [FEV1], forced vital capacity and forced expiratory flow at 25% to 75% of forced vital capacity) as well as their IOS-assessed BDR (respiratory resistance at 5 Hz [Rrs5], respiratory reactance at 5 Hz and area under the reactance curve). However, comparisons based on the area under the ROC curve for ΔFEV1 % initial versus ΔRrs5 % initial were 0.82 (95% CI 0.71 to 0.93) and 0.75 (95% CI 0.62 to 0.87), respectively. Moreover, the sensitivity and specificity for ΔFEV1 ≥9% were 0.53 and 0.93, respectively. Importantly, sensitivity increased to 0.63 when either ΔFEV1 ≥9% or ΔRrs5 ≥29% was considered as an additional criterion for the diagnosis of asthma.

CONCLUSION:

The accuracy of asthma diagnosis in preschool children may be increased by combining spirometry with IOS when measuring BDR.  相似文献   

8.
9.

Objective:

To evaluate the changes in lung function in the first year after single lung transplantation in patients with idiopathic pulmonary fibrosis (IPF).

Methods:

We retrospectively evaluated patients with IPF who underwent single lung transplantation between January of 2006 and December of 2012, reviewing the changes in the lung function occurring during the first year after the procedure.

Results:

Of the 218 patients undergoing lung transplantation during the study period, 79 (36.2%) had IPF. Of those 79 patients, 24 (30%) died, and 11 (14%) did not undergo spirometry at the end of the first year. Of the 44 patients included in the study, 29 (66%) were men. The mean age of the patients was 57 years. Before transplantation, mean FVC, FEV1, and FEV1/FVC ratio were 1.78 L (50% of predicted), 1.48 L (52% of predicted), and 83%, respectively. In the first month after transplantation, there was a mean increase of 12% in FVC (400 mL) and FEV1 (350 mL). In the third month after transplantation, there were additional increases, of 5% (170 mL) in FVC and 1% (50 mL) in FEV1. At the end of the first year, the functional improvement persisted, with a mean gain of 19% (620 mL) in FVC and 16% (430 mL) in FEV1.

Conclusions:

Single lung transplantation in IPF patients who survive for at least one year provides significant and progressive benefits in lung function during the first year. This procedure is an important therapeutic alternative in the management of IPF.  相似文献   

10.
Background and objective: Pulmonary function tests play an important role in the management of pulmonary diseases. One of the tests that are widely used is spirometry. Performing an acceptable spirometry manoeuvre according to the standards set by the American Thoracic Society/European Respiratory Society is difficult. The aim of this study was to compare forced expiratory volume in 3 s (FEV3) and forced expiratory volume in 6 s (FEV6) with forced vital capacity (FVC), and forced expiratory volume in 1 s FEV1/FEV3 and FEV1/FEV6 with FEV1/FVC, in order to substitute the usual spirometric manoeuvres with manoeuvres that are easier to perform. Methods: In a cross‐sectional study, spirometry was performed for 588 subjects who were referred for occupational health evaluations. The accuracy of FEV3, FEV6, FEV1/FEV3 and FEV1/FEV6 was compared with that of FVC and FEV1/FVC. Chi‐square tests and kappa tests were used to analyse the data. Results: Individuals with normal (n = 297) and abnormal spirometry (n = 291) were evaluated. The sensitivity, specificity, positive predictive value and negative predictive value of FEV1/FEV6, as compared with that of FEV1/FVC for detecting obstruction, were 93.56, 99.32, 98.95 and 96.09, respectively. The sensitivity, specificity, positive predictive value and negative predictive value of FEV6, as compared with that of FVC for detecting restriction, were 96.68, 98.65, 96.68 and 98.65, respectively. Conclusions: FEV6 and FEV1/FEV6 can be used as surrogates for FVC and FEV1/FVC, respectively, and these parameters showed acceptable sensitivity, specificity, positive predictive value and negative predictive value for occupational health evaluations.  相似文献   

11.
Background and Objectives

Indigenous Respiratory Outreach Care (IROC) is a culturally appropriate specialist respiratory service established to deliver multidisciplinary respiratory care to regional and remote Queensland communities. Our objective was to evaluate the impact of an outreach specialist respiratory service on the spirometry of children attending IROC clinics, particularly Indigenous children with asthma and bronchiectasis.

