首页 | 官方网站   微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 0 毫秒
1.
N. Naeeni  M. Yaghoubi   《Renewable Energy》2007,32(11):1898-1916
Applications of parabolic collectors for solar heating and solar thermal power plant increased in the recent years. Most of the solar power plants installed with parabolic collectors are on flat terrain and they may be subjected to some environmental problems. One of problems for large parabolic collector is their stability to track the sun with respect to time very accurately. Any small off tracking as well as the collector structure stability will be affected by strong wind blowing for the regions where the wind velocity is high.In the present study, a two-dimensional numerical simulation of turbulent flow around a parabolic trough collector of the 250 kW solar power plants in Shiraz, Iran is performed taking into account the effects of variation of collector angle of attack, wind velocity and its distribution with respect to height from the ground.Computation is carried for wind velocity of 2.5, 5, 10, and 15 m/s and collector angles of 90°, 60°, 30°, 0°, −30°, −60°, and −90° with respect to wind directions. Various recirculation regions on the leeward and forward sides of the collector are observed, and both pressure field around the collector and total force on the collector are determined for each condition. The effect of absorber tube on the flow field was found negligible, while the effect of the gap between the two sections of parabola at midsection and the gap between the collector and ground were found considerable on both flow field and pressure distribution around the collector.  相似文献   

2.
The solar energy flux distribution on the outer wall of the inner absorber tube of a parabolic solar collector receiver is calculated successfully by adopting the Monte Carlo Ray-Trace Method (MCRT Method). It is revealed that the non-uniformity of the solar energy flux distribution is very large. Three-dimensional numerical simulation of coupled heat transfer characteristics in the receiver tube is calculated and analyzed by combining the MCRT Method and the FLUENT software, in which the heat transfer fluid and physical model are Syltherm 800 liquid oil and LS2 parabolic solar collector from the testing experiment of Dudley et al., respectively. Temperature-dependent properties of the oil and thermal radiation between the inner absorber tube and the outer glass cover tube are also taken into account. Comparing with test results from three typical testing conditions, the average difference is within 2%. And then the mechanism of the coupled heat transfer in the receiver tube is further studied.  相似文献   

3.
Y.B. Tao 《Solar Energy》2010,84(10):1863-1872
A unified two-dimensional numerical model was developed for the coupled heat transfer process in parabolic solar collector tube, which includes nature convection, forced convection, heat conduction and fluid-solid conjugate problem. The effects of Rayleigh number (Ra), tube diameter ratio and thermal conductivity of the tube wall on the heat transfer and fluid flow performance were numerically analyzed. The distributions of flow field, temperature field, local Nu and local temperature gradient were examined. The results show that when Ra is larger than 105, the effects of nature convection must be taken into account. With the increase of tube diameter ratio, the Nusselt number in inner tube (Nu1) increases and the Nusselt number in annuli space (Nu2) decreases. With the increase of tube wall thermal conductivity, Nu1 decreases and Nu2 increases. When thermal conductivity is larger than 200 W/(m K), it would have little effects on Nu and average temperatures. Due to the effect of the nature convection, along the circumferential direction (from top to down), the temperature in the cross-section decreases and the temperature gradient on inner tube surface increases at first. Then, the temperature and temperature gradients would present a converse variation at θ near π. The local Nu on inner tube outer surface increases along circumferential direction until it reaches a maximum value then it decreases again.  相似文献   

