首页 | 官方网站   微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
Experiments of diabatic two-phase pressure drops in flow boiling were conducted in four horizontal flattened smooth copper tubes with two different heights of 2 and 3 mm. The equivalent diameters of the flat tubes are 8.6, 7.17, 6.25, and 5.3 mm. The working fluids are R22 and R410A, respectively. The test conditions are: mass velocities from 150 to 500 kg/m2 s, heat fluxes from 6 to 40 kW/m2 and saturation temperature of 5 °C (reduced pressures pr are 0.12 for R22 and 0.19 for R410A). The experimental results of two-phase pressure drops are presented and analyzed. Furthermore, the predicted two-phase frictional pressure drops by the flow pattern based two-phase pressure drop model of Moreno Quibén and Thome [J. Moreno Quibén, J.R. Thome, Flow pattern based two-phase frictional pressure drop model for horizontal tubes, Part I: Diabatic and adiabatic experimental study, Int. J. Heat Fluid Flow 28 (2007) 1049–1059; J. Moreno Quibén, J.R. Thome, Flow pattern based two-phase frictional pressure drop model for horizontal tubes, Part II: New phenomenological model, Int. J. Heat Fluid Flow 28 (2007) 1060–1072] using the equivalent diameters were compared to the experimental data. The model, however, underpredicts the flattened tube two-phase frictional pressure drop data. Therefore, correction to the annular flow friction factor was proposed for the flattened tubes and now the method predicts 83.7% of the flattened tube pressure drop data within ±30%. The model is applicable to the flattened tubes in the test condition range in the present study. Extension of the model to other conditions should be verified with experimental data.  相似文献   

2.
A recently published paper by this author [S. Thyageswaran, Analysis of multi-pass evaporators using orthogonal collocation, Int. J. Refrigeration doi:10.1016/j.ijrefrig.2007.06.011 (in press)], shows that orthogonal collocation is an effective alternative to traditional integration for the thermal analysis of multi-pass evaporators. The steady rate of heat exchanged (Q) and overall pressure drop (Δp), for an R-22 based chiller having one shell and eight tube passes, were predicted using the Kattan–Thome–Favrat and the Müller-Steinhagen and Heck models for the boiling R-22. While Q was over-predicted by 0.95%, Δp was over-predicted by 20.3%. In the present work, results have been obtained using state-of-the-art, unified heat transfer and pressure drop sub-models based upon an improved flow pattern map by Wojtan et al. [L. Wojtan, T. Ursenbacher, J.R. Thome, Investigation of flow boiling in horizontal tubes, part 1: a new diabatic two-phase flow pattern map, Int. J. Heat Mass Transfer 48 (2005) 2955–2969; L. Wojtan, T. Ursenbacher, J.R. Thome, Investigation of flow boiling in horizontal tubes, part 2: development of a new heat transfer model for stratified-wavy, dryout and mist flow regimes, Int. J. Heat Mass Transfer 48 (2005) 2970–2985], and Moreno Quibén and Thome [J.M. Quibén, J.R. Thome, Flow pattern based two-phase frictional pressure drop model for horizontal tubes, part 1: diabatic and adiabatic experimental study, Int. J. Heat Fluid Flow 28 (5) (2007) 1049–1059; J.M. Quibén, J.R. Thome, Flow pattern based two-phase frictional pressure drop model for horizontal tubes, part 2: new phenomenological model, Int. J. Heat and Fluid Flow 28 (5) (2007) 1060–1072]. The new predictions for Q and Δp are 141.76 kW and 13.3 kPa, respectively, compared to their rated values of 140.67 kW and 13.789 kPa.  相似文献   

