首页 | 官方网站   微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 62 毫秒
1.
Li L  Chen GH  Li CT  Liu Y  Lin Y  Que TZ  Zhao ZM  Wang YX 《法医学杂志》2006,22(2):111-116
目的建立18个基因座的PCR扩增检测试剂盒。方法采用两个多重PCR体系和四色荧光素标记技术,对Amelogenin和17个STR基因座(D3S1358、vWA、FGA、D8S1179、D21S11、D18S51、D5S818、D13S317、D16S539、TH01、TPOX、CSF1PO、D7S820、D2S1338、D19S433、D12S391和D19S253)进行基因型检测,并对其可靠性、稳定性、效能等进行研究。结果通过2个多重PCR扩增体系,可以成功地对各类生物学检材的Amelogenin和17个STR基因座进行检测,且可靠、稳定、高效。结论本研究所研制的试剂盒,是对该18个基因座进行检测的高效、稳定、可靠的新体系。  相似文献   

2.
Analysis of length polymorphism at short tandem repeat (STR) loci utilizing the polymerase chain reaction (PCR) process has proven to be an ideal assay for human identification purposes. The short length of STR loci coupled with the amplification of target sequence through PCR allows for a robust, sensitive, and specific assay for highly polymorphic markers. A multiplex containing fifteen STR loci plus the gender-determining locus Amelogenin was developed to provide a single amplification/detection of all CODIS (Combined DNA Index System) STR loci (CSF1PO, D3S1358, D5S818, D7S820, D8S1179, D13S317, D16S539, D18S51, D21S11, FGA, TH01, TPOX, and vWA) as well as two internationally-accepted STRs (D2S1338 and D19S433). By incorporating five-dye fragment analysis technology and non-nucleotide linkers, previously optimized AmpFlSTR kit primer sequences have been maintained. This kit has been developed in accordance with the standards of the forensic community as defined by the DNA Advisory Board. Validation studies were performed to include developmental validation, and the results support the use of the AmpFlSTR Identifiler PCR Amplification Kit for human identity and parentage testing.  相似文献   

3.
The PowerPlex 16 BIO multiplex short tandem repeat (STR) system contains the 13 CODIS loci (FGA, TPOX, D8S1179, vWA, D18S51, D21S11, TH01, D3S1358, CSF1PO, D16S539, D7S820, D13S317, and DS5S818), plus two pentanucleotide repeat loci (Penta D and Penta E) and the sex-identifying locus. Amelogenin. The PowerPlex 16 BIO System is optimized for use with the Hitachi FMBIO gel imaging systems. A consortium of seven independent laboratories collaborated to perform the studies defined by the FBI standards for performing a developmental validation, including the evaluation of sample concordance, percent stutter determination, nonprobative casework, precision, sensitivity, mixture determination, effect of substrates, the impact of environmental insults, and species specificity. All samples tested for concordance were consistent except for one sample from the Virginia Division of Forensic Science database that displayed discordance at D13S317, a locus whose primer sequence was altered. Stutter values were comparable to those of other STR multiplex systems, the precision was comparable to other multiplexes analyzed by gel electrophoresis, the DNA profiles were unchanged by the substrate upon which the blood samples were placed, and the nonprobative casework samples re-typed for the PowerPlex 16 BIO System were consistent with previous typing results. When greater than 0.125 ng of DNA was placed into the PowerPlex 16 BIO System amplification reaction, a full profile was generated by all laboratories. The mixture study results were comparable to those reported for other multiplex systems, the environmental study demonstrated a loss of larger molecular weight loci when samples were incubated at elevated temperatures for a prolonged period of time, and the only notable cross species hybridization was observed with primate DNA samples. This extensive validation work performed demonstrates that the PowerPlex 16 BIO System provides STR data of a quality comparable with other PowerPlex STR multiplex kits as well as other widely used STR multiplexes and is thus suitable for evidentiary casework analysis as well as database sample profiling.  相似文献   