4.
Parabolic trough solar collector (PTSC) is one of the most proven technologies for large‐scale solar thermal power generation. Currently, the cost of power generation from PTSC is expensive as compared with conventional power generation. The capital/power generation cost can be reduced by increasing aperture sizes of the collector. However, increase in aperture of the collector leads to higher heat flux on the absorber surface and results in higher thermal gradient. Hence, the analysis of heat distribution from the absorber to heat transfer fluid (HTF) and within the absorber is essential to identify the possibilities of failure of the receiver. In this article, extensive heat transfer analysis (HTA) of the receiver is performed for various aperture diameter of a PTSC using commercially available computational fluid dynamics (CFD) software ANSYS Fluent 19.0. The numerical simulations of the receiver are performed to analyze the temperature distribution around the circumference of the absorber tube as well as along the length of tube, the rate of heat transfer from the absorber tube to the HTF, and heat losses from the receiver for various geometric and operating conditions such as collector aperture diameter, mass flow rate, heat loss coefficient (HLC), HTF, and its inlet temperature. It is observed that temperature gradient around the circumference of the absorber and heat losses from the receiver increases with collector aperture. The temperature gradient around the circumference of the absorber tube wall at 2 m length from the inlet are observed as 11, 37, 48, 74, and 129 K, respectively, for 2.5‐, 5‐, 5.77‐, 7.5‐, and 10‐m aperture diameter of PTSC at mass flow rate of 1.25 kg/s and inlet temperature of 300 K for therminol oil as HTF. To minimize the thermal gradient around the absorber circumference, HTFs with better heat transfer characteristics are explored such as molten salt, liquid sodium, and NaK78. Liquid sodium offers a significant reduction in temperature gradient as compared of other HTFs for all the aperture sizes of the collector. It is found that the temperature gradient around the circumference of the absorber tube wall at a length of 2 m is reduced to 4, 8, 10, 13, and 18 K, respectively, for the above‐mentioned mass flow rate with liquid sodium as HTF. The analyses are also performed for different HTF inlet temperature in order to study the behavior of the receiver. Based on the HTA, it is desired to have larger aperture parabolic trough collector to generate higher temperature from the solar field and reduce the capital cost. To achieve higher temperature and better performance of the receiver, HTF with good thermophysical properties may be preferable to minimize the heat losses and thermal gradient around the circumference of the absorber tube.  相似文献   

5.
Fouling is one of the main problems of heat transfer which can be described as the accumulation on the heat exchanger tubes, i.e.; ash deposits on the heat exchanger unit of the boiler. A decrease in heat transfer rate by this deposition causes loss in system efficiency and leads to increasing in operating and maintenance costs. This problem concerns with the coupling among conduction heat transfer mode between solid of different types, conjugate heat transfer at the interface of solid and fluid, and the conduction/convection heat transfer mode in the fluid which can not be solved analytically. In this paper, fouling effect on heat transfer around a cylinder in cross flow has been studied numerically by using conjugate heat transfer approach. Unlike other numerical techniques in existing literatures, an unstructured control volume finite element method (CVFEM) has been developed in this present work. The study deals with laminar flow where the Reynolds number is limited in the range that the flow field over the cylinder is laminar and steady. We concern the fouling shape as an eccentric annulus with constant thermal properties. The local heat transfer coefficient, temperature distribution and mean heat transfer coefficient along the fouling surface are given for concentric and eccentric cases. From the results, we have found that the heat transfer rate of cross-flow heat exchanger depends on the eccentricity and thermal conductivity ratio between the fouling material and fluid. The effect of eccentric is dominant in the region near the front stagnation point due to high temperature and velocity gradients. The mean Nusselt number varies in asymptotic fashion with the thermal conductivity ratio. Fluid Prandtl number has a prominent effect on the distribution of local Nusselt number and the temperature along the fouling surface.  相似文献   

6.
Hany Al-Ansary  O. Zeitoun 《Solar Energy》2011,85(11):3036-3045
Grid-quality parabolic trough collectors utilize expensive receivers that maintain vacuum in their annuli to reduce convection losses. On the other hand, receivers with air-filled annuli, currently used mainly for process heat applications, are significantly less expensive, but their thermal performance is inferior to evacuated receivers. A promising technique that can bridge the cost and performance gap between the two types of receivers is introduced in this work. A heat-resistant thermal insulation material is fitted into the portion of the receiver annulus that does not receive concentrated sunlight. The presence of this insulation material is expected to reduce not only convection heat losses, but also radiation losses. This study focuses on the calculation of conduction and convection heat losses from the proposed receiver using numerical modeling. The performance of the proposed concept is compared to that of a conventional receiver with an air-filled annulus. The results have shown that the combined conduction and convection heat loss from the proposed receiver can be smaller than that from a receiver with an air-filled annulus by as much as 25% when fiberglass insulation is used. However, the fact that the thermal conductivity of the insulating material increases with temperature reduces the benefit of the proposed concept at high temperatures. As a result, the proposed receiver is expected to be suitable as a replacement for receivers with air-filled annuli or as an economical alternative to evacuated receivers that are used at the lower temperature end of utility-scale solar power plants.  相似文献   

