首页 | 官方网站   微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 250 毫秒
1.
To improve the limiting current interruption capability and minimizing vacuum interrupter with axial magnetic field (AMF) electrodes, it is significant to investigate the vacuum arc behaviours between the contacts. AMF distributions of the slot type electrodes were studied by both numerical analysis and experiments. Furthermore, the behaviours of vacuum arcs for different parameters of the slot type AMF electrodes were investigated by using high-speed CCD camera. The influences of gap distance, contact diameter and phase shift time between AMF and arc current on the vacuum arc were investigated. The results provide a reference for research and development of vacuum interrupters with slot type or other types of AMF electrode.  相似文献   

2.
The influence of an arc current on the discharge development and the arc modes of a single coil type axial magnetic field (AMF) electrode were investigated by a high-speed charge couple device (CCD) video camera in a long gap distance of 40 mm. The distribution of the axial magnetic field of the single coil type AMF electrode was computed. By computational results, the single coil type AMF electrode could generate higher axial magnetic flux density than the slot type AMF electrode. It was found that the single coil type AMF electrode could perform better than the slot type AMF electrode with the same designing parameters. And the development of the arc modes experienced diffuse mode, constricted but unstable mode, and constricted and stable mode with the amplitude of the arc current increasing. The correlation between the vacuum arc and the noise components of arc voltage was investigated too. The interruption capability could be known in a practical commercial vacuum interrupter by the test results in a demountable vacuum interrupter (DVC) with a electrode diameter of 50 mm and a gap distance of 40 mm.The test results could provide reference to design the high voltage vacuum interrupter adopting the single coil type AMF electrode.  相似文献   

3.
Based on a two-dimensional axisymmetric magneto-hydrodynamic (MHD) model, low current vacuum arc (LCVA) characteristics are studied. The influence of cathode process under different axial magnetic fields and different anode radii on LCVA characteristics is also simulated. The results show that the influence of both cathode process and anode radii on LCVA is significant. The sign of anode sheath potentials can change from negative to positive with the decrease of anode radii. The simulation results are in part verified by experimental results. Especially, as the effect of ion kinetic energy is considered, ion temperature is improved significantly; which is in agreement with experimental results.  相似文献   

4.
In this study, the influence of the initial jet angles (IJAs) and ion number densities (INDs) at the cathode side on the low current vacuum arc (LCVA) characteristics is simulated and analysed. The results show that the ion temperature, electron temperature, ion number density, axial current density and plasma pressure all decrease with the increase of the cathode IJAs. It is also shown that LCVA can cause a current constriction for lower cathode IND, and the anode sheath potential is more nonuniform, which is mainly related to the nonuniform distribution of the axial current density at the anode side.  相似文献   

5.
High Power Microwave Test System and Simulated Experiments for HT-7   总被引:2,自引:0,他引:2  
In lower hybrid current drive (LHCD) experiments in HT-7, LH wave coupled to the plasma from 12 klystrons is launched by a phased multi-junction grill. High power microwave reflection or arc, which threatens the klystrons, the wave-guide ceramic windows and the vacuum of the tokamak, occur sometimes during the experiments. For the sake of safety, a high power microwave test system to perform simulations was developed. In the test experiments, the klystron and window can be well protected with an optimized microwave monitor and a PIN switch. The layout of the test system and the simulated experiments for HT-7 are described in this paper.  相似文献   

6.
The dynamic process of arc pressure and corresponding arc column expansion, which is the main feature after arc ignition and has a significant effect on the breaking behaviour of low -voltage circuit breakers, is studied. By constructing a three dimensional mathematical model of air arc plasma and adopting the Control Volume Method, the parameters of arc plasma including temperature and pressure are obtained. The variations of pressure field and temperature field with time are simulated. The result indicates that there are six stages for the process of arc column expansion according to the variation of pressure in arc chamber. In the first stage, the maximal pressure locates in the region close to cathode, and in the second stage the maximal pressure shifts to the region close to the anode. In the third stage, the pressure difference between the middle of arc column and the ambient gas is very large, so the arc column begins to expand apparently. In the fourth stage, the pressure wave propagates towards both ends and the maximal pressure appears at the two ends when the pressure wave reaches both sidewalls. In the fifth stage, the pressure wave is reflected and collides in the middle of the arc chamber. In the last stage, the propagation and reflection of pressure wave will repeat several times until a steady burning state is reached. In addition, the experimental results of arc column expansion, corresponding to the arc pressure variation, are presented to verify the simulation results.  相似文献   

