首页 | 官方网站   微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 131 毫秒
1.
In a midstory isolated building, the isolation system is incorporated into the midstory rather than the base of the building. Because of the flexibility of the substructure below the isolation system in a midstory isolated building, the contribution of higher modes to the seismic responses of the midstory isolated structure may not be negligible, especially when the coupling of higher modes exists. To investigate this modal coupling effect, a simplified three‐lumped‐mass structural model of the midstory isolated building is assumed in this study. Through the equivalent linear analysis and shaking table tests, it is found that the coupling of higher modes may lead to enlarged acceleration responses at the super‐floor and superstructure above the isolation layer. Accordingly, a simple method to prevent the midstory isolation design from the coupling of higher modes attributed to the improper design of the substructure and superstructure is proposed in this paper. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

2.
A new seismic design manner, namely building mass damper (BMD), which is inspired from a combination of mid‐story isolation and tuned mass damper design concepts, recently attracts immense attention. It is mainly because that the use of partial structural mass of the building as an energy absorber in the BMD design can overcome the drawback of limited response reduction due to insufficient added tuned mass in the conventional tuned mass damper design. In this study, an optimum BMD (OBMD) design approach, namely optimum dynamic characteristic control approach, based on a simplified 3‐lumped‐mass structure model is proposed to seismically protect both the superstructure (or tuned mass) and the substructure (or primary structure), respectively, above and below the control layer. A series of sensitivity analyses and experimental studies on different parameters, including mass, frequency, and damping ratios, of a building model designed with a BMD system were conducted. The test results verify the practical feasibility of the BMD concept as well as the effectiveness of the proposed OBMD design. Furthermore, by comparing with the numerical results of a mid‐story isolated counterpart, it is demonstrated that the proposed OBMD design can have a comparable and even better control performance.  相似文献   

3.
A damage detection algorithm of structural health monitoring systems for base‐isolated buildings is proposed. The algorithm consists of the multiple‐input multiple‐output subspace identification method and the complex modal analysis. The algorithm is applicable to linear and non‐linear systems. The story stiffness and damping as damage indices of a shear structure are identified by the algorithm. The algorithm is further tuned for base‐isolated buildings considering their unique dynamic characteristics by simplifying the systems to single‐degree‐of‐freedom systems. The isolation layer and the superstructure of a base‐isolated building are treated as separate substructures as they are distinctly different in their dynamic properties. The effectiveness of the algorithm is evaluated through the numerical analysis and experiment. Finally, the algorithm is applied to the existing 7‐story base‐isolated building that is equipped with an Internet‐based monitoring system. Copyright © 2004 John Wiley & Sons, Ltd.  相似文献   

4.
The aim of this work is to propose seismic reliability‐based relationships between the strength reduction factors and the displacement ductility demand of nonlinear structural systems equipped with friction pendulum isolators (FPS) depending on the structural properties. The isolated structures are described by employing an equivalent 2dof model characterized by a perfectly elastoplastic rule to account for the inelastic response of the superstructure, whereas, the FPS behavior is described by a velocity‐dependent model. An extensive parametric study is carried out encompassing a wide range of elastic and inelastic building properties, different seismic intensity levels and considering the friction coefficient as a random variable. Defined a set of natural seismic records and scaled to the seismic intensity corresponding to life safety limit state for L'Aquila site (Italy) according to NTC08, the inelastic characteristics of the superstructures are designed as the ratio between the average elastic responses and increasing strength reduction factors. Incremental dynamic analyses (IDAs) are developed to evaluate the seismic fragility curves of both the inelastic superstructure and the isolation level assuming different values of the corresponding limit states. Integrating the fragility curves with the seismic hazard curves related to L'Aquila site (Italy), the reliability curves of the equivalent inelastic base‐isolated structural systems, with a design life of 50 years, are derived proposing seismic reliability‐based regression expressions between the displacement ductility demand and the strength reduction factors for the superstructure as well as seismic reliability‐based design (SRBD) abacuses useful to define the FPS properties. Copyright © 2016 John Wiley & Sons, Ltd.  相似文献   

5.
In this study, the multi‐intensity seismic response of code‐designed conventional and base‐isolated steel frame buildings is evaluated using nonlinear response history analysis. The results of hazard and structural response analysis for three‐story braced‐frame buildings are presented in this paper. Three‐dimensional models for both buildings are created and seismic response is assessed for three scenario earthquakes. The response history analysis results indicate that the design objectives are met and the performance of the isolated building is superior to the conventional building in the design event. For the Maximum Considered Earthquake, isolation leads to reductions in story drifts and floor accelerations relative to the conventional building. However, the extremely high displacement demands of the isolation system could not be accommodated under normal circumstances, and creative approaches should be developed to control displacements in the MCE. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