7.
以熔盐为传热工质,对考虑自然对流条件下吸热管内熔盐的流动与传热进行了数值研究。结果表明:均匀热流下自然对流促进管内下侧和熔盐向管中心流动,弱化管内上侧熔盐向管中心流动;吸热管内下侧Nu数大于上侧Nu数,管内最大Nu数出现在底部,最小Nu数出现在顶部,吸热管内下侧Nu数与上侧Nu数的差值随着Re数增大而减小,但其平均Nu数变化较小,且其平均Nu数与不考虑自然对流影响的管内平均Nu数基本相等。非均匀热流下吸热管加热的上下位置对吸热管内单侧Nu数影响较大,但对平均Nu数无影响。同一Re数,吸热管上侧Nu数随着热流增高而最小。  相似文献   

8.
Effect of fins on heat transfer around a tube was investigated experimentally. A test tube of 30 mm diameter was installed in a test section of an open‐type wind tunnel as a single tube, or as a center tube in a single tube row and in a tube bundle of staggered layout. Fins made of paper were put on the test tube having certain fin spacing. It was clarified from the experiment that the local heat transfer coefficient around the tube degrades with decreasing fin spacing, especially on the downstream side of the tube, and the minimum fin spacing where the effect of the fin begins to appear is the largest for the single tube and the smallest for the tube bundle. © 2003 Wiley Periodicals, Inc. Heat Trans Asian Res, 32(5): 445–454, 2003; Published online in Wiley InterScience ( www.interscience.wiley.com ). DOI 10.1002/htj.10098  相似文献   

9.
The laminar flow of a plasma in the entrance region of a circular tube has been analyzed using an implicit finite-difference scheme. The solution is based upon the boundary-layer equations with the plasma radiation term retained in the energy equation, and the transverse convection term retained in both the momentum and energy equations. Numerical results have been obtained for an argon plasma having a linear enthalpy and cubic velocity profile at the tube entrance. At the low temperature limit of the analysis, the friction factor is in agreement with previously published results; and in all but a very small region near the tube entrance the local Nusselt number agrees with the Nusselt number for constant property, fully-developed flow to within approximately 17 per cent.  相似文献   

10.
In general heat transfer intensity between solid surface and coolant (fluid) depends on three main parameters: heat transfer coefficient, size of heat exchange surface and temperature difference between surface and fluid. Sometimes the last two parameters (surface size and temperature difference) are strictly limited due to the process or technological requirements, and only increase of heat transfer coefficient is allowed. Simplest way offering sufficient increase in heat transfer rate (heat transfer coefficient as well) is to go from the laminar fluid flow regime to the turbulent one by increasing flow velocity. In many cases it helps despite such disadvantages like more complicated fluid supply system, rise of fluid flow mass rate and growth of energy usage for pumping. But in some cases, for example, in space application, in nuclear engineering, etc. there is not allowed to use high flow velocity of coolant – gas (due to vibration danger) or to apply high mass rate of coolant – liquid (due to limitation concerning weight or mass). One of the possible solutions of that problem could be the usage of two-phase flow as a coolant. An idea to use such two-phase coolant for heat removal from the solid surface is not new. Boiling liquid (water especially), gas flow with liquid droplets and other two-phase systems are widely used for heat and mass transfer purposes in various industries like food, chemical, oil, etc. An application of such two-phase coolants has lot advantages; high value of heat transfer coefficient is one of the most important. Unfortunately nothing is ideal on the Earth. Restrictions on vibration, on coolant weight (or mass rate); necessity to generate two-phase flow separately from the heat removal place; requirements on very low coolant velocities and other constraints do not allow using such type of two-phase coolant for purposes which were mentioned above (space application especially). As a possible way out can be usage of the statically stable foam flow produced from gas (air) and surfactant solutions in liquid (water). Our previous investigations [J. Gylys, Hydrodynamics and Heat Transfer under the Cellular Foam Systems, Technologija, Kaunas, 1998] showed the solid advantages of that type of two-phase coolant, including high values of heat transfer coefficient (up to 1000 W/m2 K and more), low flow velocities (less than 1.0 m/s), small coolant density (less than 4 kg/m3), possibility to generate foam flow apart from the heat removal place, etc.This article is devoted to the experimental investigation of the staggered tube bundle heat transfer to the vertical upward and downward statically stable foam flow. The investigations were provided within the laminar regime of foam flow. The dependency of the tube bundle heat transfer on the foam flow velocity, flow direction and volumetric void fraction were analyzed. In addition to this, the influence of tube position in the bundle was investigated also. Investigation shows that the regularities of the tube bundle heat transfer to the vertical foam flow differ from the one-phase (gas or liquid) flow heat transfer peculiarities. It was showed that the heat transfer intensity of the staggered tube bundle to the foam flow is much higher (from 25 to 100 times) than that for the one-phase airflow under the same conditions (flow velocity). The results of the investigations were generalized using criterion equations, which can be applied for the calculation and design of the statically stable foam heat exchangers with the staggered tube bundles.  相似文献   