7.
The influence of copper vapor on the low-voltage circuit breaker arcs is studied. A three-dimensional (3-D) magnetohydrodynamics(MHD) model of arc motion under the effect of external magnetic field is built up. By adopting the commercial computational fluid dynamics (CFD) package FLUENT based on control-volume method, the above MHD model is solved. For the mediums of air-1% Cu and air-10% Cu, the distributions of stationary temperature, pressure, electrical potential and the arc motion processes are compared with those of a pure air arc. The copper vapor diffusion process in the arc chamber and the distribution of copper vapor mass concentration are also simulated. The results shows that the copper vapor has a cooling effect on the arc plasma and can decrease the stationary voltage as well. Moreover, the presence of copper vapor can decelerate the arc motion in the quenching chambers. The maximal copper vapor concentration locates behind the arc root because of the existence of a "double vortex" near the electrodes.  相似文献   

8.
The study of arc behavior is important to understand the dynamic phenomena concerning the interruption process in a variety of switching devices. This paper is devoted to investigate the influence of gassing material on blow open force and arc motion. To one double- breaker model, measuring the arc current, voltage and force acting on the moving conductor, the characteristics of the ratio of the emerging blow open force over arc power FB/(ui) could be obtained. With the help of a 2-D optical fiber measurement system, to one arc chamber model, arc motion behavior was measured, too. It is demonstrated that, with the action of gassing material, FB/(ui) will increase 2.5 times, and the arc will enter the splitter plates much easier.  相似文献   

9.
The preparation of crystalline C3N4 films was investigated using pulsed arc discharge from mixed methanol and ammonia water at atmospheric pressure. The X-ray diffraction (XRD) patterns of the films prepared at a substrate temperature of 450℃ suggested that the film was composed of α-C3N4 and fl-C3N4 crystallites. Raman spectra exhibited distinct peaks which are in good agreement with those predicted theoretically for C3N4 crystallites.  相似文献   

10.
Temperature and Nitric Oxide Generation in a Pulsed Arc Discharge Plasma   总被引:1,自引:0,他引:1  
Nitric oxide (NO) is increasingly being used in medical treatments of high blood pressure, acute respiratory distress syndrome and other illnesses related to the lungs. Currently a NO inhalation system consists of a gas cylinder of N2 mixed with a high concentration of NO. This arrangement is potentially risky due to the possibility of an accidental leak of NO from the cylinder. The presence of NO in the air leads to the formation of nitric dioxide (NO2), which is toxic to the lungs. Therefore, an on-site generator of NO would be highly desirable for medical doctors to use with patients with lung disease.
To develop the NO inhalation system without a gas cylinder, which would include a high concentration of NO, NAMIHIRA et al have recently reported on the production of NO from room air using a pulsed arc discharge. In the present work, the temperature of the pulsed arc discharge plasma used to generate NO was measured to optimize the discharge condition. The results of the temperature measurements showed the temperature of the pulsed arc discharge plasma reached about 10,000 K immediately after discharge initiation and gradually decreased over tens of microseconds. In addition, it was found that NO was formed in a discharge plasma having temperatures higher than 9,000 K and a smaller input energy into the discharge plasma generates NO more efficiently than a larger one.  相似文献   

11.
A new magnetic hydro-dynamics model for nozzle arc emphasizing the interaction of arc with PTFE (polytetrafluorethylene) vapour is established based on the conservation equations. The interruption of auto-expansion circuit breaker is simulated numerically by finite element method and the influence of PTFE vapour on the arc is analysed with this model. The results reveal that the flow field inside the arc chamber is determined by the arc current, the arcing time, the nozzle arc and the clogging of its thermal boundary. The establishment of quenching pressure relies on both SF6 gas and PTFE vapour that absorbed arc energy in the nozzle. The PTFE vapour leads to an increase in the pressure of nozzle arc obviously, and a decrease in the temperature of arc. But it enhances the temperature of arc at zero current and slows down the decreasing rate of arc temperature as the current decreases.  相似文献   

