首页 | 官方网站   微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
2.
Accurate exposure assessments are needed to evaluate health hazards caused by airborne microorganisms and require air samplers that efficiently capture representative samples. This highlights the need for samplers with well-defined performance characteristics. While generic aerosol performance measurements are fundamental to evaluate/compare samplers, the added complexity caused by the diversity of microorganisms, especially in combination with cultivation-based analysis methods, may render such measurements inadequate to assess suitability for bioaerosols. Specific performance measurements that take into account the end-to-end sampling process, targeted bioaerosol and analysis method could help guide selection of air samplers.

Nine different samplers (impactors/impingers/cyclones/ electrostatic precipitators/filtration samplers) were subjected to comparative performance testing in this work. Their end-to-end cultivation-based biological sampling efficiencies (BSEs) and PCR-/microscopy-based physical sampling efficiencies (PSEs) relative to a reference sampler (BioSampler) were determined for gram-negative and gram-positive vegetative bacteria, bacterial spores, and viruses.

Significant differences were revealed among the samplers and shown to depend on the bioaerosol's stress–sensitivity and particle size. Samplers employing dry collection had lower BSEs for stress-sensitive bioaerosols than wet collection methods, while nonfilter-based samplers showed reduced PSEs for 1 μm compared to 4 μm bioaerosols. Several samplers were shown to underestimate bioaerosol concentration levels relative to the BioSampler due to having lower sampling efficiencies, although they generally obtained samples that were more concentrated due to having higher concentration factors.

Our work may help increase user awareness about important performance criteria for bioaerosol sampling, which could contribute to methodological harmonization/standardization and result in more reliable exposure assessments for airborne pathogens and other bioaerosols of interest.

Copyright 2014 American Association for Aerosol Research  相似文献   


3.
Four N-donors (PHDA, ATPH, APHO, and MTAN) containing NH2 were used to extract Hg(II), Cd(II), and Pb(II). Their extraction capacity was determined by measurement of percentage extraction.

The chelates extract these metals differently: for example, efficiency of ATPH was the highest for Hg(II) compared to PHDA, APHO, and MTAN.

The extraction efficiency was found to depend on: donor atom hardness, chelate total hardness, metal: chelate mole ratio and substituent’s electronic effects. Among all, total hardness and chelate stability are key factors and molecule of small (EHOMOELUMO) is more reactive, where extraction efficiency increases as molecular stability decreases.  相似文献   


4.
Polycyclic aromatic hydrocarbons (PAHs) are relatively well-known organic pollutants and due to their carcinogenic and mutagenic properties their presence in the environment still attracts a lot of attention.

According to literature reports and own research, PAHs presence in wastewaters is common. It was confirmed that PAHs are the components of municipal landfill leachate. Membrane techniques are one of the most interesting ways of removing PAHs from leachate.

The purpose of this article is to monitor PAHs concentration changes during the membrane (reverse osmosis - RO) leachate treatment processes. In the first stage of testing leachates were filtrated on the sand bed (pre-filtration). After the pre-filtration they were directed to the membrane module for the main filtration.

Sixteen PAHs listed by EPA were analyzed. The results with information on PAHs concentration in leachate samples were presented using HPLC with fluorescence detection (FLD). The changes in PAHs concentration were determined in leachate samples before and after pre-filtration as well as after RO. The decrease of PAHs concentration in the samples was observed after these processes. The total concentration of 16 PAHs in raw municipal landfill leachates amounted to 23.64–26.95 μg/L. The research confirmed the high efficiency in removal of PAHs while using a reverse osmosis (59–72%). Including the pre-filtration, the overall level of removed PAHs reached 81–86%. The average PAHs concentration after pre-filtration and RO was in the 4.46–4.99 μg/L range. The municipal landfill leachate with a high concentration of PAHs should be cleaned before it is discharged into the environment.  相似文献   


5.
In this paper, two waste solvent technologies are presented as alternatives to the disposal of spent acetone-water mixtures.

