首页 | 官方网站   微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
We report a highly sensitive enzyme immunoassay for dehydroepiandrosterone (DHEA) and its sulfate (DHEA-S) using horseradish peroxidase as the label enzyme. Separation of free and bound DHEA-peroxidase conjugate was by insolubilized antibody, prepared by coupling purified IgG of goat anti-rabbit IgG serum with Sepharose 4B or a polystyrene tube. The enzyme activity was measured by the chemiluminescence reaction using luminol and hydrogen peroxide as substrate. The faint chemiluminescence was measured by a photon counter. The sensitivity was 25 pg/assay tube for DHEA and 100 pg/assay tube for DHEA-S. Upon comparison, results obtained by radioimmunoassay and this method showed good agreement; r = 0.86 for free DHEA, r = 0.92 for acid-hydrolyzed DHEA-S and r = 0.91 for solvolyzed DHEA-S. The present method is applicable in the routine determination of DHEA and DHEA-S in biological fluid.  相似文献   

2.
A sensitive direct enzyme immunoassay for urine pregnanediol-3 alpha-glucuronide was developed. The assay system involves the use of an antiserum against pregnanediol-3 alpha-glucuronide and an enzyme-labelled antigen chemically prepared by linking beta-D-galactosidase to 20 alpha-hydroxy-5 beta-pregnane 3(O-carboxymethyl)oxime. Free from antibody-bound antigen was separated by a solid-phase double antibody method, using a microplate coupled with goat anti-rabbit gamma-globulin. This solid-phase enzyme immunoassay for urine pregnanediol-3 alpha-glucuronide was validated in terms of specificity, accuracy and sensitivity. When urine samples were assayed for pregnanediol-3 alpha-glucuronide, the results obtained by the solid phase enzyme immunoassay and conventional radioimmunoassay methods agreed well (n = 30, r = 0.922). This assay system has an advantage over radioimmunoassay, because it does not require the use of radioisotopes. The procedure of this method is very simple, since it does not require purification steps of the biological samples.  相似文献   

3.
A highly sensitive and reproducible enzyme-immunoassay for the measurement of thromboxane B2 was developed. Thromboxane B2 (TxB2) was coupled with beta-D-galactosidase by mixed anhydride reaction. Thromboxane B2-antiserum was generated in rabbits and used at a final dilution of 1:480,000. The separation of immunocomplex from the free form of TxB2 was accomplished by the double antibody method. The second antibody was sheep anti rabbit IgG. The precipitated enzyme activity was measured fluorometrically with 4-methyl-umbelliferyl-beta-D-galactoside as substrate. This method allowed to measure TxB2 in the range of 0.002-5 picomole per tube. The cross-reactivity of the anti-thromboxane B2-antiserum with 2,3-dinor thromboxane B2 was about 20%, but it was less than 0.2% for the other prostanoids tested. TxB2 extracted from human urine was measured by enzyme-immunoassay (y) and radioimmunoassay (x) which has been found closely correlated to values obtained by gas chromatography-mass spectrometry. Regression analysis of the data comparing enzyme-immunoassay and radioimmunoassay gave the equation y = 0.996 x + 0.470, correlation coefficient r = 0.9947. Inter-assay coefficient of variation was 3.1%. The assay was further simplified by coating the second antibody on glass beads. The regression equation between this solid-phase enzyme immunoassay (y) and radioimmunoassay (x) was y = 0.9860 X 1.927, r = 0.9895, and enzyme immunoassay (y) was y = 0.9749 X -0.94808, r = 0.9887. Thus, the enzyme-immunoassay shows specificity and sensitivity comparable to radioimmunoassay making use of radioactive tracer unnecessary.  相似文献   

4.
A simple and sensitive method for in situ amplified electrochemical immunoassay of human serum IgG has been developed by using double-codified nanosilica particles as labels based on horseradish peroxidase-doped nanosilica particles (HRP-SiO(2)) with the conjugation of anti-IgG antibodies (anti-IgG-SiO(2)-HRP). With the sandwich-type immunoassay format, the linear range of the developed immunosensor by using anti-IgG-SiO(2)-HRP as tracer and hydrogen peroxide (H(2)O(2)) as enzyme substrate is 0.01-15 nmol/L IgG with a detection limit of 5.0 pmol/L, while the assay sensitivity by directly using HRP-labeled anti-IgG as secondary antibodies is 1.0-10 nmol/L with a detection limit of 0.1 nmol/L IgG. The reproducibility, stability and specificity of the proposed immunoassay method were acceptable. The IgG concentrations of the clinical serum specimens assayed by the developed immunosensor show consistent results in comparison with those obtained by commercially available enzyme-linked immunosorbent assay (ELISA) method.  相似文献   

