首页 | 官方网站   微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
OBJECTIVE: To evaluate the use of a portocaval venograft without an ameroid constrictor in the surgical management of intrahepatic portosystemic shunts (PSS). STUDY DESIGN: Prospective clinical study. ANIMALS: Seven dogs with intrahepatic PSS. METHODS: Portal pressure was measured after temporary suture occlusion of the intrahepatic PSS. In dogs with an increase in portal pressure > or =8 mm Hg or signs of portal hypertension, a single extrahepatic portocaval shunt was created using a jugular vein. Clinical outcome and complications were recorded. RESULTS: The mean (+/-SD) portal pressure increased from 5.9+/-1.6 to 17.9+/-4.1 mm Hg with PSS occlusion. There were no intraoperative complications and, after creation of the portocaval shunt, the intrahepatic PSS could be completely ligated in all dogs. The final portal pressure was 9.6+/-1.9 mm Hg. Complications developed during postoperative hospitalization in 5 dogs and included incisional discharge (4 dogs), ascites (3), ventricular premature contractions (2), and melena, bloody diarrhea, neurologic signs, coagulopathy, and aspiration pneumonia (each in 1 dog). Six dogs died or were euthanatized with clinical signs related to depression, inappetance, abdominal pain, vomiting, melena, and abdominal distention, with a median survival of 82 days (range, 20-990 days). One dog was clinically normal at 33 months after surgery. CONCLUSIONS: Clinical signs observed in 6 dogs after surgery were consistent with portal hypertension. Use of a portocaval venograft without an ameroid constrictor may reduce the likelihood of hepatic vascular development, thereby increasing the risk of life-threatening portal hypertension should the venograft suddenly occlude. CLINICAL RELEVANCE: Use of a portocaval venograft without an ameroid constrictor to control portal hypertension after ligation of an intrahepatic PSS cannot be recommended.  相似文献   

2.
OBJECTIVES: To evaluate use of an ameroid ring constrictor (ARC) for treatment for single extrahepatic portosystemic shunts (PSSs) and identify factors associated with postoperative death, continued portosystemic shunting, and long-term outcome in dogs. DESIGN: Retrospective study. ANIMALS: 168 dogs with a single extrahepatic PSS. PROCEDURE: Medical records of dogs that had a single extrahepatic PSS and were treated with an ARC were reviewed. Signalment, history, clinical signs, results of preoperative blood analyses and portal pressure measurements, PSS location, ARC size, postoperative complications, and postoperative scintigraphy results were recorded. Owners were interviewed 6 months to 6 years after surgery. Results-Postoperative complications developed in 10% of dogs. Postoperative mortality rate was 7.1%. Predictive factors for postoperative death included high preoperative WBC count and postoperative complications. Twenty-one percent of dogs in which portal scintigraphy was performed 6 to 10 weeks after surgery had continued shunting. Predictive factors for persistent shunting included low preoperative plasma albumin concentration, high portal pressure after complete occlusion, and high portal pressure difference (postocclusion minus baseline). Clinical outcome in 108 dogs was classified as excellent (80%), good (14%), or poor (6%). Predictive factors for excellent long-term clinical outcome included high preoperative plasma albumin concentration, low preoperative leukocytosis, low portal pressure after complete occlusion, absence of postoperative seizures, and absence of continued shunting. CONCLUSIONS AND CLINICAL RELEVANCE: Use of an ARC for treatment for a single extrahepatic PSS resulted in low morbidity and mortality rates. Certain preoperative factors were associated with increased risk of postoperative death, continued portosystemic shunting, and long-term outcome.  相似文献   