3.
An updated flow pattern map was developed for CO2 on the basis of the previous Cheng–Ribatski–Wojtan–Thome CO2 flow pattern map [1], [2] to extend the flow pattern map to a wider range of conditions. A new annular flow to dryout transition (A–D) and a new dryout to mist flow transition (D–M) were proposed here. In addition, a bubbly flow region which generally occurs at high mass velocities and low vapor qualities was added to the updated flow pattern map. The updated flow pattern map is applicable to a much wider range of conditions: tube diameters from 0.6 to 10 mm, mass velocities from 50 to 1500 kg/m2 s, heat fluxes from 1.8 to 46 kW/m2 and saturation temperatures from ?28 to +25 °C (reduced pressures from 0.21 to 0.87). The updated flow pattern map was compared to independent experimental data of flow patterns for CO2 in the literature and it predicts the flow patterns well. Then, a database of CO2 two-phase flow pressure drop results from the literature was set up and the database was compared to the leading empirical pressure drop models: the correlations by Chisholm [3], Friedel [4], Grönnerud [5] and Müller-Steinhagen and Heck [6], a modified Chisholm correlation by Yoon et al. [7] and the flow pattern based model of Moreno Quibén and Thome [8], [9], [10]. None of these models was able to predict the CO2 pressure drop data well. Therefore, a new flow pattern based phenomenological model of two-phase flow frictional pressure drop for CO2 was developed by modifying the model of Moreno Quibén and Thome using the updated flow pattern map in this study and it predicts the CO2 pressure drop database quite well overall.  相似文献   

4.
The flow pattern based flow boiling heat transfer and two-phase pressure drop models for CO2, recently developed by Cheng et al. [L. Cheng, G. Ribatski, J. Moreno Quibén, J.R. Thome, New prediction methods for CO2 evaporation inside tubes: Part I – A two-phase flow pattern map and a flow pattern based phenomenological model for two-phase flow frictional pressure drops, Int. J. Heat Mass transfer 51 (2008) 111–124; L. Cheng, G. Ribatski, J.R. Thome, New prediction methods for CO2 evaporation inside tubes: Part II – An updated general flow boiling heat transfer model based on flow patterns, Int. J. Heat Mass transfer 51 (2008) 125–135], have been used to predict the thermal performance of CO2 in a silicon multi-microchannel evaporator (67 parallel channels with a width of 0.223 mm, a height of 0.68 mm and a length of 20 mm) for cooling of a microprocessor. First, some simulation results of CO2 flow boiling heat transfer and two-phase pressure drops in microscale channels are presented. The effects of channel diameter, mass flux, saturation temperature and heat flux on flow boiling heat transfer coefficients and two-phase pressure drops are next addressed. Then, simulations of the base temperatures of the silicon multi-microchannel evaporator using R236fa and CO2 were performed for the following conditions: base heat fluxes from 20 to 100 W/cm2, a mass flux of 987.6 kg/m2s and a saturation temperature of 25 °C. These show that the base temperatures using CO2 are much lower than those using R236fa. Compared to R236fa, CO2 has much higher heat transfer coefficients and lower pressure drops in the multi-microchannel evaporator. However, the operation pressure of CO2 is much higher than that of R236fa. Based on the analysis and comparison, CO2 appears to be a promising coolant for microprocessors at low operating temperatures but also presents a great technological challenge like other new cooling technologies.  相似文献   

