首页 | 官方网站   微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 187 毫秒
1.
This paper proposes a mathematical model to predict the frost properties and heat and mass transfer within the frost layer formed on a cold plate. Laminar flow equations for moist air and empirical correlations for local frost properties are employed to predict the frost layer growth. Correlations for local frost density and effective thermal conductivity of the frost layer, derived from various experimental data, are expressed as a function of the various frosting parameters: the Reynolds number, frost surface temperature, absolute humidity and temperature of the moist air, cooling plate temperature, and frost density. The numerical results are compared with experimental data to validate the proposed model, and those agree well with the experimental data within a maximum error of 10%. Heat and mass transfer coefficients obtained from the numerical analyses are also presented. The results show that the model for the frost growth using the correlation of the heat transfer coefficient without considering the air flow has a limitation in its application.  相似文献   

2.
Airside heat and mass transfer and fluid flow characteristics of a wavy-finned-tube direct expansion air coil under cooling and dehumidifying condition have been experimentally investigated. Experiments were carried out to study the effects of operating conditions such as: air temperature, air relative humidity, air face velocity, and evaporator pressure on the airside performance (cooling capacity, dehumidification capacity, pressure drop, and heat transfer coefficient) of the coil. Charts for coil wet conditions, partially wet or totally wet, were conducted to identify the coil wet conditions in terms of the operating conditions. Two techniques, enthalpy potential method and equivalent dry-bulb temperature method, were used to analyze the data and to deduce correlations for Colburn factors for the different coil wet conditions. Comparison between the correlations predictions of the two techniques was presented.  相似文献   

3.
Storage loss beyond permissible limit is one of the most important problems in Indian potato cold stores, which has been hindering further growth of this industry. The losses in the stored potatoes have a direct relation to the intricate coupled transport phenomena of heat, mass and momentum transfer therein. Therefore, airflow, heat transfer and moisture loss was investigated in a potato cold store of commercial scale under steady state condition using the computational fluid dynamics technique. The developed CFD model was a two-dimensional simplification of the cold store. Heat and mass transfer at the cooling coils were not modeled, instead temperature and relative humidity in the air space were specified based on measured values. The model was validated in a commercial scale cold store and was found to be capable of predicting the air velocity as well as product temperature with an average accuracy of 19.5% and 0.5 °C, respectively and also the simulated average total moisture loss was found to be only 0.61% water (w.b.) higher than the experimental one for a storage period of 6 months. The main deficiencies of the airflow pattern which resulted in wide variations in temperature and moisture loss within the stored commodity can be investigated. The model located the probable zones of hot and cold spots, excessive product dehydration and moisture condensation within the storage facility, which might lead to qualitative and quantitative deterioration in stored product. This modeling tool could very well be applied to incorporate necessary design improvements with a view to improve the airflow distribution and heat transfer in order to limit the storage losses within the permissible limit.  相似文献   

4.
Evaporative cooling is used in industrial and air conditioning processes to reduce temperature in different fluids. Direct evaporation systems can lead to environmental problems such as Legionnaire's disease, and indirect systems reduce system efficiency.This work presents the manufacture, test bed set up and trials carried out on a ceramic evaporative cooling system which acts as a semi-indirect cooler. Depending on air characteristics, it may act as a sensible or enthalpic exchanger. The water cooled in a cooling tower, using the return air coming from the conditioned room (22 °C and 50% comfort conditions) goes through the ceramic pipes, exchanging sensible and latent heat with a current of outdoor air.The use of this recovery system is mainly in climates with a high temperature and humidity such as tropical environments where the system yields a decrease in supply air humidity, using the cooling power of return air.The tests presented show the system behaviour for various supply air conditions.  相似文献   

5.
For providing good performance of dehumidifier and regenerator with certain dimensions, a new type of internally cooled/heated dehumidifier/regenerator based on the plate–fin heat exchanger (PFHE) was designed. To investigate the behavior of the new equipment, an experimental setup was established in an environment chamber with regulable temperature and humidity air. By the internally cooled dehumidification testing, effects of the cooling water temperature, the air flow rate and the desiccant temperature on the dehumidification performance and the cooling efficiency were presented. The behavior of internally cooled dehumidification process was compared with that of the adiabatic dehumidification process. The results suggested that the cooling efficiency decreased with the increasing of the cooling water temperature and desiccant with low temperature could bring more mass transfer coefficients. There is an optimal air flow rate to achieve the maximum absolute humidity decrease of the air. By the internally heated regeneration testing, effects of the air flow rate and the desiccant inlet temperature on the regeneration performance and air outlet parameters were discussed and also compared with those of the adiabatic regeneration process. It was concluded that the regeneration efficiency of internally heated regeneration was more than that of the adiabatic regeneration, and the internally heated regenerator could offer better thermal performance.  相似文献   