5.
A highly sensitive and reproducible enzyme-immunoassay for the measurement of thromboxane B2 was developed. Thromboxane B2 (T×B2) was coupled with β-D- galactosidase by mixed anhydride reaction. Thromboxane B2-antiserum was generated in rabbits and used at a final dilution of 1:480,000. The separation of immuno- complex from the free form of TxB2 was accomplished by the double antibody method. The second antibody was sheep anti rabbit IgG. The precipitated enzyme activity was measured fluorometrically with 4-methyl-umbelliferyl-gb-D-galactoside as substrate.This method allowed to measure TxB2 in the range of 0.002 - 5 picomole per tube. The cross-reactivity of the anti-thromboxane B2-antiserum with 2,3-dinor thromboxane B2 was about 20%, but it was less than 0.2% for the other prostanoids tested.TxB2 extracted from human urine was measured by enzyme-immunoassay (y) and radioimmunoassay (x) which has been found closely correlated to values obtained by gas chromatography-mass spectrometry. Regression analysis of the data comparing enzyme-immunoassay and radioimmunoassay gave the equation y = 0.996 x + 0.470, correlation coefficient r = 0.9947. Inter-assay coefficient of variation was 3.1%.The assay was further simplified by coating the second antibody on glass beads. The regression equation between this solid-phase enzyme immunoassay (y) and radioimmunoassay ( (x) was y = 0.9860 × 1.927, r = 0.9895, and enzyme immunoassay (y) was y = 0.9749 × −0.94808, r = 0.9887. Thus, the enzyme-immunoassay shows specificity and sensitivity comparable to radioimmunoassay making use of radioactive tracer unnecessary.  相似文献   

6.
A highly sensitive and specific solid-phase enzyme immunoassay system for terminal deoxynucleotidyl transferase (TdT, EC 2.7.7.31) has been developed by the use of monospecific antibody against calf thymus TdT and β-d-galactosidase from Escherichia coli as label. The immunoassay system was composed of solid phase (polystyrene beads) with immobilized F(ab′)2 antibody fragments and the antibody Fab′ fragments labeled with β-d-galactosidase. The minimum detectable concentration of calf TdT was 0.1 ng/ml (0.01 ng/assay), making it more sensitive than the radioimmunoassay or enzyme immunoassay methods that use alkaline phosphatase as label, as reported previously. The assay system cross-reacted with human TdT, and TdT in neoplastic cells or sera from leukemic patients was successfully detected by the present immunoassay method.  相似文献   

7.
The development of a sandwich enzyme immunoassay for rat retinol-binding protein using molecular biological techniques was described. Rat retinol-binding protein gene cloned by the PCR method was expressed by a fusion vector pEZZI8 in Escherichia coli strain HB101. A recombinant retinol-binding protein fused with IgG-binding domain ZZ of protein A was purified with IgG-Sepharose. Antibody against the recombinant protein was found to be specific to rat retinol-binding protein in plasma by immunoblot analysis. Affinity-purified anti-recombinant protein IgG was biotinylated and used for the sandwich enzyme immunoassay. In this assay, the measurable range is 1.9-60 ng/ml and the coefficients of variation within and between the assay series (assay range: 4-30 ng/ml) are 4.30 ± 4.33 and 5.32 ± 1.45%, respectively. Cross-reactivity of the immunoassay was examined using bovine, human, and mouse serum. There was a cross-reaction only with mouse serum. In an in vitro experiment, retinol-binding protein produced by rat hepatocytes could be measured by the sandwich enzyme immunoassay.  相似文献   

8.
A new and highly sensitive enzyme immunoassay of cortisol was established using horseradish peroxidase as the label. Separation of free and bound cortisol was effected by insolubilized anti-cortisol antibody which was prepared by coupling the purified immunoglobulin G of antiserum with Sepharose 4B. The enzyme activity was measured by the chemiluminescence reaction using luminol and hydrogen peroxide as substrate. The faint chemiluminescence was measured by a photon counter. Comparison of assay results obtained by radioimmunoassay and this enzyme immunoassay showed excellent agreement of results in all cases (r = 0.913). The detection limit of cortisol was about 10 pg per assay tube. This enzyme immunoassay is applicable to the routine determination of plasma cortisol.  相似文献   