5.
New experimental critical heat flux results for saturated boiling conditions have been obtained for R236fa flowing in a silicon multi-microchannel heat sink composed of 67 parallel channels, 223 μm wide, 680 μm high and with 80 μm thick fins separating the channels. The microchannel length was 20 mm. The footprint critical heat fluxes measured varied from 112 to 250 W/cm2 and the wall critical heat fluxes from 21.9 to 52.2 W/cm2 for mass velocities from 276 to 992 kg/m2s. When increasing the mass velocity, the wall critical heat flux was observed to increase. The inlet saturation temperatures (20.31 ? Tsat,in ? 34.27 °C) and the inlet subcoolings (0.4 ? Δ Tsub ? 15.3 K) were found to have a negligible influence on the saturated CHF. The best methods for predicting the data were those of Wojtan et al. [L. Wojtan, R. Revellin, J. R. Thome, Investigation of critical heat flux in single, uniformly heated microchannels, Exp. Therm. Fluid Sci. 30 (2006) 765–774] and Revellin and Thome [R. Revellin, J. R. Thome, A theoretical model for the prediction of the critical heat flux in heated microchannels, Int. J. Heat Mass Transfer 50 (in press)]. They both predict the experimental CHF results with a mean absolute error of around 9%. Using the critical vapour quality, an annular-to-dryout transition is also proposed as a limit in a diabatic microscale flow pattern map. Pressure drop measurements were measured and analysed, showing that the homogeneous model could correctly predict the observed trends.  相似文献   

6.
Experiments of flow boiling heat transfer were conducted in four horizontal flattened smooth copper tubes of two different heights of 2 and 3 mm. The equivalent diameters of the flattened tubes are 8.6, 7.17, 6.25, and 5.3 mm. The working fluids were R22 and R410A. The test conditions were: mass velocities from 150 to 500 kg/m2 s, heat fluxes from 6 to 40 kW/m2 and saturation temperature of 5 °C. The experimental heat transfer results are presented and the effects of mass flux, heat flux, and tube diameter on heat transfer are analyzed. Furthermore, the flow pattern based flow boiling heat transfer model of Wojtan et al. [L. Wojtan, T. Ursenbacher, J.R. Thome, Investigation of flow boiling in horizontal tubes: Part I – A new diabatic two-phase flow pattern map, Int. J. Heat Mass Transfer 48 (2005) 2955–2969; L. Wojtan, T. Ursenbacker, J.R. Thome, Investigation of flow boiling in horizontal tubes: Part II – Development of a new heat transfer model for stratified-wavy, dryout and mist flow regimes, Int. J. Heat Mass Transfer 48 (2005) 2970–2985], using the equivalent diameters, were compared to the experimental data. The model predicts 71% of the entire database of R22 and R410A ±30% overall. The model predicts well the flattened tube heat transfer coefficients for R22 while it does not predicts well those for R410A. Based on several physical considerations, a modified flow boiling heat transfer model was proposed for the flattened tubes on the basis of the Wojtan et al. model and it predicts the flattened tube heat transfer database of R22 and R410A by 85.8% within ±30%. The modified model is applied to the reduced pressures up to 0.19.  相似文献   

7.
Owing to the generalization problem, there aren't sufficient empirical correlations for two-phase flows. So as to investigate the thermal features of the two-phase flow in smooth and enhanced tubes, a suitable procedure of the models and correlations related with the heat transfer coefficients, friction factors and two-phase multipliers are needed because a significant variation in thermal properties happens during phase-change. Comparison of frictional pressure drop of R134a during flow boiling phenomena occurred in a smooth and 5 enhanced tubes with well-known empirical correlations were performed in this study. The apparatus has 0.85 m long double tube for vertical configuration as a test section that includes smooth and corrugated copper tubing having inner diameters of 0.0087 m, and the range of mass fluxes are between 200 and 400 kg m 2 s 1. The average vapor qualities vary from 0.14 to 0.86, and saturation pressure interval is between 4.5 and 5.7 bar. The mean boiling heat transfer coefficient of R134a is determined via energy balance in the test section. The estimation performance of 36 empirical correlations in literature proposed for convective boiling flows in smooth and corrugated tubes are evaluated by means of authors' database (350 data points for vertical tubes). Boiling trend lines have been plotted for the change of vapor quality, liquid phase Reynolds numbers with gas phase ones. In addition, the most successful correlations are confirmed their predictabilities for the vertical adjusted evaporator having smooth and corrugated tubes using the database of authors' earlier publications in open sources.  相似文献   