6.
The seismic design of multi‐story buildings asymmetric in plan yet regular in elevation and stiffened with ductile RC structural walls is addressed. A realistic modeling of the non‐linear ductile behavior of the RC walls is considered in combination with the characteristics of the dynamic torsional response of asymmetric buildings. Design criteria such as the determination of the system ductility, taking into account the location and ductility demand of the RC walls, the story‐drift demand at the softer (most displaced) edge of the building under the design earthquake, the allowable ductility (ultimate limit state) and the allowable story‐drift (performance goals) are discussed. The definition of an eccentricity of the earthquake‐equivalent lateral force is proposed and used to determine the effective displacement profile of the building yet not the strength distribution under the design earthquake. Furthermore, an appropriate procedure is proposed to calculate the fundamental frequency and the earthquake‐equivalent lateral force. A new deformation‐based seismic design method taking into account the characteristics of the dynamic torsional response, the ductility of the RC walls, the system ductility and the story‐drift at the softer (most displaced) edge of the building is presented and illustrated with an example of seismic design of a multi‐story asymmetric RC wall building. Copyright © 2005 John Wiley & Sons, Ltd.  相似文献   

7.
Usually, buildings with seismic isolation are designed to comply with an operational building performance level after strong earthquakes. This approach, however, may limit the use of seismic isolation for the seismic rehabilitation of existing buildings with low lateral strength or substandard details, because it often requires invasive strengthening measures in the superstructure or the use of expensive custom‐made devices. In this paper, an alternative approach for the seismic rehabilitation of existing buildings with seismic isolation, based on the acceptance of limited plastic deformations in the superstructure under strong earthquakes, is proposed and then applied to a real case study, represented by a four‐storey RC frame building. Nonlinear response‐time histories analyses of an accurate model of the case‐study building are carried out to evaluate the seismic performances of the structure, comparing different rehabilitation strategies with and without seismic isolation. Initial costs of the intervention and possible (future) repair costs are then estimated. Based on the results of this study, values of the behavior factor (i.e. response modification factor) higher than those adopted in the current codes for base‐isolated buildings are tentatively proposed. Copyright © 2015 John Wiley & Sons, Ltd.  相似文献   

8.
While isolation can provide significantly enhanced performance compared to fixed‐base counter parts in design level or even maximum considered level earthquakes, there is still uncertainty over the performance of isolation systems in extreme events. Researchers have looked at component level stability of rubber bearings and on the effect of moat impact on behavior of structures isolated on general bilinear isolators. However, testing of triple friction pendulum (TFP) sliding bearings has not been done dynamically or incorporated into a building system. Here, one‐third scale laboratory tests were conducted to on a 2‐story 2‐bay TFP‐isolated structure. Input motions were increasingly scaled until failure occurred at the isolation level. As the superstructure was designed with a yield force equivalent to the force of the bearing just at their ultimate displacement capacity, there was minimal yielding. A numerical model is presented to simulate the isolated building up to and including bearing failure. Forces transferred to the superstructure in extreme motions are examined using both experimental and numerical data. Additionally, the effect of the hardening stage of the TFP bearing is evaluated using the numerical model, finding slight benefits.  相似文献   

9.
Numerical simulations and parametric studies have been used to investigate the influence of potential poundings of seismically isolated buildings with adjacent structures on the effectiveness of seismic isolation. Poundings are assumed to occur at the isolation level between the seismically isolated building and the surrounding moat wall. After assessing some common force‐based impact models, a variation of the linear viscoelastic impact model is proposed to avoid tensile impact forces during detachment, while enabling the consideration of permanent plastic deformations at the vicinity of the impact. A large number of numerical simulations of seismically isolated buildings with different characteristics have been conducted under six earthquake excitations in order to investigate the influence of various design parameters and conditions on the peak floor accelerations and interstorey deflections during poundings. The numerical simulations demonstrate that poundings may substantially increase floor accelerations, especially t the base floor where impacts occur. Higher modes of vibration are excided during poundings, increasing the interstorey deflections, instead of retaining an almost rigid‐body motion of the superstructure, which is aimed with seismic isolation. Impact stiffness seems to affect significantly the acceleration response at the isolation level, while the displacement response is more insensitive to the variation of the impact stiffness. Finally, the results indicate that providing excessive flexibility at the isolation system to minimize the floor accelerations may lead to a building vulnerable to poundings, if the available seismic gap is limited. Copyright © 2007 John Wiley & Sons, Ltd.  相似文献   