9.
F Tamamura  T Nakao  N Tsunoda  K Kawata 《Steroids》1982,39(6):657-666
An enzyme immunoassay for estrone in swine serum was established. For this, beta-galactosidase from E. coli was conjugated through estrone-17 (O-carboxymethyl)oxime using a mixed anhydride reaction. The percentage of immunoreactive estrone-17 (O-carboxymethyl)oxime-beta-galactosidase conjugate was estimated to be about 70%. The recovery rate of estrone (25-500 pg) added to 0.05 ml of swine serum averaged 91.4%. The sensitivity of the present enzyme immunoassay was 5 pg/tube. The coefficients of variation (CV) were 5.9-8.2% (within assays) and 4.1-5.9% (between assays), respectively. Estrone values determined by the present enzyme immunoassay were highly correlated with those determined by radioimmunoassay (r = 0.99, P less than 0.005). This method of enzyme immunoassay was determined to be suitable for the routine assay of serum estrone.  相似文献   

10.
We developed a highly sensitive chemiluminescent (CL) assay for hydrogen peroxide using 10‐methyl‐9‐(phenoxycarbonyl) acridinium fluorosulfonate (PMAC) that produced chemiluminescence under neutral conditions and applied it to an enzyme immunoassay (EIA). One picomole of hydrogen peroxide could be detected using the optimized PMAC‐CL method and 6.2 × 10‐20 mol β‐d ‐galactosidase (β‐gal) could be detected by combining an indoxyl derivative substrate and the proposed PMAC‐CL method. This highly sensitive CL β‐gal assay was applied to an EIA for thyroid‐stimulating hormone (TSH) using β‐gal as a label enzyme; 0.02–100.0 μU/mL TSH in human serum could be assayed directly and with high reproducibility. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

11.
The value as a thyroid function test of a new, rapid, and highly sensitive immunoradiometric assay for thyroid stimulating hormone (TSH) was assessed in 188 consecutive new patients with suspected hyperthyroidism. The diagnosis was made on clinical grounds and on the basis of serum total triiodothyronine and thyroxine concentrations and the response of TSH to thyrotrophin releasing hormone (TRH) as measured by radioimmunoassay. In all except one patient the basal TSH concentration by immunoradiometric assay predicted the response of TSH by radioimmunoassay to TRH, an undetectable value being recorded in patients with a subnormal response and a measurable value in those with a normal test result. This clear relation was not observed for basal TSH concentrations as measured by radioimmunoassay. In a series of 39 hospital inpatients with acute or chronic non-thyroidal illness, of whom 11 had low concentrations of total thyroxine or triiodothyronine, or both, basal TSH concentrations were detectable by both radioimmunoassay and immunoradiometric assay in all cases and were associated with normal responses to TRH. The immunoradiometric assay for TSH, which is commercially available, may therefore obviate the need for the more time consuming TRH test and simplify the approach to thyroid function testing in patients with suspected hyperthyroidism.  相似文献   

12.
BackgroundStrongyloides stercoralis (Ss) is the etiological agent of strongyloidiasis, a neglected tropical disease of global concern. Laboratory diagnosis of strongyloidiasis is most often based on detection of antibodies against antigens in an enzyme linked immunosorbent assay (ELISA). Herein, we report a preliminary validation study of newly developed IgG4- and/or IgG- based ELISAs to detect strongyloidiasis (Strongy Detect, InBios) incorporating a cocktail of 2 previously described recombinant antigens, Ss-NIE and Ss-IR.MethodsThe sensitivity and specificity were determined by using the assay in 150 cryopreserved serum samples from humans known to be Ss infected (n = 74), helminth uninfected (n = 47), or infected with a helminth other than Ss [n = 29). The treatment associated dynamics of antibody detection were then assessed using 35 paired samples obtained before and after definitive therapy.ResultsThe IgG and IgG4 assays were 99% and 96% sensitive, respectively, and 99% and 100% specific, respectively. Neither the IgG or IgG4 assay showed cross reactions with sera from those infected with other helminths. Although ELISA values did decline post-treatment few returned to levels below the cutoff for infection.ConclusionStrongy Detect is the most sensitive and specific commercialized immunoassay for detection of strongyloidiasis. The assay remains positive for greater than a year post-treatment.  相似文献   