Methods

Retrospective single-arm cohort study of 189 children who performed spirometry at twelve sites across regional and remote Queensland between October 2010 and December 2017. Each child’s baseline spirometry was compared to their best spirometry at follow-up visit occurring within (1) 12 months of their most recent visit with at least 12 months of specialist care and; (2) each year of their first 3 years of care.

Results

Forced expiratory volume in one second (FEV1) and forced vital capacity (FVC) z-scores improved significantly across the whole group from baseline to follow-up (change in z-scores (Δz) of FEV1 = 0.38, 95% CI 0.22, 0.53; ΔzFVC = 0.36, 95% CI 0.21, 0.51). In subgroup analyses, lung function significantly improved in Indigenous children (n = 141, ΔzFEV1 = 0.37, 95% CI 0.17, 0.57; ΔzFVC = 0.36, 95% CI 0.17, 0.55) including those with asthma (n = 117, ΔzFEV1 = 0.41, 95% CI 0.19, 0.64; ΔzFVC = 0.46, 95% CI 0.24, 0.68) and bronchiectasis (n = 38, ΔzFEV1 = 0.33, 95% CI 0.07, 0.59; ΔzFVC = 0.26, 95% CI − 0.03, 0.53). Significant improvements in FEV1 and FVC were observed within the first and second year of follow-up for Indigenous children, but not for non-Indigenous children.

Conclusion

The IROC model of care in regional and remote settings leads to significant lung function improvement in Indigenous children with asthma and bronchiectasis.

  相似文献   

12.

Objective:

Pregnancy brings about significant changes in respiratory function, as evidenced by alterations in lung volumes and capacities, which are attributable to the mechanical impediment caused by the growing foetus. This study was undertaken in order to identify changes in respiratory function during normal pregnancy and to determine whether such changes are more pronounced in twin pregnancy than in singleton pregnancy.

Methods:

Respiratory function was assessed in 50 women with twin pregnancies and in 50 women with singleton pregnancies (during the third trimester in both groups), as well as in 50 non-pregnant women. We measured the following pulmonary function test parameters: FVC; FEV1; PEF rate; FEV1/FVC ratio; FEF25-75%; and maximal voluntary ventilation.

Results:

All respiratory parameters except the FEV1/FVC ratio were found to be lower in the pregnant women than in the non-pregnant women. We found no significant differences between women with twin pregnancies and those with singleton pregnancies, in terms of respiratory function.

Conclusions:

Despite its higher physiological demands, twin pregnancy does not appear to impair respiratory function to any greater degree than does singleton pregnancy.  相似文献   

13.

Introduction

To investigate the association of individual and contextual exposures with lung function by gender in rural-dwelling Canadians.

Methods

A cross-sectional mail survey obtained completed questionnaires on exposures from 8263 individuals; a sub-sample of 1609 individuals (762 men, 847 women) additionally participated in clinical lung function testing. The three dependent variables were forced expired volume in one second (FEV1), forced vital capacity (FVC), and FEV1/FVC ratio. Independent variables included smoking, waist circumference, body mass index, indoor household exposures (secondhand smoke, dampness, mold, musty odor), occupational exposures (grain dust, pesticides, livestock, farm residence), and socioeconomic status. The primary analysis was multiple linear regression, conducted separately for each outcome. The potential modifying influence of gender was tested in multivariable models using product terms between gender and each independent variable.

Results

High-risk waist circumference was related to reduced FVC and FEV1 for both genders, but the effect was more pronounced in men. Greater pack-years smoking was associated with lower lung function values. Exposure to household smoke was related to reduced FEV1, and exposure to livestock, with increased FEV1. Lower income adequacy was associated with reduced FVC and FEV1.

Conclusion

High-risk waist circumference was more strongly associated with reduced lung function in men than women. Longitudinal research combined with rigorous exposure assessment is needed to clarify how sex and gender interact to impact lung function in rural populations.
  相似文献   

14.

Purpose of Review

Chronic respiratory diseases affecting adults and children are widely prevalent, so lung function testing is imperative for diagnosis and management. Spirometry is the traditional standard measure of lung function; however, certain groups of patients are unable to provide accurate and reproducible exhalation maneuvers. Consequently, the impedance oscillometry system (IOS) has been developed as an effort, independent technique to assess airway function in children and the elderly. To better understand this emerging modality, the following review will compare IOS with spirometry, examine the function of the device, provide interpretation strategies, and discuss the evidence supporting its use in adults and children with chronic lung disease.