10.
组合基础隔震在建筑工程中的应用   总被引:2,自引:1,他引:2  
隔震作为一种新的抗震技术,已广泛应用于新建和加固的建筑工程,同时,许多新型式的支座得到了开发和应用。组合基础隔震是一种新的隔震设计思想,能充分应用不同类型隔震支座的特性,有效降低上部结构地震反应。本文介绍了组合基础隔震在某一工程中的应用,工程中使用的支座包括普通橡胶隔震支座、铅芯橡胶隔震支座和弹性滑板支座三种类型,对全部使用支座进行了常规检测,结构计算采用等效线性法、能量包络法和时程反应分析等方法,计算结果表明:组合基础隔震能有效降低上部结构的反应,隔震层的变形控制在安全范围之内。  相似文献   

11.
Base‐isolation is regarded as one of the most effective methods for protecting the structural and nonstructural building elements from design level horizontal earthquake ground shaking. However, base‐isolation as currently practiced does not offer unlimited protection for these buildings, especially when the ground shaking includes a strong vertical component. The vulnerability of nonstructural systems in a base‐isolated building was made evident during recent shake table testing of a full‐scale five‐story base‐isolated steel moment frame where nonstructural system damage was observed following tests including vertical excitation. Past research efforts have attempted to achieve 3D isolation of buildings and nuclear structures by concentrating both the horizontal and vertical flexibility at the base of the building that are either quite limited or not economically viable. An approach whereby the vertical flexibility is distributed up the height of the building superstructure to passively reduce vertical acceleration demands in base‐isolated buildings is presented. The vertical flexibility is achieved by placing laterally restrained elastomeric ‘column’ bearings at one or more floor levels along the height of the building. To broadly investigate the efficacy of the vertically distributed flexibility concept and the trade‐off between mitigation and cost, a multi‐objective optimization study was conducted considering 3‐story, 9‐story, and 20‐story archetype buildings that aimed to minimize the median peak vertical floor acceleration demands and to minimize the direct cost of column bearings. Based on the results of the optimization study, a practical rule for determining the number of levels and locations of column bearings is proposed and evaluated. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

12.
Seismic pounding of base‐isolated buildings has been mostly studied in the past assuming unidirectional excitation. Therefore, in this study, the effects of seismic pounding on the response of base‐isolated reinforced concrete buildings under bidirectional excitation are investigated. For this purpose, a three‐dimensional finite element model of a code‐compliant four‐story building is considered, where a newly developed contact element that accounts for friction and is capable of simulating pounding with retaining walls at the base, is used. Nonlinear behavior of the superstructure as well as the isolation system is considered. The performance of the building is evaluated separately for far‐fault non‐pulse‐like ground motions and near‐fault pulse‐like ground motions, which are weighted scaled to represent two levels of shaking viz. the design earthquake (DE) level and the risk‐targeted maximum considered earthquake (MCER) level. Nonlinear time‐history analyses are carried out considering lower bound as well as upper bound properties of isolators. The influence of separation distance between the building and the retaining walls at the base is also investigated. It is found that if pounding is avoided, the performance of the building is satisfactory in terms of limiting structural and nonstructural damage, under DE‐level motions and MCER‐level far‐fault motions, whereas unacceptably large demands are imposed by MCER‐level near‐fault motions. In the case of seismic pounding, MCER‐level near‐fault motions are found to be detrimental, where the effect of pounding is mostly concentrated at the first story. In addition, it is determined that considering unidirectional excitation instead of bidirectional excitation for MCER‐level near‐fault motions provides highly unconservative estimates of superstructure demands. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

13.
This paper proposes an aseismic design concept in which the superstructure of a base-isolated building is divided into several segments. Each segment may comprise a few storeys and is interconnected by additional vibrational isolation systems. The dynamic characteristics of the segmental buildings are investigated. The optimum parameters of the vibration isolation systems are determined by minimizing the mean square acceleration response. The seismic response of a typical segmental building subjected to the N—S component of the 1940 El Centro earthquake input is evaluated and compared with the responses of the corresponding fixed-base and conventional base-isolated buildings. The comparisons show that, when the superstructure is segmented, while the acceleration response in the superstructure remains as small as that in the conventional base-isolated building, the displacement across the base isolation system at foundation level is substantially reduced.  相似文献   