3.
OBJECTIVE: To document the signalment; history; clinical signs; clinicopathologic, diagnostic imaging, and surgical findings; perioperative complications; and long-term clinical results of ameroid ring constrictor (ARC) placement on single extrahepatic portosystemic shunts (PSS) in cats. DESIGN: Retrospective study. ANIMALS: 23 cats treated with an ARC on a single extrahepatic PSS. PROCEDURE: An ARC was placed surgically around the PSS. Portal pressure was measured prior to ARC placement, with complete temporary PSS occlusion, and after ARC placement. Cats were scheduled for recheck transcolonic portal scintigraphy 8 to 10 weeks after surgery. Follow-up information was obtained by telephone interview with the owners. RESULTS: An ARC was successfully placed in 22 of 23 cats. Intraoperative complications, consisting of PSS hemorrhage, occurred in 2 cats. Mean (+/- SD) portal pressure (n = 15) was 6.7+/-2.9 mm Hg before PSS manipulation, 18.6+/-7.7 mm Hg with complete temporary PSS occlusion, and 6.9+/-2.7 mm Hg after ARC placement. Postoperative complications developed in 77% (17 of 22) of cats after ARC placement, and included central blindness, hyperthermia, frantic behavior, and generalized motor seizures. Perioperative mortality rate was 4.3% (1 of 23). Persistent shunting was identified in 8 of 14 cats. Overall, 75% (15 of 20) of cats had an excellent long-term outcome. CONCLUSIONS AND CLINICAL RELEVANCE: Placement of an ARC on single extrahepatic PSS in cats resulted in low surgical complication and perioperative mortality rates, but most cats did have substantial postoperative complications. Persistent shunting was common, although many cats with persistent shunting were clinically normal.  相似文献   

4.
Liver lobectomy for complete attenuation of intrahepatic portosystemic shunts appears to be a safe and effective surgical treatment. When the intrahepatic shunt vessel can be definitively palpated within a liver lobe or its presence confirmed portographically, liver lobectomy represents a technically simple and effective method of complete shunt attenuation. To maintain portal pressure at an acceptable value after lobectomy, an extrahepatic portocaval shunt vessel can be created by use of an external jugular vein graft. A second shunt vessel can be created if portal pressure remains increased after placement of 1 shunt. Gradual and safe attenuation of the shunt vessel is achieved by placement of an ameroid constrictor on the extrahepatic graft at the time of the initial surgery.  相似文献   

5.
OBJECTIVES: To evaluate outcome in dogs with left divisional intrahepatic portosystemic shunts (PSS) treated by partial ligation (PL) or ameroid ring constrictor (ARC) placement on the left hepatic vein. DESIGN: Retrospective study. ANIMALS: Dogs (n=28) with left divisional intrahepatic PSS. METHODS: Retrieved data from medical records of dogs with left divisional intrahepatic PSS that had PL (n=17) or ARC (n=11) were signalment, history, clinical signs, preoperative blood work, portal pressure measurements, ARC size, complications and postoperative technetium scintigraphy. Outcome assessed by owner interview 6 months-10 years after surgery was classified as excellent, good or poor. Differences were tested by exact chi2 test. RESULTS: Major complications occurred in 3 dogs: coagulopathy (1 PL dog died), ascites (1 PL dog survived) and seizures (1 ARC dog died). Eight PL dogs had technetium portal scintigraphy; 1 dog was negative and 7 dogs positive for persistent shunting. Seven ARC dogs had scintigraphy; 4 dogs were negative and 3 positive for persistent shunting. In PL dogs, long-term clinical outcome was excellent (92%) or good (8%) whereas, in ARC dogs it was excellent (20%), good (50%) or poor (30%). This outcome difference between treatment groups was significant (P=.0012). CONCLUSION: Dogs treated by PL had significantly better long-term outcome compared with ARC treated dogs. CLINICAL RELEVANCE: Based on these data, ARC placement on the left hepatic vein in dogs with left-divisional intrahepatic PSS cannot be recommended.  相似文献   