4.
DNA typing of degraded DNA samples can be a challenging task when using the current commercially available multiplex short tandem repeat (STR) analysis kits. However, the ability to type degraded DNA specimens improves by redesigning current STR marker amplicons such that smaller sized polymerase chain reaction (PCR) products are generated. In an effort to increase the amount of information derived from these types of DNA samples, the AmpFlSTR MiniFiler PCR Amplification Kit has been developed. The kit contains reagents for the amplification of eight miniSTRs which are the largest sized loci in the AmpFlSTR Identifiler PCR Amplification Kit (D7S820, D13S317, D16S539, D21S11, D2S1338, D18S51, CSF1PO, and FGA). Five of these STR loci (D16S539, D21S11, D2S1338, D18S51, and FGA) also are some of the largest loci in the AmpFlSTR SGM Plus kit. This informative nine-locus multiplex, which includes the gender-identification locus Amelogenin, has been validated according to the FBI/National Standards and SWGDAM guidelines. Our results demonstrate significant performance improvements in models of DNA degradation, PCR inhibition, and nonprobative samples when compared to the AmpFlSTR Identifiler and SGM Plus kits. These data support that the MiniFiler kit will increase the likelihood of obtaining additional STR information from forensic samples in situations in which standard STR chemistries fail to produce complete profiles.  相似文献   

5.
目的建立五色荧光18个基因座的复合扩增检验体系。方法设计、合成引物,通过调整引物浓度和复合扩增条件,建立起五色荧光复合扩增体系,包含Amelogen、D6S1043、D21S11、D7S820、CSF1PO、D2S1338、D3S1358、D13S317、D8S1179、D16S539、PentaE、TH01、TPOX、PentaD共计18个基因座。结果该复合扩增系统检验结果稳定,分型准确。结论五色荧光18个基因座复合扩增系统构建成功。  相似文献   

6.
The Gene Print PowerPlex 1.1/Amelogenin and FFFL Fluorescent STR Systems have been validated following the recommendations presented by the Technical Working Group on DNA Analysis Methods (TWGDAM). The PowerPlex 1.1/Amelogenin System supports simultaneous amplification of eight short tandem repeat loci and the Amelogenin gender identification marker. The loci D16S539, D7S820, D13S317, and D5S818 are labeled with fluorescein (FL) while the loci CSF1PO, TP0X, TH01, vWA and Amelogenin are labeled with carboxy-tetramethylrhodamine (TMR). The FFFL Multiplex System is composed of the loci F13A01, FESFPS, F13B, and LPL, each labeled with fluorescein. We have observed no overlap of alleles across loci labeled with an individual fluorescent dye. Samples of each system were amplified and labeled in a single reaction, separated by electrophoresis through a denaturing polyacrylamide gel, and amplified alleles detected using a Hitachi FMBIO Fluorescent Scanner. Alterations from the standard amplification protocols in cycle number and annealing temperature generally produced excellent results. In experiments testing sensitivity as little as 0.2 ng of DNA template could be detected. As expected, different body fluids from the same individuals generated identical DNA profile results. Template DNA derived from blood-strains deposited on a variety of matrix supports displayed robust amplification except for material derived from deposits on wood and Japanese orchid leaves. Mixtures of DNA templates could be interpreted with the minor component present in as little as ten percent of the total sample. Monoplex and multiplex amplifications produced identical amplified allele patterns, indicating that STR multiplex systems save template and increase efficiency in the amplification procedure without loss of quality. Analyses of genotype frequencies in African-American, Caucasian-American and Hispanic-American populations using all twelve loci were used to determine matching probabilities smaller than 1 in 1.14 x 10(8) and 1 in 2658 for the PowerPlex 1.1 and the FFFL Multiplex Systems, respectively. The matching probability achieved with the two systems combined is smaller than 1 in 3.03 x 10(11). The independence of alleles within loci was generally demonstrated by applying the exact test to demonstrate Hardy-Weinberg Equilibrium. All of the studies performed indicate that the PowerPlex 1.1/Amelogenin and FFFL Multiplex Systems are powerful, robust, and reliable investigative tools that can be used in the analysis of forensic samples.  相似文献   

