1.
An experimental energy storage system has been designed using a horizontal concentric tube heat exchanger incorporating a medium temperature phase change material (PCM) Erythritol, with a melting point of 117.7 °C. Three experimental configurations, a control system with no heat transfer enhancement and systems augmented with circular and longitudinal fins have been studied. The results presented compare the system heat transfer characteristics using isotherm plots and temperature-time curves. The system with longitudinal fins gave the best performance with increased thermal response during charging and reduced subcooling in the melt during discharging. The experimentally measured data for the control, circular finned and longitudinal finned systems have been shown to vindicate the assumption of axissymmetry (direction parallel to the heat transfer fluid flow) using temperature gradients in the axial, radial and angular directions in the double pipe PCM system.  相似文献   

2.
An experimental analysis is presented to establish the thermal performance of a latent heat thermal storage (LHTS) unit. Paraffin is used as the phase change material (PCM) on the shell side of the shell and tube‐type LHTS unit while water is used as the heat transfer fluid (HTF) flowing through the inner tube. The fluid inlet temperature and the mass flow rate of HTF are varied and the temperature distribution of paraffin in the shell side is measured along the radial and axial direction during melting and solidification process. The total melting time is established for different mass flow rates and fluid inlet temperature of HTF. The motion of the solid–liquid interface of the PCM with time along axial and radial direction of the test unit is critically evaluated. The experimental results indicate that the melting front moves from top to bottom along the axial direction while the solidification front moves only in the radial direction. The total melting time of PCM increases as the mass flow rate and inlet temperature of HTF decreases. A correlation is proposed for the dimensionless melting time in terms of Reynolds number and Stefan number of HTF. © 2013 Wiley Periodicals, Inc. Heat Trans Asian Res; Published online in Wiley Online Library ( wileyonlinelibrary.com/journal/htj ). DOI 10.1002/htj.21120  相似文献   

3.
Anica Trp   《Solar Energy》2005,79(6):648-660
The latent thermal energy storage system of the shell-and-tube type during charging and discharging has been analysed in this paper. An experimental and numerical investigation of transient forced convective heat transfer between the heat transfer fluid (HTF) with moderate Prandtl numbers and the tube wall, heat conduction through the wall and solid–liquid phase change of the phase change material (PCM), based on the enthalpy formulation, has been presented. A fully implicit two-dimensional control volume Fortran computer code, with algorithm for non-isothermal phase transition, has been developed for the solution of the corresponding mathematical model. The comparison between numerical predictions and experimental data shows good agreement for both paraffin non-isothermal melting and isothermal solidification. In order to provide guidelines for system performance and design optimisation, unsteady temperature distributions of the HTF, tube wall and the PCM have been obtained by a series of numerical calculations for various HTF working conditions and various geometric parameters, and the thermal behaviour of the latent thermal energy storage unit during charging and discharging has been simulated.  相似文献   

4.
The thermal performance and phase change stability of stearic acid as a latent heat energy storage material has been studied experimentally. The thermal performance and heat transfer characteristics of the stearic acid were tested and compared with other studies given in the literature. In the present study, parameters such as transition times, temperature range and propagation of the solid–liquid interface as well as the effect of the heat flow rate on the phase change stability of stearic acid as a phase change material (PCM) were studied. The experimental results showed that the melting stability of the PCM is better in the radial direction than in the axial direction. The variation in the melting and solidification parameters of the PCM with the change of inlet water temperature is also studied. We observed that while the heat exchanger tube is in the horizontal position, the PCM has more effective and steady phase change characteristics than in the vertical position. The heat storage capacity of the container (PCM tube) is not as good as we expected in this study and the average heat storage efficiency (or heat exchanger effectiveness) is 50.3%. This indicates that 49.7% of the heat is actually lost somewhere.  相似文献   

5.
Thermal performance and phase change stability of myristic acid as a latent heat energy storage material has been studied experimentally. In the experimental study, the thermal performance and heat transfer characteristics of the myristic acid were tested and compared with other studies given in the literature. In the present study is included some parameters such as transition times, temperature range, and propagation of the solid–liquid interface as well as heat flow rate effect on the phase change stability of myristic acid as a phase change material (PCM). The experimental results showed that the melting stability of the PCM is better in the radial direction than the axial direction. The variety of the melting and solidification parameters of the PCM with the change of inlet water temperature is also studied. The results show that the better stability of the myristic acid was accomplished at low inlet water temperature compared with the obtained results at high inlet water temperature. We also observed that while the heat exchanger tube is in the horizontal position, the PCM has more effective and steady phase change characteristics than in the vertical position. The heat storage capacity of the container (PCM tube) is not as good as we expected in this study and the average heat storage efficiency (or heat exchanger effectiveness) is 54%. It means that 46% of the heat acrually lost somewhere.  相似文献   