6.
OBJECTIVE: To compare the perioperative outcomes of single extrahepatic portosystemic shunt occlusion by complete and partial silk ligation and ameroid constrictor placement in dogs. DESIGN: A retrospective analysis of 30 dogs with single congenital extrahepatic shunts. PROCEDURE: Records between 1990 and 2000 were reviewed. Patient age, breed, weight, presenting clinical signs, clinical pathology results, diagnostic imaging results, the surgery procedure performed, implant used, time taken, intra operative complications and perioperative complications were recorded. Mortality rates were calculated. RESULTS: Twenty dogs had a silk ligation procedure, 10 partially occluded and 10 completely. Ten dogs had an ameroid constrictor placement procedure. Ameroid constrictor surgery was significantly shorter in duration than silk ligation. Time for silk ligation was 91.8 +/- 35.2 minutes (median 90.0); time for ameroid constrictor placement was 71.5 +/- 12.0 (median 72.5, P = 0.049). A reduction in intraoperative complications was also noted in the ameroid constrictor surgery group. CONCLUSION: The ameroid constrictor offered a surgical occlusion procedure of single extrahepatic portosystemic shunts in dogs that was clinically as effective as silk ligation in the perioperative period, with a significantly shorter surgery time.  相似文献   

7.
We describe the use of ultrasonography‐guided percutaneous splenic injection of agitated saline and heparinized blood for the diagnosis of portosystemic shunts (PSS) in 34 dogs. Agitated saline mixed with 1 ml of heparinized autologous blood was injected into the spleen of 34 sedated dogs under sonographic guidance. The transducer was then sequentially repositioned to visualize the portal vein, the caudal vena cava, and the right atrium through different acoustic windows. It was possible to differentiate between intrahepatic and extrahepatic shunts depending on the entry point of the microbubbles into the caudal vena cava. Portoazygos shunts and portocaval shunts could be differentiated based on the presence of microbubbles in the caudal vena cava and/or the right atrium. In one dog, collateral circulation due to portal hypertension was identified. In dogs with a single extrahepatic shunt, the microbubbles helped identify the shunting vessel. The technique was also used postoperatively to assess the efficacy of shunt closure. All abnormal vessels were confirmed by exploratory laparotomy or with ultrasonographic identification of the shunting vessel. Ultrasound‐guided transsplenic injection of agitated saline with heparinized blood should be considered as a valuable technique for the diagnosis of PSS; it is easy to perform, safe, and the results are easily reproducible.  相似文献   

8.
The aims of this study were to determine if accurate diagnosis of congenital portosystemic shunt was possible using two dimensional, grey-scale ultrasonography, duplex-Doppler, and color-flow Doppler ultrasonography in combination, and to determine if dogs with congenital portosystemic shunts have increased or variable mean portal blood flow velocity. Eighty-two dogs with clinical and/or clinicopathologic signs compatible with portosystemic shunting were examined prospectively. Diagnosis of congenital portosystemic shunt was subsequently confirmed in 38 of these dogs using operative mesenteric portography: 14(37%) dogs had an intrahepatic shunt and 24(63%) had an extrahepatic shunt. Ultrasonography had a sensitivity of 95%, specificity of 98%, and accuracy of 94%. Ultrasonographic signs in dogs with congenital portosystemic shunts included small liver, reduced visibility of intrahepatic portal vessels, and anomalous blood vessel draining into the caudal vena cava. Correct determination of intra - versus extrahepatic shunt was made ultrasonographically in 35/38 (92%) dogs. Increased and/or variable portal blood flow velocity was present in 21/30 (70%) dogs with congenital portosystemic shunts. In one dog with an intrahepatic shunt the ultrasonographic diagnosis was based partly on finding increased mean portal blood flow velocity because the shunting vessel was not visible. Detection of the shunting vessel and placement of duplex-Doppler sample volumes were facilitated by use of color-flow Doppler. Two-dimensional, grey-scale ultrasonography alone is sufficient to detect most intrahepatic and extrahepatic shunts; sensitivity is increased by additional use of duplex-Doppler and color-flow Doppler. Increased and/or variable portal blood flow velocity occurs in the majority of dogs with congenital portosystemic shunts.  相似文献   