11.
Volumetric solar receivers are used in solar power plants to convert concentrated solar radiation into high temperature heat to operate a thermal engine. In general, porous high temperature materials are used for this purpose. Since the pore geometry is important for the efficiency performance of the receiver, current R&D activities focus on the optimization of this quantity. In this study, the influence of slight geometry changes of this component on its temperature distribution and efficiency has been investigated with the objective of an overall improvement. A numerical analysis of the mass and heat transfer through the receiver has been performed. The investigated receiver was an extruded honeycomb structure made out of Silicon Carbide. Additionally, experimental tests have been performed. In these tests, selected receiver samples have been exposed to concentrated radiation. From these tests solar-to-thermal efficiency data have been derived, which could be compared with the calculated data. Two numerical models have been developed. One makes use of the real geometry of the channel (single channel model), the other one considers the receiver to be “porous continuum”, which is described by homogenized properties such as permeability and effective heat conductivity. The experimental parameters such as the average solar heat flux and the mass flow were taken into account in the models as boundary conditions. Various quantities such as the average air outlet temperatures, the temperature distributions and the solar-to-thermal efficiency were used for the comparison. The correspondence between the experimental and numerical results of both numerical models confirms the capability of the approaches for further studies.  相似文献   

12.
Experiments on transition and flow boiling heat transfer with refrigerant R114 inside a horizontal tube were performed at bubble flow, critical heat flux and in the transition region between bubble flow and film boiling at mass fluxes between 1200 and 4000 kg/m2 s and in the pressure range between 5 and 15 bar. In comparison with pool boiling bubble flow heat transfer depends essentially on the mass flow rates and on the vapor quality. The critical heat flux depends less on the temperature difference than in pool boiling heat transfer and exhibits a maximal and a minimal value as a function of the pressure. The critical heat flux increases with mass flow rate as already shown by Collier. In the region of transition boiling the heat flux over the difference between wall and saturation temperature approaches a horizontal curve. Therefore in this region an evaporator may always be operated under stable conditions and burn out does not occur.  相似文献   

13.
横管降膜流动过程中,液膜速度和温度及其分布是影响传热传质的关键因素,由于实验研究方法的局限性,实验研究结果一般只是液膜内各参数的平均值,而液膜内部的速度和温度具体分布特性却很难得到。借助FLUENT软件,利用VOF模型研究了橫管外液膜速度和温度及其分布特性。通过建立三维数理模型,模拟研究了常温常压下,橫管外液膜无相变条件下横管液膜的传热过程,并从边界层的角度解释了液膜波动对传热过程的影响。  相似文献   

14.
The momentum and forced convection heat transfer for a laminar and steady free stream flow of nanofluids past an isolated square cylinder have been studied numerically. Different nanofluids consisting of Al2O3 and CuO with base fluids of water and a 60:40 (by mass) ethylene glycol and water mixture were selected to evaluate their superiority over conventional fluids. Recent correlations for the thermal conductivity and viscosity of nanofluids, which are functions of particle volumetric concentration as well as temperature, have been employed in this paper. The simulations have been conducted for Pe = 25, 50, 100 and 200, with nanoparticle diameters of 30 and 100 nm and particle volumetric concentrations ranging from 0% to 4%. The results of heat transfer characteristics of nanofluid flow over a square cylinder showed marked improvement comparing with the base fluids. This improvement is more evident in flows with higher Peclet numbers and higher particle volume concentration, while the particle diameter imposes an adverse effect on the heat transfer characteristics. In addition, it was shown that for any given particle diameter there is an optimum value of particle concentration that results in the highest heat transfer coefficient.  相似文献   

