首页 | 官方网站   微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 359 毫秒
1.
In the last few years, the allergenic potential of latex has been receiving greater attention. While latex allergies have been widely reported in the literature, the prevalence and severity have rapidly increased in the last few years. The role of rubber in the prevention of HIV infection has played a part in recognizing the allergenic potential, as with increased emphasis on infection control in the dental office has come an increase in complaints of adverse reactions to surgical gloves. A review of the literature reveals latex allergy problems to be not confined to gloves, but to articles of clothing, rubber dam material, and other latex-containing materials. Life-threatening cases have been reported. Little information in the literature concerns the extent of the problem among dental personnel. The dental professional may be faced with not only discomfort for the dental staff, but also compromising reactive possibilities in certain patients. There is a need for development of alternative protective products for the dental office, since elimination of barrier protection is not a viable alternative to infection control.  相似文献   

2.
The purpose of this article is to educate the dental hygienist about the seriousness of latex allergy and provide background information necessary for treating the latex allergic patient, including basic information on immunology, hypersensitivity reactions, latex, and natural rubber latex. Symptoms of latex allergy, types of reactions, and methods of exposure are discussed. Methods for achieving a minimal latex environment are presented, along with information to treat the patient with latex allergy, which can affect health, career, future, and lifestyle. Because the number of latex-allergic individuals increases daily, a thorough understanding of its diagnosis and implications is necessary for all oral health care workers.  相似文献   

3.
Increasingly, patients with rubber latex allergy are being seen in dental offices. Health care workers, persons allergic to certain foods and those with certain medical histories are potentially latex-sensitive. This article presents the case of a patient with a history of severe rubber latex allergy and the associated management of an endodontically involved tooth. The possibility of the latex allergic patient being sensitive to gutta-percha obturation material is also raised.  相似文献   

4.
Allergic reactions during or after dental examination are uncommon. However, such reactions may be serious and distressing. Allergy to local anaesthetics and dental materials may be considered, but reactions to rubber in gloves worn by the dentist should be remembered. Two patients are reported who experienced symptoms following contact with rubber gloves worn by their dentists, with skin tests subsequently showing an allergic reaction to glove constituents, and in one case latex. With the increasing use of rubber gloves by dental and medical personnel, reactions in sensitised patients are likely to become more common. In patients with a history of symptoms related to dental work, it is important to remember delayed and immediate reactions to rubber.  相似文献   

5.
Both health care workers and spina bifida patients are at risk to develop type I latex allergy since allergenic proteins of natural rubber latex are present in a variety of latex products. Natural latex contains more than 250 polypeptides and approximately 60 of them show IgE-binding characteristics. A multitude of these latex allergens has been identified, and their sensitization potency for both risk groups has been determined. While hevein (Hev b 6.02) is the major allergen in latex-allergic health care workers, 80% of latex sensitized-spina bifida children have IgE antibodies to the "rubber elongation factor" (Hev b 1). Almost all relevant latex allergens have been identified in natural latex products: however, no data on the allergen profiles of individual latex products exist. The knowledge of the major latex allergens enables improved diagnosis and to monitor the success of prevention strategies for decreasing the high prevalence of latex allergies.  相似文献   

6.
The use of latex gloves in the health care setting dates back to the 1800s, when these products were introduced as a means of preventing the passage of microorganisms to operating room patients. Today, fear of human immunodeficiency virus transmission and other blood-borne diseases has led to implementation of standardized guidelines for glove use for health care professionals. Because of the unique combination of strength, flexibility, and elasticity of natural rubber, latex is typically the material of choice for a variety of medical products, including examination gloves. Unfortunately, routine use of latex in the health care setting may be detrimental to patients and caregivers with a history of natural rubber latex hypersensitivity reactions.  相似文献   

7.
Lack of knowledge concerning latex allergy may lead to a life-threatening adverse reaction to natural rubber latex. Registered nurses need a latex allergy knowledge base to provide latex-safe health care to clients and to create a latex-safe environment. This research explored the current knowledge base of registered nurses as related to (1) the care of clients at risk for latex allergy, or diagnosed with latex allergy, and (2) the provision of a latex-safe environment for all populations. This article describes this research and its implications for nurses. A copy of the Latex Allergy Knowledge Base Self-Assessment Questionnaire is included at the conclusion of the article.  相似文献   