9.
OBJECTIVE : To report outcomes after cellophane banding of single congenital portosystemic shunts in dogs and cats. STUDY DESIGN : Retrospective study of sequential cases. ANIMALS : One hundred and six dogs and five cats. METHODS : Medical records were reviewed for breed, sex, age at surgery, shunt anatomy, results of pre- and postoperative biochemical analysis, development of postligation neurologic dysfunction, portal hypertension or other serious complications, and the owners' perception of their animal's response to surgery. RESULTS : Ninety-five dogs and all 5 cats had extrahepatic shunts. Eleven dogs had intrahepatic shunts. Six dogs (5.5%) died as a result of surgery from portal hypertension (2 dogs), postligation neurologic dysfunction (2), splenic hemorrhage (1) and suspected narcotic overdose (1). Serious complications were more common in dogs with intrahepatic shunts than those with extrahepatic shunts (P=.002). Postligation neurologic dysfunction necessitated treatment in 10 dogs and 1 cat; 8 dogs and the cat survived. Clinical signs attributed to portosystemic shunting resolved or were substantially attenuated in all survivors. Postoperative serum bile acid concentrations or results of ammonia tolerance testing were available for 88 animals; 74 (84%) were normal and 14 (16%) were abnormal. Multiple acquired shunts were documented in two animals. CONCLUSIONS : Cellophane banding is a safe and effective alternative to other methods of attenuation. CLINICAL RELEVANCE : Slow occlusion of portosystemic shunts using a variety of methods is being evaluated world wide. Cellophane banding is a relatively simple procedure with comparable safety and efficacy to previously reported techniques.  相似文献   

10.
A method for intraoperative measurement of portal blood flow velocity with duplex Doppler ultrasonography in 7 dogs with congenital intrahepatic portosystemic shunts is described. The aims of the study were to determine whether intraoperative ultrasonography was an acceptable alternative to mesenteric portography in such dogs and to identify quantitative portal hemodynamic variables that might correlate with clinical outcome better than portal pressure does. Ultrasonographic measurements did not influence decision-making by the surgeon, who attenuated the shunt on the basis of appearance of the viscera and change in mean systemic arterial blood pressure. All dogs recovered without complications, and surgery was considered to be successful in all 7. Intraoperative B-mode ultrasonography provided real-time information about the anatomy of the shunt and the portal branches, suggesting that it may be a useful alternative to mesenteric portography. The time-averaged mean portal blood velocity ranged from 6.5 to 33.7 cm/s before shunt attenuation and from 5.0 to 9.5 cm/s after shunt attenuation. This narrow range of postligation velocities suggested that intraoperative ultrasonography might be an alternative to intraoperative portal pressure measurement.  相似文献   

11.
OBJECTIVE : To determine prognostic evaluation and correlation of the degree of narrowing and the diameter of the portal vein in dogs with a congenital portosystemic shunt (CPS). STUDY DESIGN : Longitudinal prospective study. ANIMALS : Ninety-seven dogs with CPS. METHODS : Shunt diameter was recorded before and after silk ligation to calculate degree of closure. Portal vein diameter was measured in 74 dogs. Short-term (30 days) and long-term (>1 year) outcome were evaluated. Dogs with clinical signs after 1 year were re-examined to assess the degree of portosystemic shunting and compared with matched operated dogs without clinical signs. Correlations between clinical outcome, degree of closure, and portal vein diameter were statistically analyzed. RESULTS : Short-term and long-term mortality were 27% and 2.9% respectively. Clinical recurrence occurred in 10% of dogs. The degree of closure was significantly associated with mortality, but not with clinical recurrence. A significant correlation was found between degree of closure and the diameter of the cranial part of the portal vein. Portal vein diameter was only significantly associated with mortality in extrahepatic CPS. Subclinical portosystemic shunting was confirmed in 3 of 10 dogs. CONCLUSION : The degree of shunt closure depended on portal development. Long-term outcome did not depend on the degree of closure or portal development at the time of surgery. This suggested that factors such as hepatic and portal regeneration after surgery may be important. CLINICAL RELEVANCE : Determination of factors that predict the outcome after surgical treatment of CPS in dogs is important to gain insight in treatment selection or new therapeutic options.  相似文献   