14.
The Friction Pendulum System (FPS) isolator is commonly used as a base isolation system in buildings. In this paper, a new tunable FPS (TFPS) isolator is proposed and developed to act as a semi‐active control system by combining the traditional FPS and semi‐active control concept. Theoretical analysis and physical tests were carried out to investigate the behavior of the proposed TFPS isolator. The experimental and theoretical results were in good agreement, both suggesting that the friction force of the TFPS isolator can be tuned to achieve seismic isolation of the structure. A series of numerical simulations of a base‐isolated structure equipped with the proposed TFPS isolator and subjected to earthquake ground motions were also conducted. In the analyses, the linear quadratic regulator (LQR) method was adopted to control the friction force of the proposed TFPS, and the applicability and effectiveness of the TFPS in controlling the structure's seismic responses were investigated. The simulation results showed that the TFPS can reduce the displacement of the isolation layer without significantly increasing the floor acceleration and inter‐story displacement of the superstructure, confirming that the TFPS can effectively control a base‐isolated structure under earthquake ground motions.  相似文献   

15.
Effectiveness of a new semiactive independently variable stiffness (SAIVS) device in reducing seismic response of sliding base isolated buildings is evaluated analytically and experimentally. Through analytical and experimental study of force—displacement behaviour of the SAIVS device, it is shown that the device can vary stiffness continuously and smoothly between minimum and maximum stiffness. Passive sliding base isolation systems reduce interstorey drifts and superstructure accelerations, but with increased base displacements, which is undesirable, under large velocity near fault pulse type earthquakes. It is a common practice to incorporate non‐linear passive dampers into the isolation system to reduce bearing displacements. Incorporation of passive dampers, however, may result in increased superstructure accelerations and drifts; while, properly designed passive dampers can be beneficial. A viable alternative is to use semiactive variable stiffness systems, which can vary the period of the sliding base isolated buildings in real time, to simultaneously reduce bearing displacements and superstructure responses further than the passive systems, which deserves investigation. This study investigates the performance of a 1:5 scaled smart sliding base isolated building model equipped with the SAIVS device analytically and experimentally, under near fault earthquakes, by developing a new moving average non‐linear tangential stiffness control algorithm for control of the SAIVS device. The SAIVS device reduces bearing displacements further than the passive cases, while maintaining isolation level forces and superstructure responses at the same level as the passive minimum stiffness case, indicating the significant potential of the SAIVS system. Copyright © 2005 John Wiley & Sons, Ltd.  相似文献   

16.
Modern highway bridges in Illinois are often installed with economical elastomeric bearings that allow for thermal movement of the superstructure, and steel fixed bearings and transverse retainers that prevent excessive movement from service‐level loadings. In the event of an earthquake, the bearing system has the potential to provide a quasi‐isolated response where failure of sacrificial elements and sliding of the bearings can cause a period elongation and reduce or cap the force demands on the substructure. A computational model that has been calibrated for the expected nonlinear behaviors is used to carry out a parametric study to evaluate quasi‐isolated bridge behavior. The study investigates different superstructure types, substructure types, substructure heights, foundation types, and elastomeric bearing types. Overall, only a few bridge variants were noted to unseat for design‐level seismic input in the New Madrid Seismic Zone, indicating that most structures in Illinois would not experience severe damage during their typical design life. However, Type II bearing systems, which consist of an elastomeric bearing and a flat PTFE slider, would in some cases result in critical damage from unseating at moderate and high seismic input. The sequence of damage for many bridge cases indicates yielding of piers at low‐level seismic input. This is caused by the high strength of the fixed bearing element, which justifies further calibration of the quasi‐isolation design approach. Finally, the type of ground motion, pier height, and bearing type were noted to have significant influence on the global bridge response. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