7.
The amplification and typing conditions for the 13 core CODIS loci and their forensic applicability were evaluated. These loci are CSF1PO, FGA, TH01, TPOX, vWA, D3S1358, D5S818, D7S820, D8S1179, D13S317, D16S539, D18S51, and D21S11. Results were obtained using the multiplex STR systems AmpFlSTR Profiler Plus and AmpFlSTR COfiler (Applied Biosystems, Foster City, CA), GenePrint PowerPlex (Promega Corporation, Madison, WI), and subsets of these kits. For detection of fluorescently labeled amplified products, the ABI Prism 310 Genetic Analyzer, the ABI Prism 377 DNA Sequencer, the FMBIO II Fluorescent Imaging Device, and the Fluorlmager were utilized. The following studies were conducted: (a) evaluation of PCR parameter ranges required for adequate performance in multiplex amplification of STR loci, (b) determination of the sensitivity of detection of the systems, (c) characterization of non-allelic PCR products, (d) evaluation of heterozygous peak intensities, (e) determination of the relative level of stutter per locus, (f) determination of stochastic PCR thresholds, (g) analysis of previously typed case samples, environmentally insulted samples, and body fluid samples deposited on various substrates, and (h) detection of components of mixed DNA samples. The data demonstrate that the commercially available multiplex kits can be used to amplify and type STR loci successfully from DNA derived from human biological specimens. There was no evidence of false positive or false negative results and no substantial evidence of preferential amplification within a locus. Although at times general balance among loci labeled with the same fluorophore was not observed, the results obtained were still valid and robust. Suggested criteria are provided for determining whether a sample is derived from a single source or from more than one contributor. These criteria entail the following: (a) the number of peaks at a locus, (b) the relative height of stutter products, and (c) peak height ratios. Stochastic threshold levels and the efficiency of non-templated nucleotide addition should be considered when evaluating the presence of mixtures or low quantity DNA samples. Guidelines, not standards, for interpretation should be developed to interpret STR profiles in cases, because there will be instances in which the standards may not apply. These instances include (a) a primer binding site variant for one allele at a given locus, (b) unusually high stutter product, (c) gene duplication, and (d) translocation.  相似文献   

8.
A population study of Caucasians residing in Maine was conducted using the AmpF1STR Profiler PCR Amplification Kit and the AmpF1STR Profiler Plus PCR Amplification Kit (Applied Biosystems Division (ABD) of Perkin Elmer, Foster City, CA). The kits contain the reagents necessary to amplify 12 different STR loci and the gender marker Amelogenin using two multiplex PCR, each containing nine STR loci. Thus, there is an overlap of six STR loci. The 12 STR loci are TH01, TPOX, CSF1PO, D3S1358, vWA, FGA, D8S1179, D21S11, D18S51, D5S818, D13S317, and D7S820. These loci represent 12 of the 13 core loci selected by the CODIS STR standardization project. Dye-labeled amplification products were separated and detected using the capillary electrophoresis instrument ABI Prism 310 Genetic Analyzer. Allele frequencies were determined for the 12 STR loci. Statistical analysis of the data included Hardy-Weinburg equilibrium (HWE) analysis, pairwise independence testing, power of discrimination (PD), and probability of exclusion (PE).  相似文献   

9.
A multiplex PCR was developed for the analysis of the sex-determining gene Amelogenin, four conventional STR (short tandem repeat; THO1, D18S51, D21S11 and FGA) loci with a reduced amplicon size and four miniSTR loci (D1S1677, D2S441, D10S1248 and D22S1045). A concordance study in a population of 198 Belgians revealed no differences for the conventional STR loci while a sensitivity study showed a reproducible DNA profile with as low as 30 pg of input DNA.  相似文献   

10.
Du Z 《法医学杂志》2000,16(1):1-5
目的:对D3S1358、vWA、FGA、D8S1179、D21S11、D18S51、D5S818、D13S317、D16S539、THO1、TPOX、CSF1PO、D7S820等13个STR位点进行多态性调查,探索其用于"罪犯DNA数据库"的可行性.方法:用多重PCR和四色荧光自动化检测技术分析13个STR位点的基因型,计算各位点等位基因的分布频率.结果:获得13个STR位点在中国南北汉族、维吾尔族、回族人群中的等位基因分布频率资料.结论:上述位点适合作为中国人群的遗传学标志,用于"中国罪犯DNA数据库"的建立.  相似文献   