6.
The effect of air inlet humidity condition on the air-side heat transfer and pressure drop characteristics for an inclined brazed aluminum heat exchanger has been investigated experimentally. For a heat exchanger with a louver angle of 27°, fin pitch of 2.1 mm and flow depth of 27.9 mm, a series of tests are conducted for the air-side Reynolds numbers of 80–400, with variation of inlet humidity condition. The heat transfer data are obtained for wet condition only and the pressure drop data are measured for both dry and wet conditions. The inlet air temperature and relative humidity range are 12 °C and 60–90%, respectively. The inclination angles (θ) from the vertical position are 0, 14, 45, and 67° clockwise (leeward direction). The inclination angles affect moderately the sensible heat transfer coefficient for wet condition, and the pressure drops for both dry and wet conditions increase systematically with the inclination angle. The heat transfer and pressure drop characteristics under wet condition are not influenced substantially by the air inlet humidity for θ 45°. The effect of the louver directions at the inlet and outlet of the inclined heat exchanger on the performance is also addressed.  相似文献   

7.
This study proposes dimensionless correlations for predicting the properties of frost formed on a cold plate. Frosting experiments are carried out to obtain the correlations with various environmental parameters including the air temperature, air velocity, absolute humidity, and cooling plate temperature. The thickness, density, surface temperature, effective thermal conductivity, average heat and mass transfer coefficients of the frost layer are correlated as functions of the Reynolds number, Fourier number, absolute humidity, and dimensionless temperature by using a dimensional analysis. The correlations proposed in this study agree well with the experimental data within a maximum error of 10%, and can be used to predict the average frost properties in the following ranges: the air temperature of 5–15 °C, air velocity of 1.0–2.5 m s−1, absolute humidity of 0.00322–0.00847 kg kga−1, and cooling plate temperature of −35–−15 °C.  相似文献   

8.
The spray drying process consists of a fast convective drying of liquid droplets by hot air. Initially, the water activity (aw) of a drop is close to 1. During drying, the drop surface aw decreases while viscosity increases until reaching a sticky rubbery state before further drying. This can be observed for products such as carbohydrates, leading to particles sticking on walls (product losses) or to adhesion between particles leading to agglomeration. In this study, particle stickiness was investigated in a cocurrent pilot spray dryer by measuring drying air properties (temperature and relative humidity) at different positions. This allowed describing the evolution of temperature and mean water content of the drying drops. Two model products (maltodextrin DE12 and DE21) were spray dried varying process parameters liquid flow rate (1.8, 3.6, and 5.4 kg/h), air temperature (144°, 174°, and 200°C), airflow rate (80–110 kg/h), and rotary atomizer speed (22,500–30,000 rpm). The two products exhibit different drying behaviors in relation to their affinity towards water (sorption isotherms) and glass transition temperature evolution with aw (stickiness). Depending on drying conditions and product, the drop stickiness was observed very rapidly, close to the atomizer, or later, along the chamber. This approach can be used to identify conditions and positions corresponding to sticky particles.  相似文献   

9.
Effects of fin height and helix angle on condensation inside a herringbone microfin tube have been experimentally investigated with five types of herringbone microfin tubes. Heat transfer coefficients are about 2–4 times higher than that of the helical microfin tube under high mass velocity conditions. In the low mass velocity, they are equal to that of the helical microfin tube. The heat transfer enhancement increases with fin height up to 0.18 mm; higher fin heights show enhancement values similar to the 0.18 mm results. Pressure drop increases with the fin height. Larger helix angle yields higher heat transfer and higher pressure drop. For the lowest fin and/or smallest helix angle, the pressure drop is comparable with that of the helical microfin tube, while the heat transfer enhancement is higher. The enhancement mechanism is discussed from flow pattern observations. Effect of mass transfer resistance for R410A is estimated and negligible effects have been proved.  相似文献   

10.
Hot gas defrost model development and validation   总被引:5,自引:0,他引:5  
This paper describes the development, validation, and application of a transient model for predicting the heat and mass transfer effects associated with an industrial air-cooling evaporator during a hot gas defrost cycle. The inputs to the model include the space dry bulb temperature, space humidity, coil geometry, frost thickness, frost density, and hot gas inlet temperature. The model predicts the time required for a complete frost melt as well as the sensible and latent loads transferred back to the conditioned space during the defrost period. The model is validated by comparing predicted results to actual defrost cycle field measurements and to results presented in previously published studies.A unique contribution of the present model is its ability to estimate parasitic space loads generated during a defrost cycle. The parasitic energy associated with the defrost process includes thermal convection, moisture re-evaporation, and extraction of the stored energy in the coil mass following a defrost cycle. Each of these factors contribute to the parasitic load on compressors connected to the defrost return. The results from the model provide quantitative information on evaporator operation during a defrost cycle which forms the basis to improve the energy efficiency of the defrost process.  相似文献   