12.
Objective To evaluate the efficacy and short term effects of a cellophane banding technique for progressive attenuation of canine single extrahepatic portosystemic shunts.
Design A prospective trial of 11 dogs with single congenital extrahepatic shunts.
Procedure Rectal ammonia tolerance testing and routine biochemical tests were performed preoperatively on all dogs. In seven dogs, preoperative abdominal Doppler ultrasonography was also performed. Exploratory laparotomy revealed a single extrahepatic portocaval shunt in each animal, which was attenuated using a cellophane band with an internal diameter of 2 to 3 mm. The abdomen was closed routinely. Follow-up biochemical analysis and abdominal Doppler ultrasonography or splenoportography were performed postoperatively.
Results The shunt was not amenable to total ligation in 11 dogs, based upon reported criteria. All dogs recovered uneventfully from surgery without evidence of portal hypertension, and showed clinical improvement thereafter. Shunt occlusion was deemed to have occurred in 10 dogs based on resolution of biochemical and/or sonographic abnormalities. One dog continued to have sonographic evidence of portosystemic shunting when evaluated 3 weeks after surgery, despite normal ammonia tolerance, but was lost to subsequent follow-up. Two dogs, in which 3 mm cellophane bands were placed, experienced delayed shunt occlusion.
Conclusion Cellophane banding is simple to perform, and causes progressive attenuation of single extrahepatic shunts in dogs. Further work is needed to determine the maximum diameter of a cellophane band which will produce total attenuation, and the long-term safety and reliability of the treatment.  相似文献   

13.
OBJECTIVE: To evaluate the efficacy of cellophane banding of single congenital extrahepatic portosystemic shunts in dogs using transcolonic portal scintigraphy. To investigate the portal circulation of those dogs with elevated postoperative shunt fractions to determine the cause of the persistent shunting. Further, to evaluate whether presenting signs, clinical pathology findings and liver histopathology are predictive of outcome. DESIGN: Prospective study of 16 dogs presenting with single congenital extrahepatic portosystemic shunts. PROCEDURE: Dogs with single extrahepatic portosystemic shunts attenuated by cellophane banding underwent portal scintigraphy and bile acids tolerance testing pre- and post-operatively. Dogs identified with elevated shunt fractions at 10 weeks post-operatively underwent mesenteric portovenography. Qualitative hepatic histopathology from all dogs was reviewed by a veterinary pathologist and assigned a semi-quantitative score to identify any abnormalities that may predict surgical outcome. RESULTS: At 10 weeks post cellophane banding, 10 of 16 cases (63%) had normal shunt fractions, whilst six dogs (37%) had increased shunt fractions and seven dogs (44%) had increased serum bile acids. Of these dogs, mesenteric portovenography revealed incomplete closure of the shunt in three dogs (18.6%) and multiple acquired shunts in three dogs (18.6%). Liver histopathology findings were similar for all dogs, regardless of outcome. CONCLUSIONS: Cellophane banding is an efficacious method for complete gradual occlusion of single extrahepatic shunts when the shunt vessel is attenuated to < or = 3 mm. Transcolonic portal scintigraphy is a reliable method for assessment of shunt attenuation and, unlike serum bile acids, is not influenced by other causes of liver dysfunction.  相似文献   