6.
The thermal and heat transfer characteristics of lauric acid during the melting and solidification processes were determined experimentally in a vertical double pipe energy storage system. In this study, three important subjects were addressed. The first one is temperature distributions and temporal temperature variations in the radial and axial distances in the phase change material (PCM) during phase change processes. The second one is the thermal characteristics of the lauric acid, which include total melting and total solidification times, the nature of heat transfer in melted and solidified PCM and the effect of Reynolds and Stefan numbers as inlet heat transfer fluid (HTF) conditions on the phase transition parameters. The final one is to calculate the heat transfer coefficient and the heat flow rate and also discuss the role of Reynolds and Stefan numbers on the heat transfer parameters. The experimental results proved that the PCM melts and solidifies congruently, and the melting and solidification front moved from the outer wall of the HTF pipe (HTFP) to the inner wall of the PCM container in radial distances as the melting front moved from the top to the bottom of the PCM container in axial distances. However, it was difficult to establish the solidification proceeding at the axial distances in the PCM. Though natural convection in the liquid phase played a dominant role during the melting process due to buoyancy effects, the solidification process was controlled by conduction heat transfer, and it was slowed by the conduction thermal resistance through the solidified layer. The results also indicated that the average heat transfer coefficient and the heat flow rate were affected by varying the Reynolds and Stefan numbers more during the melting process than during the solidification process due to the natural convection effect during the melting process.  相似文献   

7.
A numerical and experimental investigation of phase change process dominated by heat conduction in a thermal storage unit is presented in this paper. The thermal energy storage involves a shell and tube arrangement where paraffin wax as phase change material (PCM) is filled in the shell. Water as heat transfer fluid (HTF) is passed inside the tube for both charging and discharging cycles. According to the conservation of energy, a simple numerical method called alternative iteration between thermal resistance and temperature has been developed for the analysis of heat transfer between the PCM and HTF during charging and discharging cycles. Experimental arrangement has been designed and built to examine the physical validity of the numerical results. Comparison between the numerical predictions and the experimental data shows a good agreement. A detailed parametric study is also carried out for various flow parameters and system dimensions such as different mass flow rates, inlet temperatures of HTF, tube thicknesses and radii. Numerical study reveals that the contribution of the inlet temperature of HTF has much influence than mass flow rate in terms of storage operating time and HTF outlet temperature. Tube radius is a more important parameter than thickness for better heat transfer between HTF and PCM.  相似文献   

8.
Long Jian-you 《Solar Energy》2008,82(11):977-985
This paper addresses a numerical and experimental investigation of a thermal energy storage unit involving phase change process dominated by heat conduction. The thermal energy storage unit involves a triplex concentric tube with phase change material (PCM) filling in the middle channel, with hot heat transfer fluid (HHTF) flowing outer channel during charging process and cold heat transfer fluid (CHTF) flowing inner channel during discharging process. A simple numerical method according to conversation of energy, called temperature & thermal resistance iteration method has been developed for the analysis of PCM solidification and melting in the triplex concentric tube. To test the physical validity of the numerical results, an experimental apparatus has been designed and built by which the effect of the inlet temperature and the flow rate of heat transfer fluid (HTF, including HHTF and CHTF) on the thermal energy storage has been studied. Comparison between the numerical predictions and the experimental data shows good agreement. Graphical results including fluid temperature and interface of solid and liquid phase of PCM versus time and axial position, time-wise variation of energy stored/released by the system were presented and discussed.  相似文献   

9.
The heat transfer characteristics of a low temperature latent heat storage system have been determined for circular finned and unfinned tubes using sodium acetate trihydrate as a phase change material (PCM). In the heat recovery stage, supercooling of PCM in the finned-tube system is larger than that in the unfinned-tube system. The heat-transfer coefficient between the PCM and the heat-transfer tube surface can be predicted from the steady-state heat conduction equation except the beginning of freezing with some degree of supercooling. The heat transfer is significantly reduced by the void cavities upon shrinkage of PCM in the finned-tube system. The enhancement of heat transfer by thin finned-tube over the unfinned-tube is found to be negligible. The heat-transfer coefficient in the thick finned-tube system is approximately two times higher than that in the unfinned-tube system. The heat transfer coefficients for the unfinned-tube and thick finned-tube systems are found to be 45 150 W/m2-K and 90 250 W/m2-K, respectively. The thermal performance for three different tube systems is found to be strongly affected by the inlet temperature but not by the flow rate of the heat transfer fluid. The amount of heat recovered has been correlated in terms of the Fourier, Stefan, and Reynolds numbers.  相似文献   