8.
This study presents flow visualizations and two-phase frictional pressure drop data for three rectangular channels with channel height of 3, 6 and 9 mm, and a fixed width of 3 mm. It is found that the stratified flow pattern still exists for an aspect ratio of unity at a low mass flux of 100 kg/m2 s but it completely vanishes when G > 200 kg/m2s. For the same plug flow of intermittent flow pattern, the number of plug increases whereas its length decreases when the aspect ratio is increased. This is especially pronounced when the mass flux is further increased over 500 kg/m2 s. The major departure of the observed flow pattern relative to the conventional Mandhane flow map is the transition boundary for slug/annular had been moved to a much lower superficial vapor velocity. The two-phase frictional pressure drop data are compared to homogeneous and Chisholm method, Wambsganss and Ide-Fukano correlations. It is found that none of the existing methods or correlations can satisfactorily predict the two-phase pressure gradient in rectangular channels. A modified C factor of Chisholm method considering the effect of aspect ratio was proposed from the empirical fit with the data sets of Wambsganss et al., Ide-Fukano, and this study. The corresponding mean deviations of the proposed correlation against the datasets are 24.99%, 10.83% and 10.73%, respectively. This correlation is applicable in wide rages of mass flux (50 < G < 700 kg/m2 s), vapor quality (0.001 < x < 0.95), Martinelli parameter (0.05 < X < 20) and aspect ratio (0.1 < A < 1.0).  相似文献   

9.
Two-phase flow phenomena were investigated while boiling R113 and n-pentane in a 241-tube thin slice kettle reboiler. For heat fluxes between 10 and 40 kW/m2, row pressure drop measurements were made in three columns and visual observations of the flow patterns were recorded by a video camera. The height of the two-phase mixture above the tube bundle was also varied. The results revealed that the height of the mixture had little effect on the row pressure drop distribution in each column. At heat fluxes below 10 kW/m2, the pressure drops were reasonably constant. However, at heat fluxes greater than this, the row pressure drop continuously declined.Two one-point-five-dimensional models were developed, one to aid the investigation of static liquid driven lateral flow in the tube bundle, and another to aid the investigation of the cause of the change from reasonably constant to continually declining row pressure drop. The data and the analysis showed that the flow within the tube bundle was always two-dimensional and that the flow pattern was dominated by the static liquid at the tube bundle edge when the heat flux was less than 10 kW/m2. This corresponded to the bubbly flow regime. At larger heat fluxes, the flow pattern changed to intermittent flow. The change occurred when the Kutateladze number was 1.09. Declining row pressure drops occurred in this latter flow regime.  相似文献   

10.
This study presents single-phase and two-phase pressure drop data with oil concentration C = 0, 1, 3 and 5% in a copper wavy tube having an inner diameter of 3.25 mm and a curvature radius of 6.35 mm. The ratio of frictional factor between U-bend in wavy tube and straight tube (fC/fS) is about 1.5 to 2.5 for Re = 2500  25000. The effect of secondary flow is very crucial in the U-bend that it increases the pressure drop considerably. However, the effect of oil concentration on friction factor is negligible provided the properties are based on mixture. The ratio between two-phase pressure gradients of U-bend and straight tube is about 3. This ratio is increased with oil concentration and vapor quality. The oil effect on two-phase pressure drop is especially pronounced at high vapor quality because the effective oil concentration in liquid mixture is increased with vapor quality. The frictional two-phase multiplier for straight tube can be fairly correlated by using the Chisholm correlation. A modified two-phase friction factor based on the Geary correlation is also utilized to predict the frictional two-phase pressure gradient in U-bend. The predictions give a good agreement to the present oil–refrigerant data with a mean deviation of 12.92%.  相似文献   