17.
A comprehensive parametric study on the inelastic seismic response of seismically isolated RC frame buildings, designed for gravity loads only, is presented. Four building prototypes, with 23 m × 10 m floor plan dimensions and number of storeys ranging from 2 to 8, are considered. All the buildings present internal resistant frames in one direction only, identified as the strong direction of the building. In the orthogonal weak direction, the buildings present outer resistant frames only, with infilled masonry panels. This structural configuration is typical of many existing RC buildings, realized in Italy and other European countries in the 60s and 70s. The parametric study is based on the results of extensive nonlinear response‐time history analyses of 2‐DOF systems, using a set of seven artificial and natural seismic ground motions. In the parametric study, buildings with strength ratio (Fy/W) ranging from 0.03 to 0.15 and post‐yield stiffness ratio ranging from 0% to 6% are examined. Three different types of isolation systems are considered, that is, high damping rubber bearings, lead rubber bearings and friction pendulum bearings. The isolation systems have been designed accepting the occurrence of plastic hinges in the superstructure during the design earthquake. The nonlinear response‐time history analyses results show that structures with seismic isolation experience fewer inelastic cycles compared with fixed‐base structures. As a consequence, although limited plastic deformations can be accepted, the collapse limit state of seismically isolated structures should be based on the lateral capacity of the superstructure without significant reliance on its inherent hysteretic damping or ductility capacity. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

18.
This paper investigates numerically the seismic response of six seismically base‐isolated (BI) 20‐story reinforced concrete buildings and compares their response to that of a fixed‐base (FB) building with a similar structural system above ground. Located in Berkeley, California, 2 km from the Hayward fault, the buildings are designed with a core wall that provides most of the lateral force resistance above ground. For the BI buildings, the following are investigated: two isolation systems (both implemented below a three‐story basement), isolation periods equal to 4, 5, and 6 s, and two levels of flexural strength of the wall. The first isolation system combines tension‐resistant friction pendulum bearings and nonlinear fluid viscous dampers (NFVDs); the second combines low‐friction tension‐resistant crosslinear bearings, lead‐rubber bearings, and NFVDs. The designs of all buildings satisfy ASCE 7‐10 requirements, except that one component of horizontal excitation, is used in the 2D nonlinear response history analysis. Analysis is performed for a set of ground motions scaled to the design earthquake and to the maximum considered earthquake (MCE). At both the design earthquake and the MCE, the FB building develops large inelastic deformations and shear forces in the wall and large floor accelerations. At the MCE, four of the BI buildings experience nominally elastic response of the wall, with floor accelerations and shear forces being 0.25 to 0.55 times those experienced by the FB building. The response of the FB and four of the BI buildings to four unscaled historical pulse‐like near‐fault ground motions is also studied. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

19.
大底盘多塔楼结构的混合隔震控制   总被引:2,自引:0,他引:2  
结合某实际工程,针对大底盘多塔楼结构提出混合隔震的控制策略,即对大底盘上的一栋或多栋塔楼采用隔震技术,并在隔震层附设一定数量的被动、主动或半主动的减震控制装置。建立了这种大底盘多塔楼结构混合隔震控制体系的运动方程,方程中各塔楼与下部结构及隔震层之间的刚度解耦,并考虑了隔震层的非线性。研究中比较了被动非线性粘滞阻尼器,半主动变孔隙阻尼器与理想主动控制时的减震控制效果。结果表明,这种混合隔震体系可以有效地减小上部塔楼与下部结构的地震反应,提高大底盘多塔楼结构的抗震安全性,取得明显的经济和社会效益。半主动变孔隙阻尼器可以极好地追踪理想主动控制力,取得与理想主动控制相近的减震控制效果。被动非线性粘滞阻尼器也能取得较好的减震效果,且易于维护,经济性较好,从工程应用的角度来看更为现实可行,具有较好的应用推广价值。  相似文献   

20.
Hybrid simulations of a full‐scale soft‐story woodframe building specimen with various retrofits were carried out as part of the Network for Earthquake Engineering Simulation Research project – NEES‐Soft: seismic risk reduction for soft‐story woodframe buildings. The test structure in the hybrid simulation was a three‐story woodframe building that was divided into a numerical substructure of the first story with various retrofits and a full‐scale physical substructure of the upper two stories. Four long‐stroke actuators, two at the second floor and two at the roof diaphragm, were attached to the physical substructure to impose the simulated seismic responses including both translation and in‐plane rotation. Challenges associated with this first implementation of a full‐scale hybrid simulation on a woodframe building were identified. This paper presents the development and validation of a scalable and robust hybrid simulation controller for efficient test site deployment. The development consisted of three incremental validation phases ranging from small‐scale, mid‐scale, to full‐scale tests conducted at three laboratories. Experimental setup, procedure, and results of each phase of the controller development are discussed, demonstrating the effectiveness and efficiency of the incremental controller development approach for large‐scale hybrid simulation programs with complex test setup. Copyright © 2016 John Wiley & Sons, Ltd.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司    京ICP备09084417号-23

京公网安备 11010802026262号