10.
The present paper addresses an experimental investigation of the cold storage with liquid/solid phase change of water based on the cold energy recovery of Liquefied Natural Gas (LNG) refrigerated vehicles. Water as phase change material (PCM) was solidified outside the heat transfer tubes that were internally cooled by cryogenic nitrogen gas substituting cryogenic natural gas. The ice layer profiles were recorded in different cross-sections observed by digital cameras. The temperatures of cryogenic gas, tube wall and bulk region were measured by embedded thermocouples continuously. The results of the smooth tube experiments and the thermal resistance analysis prove that the main thermal resistance occurs in the gaseous heat transfer fluid (HTF) inner the tube. The enhancement of the inner heat transfer is achieved by adding wave-like internal fins. Besides, the results show that the ice layer not only increases in radial direction but also propagates in axial direction. It distributes in parabolic shape along the tube length due to the parabolic axial distribution of the tube wall temperatures. This investigation provides valuable references for the design and optimization of the cold energy storage unit of LNG refrigerated vehicles and for the numerical study on the unsteady two-dimensional conjugated heat transfer with phase change.  相似文献   

11.
基于焓法模型对水平管壳式相变蓄热装置热性能的增强进行研究,首先分析蓄热过程中传统管壳式装置内材料的传热及流动机理;然后引入椭圆元素并对比椭圆内管及外壳的强化传热效果;最后对热源温度、相变材料导热系数及初始温度对装置热性能的作用规律进行探讨。结果显示,椭圆外壳的强化传热效果优于内管,同等条件下,长短轴之比为2的椭圆外壳可使蓄热时间缩短53.5%。热源温度升高,椭圆外壳的强化传热效果进一步增强,相变材料的导热系数及初始温度对装置热性能的影响较小。  相似文献   

12.
A preliminary model for estimating possible thermal energy storage in a phase change shell and tube heat exchanger is presented. Effect of various parameters such as thermal and physical properties of PCM and convective fluid, heat exchanger dimensions and heat transfer fluid flow rates both in laminar and turbulent regime on energy storage times are discussed. The model is illustrated for specific cases.  相似文献   

13.
A latent heat thermal energy storage system using a phase change material (PCM) is an efficient way of storing or releasing a large amount of heat during melting or solidification. It has been determined that the shell‐and‐tube type heat exchanger is the most promising device as a latent heat system that requires high efficiency for a minimum volume. In this type of heat exchanger, the PCM fills the annular shell space around the finned tube while the heat transfer fluid flows within the tube. One of the methods used for increasing the rate of energy storage is to increase the heat transfer surface area by employing finned surfaces. In this study, energy storage by phase change around a radially finned tube is investigated numerically and experimentally. The solution of the system consists of the solving governing equations for the heat transfer fluid (HTF), pipe wall and phase change material. Numerical simulations are performed to investigate the effect of several fin parameters (fin spacing and fin diameter) and flow parameter (Re number and inlet temperature of HTF) and compare with experimental results. The effect of each variable on energy storage and amount of solidification are presented graphically. Copyright © 2005 John Wiley & Sons, Ltd.  相似文献   

14.

Thermal energy storage performance of fatty acids and a eutectic mixture as phase change materials (PCMs) has been investigated experimentally. The selected PCMs for this study were palmitic acid, myristic acid, stearic acid, and a mixture of stearic and myristic acids in eutectic combination ratio of 65.7 wt% myristic acid and 34.3 wt% stearic acid. The PCMs have a melting temperature range of 50.0°C to 61.20°C and a latent heat range of 162.0 J/g to 204.5 J/g. The inlet temperature and the mass flow rate of heat transfer fluid (HTF) were selected as experimental parameters to test the thermal energy storage performance of the PCMs. The transition times, temperature range, propagation of the solid-liquid interface, as well as heat flow rate characteristics of the employed cylindrical tube storage system were studied at varied experimental parameters. The experimental results show that the melting front moves to inward in the radial directions as well as in the axial directions from the top toward to the bottom of the PCM tube. It was observed that the convection heat transfer in the liquid phase plays an important role in the melting process. The changes in the studied HTF parameters have more effect on the melting processes than the solidification processes of the PCMs. The average heat storage efficiency calculated from data for all the PCMs is 51.5%, meaning that 48.5% of the heat actually was lost somewhere.  相似文献   