11.
A complete solution for boiling phenomena in smooth tubes has been giving as a procedure regarding with the calculation of convective heat transfer coefficient and pressure drop using accurate experimental data validated by flow regime maps and sight glasses on the experimental facility. The experimental study is conducted in order to investigate the effect of operating parameters on flow boiling convective heat transfer coefficient and pressure drop of R134a. The smooth tube having 8.62 mm inner diameter and 1100 mm length is used in the experiments. The effect of mass flux, saturation temperature and heat flux is researched in the range of 290–381 kg/m2 s, 15–22 °C and 10–15 kW/m2, respectively. The experiments revealed that the heat transfer coefficient and pressure drop are significantly affected by mass flux for all tested conditions. Moreover, the experimental results are compared with well-known heat transfer coefficient and frictional pressure drop correlations given in the literature. In addition, 122 number of heat transfer and pressure drop raw experimental data is given for researchers to validate their theoretical models.  相似文献   

12.
In this paper, flow patterns and their transitions for refrigerant R134a boiling in a microfinned helically coiled tube are experimentally observed and analyzed. All the flow patterns occurred in the test can be divided into three dominant regimes, i.e., stratified-wavy flow, intermittent flow and annular flow. Experimental data are plotted in two kinds of flow maps, i.e., Taitel and Dukler flow map and mass flux versus vapor quality flow map. The transitions between various flow regimes and the differences from that in smooth straight tube have also been discussed. Martinelli parameter can be used to indicate the transition from intermittent flow to annular flow. The transition from stratified-wavy flow to annular or intermittent flow is identified in the vapor quality versus mass flux flow map. The flow regime is always in stratified-wavy flow for a mass flux less than 100 kg/m2 s.The two-phase frictional pressure drop characteristics in the test tube are also experimentally studied. The two-phase frictional multiplier data can be well correlated by Lockhart–Martinelli parameter. Considering the corresponding flow regimes, i.e., stratified and annular flow, two frictional pressure drop correlations are proposed, and show a good agreement with the respective experimental data.  相似文献   

13.
This article is the second in a three-part study. This second part focuses on flow boiling heat transfer of refrigerant R245fa in a silicon multi-microchannel heat sink and their comparison with the results presented in part I for refrigerant R236fa. This heat sink was the same as utilized in part I. The test conditions covered base heat fluxes from 3.6 to 190 W/cm2, mass velocities from 281 to 1501 kg/m2 s and the exit vapour qualities from 0% to 78%. The effect of saturation pressure on heat transfer was tested from 141 to 273 kPa for R245fa and the effect of sub-cooling from 0 to 19 K. The R245fa database includes 693 local heat transfer coefficient measurements, for which four different heat transfer trends were identified, although in most cases the heat transfer coefficient increased with heat flux, was almost independent of vapour quality and increased with mass velocity. The entire database, including both R245fa and R236fa measurements, was compared with four prediction methods for flow boiling heat transfer in microchannels. The three-zone model of Thome et al. (J.R. Thome, V. Dupont, A.M. Jacobi, Heat transfer model for evaporation in microchannels. Part I: presentation of the model, International J. Heat Mass Transfer 47 (2004) 3375–3385) was found to give the best predictions, capturing 90% of the data within ±30% in the slug and annular flow regimes (x > 5%).  相似文献   

14.
An experimental investigation regarding two-phase diabatic pressure drops inside a helically coiled heat exchanger have been carried out at SIET thermo-hydraulics labs in Piacenza (Italy). The experimental campaign is part of a wide program of study of the IRIS innovative reactor steam generator. The test section consists of an AISI 316 stainless steel tube, 32 m length, 12.53 mm inner diameter, curved in helical shape with a bend radius of 0.5 m and a helix pitch of 0.8 m, resulting in a total height of the steam generator tube of 8 m. The explored operating conditions for two-phase flow experiences range from 192 to 824 kg/m2 s for the mass flux, from 0 to 1 for the quality, from 1.1 to 6.3 MPa for the pressure, from 50 to 200 kW/m2 for the heat fluxes. A frictional two-phase pressure drops correlation, based on an energy balance of the two-phase mixture and including the 940 experimental points, is proposed. Comparison with existing correlations shows the difficulty in predicting two-phase pressure drops in helical coil steam generators.  相似文献   