8.
It is axiomatic to state that if products made of natural rubber latex were not used in health care settings then there would be no problems of acquired hypersensitivity from such products. Although synthetic materials are available they do not currently possess the same technical qualities of elasticity and comfort, nor do they deliver the desired degree of protection against biological agents as gloves made out of natural rubber latex. Selection of gloves either for non-sterile procedures or sterile surgical use should be based on this understanding, and gloves with minimal levels of extractable latex proteins should be used.  相似文献   

9.
1. The increased use of natural rubber latex barrier protection to prevent exposure to bloodborne pathogens has led to an increase in latex related health reactions, particularly associated with glove use. 2. The three types of reactions to latex in order of frequency include irritant contact dermatitis, allergic contact dermatitis, and immediate systemic/anaphylaxis reactions. 3. The management goal for all reactions is to avoid unnecessary restriction from the appropriate use of latex (gloves) which provides the best barrier protection, while protecting individual workers from exposure that results in sensitization or causes sensitized individuals to have serious reactions. 4. Choose non-latex gloves when barrier protection from bloodborne pathogens is not an issue. When selecting a latex glove, choose a glove that is low in proteins and powder free to control airborne latex exposure.  相似文献   

10.
With the increase in infectious disease epidemics and the need to protect health-care workers, the use of rubber gloves has increased twofold. Recent reports have noted an increase also in the prevalence of natural rubber latex allergy among some of these workers. A newly emerging problem, the allergy has potentially life-threatening consequences for those affected, a fact which has far-reaching ramifications for all those working in contact with latex, critical care nurses in particular. Indeed, the allergy has had a major impact on one such nurse, to the extent that she has had to relinquish her career and make significant changes to her lifestyle. Latex allergy was first recognised in 1927 but has become more prevalent in the last few years. There are two types of reactions, type I and type IV, with symptoms varying from a mild itch to anaphylaxis. Diagnosis is made via a blood or skin test, as well as a patient history. Treatment is to medicate for symptoms, while avoidance is the only way to prevent occurrences. The case study which follows reveals the impact that this allergy can have on a critical care nurse.  相似文献   

11.
消解氨溶-火焰原子吸收光谱法测定胶乳中钠   总被引:1,自引:0,他引:1       下载免费PDF全文
用消解氨溶法处理胶乳样品 ,即先用浓硝酸消解样品 ,再用氨水溶解消解产物 ,建立了在氨性溶液中快速测定胶乳中钠的FAAS法。以硝酸钾溶液作为消电离剂 ,用工作曲线法测定。对样品处理方法、消解产物的溶解性质、线性范围、干扰及检出限进行了考察。测定结果的相对标准偏差 1.7% ,加标回收率 97.3 %~ 10 2.3 %。方法简便、快速、准确。  相似文献   

12.
Immediate hypersensitivity reactions ranging from mild urticaria to life threatening anaphylaxis after exposure to natural rubber latex have been reported frequently in health care workers while occupational asthma due to latex exposure is less well studied. The results of specific challenge tests and immunological tests in four health care workers with work related respiratory and skin disorders induced by the use of latex gloves are described. Occupational asthma was confirmed in three subjects by specific challenge tests. All had a positive skin test reaction to the latex extract; specific IgE antibodies were detected in only one subject. The fourth subject had a negative specific inhalation and skin test reaction to the latex extract. Peak expiratory flow monitoring at work and away from work showed a pattern consistent with work related asthma. These findings confirm that latex is a cause of occupational asthma in health care workers.  相似文献   

13.
Greater application of universal precautions has increased practitioner exposure to chemicals present in personal protective equipment. Of prime concern is the latex present in examination and surgical gloves. A survey concerning latex exposure, allergies, and handwashing was administered to three advanced classes of dental students and was sent to 300 private practitioners in Central Indiana. Results indicate that adverse skin reactions to latex start while in dental school. Problems due to latex gloves were reported by 18.6 percent of the students. Student handwashing materials and methods were adequate, except for inadequate washing time. Adverse skin reactions were reported by 24.1 percent of practitioners wearing latex gloves. Two handwashing problems were noted--inadequate washing time and the common use of water instead of an antimicrobial soap after glove removal. Both students and practitioners reported relatively high levels of personal and family histories of allergy to a variety of sources.  相似文献   