12.
Excellent vacuum performance ensures a high beam transmission efficiency of the neutral beam injector (NBI). The vacuum performance is mainly determined by the cryoperformance of the cryopanel of the cryocondensation pumps which are the main vacuum pumps of NBI. In order to optimize the cryoperformance, the requirements for the temperature distribution and the heat load of the cryopanel are analysed and the factors that affect the cryopanel's temperature distribution are studied. The results indicate that the temperature difference of the cryopanel can be reduced by fabricating the cryopanel with high thermal conductivity material, increasing its thickness and cutting the distance between the two upward cooling pipes. The results may be applied to a cryopanel cooled by forced flow liquid helium.  相似文献   

13.
本文将氢化钛镍合金材料应用于强流长脉冲(200 A/270 μs)真空弧放电实验中,该材料能在强流长脉冲真空弧放电产生的高温条件下保持较好的稳定性。使用飞行时间谱仪获得了氢化钛镍合金阴极真空弧放电产生的离子电荷态分布和离子成分。结果表明:Tin+和Nin+电荷态为1+、2+和3+,在放电过程的早期(0~30 μs),H+成分随时间逐渐增加,在30 μs时达到最大比例57%,而Tin+和Nin+(n=1,2,3)离子成分随时间逐渐减少,在30 μs时达到最小比例43%;在放电过程的后期(30~270 μs),H+成分迅速下降且在75 μs后保持在总离子流的12%左右直至放电结束,Tin+和Nin+(n=1,2,3)含量随时间逐步增加,且在75 μs后保持在总离子流的88%左右直至放电结束。  相似文献   

14.
Non-thermal plasma at atmosphere was generated through glidarc discharge driven by magnetic field and observed by using a high speed charge coupled device (CCD) and photo multiplier tube (PMT). The arc diameter projecting in the direction of arc motion (front-viewed diameter) and the diameter projecting in the perpendicular direction of arc motion (side-viewed diameter) were measured. The effect of both the arc current and the magnetic field was analysed. The front-viewed diameter was compared with the side-viewed one. Simultaneously the electricfield intensity was measured directly and analysed by considering the effect of the external magnetic field and arc current.  相似文献   

15.
In this paper, characteristics of a treatment and operated at atmospheric pressure dual torch plasma arc used for hazardous waste are studied, and also compared with those of the multi-torch plasma arc and the single torch plasma arc. The dual torch plasma arc is generated between the cathode and anode with argon as the working gas. The temperature distributions of the plasma arc are measured using a spectroscope and line pair method with the assumption of local thermodynamic equilibrium (LTE) for the DC arc current I=100 A and argon flow rate Q = 15 slpm. The measurements show that the temperatures of the dual torch arc plasma in the regions near the cathode, the anode and the center point are 10,000 K, 11,000 K and 9,000 K, respectively. And the high temperature region of the multi torch plasma arc is of double or much wider size than that of a conventional dual torch plasma arc and single plasma torch. Based on the preceding studies, a dual torch plasma arc furnace is developed in this study. The measured gas temperature at the center region of the argon arc is about 11,000 K for the case of I=200 A and Q=30 slpm operated in atmosphere.  相似文献   

16.
Three tungsten coatings with a thickness of 250 μm, 600μm and 220 μm, respectively, were deposited on a CuCrZr substrate by the vacuum plasma spraying technology. In order to study the thermal performance of the coatings, heat load limit, thermal fatigue lifetime and thermal response tests were performed by means of the electron beam irradiation with a heat flux from 0 MW/m^2 to 10 MW/m^2. Experimental results indicated that tungsten coatings on CuCrZr with a titanium or tungsten/copper interlayer could expel heat flux timely and had good thermal fatigue properties, titanium was a promising compliant layer which provided a reliable way to join tungsten onto the CuCrZr heat sink, even suffering from a heat flux of 10 MW/m^2 or withstanding 54 cycles of fatigue tests under 5 MW/m^2. However, the better quality of tungsten coating itself was necessary because its surface temperature was higher than that of the sample with a tungsten/copper interlayer.  相似文献   