15.
The pressure-drop characteristics during flow boiling in a single rectangular micro-channel with hydraulic diameter of 0.68 mm are presented. In the present study, pressure drop was studied at heat flux range of 7.63–49.46 kW/m2, mass flux range of 600–1400 kg/m2 s, and saturation temperature of 23, 27 and 31 °C. Experimental results indicated that the total pressure was dominated by frictional pressure drop. The increase of mass flux also increased the frictional pressure gradient, whereas the increase of saturation temperature reduced the frictional pressure gradient. In addition, heat flux also had an insignificant effect on the frictional the pressure gradient. A new correlation was also proposed for effective design of micro-channel heat exchanger.  相似文献   

16.
Critical heat flux (CHF) and pressure drop of subcooled flow boiling are measured for a microchannel heat sink containing 75 parallel 100 μm × 200 μm structured surface channels. The heated surface is made of a Cu metal sheet with/without 2 μm thickness diamond film. Tests and measurements are conducted with de-ionized water, de-ionized water +1 vol.% MCNT additive solution, and FC-72 fluids over a mass velocity range of 820–1600 kg/m2 s, with inlet temperatures of 15(8.6)°C, 25(13.6)°C, 44(24.6)°C, and 64(36.6)°C for DI water (FC-72), and heat fluxes up to 600 W/cm2. The CHF of subcooled flow boiling of the test fluids in the microchannels is measured parametrically. The two-phase pressure drop is also measured. Both CHF and the two-phase friction factor correlation for one-side heating with two other side-structured surface microchannels are proposed and developed in terms of the relevant parameters.  相似文献   

17.
An experimental investigation on two-phase flow boiling heat transfer with refrigerants of R-22, R-134a, R-410A, C3H8 and CO2 in horizontal circular small tubes is presented. The experimental data were obtained over a heat flux range of 5–40 kW m?2, mass flux range of 50–600 kg m?2 s?1, saturation temperature range of 0–15 °C, and quality up to 1.0. The test section was made of stainless steel tubes with inner diameters of 0.5, 1.5 and 3.0 mm, and lengths of 330, 1000, 1500, 2000 and 3000 mm. The experimental data were mapped on Wang et al. (1997) [5] and Wojtan et al. (2005) [6] flow pattern maps. The effects of mass flux, heat flux, saturation temperature and inner tube diameter on the heat transfer coefficient are reported. The experimental heat transfer coefficients were compared with some existing correlations. A new boiling heat transfer coefficient correlation that is based on a superposition model for refrigerants in small tubes is presented with 15.28% mean deviation and ?0.48% average deviation.  相似文献   

18.
An aspect ratio is an important parameter for two-phase flow in a rectangular microchannel. To study the aspect ratio effect on the flow pattern, pressure drop and void fraction, experiments of adiabatic liquid water and nitrogen gas two-phase flow in rectangular microchannels were conducted. The widths and heights of rectangular microchannels are 510 μm × 470 μm, 608 μm × 410 μm, 501 μm × 237 μm and 503 μm × 85 μm. Therefore, the aspect ratios of the rectangular microchannels are 0.92, 0.67, 0.47 and 0.16; and the hydraulic diameters of the rectangular microchannels were 490, 490, 322 and 143 μm, respectively. Experimental ranges were liquid superficial velocities of 0.06–1.0 m/s and gas superficial velocities of 0.06–71 m/s. Visible rectangular microchannels were fabricated using a photosensitive glass. And pressure drop in microchannels was directly measured through embedded ports. The visualization of the flow pattern was carried out with a high-speed camera and a long distance microscope. Typical flow patterns in the rectangular microchannels observed in this study were bubble flow, transitional flow (multiple flow) and liquid ring flow. As the aspect ratio decreased, the bubble flow regime became dominant due to the confinement effect and the thickness of liquid film in corner was decreased. A void fraction in the rectangular microchannels has a linear relation with the volumetric quality. And the two-phase flow becomes homogeneous with decreasing aspect ratio owing to the reduction of the liquid film thickness. Like Zhang et al.’s [19] correlation, as the confinement number increased, the C-value in Lockhart and Martinelli correlation decreased. And a frictional pressure drop in the rectangular microchannels was highly related with the flow pattern.  相似文献   