15.
The focus of the current study is the wind loads on a 11.92 m section of parabolic trough collector with an aperture of 5.76 m, located in Beijing, PR China. This paper presents selected results of full-scale field measurements of wind loads and wind pressure on the solar collector. The field data such as wind speed, wind direction and wind pressures are simultaneously measured from the solar collector. The measured data are analyzed to obtain the information on boundary layer wind characteristics, wind pressures and wind loads on the solar collector. The results presented in this paper are expected to be of considerable interest and of use to researchers and engineers involved in analysis and design of parabolic trough solar collectors.  相似文献   

16.
Solar Parabolic Trough Collectors (PTCs) are currently used for the production of electricity and applications with relatively higher temperatures. A heat transfer fluid circulates through a metal tube (receiver) with an external selective surface that absorbs solar radiation reflected from the mirror surfaces of the PTC. In order to reduce the heat losses, the receiver is covered by an envelope and the enclosure is usually kept under vacuum pressure. The heat transfer and optical analysis of the PTC is essential to optimize and understand its performance under different operating conditions. In this paper a detailed one dimensional numerical heat transfer analysis of a PTC is performed. The receiver and envelope were divided into several segments and mass and energy balance were applied in each segment. Improvements either in the heat transfer correlations or radiative heat transfer analysis are presented as well. The partial differential equations were discretized and the nonlinear algebraic equations were solved simultaneously. Finally, to validate the numerical results, the model was compared with experimental data obtained from Sandia National Laboratory (SNL) and other one dimensional heat transfer models. Our results showed a better agreement with experimental data compared to other models.  相似文献   

17.
INTR0DUCTI0NNaturalconvectioninenclosureshasbeenfoundinavariety0fapplications,suchassolarcollectors,nu-cleartechn0logies,thecoolingofelectronicalcircuits,etc.Amongthemnaturalconvectioninsideanen-closedrectangularcavityisthemostclassicalproblem.Correspondinglyagreatdealofexperimentalandnumericalworkhasbeendoneinsuchafieldwiththe"clean"boundaryCPnditi0nsofuniformwalltem-perature(UWT)anduniformheatflch(UHF).Re-celltlymoreattelltionispaidontheconvectioninthecirculartube.HwangandLai[11inves…  相似文献   

18.
Experimental study was performed on the convective heat transfer of gaseous solid suspension flow within helically coiled circular tube. The results show that the increase in heat transfer is greater than that due to the simple contribution of the increased heat capacity as the flowing media. This suggests that the addition of the suspended phase into the flows with curved stream lines can bring about the substantial reduction in the convective heat transfer resistance in the vicinity of the channel walls of the outer curvature portion. However, slight decrease in mixture Stanton number is also observed at the slight loading ratio region and the sublayer disturbing effect is seen to be gradually saturated at the higher loading region. Accordingly, overall reduction in the turbulence level also exists in the turbulent core of the flow and it is expected that there is an optimum solid loading ratio at which the viscous sublayer disturbing effect on the overall heat transfer performance is most effective.  相似文献   

19.
In this study, the optical and thermal performance of a Parabolic Trough Collector PTC system is investigated theoretically. A series of numerical simulations and theoretical analysis has been conducted to investigate the effect of the receiver geometry and location relative to the focal line on its optical performance. The examined receiver geometries are circular, square, triangular, elliptical and a new design of circular- square named as channel receiver. The thermal performance of PTC is studied for different flow rates from (0.27 to 0.6 lpm) theoretically. Results showed that the best optical design is the channel receiver with an optical efficiency of 84% while the worst is the elliptical receiver with an optical efficiency of 70%. Thermally the best design is the elliptical receiver with a thermal efficiency of 85% while the worst is the circular receiver with a thermal efficiency of 82%.  相似文献   

20.
A theoretical study of the thermal development of forced convection was performed using a circular tube filled with a saturated porous medium, with constant wall heat flux, and with the effect of viscous dissipation. The solution was obtained using the method of separation of variables. The Sturm–Liouville system was solved for the eigenvalues. Ordinary differential equations for the eigenfunctions were solved numerically by the fourth-order Runge–Kutta method. Results show that, in the presence of the viscous dissipation, both the level and distribution of temperature are altered remarkably, even for small values of the Brinkman number, Br, which is the ratio of heat generation caused by viscous dissipation to the value of heat flux at the wall. The value of the local Nusselt number, Nu, is demonstrably independent of Br, unlike the situation in which the wall temperature remains constant.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司    京ICP备09084417号-23

京公网安备 11010802026262号