11.
In sub-tropical regions, a standard water cooling tower may be reversibly used, as part of a desuperheater heat recovery system for service hot water heating, to extract free heat from ambient air in colder seasons when building cooling load is reduced. Chilled water is pumped into a reversibly used water cooling tower (RUWCT) where it is heated by warmer ambient moist air. This paper presents a method by which the heat and mass transfer characteristics in a counter-flow RUWCT can be evaluated. The method is developed by introducing to the Merkel's equation for standard water cooling towers the revisions that account for the differences in heat and mass transfer characteristics between a water cooling tower and a RUWCT. Field experimental results from a RUWCT installed in a sub-tropical region in China indicated that the method developed could be used to evaluate the thermal performance of a RUWCT with an acceptable accuracy.  相似文献   

12.
Study on ice slurry production by water spray   总被引:2,自引:0,他引:2  
A theoretical and experimental study was performed to examine the water spray method of ice slurry production. First, the conditions for the formation of ice particles were investigated theoretically by the diffusion-controlled evaporation model. The prediction of the model was proved to agree relatively well with experiments in which we examined the conditions for a droplet of initial temperature 20°C and size 50 μm to change into an ice particle in a chamber of height 1.33 m. Second, the production of cold storage heat will increase almost proportionally to the number of spray nozzles because no substantial difference was found in the Sauter Mean Diameter (SMD) of sprays from single and twin nozzle. Third, an ice slurry was experimentally obtained by spraying droplets of 7% ethylene glycol aqueous solution in a vacuum chamber where pressure is maintained below the freezing point of the solution. Finally, based on the theoretical and experimental results, we propose an optimizing chart for providing the operating conditions to make ice slurry using the relations of the staying time of the droplet in the chamber, the injection pressure, the spray droplet size and the chamber pressure.  相似文献   

13.
We considered mass and heat transfer during nonisothermal absorption of a gas by a falling droplet with internal circulation. Gas phase is assumed to be free of inert admixtures and mass transfer is liquid phase controlled. Mass flux is directed from a gaseous phase to a droplet, and the interfacial shear stress causes a fluid flow inside the droplet. Droplet deformation under the influence of interface shear stress is neglected. Absorbate accumulation and temperature increase in the bulk of liquid phase are taken into account. The problem is solved in the approximations of a thin concentration and temperature boundary layers in the liquid phase. The thermodynamic parameters of the system are assumed constant. The system of transient partial parabolic differential equations of convective diffusion and energy balance with time-dependent boundary conditions is solved by combining the similarity transformation method with Duhamel's theorem, and the solution is obtained in a form of Volterra integral equation of the second kind which is solved numerically. Theoretical results are compared with available experimental data for water vapor absorption by falling droplets of aqueous solution of LiBr.  相似文献   

14.
In this paper a semi-empirical model describing heat and mass transfer on a cold surface in humid air under supersaturated frosting conditions is presented. The lack of psychrometric data in the supersaturated zone of the psychrometric chart has historically impeded the ability of researchers to accurately predict heat and mass transfer in supersaturated air. The work described in this paper has been partially made possible by developing a systematic procedure to compute the properties of supersaturated air, especially in the low temperature zone of the psychrometric chart. Development of such a capability will allow us to predict the amount of frost collected, the frost deposition and heat transfer rates, frost thickness and surface temperature, and other important parameters.  相似文献   

15.
The unsteady heat and mass transfer process during beef carcass chilling was modelled for a three-dimensional beef carcass geometry. A three-step method was used to simulate the simultaneous heat and mass transfer process in order to reduce the computational time. In the first step, a steady state simulation of the flow field was conducted. In the second step, the local heat and mass transfer coefficients were calculated. Finally, the third step consists of the simultaneous heat and mass transfer process simulation on the meat carcass only. A separate 1-D grid was used to calculate the moisture diffusion in the meat. The simulation of a 20-h chilling run takes 5 days on a 2.5 GHz Pentium 4 computer. The model allows calculating and predicting the heat load, temperatures, weight loss and water activity. Local variations in the heat and mass transfer coefficients, temperature and water activity were found around the beef carcass. The CFD model gives temperature predictions that agree with experimental data better than any previous model. The weight loss tends to be over-predicted probably due to neglecting the resistance caused by the fat cover.  相似文献   