14.
Natural latex from the rubber tree Hevea brasiliensis is an allergen in persons with significant cumulative latex exposure, such as those in the health care and rubber industries, as well as those undergoing repeated surgeries, especially if they undergo surgeries early in life. Symptoms of latex allergy may progress rapidly and unpredictably to anaphylaxis. The prevalence of latex allergy has increased as the use of rubber gloves in health care settings has increased. Airborne latex particles that adhere to the cornstarch used to powder gloves are a significant cause of respiratory symptoms and a source of sensitization. Once an individual has become sensitized, he or she may experience allergic symptoms when exposed to any product containing latex. Diagnosis is made initially by the history. Latex-specific IgE testing and skin prick testing may confirm the suspicion. The most effective strategy in the treatment of latex allergy is avoidance; however, there is a large group of sensitized people who have not been identified and who do not recognize that their symptoms are caused by latex allergy. Physicians caring for latex-sensitive persons must act as their advocates in building awareness of the problem and developing protocols for their safe care. Latex-sensitized persons should be educated about the latex content of common objects.  相似文献   

15.
In May 1993, the US Food and Drug Administration (FDA) granted product approval for the first female condom made of polyurethane. It provides some protection against sexually transmitted diseases (STDs), but the data are limited on the effectiveness of the Reality Vaginal Pouch against STDs. Female condom users have a relatively high pregnancy rate. FDA requires the label for Reality to stress that latex condoms for men are most effective against STDs and HIV/AIDS. Men who are sensitive to rubber can use condoms made of sheep intestine or cecum (brand names: Fourex and Lambskin). These nonrubber male condoms prevent pregnancy, but do not prevent HIV transmission. A specialist in contact dermatitis suggests that rubber sensitive men use a nonrubber condom directly over the penis and then cover that condom with a rubber condom to protect against HIV transmission. A nonlatex thermoplastic elastomer has been used to make male condoms since the early 1990s, but FDA has yet to approve it. A recent article suggests that a thermoplastic elastomer may be the only choice for rubber sensitive males. FDA approval will increase the availability of a nonlatex thermoplastic elastomer condom. The contact dermatitis specialist reviews and follows up on other articles he has written over the last 20 years. Topics include ethylene oxide burns in hospitalized patients, paraben paradox, benzocaine as a contaminant in sunscreens containing glyceryl PABA, sensitivity to nickel, misuse of a patch test to detect hypersensitivity to mercury amalgam dental fillings, permanent destruction of the fingernails due to an allergic reaction to an acrylic nail preparation, and dermatitis due to visual display units.  相似文献   

16.
BACKGROUND: Endotoxin is an inflammatory made by gram negative bacteria that can irritate the skin, induce respiratory problems, fever, and shock. It is an adjuvant for both delayed hypersensitivity and IgE production and has been shown to magnify antigen specific mediator release. Since many of the clinical problems associated with natural latex products involve similar clinical sequelae, we investigated the possibility that latex gloves might be contaminated with endotoxin. OBJECTIVE: To measure the endotoxin content of a variety of natural latex gloves, investigate the its distribution and origin, associated with latex proteins, and determine the particle sizes associated with its release. METHODS: Endotoxin, protein, and allergen were measured using a quantitative kinetic Limulus assay, modified Lowry, and RAST inhibition, respectively. Particle size and density were determined using an Anderson multistage air sampler and CsCl2 gradient. RESULTS: Endotoxin was found to be a highly significant contaminant of some latex gloves. Levels ranged from 0.09 ng to 2.8 micrograms/g of glove. Protein levels ranged from < 25 to 1150 micrograms/g of glove while allergen levels ranged from < 1 to 837 micrograms/g of glove. Endotoxin and protein eluted rapidly from the interior of the gloves tested. Greater than 70% of the endotoxin was found to be associated with particles in the < 7 microns aerodynamic diameter range. The highest levels of endotoxin were found in nonsterile examination gloves with a tendency towards powdered gloves containing more endotoxin and protein. A slurry containing cross-linked dextran through which gloves were dipped revealed very high endotoxin contamination (64 micrograms/mL) while unused cross-linked dextran has very little associated endotoxin. CONCLUSIONS: These data demonstrate that some natural rubber latex gloves, particularly nonsterile examination gloves, are contaminated with high amounts of endotoxin and proteins. These were found mostly on the inside of gloves and were released as very small respirable particles that were not physically associated with the powder. These findings support the hypothesis that endotoxin may be responsible for some of the tissue irritation associated with latex glove use. In addition, this material may be responsible for the enhancement of delayed and immediate hypersensitivity reactions to chemicals and proteins found in these products and offers a possible explanation for the disproportionate severity of these reactions.  相似文献   