Recent Findings

In a population of symptomatic adults with suspected COPD, impedance oscillometry resistance measurements correlate with FEV1 and lung resistance increases with the severity of airflow limitation. In patients with asthma, IOS is a sensitive measure of airway hyperresponsiveness and bronchodilator response.

Summary

Impedance oscillometry is evolving as an alternative measure to assess lung function pediatric and adult populations.
  相似文献   

15.

Background

Lymphangioleiomyomatosis (LAM) is a progressive, cystic lung disease that causes an obstructive ventilatory impairment similar to chronic obstructive pulmonary disease (COPD) and impairs the health-related quality of life (HRQoL). Here, we extended the use of the COPD assessment test (CAT) to patients with chronic respiratory diseases other than COPD. Specifically, the CAT was administered to patients with LAM for the first time.

Methods

Using data from 25 patients with LAM at Juntendo University who participated in the Multicenter Lymphangioleiomyomatosis Sirolimus Trial for Safety (MLSTS), we evaluated changes in pulmonary function, responses to HRQoL questionnaires (the CAT, St. George?s Respiratory Questionnaire [SGRQ], EuroQOL Visual Analogue Scale [EuroQOL-VAS], and Functional Performance Inventory [FPI]), and the association between pulmonary function and HRQoL during a 24-month period of sirolimus treatment.

Results

Forced expiratory volume in one second (FEV1), forced vital capacity (FVC), and CAT total scores improved over the 24 months of sirolimus treatment (5.33 ± 1.20?ml/month, 2.61 ± 1.16?ml/month, and ?0.127 ± 0.022 score/month, respectively), whereas SGRQ total score, EuroQOL-VAS score, and FPI score did not. Most pulmonary functions at baseline were associated with the CAT breathlessness score during the first year. Longitudinal changes in FEV1, FEV1%predicted, or FEV1/FVC correlated significantly with the scores of CAT total, CAT breathlessness, and SGRQ activity. When analyzed by stepwise multivariate regression within a linear mixed-effects model, CAT breathlessness and confidence scores were significantly associated with a change in FEV1 from the baseline value (P = 0.0011, and P = 0.0441).

Conclusion

Our results suggest that the CAT is a useful instrument for assessing HRQoL in sirolimus-treated patients with LAM.  相似文献   

16.

Background

Bronchial dilation testing is an important tool to assess airway reversibility in adults with bronchiectasis. This study aims to investigate the association of bronchodilator response (BDR) and clinical parameters in bronchiectasis, and the utility of BDR to indicate lung function decline and risks of bronchiectasis exacerbations (BEs).

Methods

We recruited 129 patients with clinically stable bronchiectasis. Baseline measurements included assessment of sputum inflammation and matrix metalloproteinase-8 and -9, sputum bacterial culture, spirometry, bronchial dilation test (for baseline FEV1 less than 80% predicted only) and chest high-resolution computed tomography (HRCT). Bronchiectasis patients were followed-up for 1 year to determine the incidence of BEs and lung function trajectories. Significant BDR was defined as FEV1 improvement from pre-dose value by at least 200 mL and 12%. Clinical trial registry No.: NCT01761214; URL: www.clinicaltrials.gov.

Results

BDR was negatively correlated with baseline FEV1 percentage predicted, but not blood or sputum eosinophil count. Significant BDR was not associated with greater proportion of never-smokers, poorer past history, greater HRCT scores, poorer diffusing capacity or increased sputum matrix metalloproteinases (all P>0.05). There was a trend towards higher bronchiectasis severity index (BSI) and greater proportion of patients with Pseudomonas aeruginosa isolation or infection. Significant BDR at baseline was linked to poorer spirometry, but not more rapid lung function decline, throughout follow-up. Patients with significant BDR demonstrated non-significantly lower risks of experiencing the first BEs than those without (P=0.09 for log-rank test).

Conclusions

Significant BDR is associated with poorer lung function compared with non-significant BDR. Whether BDR predicts future risks of BEs needs to be tested in a larger cohort.  相似文献   

17.

Background and Objective

The measurement of breathing pattern in patients with chronic obstructive pulmonary disease (COPD) by electrical impedance tomography (EIT) requires the use of a mathematical calibration model incorporating not only anthropometric characteristics (previously evaluated in healthy individuals) but probably functional alterations associated with COPD as well. The aim of this study was to analyze the association between EIT measurements and spirometry parameters, static lung volumes, and carbon monoxide diffusing capacity (DLCO) in a group of male patients to develop a calibration equation for converting EIT signals into volume signals.

