首页 | 官方网站   微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
粘结MoS2固体润滑涂层的转动微动磨损特性   总被引:2,自引:0,他引:2  
采用粘结法在LZ50钢表面制备MoS2固体润滑涂层,研究MoS2涂层及LZ50钢基体在干态不同角位移幅值下的转动微动磨损行为。在分析转动微动动力学特性的同时,结合光学显微镜、扫描电子显微镜、电子能谱仪以及轮廓仪对磨痕形貌进行微观分析。结果表明:涂层和基体的转动微动运行区域仅呈现部分滑移区(Partial slip regime,PSR)和滑移区(Slip regime,SR),未观察到混合区。涂层改变基体的微动运行区域,使得PSR缩小,SR运行区域向小角位移幅值方向移动。由于MoS2涂层的固体润滑作用,涂层的摩擦因数在整个试验过程都明显低于基体。在PSR,涂层损伤轻微;在SR,涂层的转动微动磨损机制主要表现为剥层和摩擦氧化。研究表明粘结MoS2固体润滑涂层具有明显的防护作用,显著降低LZ50钢的转动微动磨损。  相似文献   

2.
The rotational fretting wear behaviors of the bonded MoS2 solid lubricant coating and its substrate steel were comparatively studied under varied angular displacement amplitudes, constant normal load, and rotational speed. Dynamic analysis in combination with microscopic examinations was performed through SEM, EDX, XPS, optical microscope, and surface profilometer. The experimental results showed MoS2 changed the fretting running regimes of substrate. The friction coefficients of MoS2 were lower than those of the substrate. For MoS2, the damage in partial slip regime was very slight. The damage mechanism of the coating in slip regime was main abrasive wear, delamination, and tribo-oxidation.  相似文献   

3.
Bonded MoS2 solid lubricant coatings are widely used in tribology for their friction-reducing and antiwear properties. However, such coatings have been rarely investigated in complex fretting conditions, such as dual-rotary fretting (DRF). DRF is a complex fretting wear mode that combines torsional fretting with rotational fretting. In this work, the antiwear properties of bonded MoS2 solid lubricant coating under dual-rotary fretting conditions were studied. Results indicated that the MoS2 coating had better friction-reducing and antiwear properties than the substrate for alleviating DRF wear. The coating can greatly influence the fretting regimes and reduce the coefficient of friction. Furthermore, the service life of the coating was strongly dependent on the competition of the two fretting components and was reduced as the rotational fretting component increased.  相似文献   

4.
Rotational fretting which exist in many engineering applications has incurred enormous economic loss. Thus, accessible methods are urgently needed to alleviate or eliminate damage by rotational fretting. Surface engineering is an effective approach that is successfully adopted to enhance the ability of components to resist the fretting damage. In this paper, using a high-velocity oxygen fuel sprayed(HVOF) technique WC-17 Co coating is deposited on an LZ50 steel surface to study its properties through Vickers hardness testing, scanning electric microscope(SEM), energy dispersive X-ray spectroscopy(EDX), and X-ray diffractrometry(XRD). Rotational fretting wear tests are conducted under normal load varied from 10 N to 50 N, and angular displacement amplitudes vary from 0.125° to 1°. Wear scars are examined using SEM, EDX, optical microscopy(OM), and surface topography. The experimental results reveal that the WC-17 Co coating adjusted the boundary between the partial slip regime(PSR) and the slip regime(SR) to the direction of smaller amplitude displacement. As a result, the coefficients of friction are consistently lower than the substrate's coefficients of friction both in the PSR and SR. The damage to the coating in the PSR is very slight. In the SR, the coating exhibits higher debris removal efficiency and load-carrying capacity. The bulge is not found for the coating due to the coating's higher hardness to restrain plastic flow. This research could provide experimental bases for promoting industrial application of WC-17 Co coating in prevention of rotational fretting wear.  相似文献   