17.
消解乳化-火焰原子吸收光谱法测定胶乳中镁和锌   总被引:7,自引:0,他引:7       下载免费PDF全文
用消解 乳化法处理胶乳样品 ,即先用浓硝酸消解样品 ,以乙醇 甲基异丁基酮混合溶剂溶解消解产物 ,然后用乳化剂Tween -80乳化成乳浊液。建立了快速测定胶乳中镁、锌的FAAS法。以工作曲线法测定。对样品处理方法、消解产物的溶解性质、乳化剂的选择、试液与空白溶液粘度的一致性、线性范围、干扰及检出限进行了考察。测定结果与灰化法一致 ,相对标准偏差小于 3.2 % ,镁、锌的加标回收率分别为 95.85 %~ 10 0 .0 %和 99.0 %~ 10 3. 0 %。方法简便  相似文献   

18.
The prevalence and severity of latex allergy has increased dramatically in the last 15 years due to exposure to natural rubber products. Although historically this health risk has been elevated in hospital personnel and patients, a recent survey has indicated a significant potential risk for the general population. To obtain a wide-spread source for latex exposure, we have considered tire debris. We have searched for the presence of latex allergens in passenger car and truck tire tread, in debris deposited from the atmosphere near a freeway, and in airborne particulate matter samples representative of the entire year 1993 at two sites in the Los Angeles basin (California). After extraction of the samples with phosphate buffered saline, a modified-ELISA inhibition assay was used to measure relative allergen potency and Western blot analyses were used to identify latex allergens. The inhibition studies with the human IgE latex assay revealed inhibition by the tire tread source samples and ambient freeway dust, as well as by control latex sap and latex glove extracts. Levels of extractable latex allergen per unit of protein extracted were about two orders of magnitude lower for tire tread as compared to latex gloves. Western blot analyses using binding of human IgE from latex-sensitive patients showed a band at 34-36 kDa in all tire and ambient samples. Long Beach and Los Angeles, California, air samples showed four additional bands between 50 and 135 kDa. Alternative Western blot analyses using rabbit IgG raised against latex proteins showed a broad band at 30-50 kDa in all samples, with additional bands in the urban air samples similar to the IgE results. A latex cross-reactive material was identified in mountain cedar. In conclusion, the latex allergens or latex cross-reactive material present in sedimented and airborne particulate material, derived from tire debris, and generated by heavy urban vehicle traffic could be important factors in producing latex allergy and asthma symptoms associated with air pollution particles.  相似文献   

19.
Lanthanidecompoundsbegantobeusedasplasticstabilizerinthe 1 980s[1] .Sincethen ,rareearth (RE)compoundshavebeenlargelyappliedinRE containingpolymerbasedcomposite .Anumberofplasticandrubberitemswithbettermechanicalpropertiesweredeveloped ,aswellasnewtypesofpolym…  相似文献   

20.
SM Tarlo 《Canadian Metallurgical Quarterly》1998,44(8):80-8; discussion 81-3
Immediate hypersensitivity responses to natural rubber latex (NRL) products have been recognized with increasing frequency in North America since 1989. The allergic response occurs to one or more NRL proteins, resulting in contact urticaria, angioedema, allergic rhinitis, asthma, or anaphylaxis. Early recognition of sensitization to NRL is crucial to prevent the occurrence of life-threatening reactions in sensitized healthcare providers and their patients.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司    京ICP备09084417号-23

京公网安备 11010802026262号