19.
The present study investigates experimentally the two-phase flow in a rectangular microchannel with CO2 bubbles generated by chemical reactions of sulfuric acid (H2SO4) and sodium bicarbonate (NaHCO3). The microchannel with a hydraulic diameter of 132.7 μm is prepared using bulk micromachining and anodic bonding process. Evolution of two-phase flow patterns in the microchannel was observed using a high speed video camera and the corresponding pressure drop was investigated. It is found that the inlet concentration and flow rate of reactants have a significant effect on the evolution of two-phase flow characteristics and slug flow is the dominant flow pattern. The flow pattern transition instability between bubbly-slug and slug flow takes place for the cases with highest inlet concentration, i.e., C = 0.8 mol/L, and low flow rates of this study. The oscillation frequency is from 0.024 to 0.041 Hz and the magnitude of oscillation in pressure drop is from 10 to 15 kPa. A mechanism based on the flow circulation in the liquid slug may reasonably explain the flow pattern transition instability. Small amplitude, high frequency oscillations with a frequency of about 45 Hz are superimposed on the low frequency flow pattern transition as well as prevail for other cases without the flow pattern transition instability. The two-phase flow pressure drop increases with increase in both flow rate and inlet concentration.  相似文献   

20.
Corresponding to the updated flow pattern map presented in Part I of this study, an updated general flow pattern based flow boiling heat transfer model was developed for CO2 using the Cheng–Ribatski–Wojtan–Thome [L. Cheng, G. Ribatski, L. Wojtan, J.R. Thome, New flow boiling heat transfer model and flow pattern map for carbon dioxide evaporating inside horizontal tubes, Int. J. Heat Mass Transfer 49 (2006) 4082–4094; L. Cheng, G. Ribatski, L. Wojtan, J.R. Thome, Erratum to: “New flow boiling heat transfer model and flow pattern map for carbon dioxide evaporating inside tubes” [Heat Mass Transfer 49 (21–22) (2006) 4082–4094], Int. J. Heat Mass Transfer 50 (2007) 391] flow boiling heat transfer model as the starting basis. The flow boiling heat transfer correlation in the dryout region was updated. In addition, a new mist flow heat transfer correlation for CO2 was developed based on the CO2 data and a heat transfer method for bubbly flow was proposed for completeness sake. The updated general flow boiling heat transfer model for CO2 covers all flow regimes and is applicable to a wider range of conditions for horizontal tubes: tube diameters from 0.6 to 10 mm, mass velocities from 50 to 1500 kg/m2 s, heat fluxes from 1.8 to 46 kW/m2 and saturation temperatures from ?28 to 25 °C (reduced pressures from 0.21 to 0.87). The updated general flow boiling heat transfer model was compared to a new experimental database which contains 1124 data points (790 more than that in the previous model [Cheng et al., 2006, 2007]) in this study. Good agreement between the predicted and experimental data was found in general with 71.4% of the entire database and 83.2% of the database without the dryout and mist flow data predicted within ±30%. However, the predictions for the dryout and mist flow regions were less satisfactory due to the limited number of data points, the higher inaccuracy in such data, scatter in some data sets ranging up to 40%, significant discrepancies from one experimental study to another and the difficulties associated with predicting the inception and completion of dryout around the perimeter of the horizontal tubes.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司    京ICP备09084417号-23

京公网安备 11010802026262号