14.
Gradual occlusion of the splenic vein, using a specialized device (ameroid constrictor), was evaluated experimentally in three normal beagle dogs. Splenoportograms were used to verify that total occlusion of the splenic vein had occurred in all dogs within 4 to 5 weeks after application of the device. The ameroid constrictor (AC) was also evaluated as a method of gradual vascular occlusion in 12 dogs and two cats with single, extrahepatic, portosystemic shunts (PSS). Serum bile acid (SBA) concentrations were measured and portal scintigraphy (PS) was performed on all 14 animals preoperatively and 10, 20, 30, and 60 days postoperatively. Two dogs (14%) died from portal hypertension in the early postoperative period. One dog and one cat developed multiple acquired PSS, confirmed by mesenteric portography 90 days after the operation. Portal scintigraphy confirmed total occlusion of the primary shunt in the other 10 animals. Shunt fractions (SF), as measured by PS on postoperative days 30 and 60, declined significantly from preoperative values. Significant decreases were noted between preoperative and postoperative values for preprandial SBA on postoperative day 60 and for postprandial SBA on postoperative day 30. SBA concentrations did not correlate with SF. Based on this study, gradual vascular occlusion using the AC is recommended as a method for treatment of single, extrahepatic, PSS.  相似文献   

15.
OBJECTIVE: To evaluate outcomes after attenuation of extrahepatic portosystemic shunts in dogs using surgical silk. DESIGN: Retrospective study. PROCEDURE: Case records were reviewed for degree of surgical attenuation, experience of the primary surgeon, perioperative mortality and problems related to persistent portosystemic shunting or shunt ligation. Presence of portosystemic shunting after surgery was evaluated by ammonia tolerance testing, measurement of postprandial serum bile acid, plasma urea and cholesterol concentrations and liver enzyme activity. The influence of age, postocclusion portal pressure, primary surgeon, degree of attenuation and postoperative biochemical findings on the occurrence of postoperative problems was assessed. RESULTS: The mortality rate was 2.1%. Shunt attenuation was complete in 34% and partial in 66% of dogs. Portal hypertension necessitating ligature removal was encountered in only one dog. Five dogs experienced neurological abnormalities (seizures or ataxia), possibly as a manifestation of 'postligation seizure syndrome'. Postoperative liver function was normal in 78% of dogs, including 70% with partial shunt attenuation. Experience of the surgeon was related positively to outcome after partial attenuation (P = 0.002). Postoperative biochemical evidence of abnormal liver function was the most sensitive predictor of recurrence of clinical signs referable to persistent portosystemic shunting. CONCLUSIONS: In the hands of an experienced surgeon, surgical attenuation of single extrahepatic shunts was safe and effective, even in animals with partial attenuation. Most dogs with biochemical evidence of persistent shunting suffer relapse of clinical signs within 18 months of surgery. Postligation neurological syndromes of variable intensity may be more common than previously thought.  相似文献   

16.
Computed tomography angiography, sonography, scintigraphy, and portography can be used to evaluate the portal vasculature to evaluate for a portosystemic shunt (PSS). Time‐of‐flight magnetic resonance angiography (TOF‐MRA) and contrast‐enhanced MRA (CE‐MRA) are other potentially useful techniques. The aim of this study was to evaluate CE‐MRA in 10 dogs suspected of having a PSS. Noncontrast MR images of the abdomen were obtained using a Siemens Symphony MR‐scanner (1.5 T) and a T1‐weighted FLASH‐3D sequence with a very short scan time (about 20 s). After injection of contrast medium, the initial sequence was repeated five times. The sequence with the best contrast medium filling of the portal vasculature was selected subjectively, subtracted from the initial survey image series, and a maximum intensity projection (MIP) of the subtraction data, in multiple views, was created. The cross‐sectional and MIP images were evaluated for abnormal portosystemic vasculature. A single PSS was identified and confirmed at surgery in all dogs. A portocaval shunt was found in five dogs, a portophrenic shunt in three dogs, a portoazygos shunt in one, and a central divisional intrahepatic shunt in one other dog. Based on our results, CE‐MRA is a useful tool for imaging abdominal and portal vasculature and for the diagnosis of a PSS.  相似文献   