Materials and Methods

We measured forced vital capacity (FVC), forced expiratory volume in 1 second (FEV1), FEV1/FVC, residual volume, total lung capacity, DLCO, carbon monoxide transfer coefficient (KCO) and standard anthropometric parameters in 28 patients with a FEV1/FVC ratio of <70%. We then compared tidal volume measurements from a previously validated EIT unit and a standard pneumotachometer.

Results

The mean (SD) lung function results were FVC, 72 (16%); FEV1, 43% (14%); FEV1/FVC, 42% (9%); residual volume, 161% (44%); total lung capacity, 112% (17%); DLCO, 58% (17%); and KCO, 75% (25%). Mean (SD) tidal volumes measured by the pneumotachometer and the EIT unit were 0.697 (0.181) L and 0.515 (0.223) L, respectively (P<.001). Significant associations were found between EIT measurements and CO transfer parameters. The mathematical model developed to adjust for the differences between the 2 measurements (R2=0.568; P<.001) was compensation factor=1.81?− 0.82?× height (m)?−0.004×KCO (%).

Conclusions

The measurement of breathing pattern by EIT in patients with COPD requires the use of a previously calculated calibration equation that incorporates not only individual anthropometric characteristics but gas exchange parameters as well.  相似文献   

18.

Background and Objective

Environmental exposure to phthalates and bisphenol A (BPA), chemicals used in the production of plastics, may increase risk for asthma and allergies. However, little is known about the long-term effects of early life exposure to these compounds. We investigated if prenatal exposure to these compounds was associated with asthma, allergy and lung function outcomes from early childhood into adulthood in a cohort study.

Methods

Maternal serum samples collected from 846 pregnant women in the Raine Study were assayed for BPA and phthalate metabolites. The children of these women were followed up at 5, 13 and 22 years where spirometry and respiratory questionnaires were conducted to determine asthma and allergy status. Lung function trajectories were derived from longitudinal spirometry measurements. Multinomial logistic regression and weighted quantile sum regression was used to test associations of individual and chemical mixtures with asthma phenotypes and lung function trajectories.

Results

Effects of prenatal BPA and phthalates on asthma phenotypes were seen in male offspring, where BPA was associated with increased risk for persistent asthma, while mono-iso-butyl phthalate and mono-iso-decyl phthalate was associated with increased risk for adult asthma. Prenatal BPA had no effect on lung function trajectories, but prenatal phthalate exposure was associated with improved lung function.

Conclusion

Prenatal BPA exposure was associated with increased likelihood of persistent asthma in males, while prenatal phthalate exposure was associated with increased likelihood of adult asthma in males. Results suggest that prenatal exposure to prenatal BPA and phthalates affect asthma risk, particularly in males, however lung function was not adversely affected.  相似文献   

19.

Background and objective

No previous studies have examined differences in spirometry measurements among ethnic populations in China, and factors which may influence ethnic differences are unclear. Our study aimed to investigate whether forced expiratory volume in 1 s (FEV1) and forced vital capacity (FVC) differ among Han Chinese and other ethnic minorities in China.

Methods

We recruited 7137 individuals aged 35–70 years from four areas of China inhabited by ethnic minority groups between 2007 and 2009. We conducted spirometry tests for all available participants, and compared FEV1 and FVC among Uygur, Hui, Mongolian, Dai and Han Chinese ethnicities, using nonlinear multiplicative regression models.

Results

A total of 2005 healthy never‐smokers were enrolled in the analysis. For all ethnicities, spirometry values increased with height and decreased with age; FEV1 and FVC were consistently higher in males than in females. Compared with Han Chinese, FEV1 was 4.42% (95% CI: 2.11–6.78%) higher in Mongolians, 4.08% (95% CI: 1.33–6.76%) lower in Uygurs, 4.39% (95% CI: 1.33–7.35%) lower in Hui people and 4.72% (95% CI: 1.80–7.55%) lower in Dai people, after adjusted for potential confounders including height, age, sex and place of residence. We observed similar differences for FVC.

Conclusions

We detected significant differences in spirometry measurements among ethnic populations in China. Such differences cannot be fully explained by demographic, anthropometric or socioeconomic factors, but may also be attributed to genetic background as well as indoor and outdoor environmental exposures that need further investigation.
  相似文献   

20.
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司    京ICP备09084417号-23

京公网安备 11010802026262号