15.
《Energy》2002,27(9):869-888
The mixture of capric acid and lauric acid (C-L acid), with the respective mole composition of 65% and 35%, is a potential phase change material (PCM). Its melting point of 18.0°C, however, is considered high for cooling application of thermal energy storage. The thermophysical and heat transfer characteristics of the C-L acid with some organic additives are investigated. Compatibility of C-L acid combinations with additives in different proportions and their melting characteristics are analyzed using the differential scanning calorimeter (DSC). Among the chemical additives, methyl salicylate, eugenol, and cineole presented the relevant melting characteristics. The individual heat transfer behavior and thermal storage performance of 0.1 mole fraction of these additives in the C-L acid mixture are evaluated. The radial and axial temperature distribution during charging and discharging at different concentrations of selected PCM combinations are experimentally determined employing a vertical cylindrical shell and tube heat exchanger. The methyl salicylate in theC-L acid provided the most effective additive in the C-L acid. It demonstrated the least melting band width aimed at lowering the melting point of the C-L acid with the highest heat of fusion value with relatively comparable rate of heat transfer. Furthermore, the thermal performance based on the total amount of transferred energy and their rates, established the PCM’s latent heat storage capability.  相似文献   

16.
In this study, convective heat transfer of Al2O3-water nanofluids (NFs) of various concentrations under laminar flow in a horizontal circular tube with and without considering particle aggregation was numerically investigated by a combined nanoparticle diameter distribution model (NDDM) with the Discrete Phase Model (DPM). Heat transfer coefficient (h), temperature distribution in axial and radial direction, and pressure drop (ΔP) were studied. It turns out that beside a slight pressure drop, heat transfer near the wall will significantly deteriorate when particle aggregation occurs. With an increase in Re numbers, the effects of particle aggregation on the heat transfer performance of the fluid will decrease.  相似文献   

17.
A theoretical model was developed to predict the transient behavior of a shell-and-tube storage unit with the phase change material (PCM) on the shell side and the heat transfer fluid (HTF) circulating inside the tubes. The multidimensional phase change problem is tackled with an enthalpy-based method coupled to the convective heat transfer from the HTF. The numerical predictions are validated with experimental data. A series of numerical experiments are then undertaken to assess the effects of various thermal and geometric parameters on the heat transfer process and on the behavior of the system. Results show that the shell radius, the mass flow rate, and the inlet temperature of the HTF must be chosen carefully in order to optimize the performance of the unit.  相似文献   

18.
为探究相变温度对相变材料回填地埋管换热器传热性能的影响,建立管内流体换热、回填区域相变换热及土壤换热的三维耦合传热数值模型,利用焓-多孔介质模型对相变区域相变问题进行处理,研究夏季间歇运行工况下不同相变温度回填材料对埋管换热器传热性能的影响。结果表明:添加PCM,可有效提高换热量,短期内缓解埋管周围热积聚,利用相变温度18℃的PCM回填,单位井深换热量至少比普通材料回填提高49.54%;在间歇运行初期,换热量随相变温度的升高逐渐减小,低相变温度的PCM可明显改善埋管换热量,但随着时间的进行,较高相变温度PCM回填对换热器换热量的改善效果优于前期低相变温度。此外,在运行期间,不同相变温度的PCM表现出不同的熔化、凝固特性,当PCM的熔化、凝固过程交替进行时,可减缓土壤温度在运行期间内波动幅度。  相似文献   

19.
相变蓄热技术近年来在电力削峰填谷的应用中发挥了重要作用,成为供热领域的新热点。本文设计了以PTC电加热棒为发热源,水为载热介质,纳米共晶水合盐为相变蓄热材料的管壳式相变蓄热器。实验研究了蓄放热过程中装置内部水和相变材料的温度分布情况以及特定温度范围的蓄放热性能及变化规律。结果表明,以圆管正三角阵列 + 折流板为特征的管壳式换热器结构可以使蓄热器内部温度分布更加均匀;以某测温点水温75 ~ 98℃变化区间为蓄放热周期,蓄热周期的实际蓄热量为779 796 kJ,有效蓄热系数达到0.91,平均蓄热功率为94.13 kW;在放热周期,放热功率从74.2 kW随水温的下降而逐渐减小至51.8 kW,当水温降至相变温度以下时,放热功率趋于稳定。  相似文献   

20.
IlltroductionSolar dynamic power modules (SDPM) with phasechange material (PCM) is a vital solution to ensureuninterrupted power supply for low-earth orbitapplication. The advantage of SDPM is its longerlifehme and higher efficiency. Longer lifetime results insubstanhal savings in hardware replacement, launch, andon-orbit installation costs. Because of SDPM's higherefficiency, its solar collection area is only about 25percent of that for a PV system. This would allowspacecraft operatin…  相似文献   