5.
On the mechanisms of various fretting wear modes   总被引:1,自引:0,他引:1  
According to relative motion directions for a ball-on-flat contact, there are four fundamental fretting wear modes, e.g., tangential, radial, torsional and rotational modes. In this paper, the mechanisms of these four fundamental fretting wear modes, particularly for the later three modes, have been reviewed from results obtained by the authors in combination with results from literature. Some general features have been reported. Differences both in running and degradation behavior have been discussed in detail. Results showed that some similar laws for three fretting regimes (partial slip regime, mixed regime and slip regime), fretting maps (running condition fretting map and material response fretting map), wear and cracking mechanisms obtained from the classic mode (i.e. tangential fretting) were also identified and useful to characterize the other modes. Nevertheless, the occurrence of relative slip for the radial fretting, the formation of mixed regime for the torsional fretting, the evolution of surface morphology for the rotational fretting were quite different compared to that of the classical fretting mode.  相似文献   

6.
Abstract

The tension–tension fretting fatigue tests of steel wires were performed on a self-made fretting fatigue test equipment under contact loads ranging from 40 to 70 N and a strain ratio of 0·8. The results showed that when the contact load increased, the fretting regime of steel wires transformed from gross slip regime to mixed fretting regime. The fretting fatigue life in the mixed fretting regime was significantly lower than that in the gross slip regime. The main fretting wear mechanisms in the gross slip regime, where there were serious fretting damage and a lot of wear debris, were abrasive wear and fatigue wear. Microcracks were observed in the fretting scar of the mixed fretting regime, and the main fretting wear mechanisms were adhesive and fatigue wears. The fretting wear scar was the fatigue source region, and the fatigue fracture surface could be divided into three regions.  相似文献   

7.
The fretting wear behavior of the nuclear power material Incoloy 800 was investigated in this study. A PLINT high-temperature fretting tester was used on an Incoloy 800 cylinder against a 304SS cylinder at vertical cross contact under different temperatures (25, 300, and 400°C). During testing, a normal load of 80 N was applied, and the displacement amplitudes ranged from 2 to 40 µm. The fretting wear mechanism at high temperatures and the kinetic character of the materials of the Incoloy 800 steam generator tube were analyzed. Results showed that the fretting running regimes varied little with ncreasing temperature, and some microcracks were observed in both the mixed fretting regime (MFR) and the partial slip regime (PSR) at high temperatures. Slight abrasive wear and microcracks were the main wear mechanisms of the Incoloy 800 alloy in PSR, whereas those in the MFR and the gross slip regime were oxidative wear, abrasive wear, and delamination.  相似文献   

8.
Fretting wear tests were performed on the self-made fretting wear rig to investigate fretting wear behaviors of steel wires under friction-increasing grease conditions. The results demonstrated that the fretting regimes were dependent on displacement amplitudes and normal loads. The friction coefficient exhibited different variation trends in different fretting regimes. Friction-increasing grease changed the fretting running behavior and had a very good wear resistance for steel wires. Wear was slight in partial slip regime. Mixed regime was characterized by plastic deformation, fatigue cracks and abrasive wear. Slip regime presented main damage mechanisms of abrasive wear, fatigue wear and oxidation.  相似文献   

9.
Fretting damage was one of the most important reasons for the failure of the railway axle. Fretting wear (tangential fretting mode) tests of a railway axle steel (LZ50 steel) flats against 52 100 steel balls were carried out under different normal loads and displacement amplitudes on a hydraulic fretting wear rig. Dynamic analyses in combination with microscopic examinations have been performed. The experimental results showed that the fretting regimes of the LZ50 steel were strongly dependent upon the imposed normal loads and displacement amplitudes. The Ft/Fn curves exhibited different variation trends in different fretting running regimes. The fretting scars presented slight damage in partial slip regime. In mixed fretting regime, the trace of the plowing and plastic deformation flow can be observed on the fretting scars. The wear mechanism during this regime was the combination of the abrasive wear, oxidative wear and delamination accompanied with obvious plastic deformation. The detachment of particles and plowing traces were the main phenomena in slip regime. And, thicker debris layer covered the contact zone of the scar. The severe degradation in slip regime presented the main wear mechanisms of abrasive wear, oxidative wear and delamination.  相似文献   