11.
青岛地区汉族人群13个STR基因座的频率分布及法医学应用   总被引:9,自引:0,他引:9  
目的 调查青岛地区汉族人群无关个体的 13个STR基因座 (D3S135 8、VWA、FGA、D8S1179、D2 1S11、D18S5 1、D5S818、D13S317、D7S82 0、D16S5 39、TH0 1、TPOX、CSFIPO)的基因频率分布 ,研究其遗传多态性及其在法医学个体识别及亲子鉴定中的应用价值。 方法 用美国ABI - 310型遗传分析仪对ProfilerPlus和Cofiler两个系统的 13个STR基因座的复合扩增产物进行毛细管电泳及四色荧光自动分析检测 ,基因分型软件为GeneScanv3.1和Genotyperv2 .5 .2。  结果 获得 13个STR基因座在青岛地区汉族人群的基因频率分布数据 ,13个STR基因座的PIC >0 .5 ,DP >0 .71,CCE =0 .999999,TDP值接近 1,TPm =1.2× 10 -14 ,家系调查符合孟德尔遗传规律。 结论 ProfilerPlus和Cofiler两个系统的 13个STR基因座在法医学个体识别及亲子鉴定中具有较高的应用价值。  相似文献   

12.
目的建立扩增片段<135bp,包括D5S818,D8S1179,D16S539 3个miniSTR基因座复合扩增系统。方法采用不同荧光染料标记引物,通过PCR扩增,利用ABI 3100遗传分析仪进行片段长度分析,对100份无关个体血样,10个家系样本以及30份高度降解检材进行检测。结果本系统DNA分型结果与AmpFLSTR Identifiler试剂盒完全一致,且灵敏度高于AmpFLSTR Identifiler试剂盒。结论本系统可以应用于个人识别和亲权鉴定,为降解DNA样本分型提供了新的方法。  相似文献   

13.
广东地区汉族人群 13个 STR基因座的频率调查   总被引:10,自引:0,他引:10  
Li Y  Wang SB  Liu C  Li HX  Hu HY  Liu H  Liu CH  Chen XH 《法医学杂志》2001,17(2):82-85
目的调查广东地区汉族无关个体的 13个 STR基因座( D3S1358、 vWA、 FGA、 D8S1179、 D21S11、 D18S51、 D5S818、 D13S317、 D7S820、 D1 6S539、 TH01、 TPOX、 CSF1PO)多态性,研究其在法医学检验中的应用价值。方法用 AmpFlSTR Profiler Plus及 Cofiler二个荧光标记系统对新鲜血样进行 13个基因座的复合扩增,用 ABI 377-96全自动测序仪对扩增产物进行检测,用 GenoTyper软件进行基因分型。结果 13个基因座 PIC >0.5,DP >0.76,家系调查符合孟德尔遗传规律。结论含有 13个 STR基因座的二个荧光标记复合扩增系统可满足法医物证学的个体识别及亲权鉴定的需要。  相似文献   

14.
In order to increase the power of discrimination for human identification purposes, a nine-locus short tandem repeat (STR) multiplex, the GenePrint PowerPlex 2.1 system (PowerPlex 2.1) developed by Promega Corporation and a separate pentanucleotide-repeat locus, Penta D, were tested. This megaplex system includes the highly polymorphic loci FGA, TPOX, D8S1179, vWA, Penta E, D18S51, D21S11, TH01, and D3S1358 and may be used in combination with the eight-locus STR multiplex, the GenePrint PowerPlex 1.1 system (PowerPlex 1.1) that has been previously developed. Three of the loci, TPOX, TH01 and vWA, have been included in both systems for quality control purposes. As with PowerPlex 1.1, PowerPlex 2.1 is also based on a two-color detection of fluorescent-labeled DNA products amplified by polymerase chain reaction (PCR) and provides a valuable tool for accurate and rapid allele determination. The primer sequences used in the PowerPlex 2.1/Penta D system are also presented in this report. To meet the "Quality Assurance Standards for Forensic DNA Testing Laboratories" (FBI), we tested the efficiency and reproducibility of the PowerPlex 2.1/PentaD system by several validation studies that were conducted as a joint project among seven laboratories. Validation tests included concordance studies, sensitivity, and species specificity determination, as well as performance in forensic and environmentally impacted samples. The results produced from these tests demonstrated the consistency and reliability of the PowerPlex 2.1/Penta D system.  相似文献   