13.
In an attempt to analyze thyroid stimulators in serum we developed an assay procedure using hTSH radioimmunoassay (RIA) in combination with receptor competition. The principle of this method is the determination by RIA of hTSH displaced by other thyroid stimulators from a thyroidal receptor preparation which previously bound unlabelled hTSH. Practically 4 microunits of hTSH were bound with human or bovine receptor, and then hTSH displaced by addition of test serum (0.1 ml) or samples dissolved in serum (0.1 ml) was measured by RIA. This assay can determine the thyroid stimulators other than hTSH in serum that has the displacement activity of 0.5-4.0 microunits of hTSH in the useful range, such as mU/ml level of bovine TSH or rat TSH. Cholera toxin that has the thyroid stimulating activity like TSH also showed the displacement of the bound hTSH. This assay is not applicable for the human serum with more than 5 microunits/ml of TSH, because the assay value is over estimated by the free hTSH derived from the test serum. On the other hand, eighteen sera with high LATS activity and 42 sera with negative LATS activity from patients with untreated hyperthyroidism did not show any displacement. This might be due to the lower binding activity of LATS with hTSH receptor or the lower sensitivity of this assay method. Although it is difficult to use this assay clinically because of its low sensitivity, increased TSH in animal serum can be determined by this assay. The principle of this method may be also useful for examining the receptor binding of other peptide hormone that can be determined by an RIA method.  相似文献   

14.
We describe an enzyme immunoassay for testosterone in which we use a testosterone-3-(carboxymethyl)oxime horseradish peroxidase conjugate as the label and an antiserum, raised in rabbits, to testosterone-3-(carboxymethyl)oxime-bovine serum albumin conjugate. Polyethylene glycol (Carbowax 6000) is used to separate antibody-bound and free steroid. The assay has a sensitivity of 12 pg/assay tube and satisfies the usual criteria of specificity, precision and accuracy. The results agree well with those obtained with a comparable radioimmunoassay.  相似文献   

15.
A solid phase, particle concentration fluorescence immunoassay (PCFIA) was developed for the measurement of prostaglandin (PG) D synthase in the 100,000g supernatant of various regions of the rat central nervous system. In this assay, the enzyme (in the range of 1-25 micrograms protein of brain supernatant or 1-100 ng of the purified enzyme) is attached to submicrometer carboxypolystyrene beads coated with polyclonal anti-rat brain PGD synthase IgG. The total particle-bound enzyme is assayed with fluorescein isothiocyanate (FITC)-conjugated monoclonal anti-PGD synthase IgG after incubation for 1 h. The optimum assay condition was obtained when carboxyl particles coated with ca. 500 micrograms/ml of polyclonal IgG at pH 5.0 and 5 micrograms/ml of FITC-IgG were used. No significant fluorescence was observed when FITC conjugates or carboxyl particles were prepared using IgG from nonimmunized rabbits. Heat treatment of the brain supernatant decreased the specific binding of the enzyme in parallel with the loss of enzyme activity, indicating that the denatured enzyme is not recognized by this assay method. The PGD synthase immunoreactivity was widely distributed in the brain regions and was highest in the paraflocculus. Although slight discrepancy was observed between the concentration by PCFIA and the enzyme activity measured by using [14C]PGH2 in some brain regions, there is a considerable correlation (0.727) between the values by both methods in the same brain regions. The PCFIA now developed showed higher sensitivity (around 10 times), greater reliability, and larger number of samples measurable at once than the radio-TLC assay using [14C]PGH2. This method could provide valuable information concerning the regulatory mechanisms of PGD synthase.  相似文献   

16.
A solid-phase enzyme immunoassay for prostaglandin D2 (PGD2) was developed in which PGD2 was labeled with horseradish peroxidase. After competitive binding to the immobilized antibody between enzyme-labeled and free PGD2, the activity of the enzyme bound to the antibody was assayed fluorometrically using 3-(p-hydroxyphenyl)-propionic acid and hydrogen peroxide as substrates. The procedure allowed determinations of 3-100 pg for PGD2. The IC50 value for PGD2 in the solid-phase enzyme immunoassay was about 25 pg and the sensitivity was improved about 10 times compared to those in radioimmunoassay and in solution-phase enzyme immunoassay. The solid-phase enzyme immunoassay was applied to the measurement of PGD2 content in rat brain and thereby an octadecylsilyl silica cartridge and a reversed-phase HPLC were sequentially used for sample preparations. Heads were immediately frozen in liquid nitrogen after decapitation to avoid a postmortem formation of PGD2. PGD2 contents measured by solid-phase enzyme immunoassay correlated well with the values obtained by radioimmunoassay (r = 0.966) after raising its contents by intravenous administration of PGD2. The in vivo level of PGD2 in rat brain was extremely low but determined to be 0.11 +/- 0.03 ng/g tissue (mean +/- S.E.M.) with this enzyme immunoassay. The result was equal to the value extrapolated to zero time from the postmortem change.  相似文献   