10.
An experimental study torsional fretting behaviors of LZ50 steel   总被引:1,自引:0,他引:1  
Four simple fretting modes are defined according to relative motion: tangential, radial, rotational, and torsional fretting. This paper presents a new test rig that was developed from a low-speed reciprocating rotary system to show torsional fretting wear under ball-on-flat contact. Torsional fretting behavior was investigated for LZ50 steel flats against AISI52100 steel balls under various angular displacement amplitudes and normal loads. The friction torques and dissipation energy were analyzed in detail. Two types of Tθ curves in the shape of quasi-parallelograms and ellipticals were found that correspond to gross and partial slips, respectively. The experimental results showed that the dynamic behavior and damage processes depend strongly on the normal loads, angular displacement amplitudes, and cycles. In this paper, the debris and oxidation behaviors and detachment of particles in partial and gross slip regimes are also discussed. Debris and oxidation are shown to have important roles during the torsional fretting processes. The wear mechanism of torsional fretting was a combination of abrasive and oxidative wear and delamination before third-body bed formation. The mechanism was then transformed into third-body wear after a great amount of debris formed.  相似文献   

11.
Detonation gun (D-gun) spraying is one of the most promising spraying techniques for producing wear-resistance coatings. A thick layer (about 0.3 mm thickness) of WC-25Co with high hardness was covered on Ti-Al-Zr titanium alloy by D-gun spraying and the fretting wear behavior of WC-25Co coatings was studied experimentally on a high precision hydraulic fretting wear test rig. An experimental layout was designed to perform fretting wear tests at elevated temperatures from room temperature (25 °C) to 400 °C in ambient air. In the tests, a sphere (Si3N4 ceramic ball) was designed to rub against a plane (Ti-Al-Zr titanium alloy with or without WC-25Co coatings). It was found that the fretting running regimes of WC-25Co coatings were obviously different from those of Ti-Al-Zr titanium alloy. The mixed fretting regime disappeared in WC-25Co coatings, and the boundaries in the running condition fretting map (RCFM) showed hardly any change as temperature increased. The worn scars were examined using a laser confocal scanning microscope (LCSM), scanning electron microscope (SEM), energy dispersive X-ray spectroscopy (EDS) and X-ray photoelectron spectroscopy (XPS). The results showed that the coefficients of friction (COF) of WC-25Co coatings at elevated temperatures were nearly constant in the partial slip regime and very low in the steady state. The fretting damage of the coatings was very slight. In the slip regime, the WC-25Co coatings exhibited a good wear resistance, and the wear volume of the coatings obviously decreased with increasing tested temperature. The fretting wear mechanisms of WC-25Co coatings were delamination, abrasive wear and oxidation wear at elevated temperature. The oxide debris layer formed at higher temperature was denser and thicker on top of WC-25Co coatings, thus providing more surface protection against fretting wear, which played an important role in the low fretting wear of the coatings.  相似文献   

12.
Jie Li  Xiaohui Tu  Wei Li 《摩擦学汇刊》2019,62(2):198-206
The investigations on fretting wear behaviors of nickel based alloy in NaCl solution and atmosphere indicated that wear mechanism and regional transformation from partial slip regime (PSR) to the mixed regime (MR) are significantly affected by NaCl solution. The crevice corrosion induced by synergy of chloride ion and deformed asperities caused wear mechanism changed from adhesive and oxidation wear (PSR in atmosphere) to abrasive and oxidation wear (PSR in NaCl solution) and to oxidation and delamination wear (MR in NaCl solution), meanwhile accelerated the regional transformation from PSR to MR. However, the annular fatigue crack was almost unaffected by NaCl solution, which propagated along the direction of 40-50° to surface in the mode of transgranular and intergranular in all conditions.  相似文献   