15.
A total of 171 Caucasians living in Andalucia (southern Spain) have been typed for nine short tandem repeat (STR) loci by multiplex PCR amplification using a commercially available kit (Profiler Plus; Perkin–Elmer, Norwalk, CT, USA) and semi-automatic electrophoresis (ABI Prism 377 DNA Sequencer, Applied Biosystems, Foster City, CA, USA). The kit enables typing of the STR loci D3S1358, VWA, FGA, D5S818, D13S317, D7S820, D8S1179, D21S11, and D18S51. All loci, except D7S820, meet Hardy–Weinberg equilibrium. Because of the large number of loci that can be analyzed, the power of discrimination (PD) is greater than 0.99999, and the probability of exclusion (PE) reaches 0.99991 in our population sample.  相似文献   

16.
17.
For highly degraded DNA samples of forensic casework, new miniSTR systems have been developed to supplement the current STR systems. In the present study, nine miniSTR loci were analyzed in 300 unrelated Koreans using three multiplex PCR systems (multiplex I: D10S1248, D14S1434 and D22S1045; multiplex II: D1S1677, D2S441 and D4S2364; and multiplex III: D3S3053, D6S474 and D20S482), and allele frequencies and forensic parameters were calculated. These data demonstrated that D10S1248, D2S441, D22S1045, D14S1434, and D6S474 are as highly informative as the CODIS STRs suggesting that the miniSTRs could be useful for forensic analysis of degraded DNA.  相似文献   

18.
The present communication presents a new triplex PCR co-amplifying three loci (D3S1358, D8S1179 and D18S51) recommended for STR typing by the European Network of Forensic Science Institutes (ENFSI). Twenty-two different primers were tested to optimise the PCR. Four of the six primer sequences finally chosen were self selected, the fifth was a published one and the sixth derived from a commercially available multiplex kit. Using this PCR-setup, even minimum amounts of genomic DNA are sufficient to analyse the STR loci D3S1358, D8S1179 and D18S51 in parallel. Especially in forensic casework, where DNA is mostly limited and often contaminated with enzyme inhibitors, this new PCR proved to be very advantageous. To demonstrate the reliability, buccal swabs from 2874 persons were typed not only with the new triplex PCR but also with a commercially available multiplex kit.  相似文献   

19.
Locked nucleic acids (LNAs) are a conformationally restricted DNA analog, which can be incorporated into oligonucleotides to increase binding strength. To investigate if LNAs increase amplification success for trace DNA samples in a forensic context, primer sequences for four routinely used STR loci (FGA, D7S820, D13S317 and D18S51) have been altered to include LNA bases. The LNA modified primers display a broader tolerance to a range of reaction conditions compared to unmodified DNA primers, with higher Tms giving increased specificity. Increased peak heights, improved peak height ratios and decreased template requirements were seen with LNA primers. The increased amplification success of LNA primers, and broader range of optimal reaction conditions, suggest that using LNA primers for multiplex STR genotyping assays could be highly beneficial for trace DNA genotyping.  相似文献   

20.
A set of 212 samples from unrelated Spanish Caucasians living in Andalucia (southern Spain) were analyzed with a new commercially-available kit for multiplex amplification of 3 STR loci (D13S137, D7S820, and D16S539), manual denaturing polyacrylamide gel electrophoresis and silver staining. These three loci are of special interest for the forensic community since they are a part of the 13 CODIS-core STR loci. The results show that the loci D13S317 and D16S539 meet Hardy-Weinberg expectations (HWE), but the locus D7S820 did not meet HWE (p = 0.003). However, there was no detectable departures from independence (i.e., linkage disequilibrium) between any pair-wise combination of loci. The D7S820 data were further investigated. The excess homozygosity was due to an excess of D7S820 10, 10 homozygotes. To determine if the allele frequency data are meaningful and can be applied to forensic identity cases, the Spanish D7S820 allele frequency data were compared with four other Caucasian sample populations. The D7S820 allele frequencies were statistically similar; thus, the results support that the allele frequency data can be used reliably for estimating DNA profile frequencies.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司    京ICP备09084417号-23

京公网安备 11010802026262号