17.
Doppler ultrasonography was used to evaluate the portal vein in 14 dogs before, immediately after and four weeks after a partial ligation of a congenital extrahepatic portocaval shunt. By four weeks after the operation, the hepatofugal or zero flow in the portal vein segment cranial to the shunt origin had become a hepatopetal flow in 13 of the dogs, which became clinically healthy. The other dog continued to have a hepatofugal flow in the portal vein cranial to the origin of the shunt and continued to show clinical signs of hepatic encephalopathy. The shunt remained functional in six of the dogs, and three of them developed portosystemic collaterals in addition. In the other eight dogs the patent shunt was non-functional, because a hepatopetal flow was detected in the shunt adjacent to the portal vein. This flow was the result of the splenic vein entering the shunt, and the splenic blood dividing; some flowed via the shunt towards the portal vein, preventing the portal blood from shunting, and the rest flowed via the attenuated shunt segment to the caudal vena cava. Shunting of the splenic venous blood was clinically insignificant.  相似文献   

18.
Two dogs had right divisional intrahepatic portacaval shunts within the right lateral lobe of the liver. In both dogs, an extrahepatic portacaval vascular anastomosis was created, using an autologous right external jugular vein graft. The intrahepatic shunts were completely attenuated using a prehepatic intravascular caval approach. The creation of the vascular graft allowed postattenuation rises in portal pressure to be controlled, preventing the development of life threatening portal hypertension. Both dogs recovered from the procedure. One dog is clinically normal and does not require medication (8 months postoperatively); the other dog was euthanatized 5 months after surgery because of renal failure. Scintigraphy studies, performed before surgery, showed significant shunting of portal blood away from the liver (shunt indices 65% and 59%), whereas, similar studies done 4 weeks afterwards showed almost normal portal blood flow (shunt indices 16% and 18%, respectively).  相似文献   

19.
Ultrasonographic diagnosis of congenital portosystemic shunt in 14 cats   总被引:2,自引:0,他引:2  
Twenty-four cats with clinical and, or, clinico-pathological signs compatible with portosystemic shunting were examined prospectively using two-dimensional grey-scale, duplex and colourflow Doppler ultrasonography. Diagnosis of congenital portosystemic shunt was subsequently confirmed in 14 cats using operative mesenteric portography and surgery. Of the 14 affected cats, nine were purebred; eight were male and six female. The mean age at the time of diagnosis was nine months (range four to 27 months). Ultrasonographic evidence of a small liver was present in seven cats (50 per cent); visibility of intrahepatic portal vessels was reduced in three (21 per cent). An anomalous blood vessel was identified ultrasonographically in each cat; in 10 cats (71 per cent) the vessel was observed to originate from the portal vein and drain into the caudal vena cava. Abnormally variable portal blood flow waspresent in eight of the 10 cats in which it was measured. At surgery, six shunts were intrahepatic and eight extrahepatic; the ultrasonographic diagnosis of intra- versus extra-hepatic shunt was correct in 13 cats (93 per cent). No anomalous blood vessels or abnormalities affecting the portal vein were detected ultrasonographically in any of the 10 cats that did not have congenital portosystemic shunting. Hence, the accuracy of ultrasonography for diagnosis of congenital portosystemic shunting in this series was 100 per cent.  相似文献   

20.
A Miniature Dachshund, 3-month-old, 3.1 kg, was diagnosed as an intrahepatic portosystemic shunt (PSS) with the shunting vessel in 6-mm diameter. Percutaneous transvenous coil embolization (PTCE) was performed with a stainless steel coil in 8-mm diameter. Intraoperative portal pressure elevated about 2.5 times after one-stage coil occlusion. Two weeks after the PTCE, serum bile acid levels reduced within the normal range. The portogram showed complete occlusion of the shunting vessel 4 months after the PTCE. Approximately 3 years after the PTCE, the patient has shown no clinical signs. PTCE could be performed more easily and less invasively in a small-breed dog. It is therefore suggested that PTCE is a promising therapeutic technique in canine intrahepatic PSS.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司    京ICP备09084417号-23

京公网安备 11010802026262号