13.
The introduction of surface engineering is expected to be an effective strategy against fretting damage. A large number of studies show that the low gas multi-component (such as carbon, nitrogen, sulphur and oxygen, etc) thermo-chemical treatment(LTGMTT) can overcome the brittleness of nitriding process, and upgrade the surface hardness and improve the wear resistance and fatigue properties of the work-pieces significantly. However, there are few reports on the anti-fretting properties of the LTGMTT modified layer up to now, which limits the applications of fretting. So this paper discusses the fretting wear behavior of modified layer on the surface of LZ50 (0.48%C) steel prepared by low temperature gas multi-component thermo-chemical treatment (LTGMTT) technology. The fretting wear tests of the modified layer flat specimens and its substrate (LZ50 steel) against 52100 steel balls with diameter of 40 mm are carried out under normal load of 150 N and displacement amplitudes varied from 2 μm to 40 μm. Characterization of the modified layer and dynamic analyses in combination with microscopic examinations were performed through the means of scanning electron microscope(SEM), optical microscope(OM), X-ray diffraction(XRD) and surface profilometer. The experimental results showed that the modified layer with a total thickness of 60 μm was consisted of three parts, i.e., loose layer, compound layer and diffusion layer. Compared with the substrate, the range of the mixed fretting regime(MFR) of the LTGMTT modified layer diminished, and the slip regime(SR) of the modified layer shifted to the direction of smaller displacement amplitude. The coefficient of friction(COF) of the modified layer was lower than that of the substrate in the initial stage. For the modified layer, the damage in partial slip regime(PSR) was very slight. The fretting wear mechanism of the modified layer both in MFR and SR was abrasive wear and delamination. The modified layer presented better wear resistance than the substrate in PSR and MFR; however, in SR, the wear resistance of the modified layer decreased with the increase of the displacement amplitudes. The experimental results can provide some experimental bases for promoting industrial application of LTGMTT modified layer in anti-fretting wear.  相似文献   

14.
采用面接触扭动微动形式,以动力定位系统可调距螺旋桨桨-毂轴承摩擦副材料(CuNiAl-42CrMo4)为对象,以不同的角位移幅值模拟海水波动影响下的微动磨损行为,并结合扫描电子显微镜和超景深三维显微镜对磨痕形貌进行分析,探究桨-毂轴承摩擦副材料扭动微动磨损规律。结果表明,随着角位移幅值的增加,扭动微动依次运行于部分滑移区、混合区、滑移区,摩擦因数减小,同时磨损量增加,微动损伤中剥层机制所占的比例逐渐增加,且由于疲劳裂纹扩展的不利影响,实际运行过程中要尽量避开混合区。  相似文献   

15.
The influence of oil lubrication on the fretting wear behaviors of 304 stainless steel flat specimens under different fretting strokes and normal loads has been investigated. The results proved that fretting regimes and fretting wear behaviors of 304 stainless steels were closely related to the fretting conditions. In general, the increase in normal load could increase wear damage during sliding wear. However, according to the results, a significant reduction in wear volume and increase in friction coefficient was observed when the normal load was increased to critical values of 40 and 50 N at a fretting stroke of 50 μm due to the transformation of the fretting regime from a gross slip regime to partial slip regime. Only when the fretting stroke further increased to a higher value of 70 μm at 50 N, fretting could enter the gross slip regime. There was low wear volume and a high friction coefficient when fretting was in the partial slip regime, because oil penetration was poor. The wear mechanisms were fatigue damage and plastic deformation. There was high wear volume and low friction coefficient when fretting was in the gross slip regime, because the oil could penetrate into the contact surfaces. Unlike the wear mechanisms in the partial slip regime, fretting damage of 304 stainless steels was mainly caused by abrasive wear in the gross slip regime.  相似文献   