17.
A highly specific and sensitive enzyme-linked immunosorbent assay, using a heterologous combination of antiserum raised against testosterone-3-(O-carboxymethyl) oxime-bovine serum albumin and penicillinase-labeled testosterone-11 beta-carboxymethyl ether, was developed for measuring testosterone in human plasma. Immunoassay plates (96 wells) provided a sensitivity of 2.5 pg/well. This was achieved by maintaining the molar ratios of steroid to enzyme between 10 and 20. The assay was very specific for testosterone and did not show any cross-reaction with the related C19 steroids tested. Replacement of immunoassay plates with the locally available polypropylene tubes raised the detection limits to 25 pg/tube, but improved the range of doses of testosterone that could be measured up to 10,000 pg. The antiserum to testosterone derivative was linked to both immunoassay plates and polypropylene tubes through immunochemical bridges. Comparison of testosterone values of 52 plasma specimens obtained by both solid phase methods with those of radioimmunoassay showed good correlation.  相似文献   

18.
A competitive, double antibody enzyme immunoassay for oxytocin in a heterologous system was developed. Horseradish peroxidase was conjugated with oxytocin using N-succinimidyl 3-(2-pyridyldithio) propionate, and rabbit anti-oxytocin serum was produced by immunization of oxytocin-bovine serum albumin complex which was prepared by the carbodiimide method. The sensitivity of the assay was 4 microIU/tube, which corresponded to 10 microIU per ml using 400 microliters of the sample which was extracted from the same volume of plasma by means of SEP-PAK C18 cartridges. The coefficients of variation for different levels of oxytocin ranged from 6.8-15.9% and 8.5-16.7%, for intra- and inter-assay. Recovery of oxytocin added to plasma after extraction was 99-117%. No or little cross-reaction with arginine- and lysine-vasopressin was found. Plasma oxytocin concentrations determined by the proposed enzyme immunoassay were well correlated with those determined by radioimmunoassay (r = 0.90).  相似文献   

19.
An enhanced chemiluminescence enzyme immunoassay for serum progesterone   总被引:1,自引:0,他引:1  
A competitive enhanced luminescent enzyme immunoassay for serum progesterone is described, which is based on a 11 alpha-hydroxyprogesterone 11-hemisuccinyl-horseradish peroxidase conjugate and a black polystyrene microtitre plate sensitised with anti-progesterone IgG. Bound label was determined using a mixture of 4-iodophenol, luminol and peroxide, and the light emitted from the wells of the plate quantitated using a luminescent plate reader. The assay was sensitive (detection limit 0.5 pg), precise (CV 2.7 - 9.0% in the concentration range 4.3-67.7 nM) and showed good correlation (r = 0.99) with a conventional radioimmunoassay.  相似文献   

20.
Production of monoclonal antibodies against human chorionic gonadotropin (hCG) has been studied using hCG as an immunogen. Spleen cells of BALB/c mice immunized with hCG were fused with NS-1 mouse myeloma cells. This study reports the successful isolation of a hybrid clone secreting a monoclonal antibody specific for hCG. By using PEG 4,000 as a fusion agent, the fusion rates were between 42.0 and 50.2%. In total 842 hybridomas were produced. Among them, 403 hybridomas had hCG antibody production. After cloning twice by limiting dilution and alternately screening by enzyme immunoassay and by radioimmunoassay, there were 39 cell lines having specific antibody production. Among them, the No. 57-42-2 had the highest reactivity. By Ouchterlony test, the monoclonal antibody was shown to be IgG1. The affinity constant of the antibody to hCG was 0.6 x 10(9) 1/mole. In radioimmunoassay, the cross reactivity of the antibody to human luteinizing hormone (LH) and human follicle-stimulating hormone (FSH) was 1.5% and 0.7%, respectively. There was no cross reaction with human thyrotropin-stimulating hormone (TSH).  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司    京ICP备09084417号-23