17.
A multi-functional micro-arc plasma spraying system was developed according to aerodynamics and plasma spray theory. The soft switch IGBT (Insulated Gate Bipolar Transistor) invert technique, micro-computer control technique, convergent-divergent nozzle structure and axial powder feeding techniques have been adopted in the design of the micro-arc plasma spraying system. It is not only characterized by a small volume, a light weight, highly accurate control, high deposition efficiency and high reliability, but also has multi-functions in plasma spraying, welding and quenching. The experimental results showed that the system can produce a supersonic flame at a low power, spray Al2O3 particles at an average speed up to 430 m/s, and make nanostructured AT13 coatings with an average bonding strength of 42.7 MPa. Compared to conventional 9M plasma spraying with a higher power, the coatings with almost the same properties as those by conventional plasma spray can be deposited by multi-functional micro-arc plasma spraying with a lower power plasma arc due to an improved power supply design, spray gun structure and powder feeding method. Moreover, this system is suitable for working with thin parts and undertaking on site repairs, and as a result, the application of plasma spraying will be greatly extended.  相似文献   

18.
Numerical simulations of 10 kW and 110 kW inductively coupled plasma (ICP) wind tunnels were carried out to study physical properties of the flow inside the ICP torch and vacuum chamber with air as tile working gas. Two-dimensional compressible axisymmetric Navier- Stokes (N-S) equations that took into account 11 species and 49 chemical reactions of air, were solved. A heat source model was used to describe the heating phenomenon instead of solving the electromagnetic equations. In the vacuum chamber, a four-temperature model was coupled with N-S equations. Numerical results for tile 10 kW ICP wind tunnel are presented and discussed in detail as a representative case. It was found that the plasma flow in the vacuum chamber tended to be in local thermoehemical equilibrium. To study the influence of operation conditions on the flow field, simulations were carried out for different chamber pressures and/or input powers. The computational results for the above two ICP wind tunnels were compared with corresponding experimental data. The computational and experimental results agree well, therefore the flow fields of ICP wind tunnels can be clearly understood.  相似文献   

19.
Doped graphite GBST1308, mechanically jointed to CuCrZr alloys, will be applied on EAST superconducting as plasma facing material (PFM). Two joint structures called joint-1 and joint-2 were evaluated by means of thermal response tests using electron beam facility. The experimental results showed that the temperature differences of two joints were not significant, and the maximum surface temperature was about 1055℃ at a load of 4 MW/m^2, which had a good agreement with the simulated results by ANSYS code. The results indicated that the doped graphite GBST1308/CuCrZr mock-up can withstand heat flux deposition of 4 MW/m^2 except at the screw-fastened region, and joint-2 could be more suitable to higher heat flux region such as divertor target. But under the higher heat flux, both joints are unacceptable, an advanced PFM and its integration with the heat sink have to be developed, for example, vacuum plasma spraying tungsten coatings on the CuCrZr might be a good choice.  相似文献   

20.
The neutron shielding component of ITER (International Thermonuclear Experimental Reactor) vacuum vessel is a kind of structure resembling a wall in appearance. A FE (finite element) model is set up by using ANSYS code in terms of its structural features. Static analysis, thermal expansion analysis and dynamic analysis are performed. The static results show that the stress and displacement distribution are allowable, but the high stress appears in the junction between the upper and lower parts. The modal analysis indicates that the biggest deformation exists in the port area. Through modal superposition, the single-point response has been found with the lower rank frequency of the acceleration seismic response spectrum. But the deformation and the stress values are within the permissible limit. The analysis results would benefit the work in the next step and provide some reference for the implementation of the engineering plan in the future.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司    京ICP备09084417号-23

京公网安备 11010802026262号