16.
This paper reports an experimental investigation of convective boiling heat transfer and pressure drop of refrigerant R-134a in smooth, standard microfin and herringbone copper tubes of 9.52 mm external diameter. Tests have been conducted under the following conditions: inlet saturation temperature of 5 °C, qualities from 5 to 90%, mass velocity from 100 to 500 kg s−1 m−2, and a heat flux of 5 kW m−2. Experimental results indicate that the herringbone tube has a distinct heat transfer performance over the mass velocity range considered in the present study. Thermal performance of the herringbone tube has been found better than that of the standard microfin in the high range of mass velocities, and worst for the smallest mass velocity (G=100 kg s−1 m−2) at qualities higher than 50%. The herringbone tube pressure drop is higher than that of the standard microfin tube over the whole range of mass velocities and qualities. The enhancement parameter is higher than one for both tubes for mass velocities lower than 200 kg s−1 m−2. Values lower than one have been obtained for both tubes in the mass velocity upper range as a result of a significant pressure drop increment not followed by a correspondent increment in the heat transfer coefficient.  相似文献   

17.
A coupled heat and mass transfer model is developed to extract the transfer coefficients for falling-films from the measurements on a tubular absorber. The mass transfer coefficients obtained from the coupled model and the log-mean-difference approach agree within about 10%. For the heat transfer coefficient, the values given by the two models can differ quite significantly. The cooling water temperature distribution predicted by the coupled model agrees well with measurements. The transfer coefficients obtained from experimental measurements using the various methods reported in the literature show wide variations.  相似文献   

18.
The heat transfer coefficient and pressure drop during gas cooling process of CO2 (R744) in a horizontal tube were investigated experimentally. The experiments are conducted without oil in the refrigerant loop. The main components of the refrigerant loop are a receiver, a variable-speed pump, a mass flow meter, a pre-heater and a gas cooler (test section). The water loop consists of a variable speed pump, an isothermal tank, and a flow meter. The refrigerant, circulated by the variable-speed pump, condenses in the inner tube while water flows in the annulus. The gas cooler of tube diameter is 6000 mm in length, and it is divided into 12 subsections.The pressure drop of CO2 in the gas cooler shows a relatively good agreement with those predicted by Blasius's correlation. The local heat transfer coefficient of CO2 agrees well with the correlation by Bringer–Smith. However, at the region near Pseudo-critical temperature, the experiments indicate higher values than the Bringer–Smith correlation. Based on the experimental data presented in this paper, a new correlation to predict the heat transfer coefficient of supercritical CO2 during in-tube cooling has been developed. The majority of the experimental values are within 18% of the values predicted by the new correlation.  相似文献   

19.
In the present work, the spray absorption method is studied for the absorption of ammonia refrigerant vapour by lithium nitrate–ammonia solutions. Mass transfer coefficients attainable using the spray absorption method are estimated. In this study the low-pressure absorber of a double-stage absorption refrigeration system is considered. Results show that the mass transferred is maximum (about 60% of the total) during the deceleration period of the drops. This period represents about 13.4% of the time required to reach the equilibrium state at the end of the absorption chamber. The results show that a time-average mass transfer coefficient equal to km=18.6×10−5 m s−1 may be attained.  相似文献   

20.
A plate-type evaporator, working with natural refrigerant circulation, has been investigated both experimentally and theoretically. Motivated by the phase-out of ozone-depleting substances, HCFC22 was compared to HFC134a and two zeotropic refrigerant mixtures. The effect of different separator liquid levels, i.e. refrigerant flows, and its influence on heat transfer was also studied. The investigated plate-type evaporator consists of thirteen vertical flow channels and its size is 3.0 m × 0.5 m. The heat source for the evaporator is a falling water film on the outside of the plate. Experimental studies have been carried out using a test facility that enabled detailed measurements of heat transfer and pressure drop. Experiments were compared to results from a calculation method that simultaneously calculates heat transfer and pressure drop in a variable number of steps along the evaporator. The calculation method is based on a pressure drop correlation proposed by the VDI-Wärmeatlas and a heat transfer correlation for vertical tubes proposed by Steiner and Taborek. For different evaporator duties, heat transfer was over predicted by 12% for pure fluids by 15% for mixtures. Calculated pressure drops were well within ±5% of the measured values. Changes in heat transfer due to different flows were closely predicted by the proposed calculation method.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司    京ICP备09084417号-23

京公网安备 11010802026262号