16.
The fretting test was carried out using an SRV IV fretting test rig in order to investigate the fretting wear behavior and mechanism in Inconel 600 alloy at room temperature. The materials were rolled to different reductions before the test. The effect of cold rolling on the friction coefficient and wear volume was subsequently investigated. The surface and cross-sectional morphologies of the wear scar were studied by scanning electron microscopy (SEM), laser scanning confocal microscopy (LSCM), and electron back-scattering diffraction (EBSD). The results indicated that the cold rolling had a different effect on wear behavior in different slip regimes. In the stick regime, cold rolling strongly decreased the wear volume, although it did not affect the friction coefficient. The 25% rolled specimen had the minimum wear volume. The mechanisms of as-received and 50% rolled specimens were delamination and oxidation wear, whereas for the 25% rolled specimen, cracking was the main wear mechanism. In the gross slip regime, cold rolling had little effect on the friction coefficient or wear volume. The fretting wear process gave rise to a decrease in the Σ3 grain boundary, an increase in local misorientation, and a change in the crystal orientation.  相似文献   

17.
This paper describes fretting wear behaviour of low friction CoCrAlY-MoS2 coatings on titanium alloy substrates in terms of dissipated energy and friction coefficient. Experimental characterisation was achieved by measuring the friction coefficient vs fretting cycles, or slid distance. Test results were analysed using exponential evolution functions for fretting damage. Dissipated energy was derived, and predicted and measured values compared. Quantitative evaluation of the fretting damage was performed by measuring substrate area emerged. Results show that the friction coefficient evolution rate of CoCrAlY-MoS2 coating correlates well with the damaged area fraction and the accumulated dissipated energy.  相似文献   

18.
Fretting wear and fretting fatigue are two commonly observed material damages when two contacting bodies with a clamping load are under the oscillatory motion. In this study, fretting wear damage of Cu–Al coating on titanium alloy, Ti–6Al–4V substrate was investigated using the dissipated energy approach. Fretting tests were conducted with either no fatigue load or the maximum fatigue load of 300 MPa and stress ratio of 0.1 on the substrate (specimen). In order to investigate the effect of contact load and contact size, different pad sizes and contact loads were used in the tests. Accumulated dissipated energy versus wear volume data showed a linear relationship regardless of fatigue loading condition on specimen with the smaller pad size. However, two separate linear relationships were observed based on the fatigue loading condition with the larger pad size, such that a relatively more dissipated energy was required for a certain amount of wear with fatigue load on the specimen. The linear relationship between the accumulated dissipated energy and wear volume for both pad sizes extended from partial to gross slip regimes and was not affected by the applied contact load. Further, fretting tests with and without fatigue load resulted in different shapes of fretting loops when the larger pad size was used.  相似文献   

19.
聚四氟乙烯基粘结固体润滑涂层微动磨损性能研究   总被引:4,自引:0,他引:4  
在不同位移幅值与载荷条件下研究了酚醛环氧粘结聚四氟乙烯(PTFE)基固体润滑涂层的微动磨损特性,并利用扫描电子显微镜、表面轮廓仪和傅里叶表面红外仪等对涂层磨斑进行分析。结果表明,粘结PTFE基涂层具有良好的抗微动损伤性能,随循环次数的变化只存在部分滑移区和滑移区,部分滑移区的损伤轻微,滑移区的损伤强烈依赖于栽荷,其损伤与PTFE分子链在往复交变载荷作用下的疲劳断裂相关。  相似文献   

20.
C.H. Hager Jr.  J.H. Sanders  S. Sharma 《Wear》2008,265(3-4):439-451
Plasma-sprayed Al–bronze or CuNiIn coatings are often applied to protect against fretting wear and extend the operational life of Ti-alloy compressor blades in turbine engines. In order to develop a fundamental understanding of how these coating systems perform under gross slip fretting conditions, bench level fretting wear tests were conducted at room temperature to simulate cold engine startup. Alternative coatings such as plasma-sprayed molybdenum and nickel were also evaluated because of their potential for reducing fretting wear under certain simulated engine conditions. The combination of scanning electron microscopy (SEM), surface profilometry, surface chemistry (EDS), and friction analysis were used to study coating performance and evaluate the interfacial wear mechanisms. In this study, it was determined that all coatings caused significant damage to the mating Ti6Al4V surfaces and that the wear mechanisms were all similar to those of the uncoated baseline case.  相似文献   