In the first alternative, a batch rectifier is used to concentrate the waste in order to obtain a distillate with a higher calorific value, which is then sent to off-site incineration either in a cement kiln or in a conventional waste solvent incinerator. The second alternative is a hybrid process composed by a batch rectifier and a pervaporation unit that processes in batchwise mode the first cut from the distillation task to obtain a dehydrated solvent. Here, four scenarios are considered, comprising two kinds of membrane materials and two different vacuum systems.

For each alternative, the conceptual design was carried out with the aid of conceptual models of the unit operations involved. Quasi-optimal values for design and operation variables were used as input data to perform an economical and an environmental assessment of each alternative. The economic analysis suggests that the hybrid process is the best alternative given that the replacement cost of fresh solvent (about 850 U$S/ton) is considered as a credit value.

From the environmental analysis with life cycle assessment, two main conclusions can be drawn: i) the use of the distillate as an alternative fuel in a cement kiln leads to a reduction in emissions that is relevant for the categories related to human health and ecosystem quality; and ii) in terms of resource depletion, the hybrid process distillation/pervaporation with the ceramic membrane HybSi (Pervatech) shows the lowest impact due to the solvent recovery.  相似文献   


6.
Aim: This study aimed to evaluate the effects on microleakage of the application of ozone gas, laser and traditional cavity disinfection under in vitro conditions.

Material and Methods: Ninety third-molar teeth extracted for various reasons were used in this study. All the teeth were prepared with a standard V cavity on the buccal surface. Then the teeth were randomly allocated to one of 6 groups of 15 teeth; Group 1 benzalkonium chloride, Group 2 chlorhexidine gluconate, Group 3 sodium hypochloride, Group 4 diode laser, Group 5 ozone gas, Group 6 control group- no disinfection was applied. Primer was applied to the cavities, then bond and 10-s polymerization. Clearfil AP-X was used in the cavities as a hybrid composite and polymerized for 20 s. The samples then underwent 1000 thermal cycles of 30-s application, in baths at temperatures between 5 ± 2 °C and 55 ± 2 °C. All the samples were stirred in 0.5% basic phuxine solution and the sections taken under stereomicroscope were examined and photographed at 15 × magnification. SEM analysis was made and the obtained results were statistically evaluated with the Kruskal–Wallis test.

Results: No significant difference was seen between the groups in respect of the microleakage values of both the occlusal and gingival edges (p < 0.05). Comparison of the microleakage values of the occlusal and gingival edges of the groups determined the least leakage to be in the ozone group (p < 0.05).

Conclusion: No statistical significance was determined between the groups. However, the mean least microleakage was found in the ozone group and the highest amount in the control group.  相似文献   


7.
Many well-established models can be applied to calculate the filtration efficiencies. In these models the filtration velocity and challenging particle size are assumed to be known accurately. However, in realistic filtration tests, the filtration velocity has profiles dependent on the filter holder geometry and experimental conditions; the challenging particles have size distributions dependent on the instruments and operation conditions. These factors can potentially affect the measured filtration efficiency and lead to discrepancies with the models.

This study aims to develop an integrative model to predict the filtration efficiencies in realistic tests by incorporating the effects of the filtration velocity profile and challenging particle size distribution classified by a differential mobility analyzer (DMA) into the existing filtration models. Face velocity profile is modeled with fluid mechanics simulations; the initial generated particle size distribution, the particle charging status and the DMA transfer function are modeled to obtain the challenging particle size distribution. These results are then fed into the filtration models. Simulated results are compared with experimental ones to verify the model accuracy. This model can be used to reduce filtration test artifacts and to improve the experimental procedure.

The results reveal that the face velocity upstream the filter exhibits high degree of homogeneity not affecting the filtration efficiency if the filter pressure drop is not very low. The generated particle size distribution and the DMA selection size window could influence the challenging particle size distribution and therefore the measured filtration efficiency.

Copyright © 2017 American Association for Aerosol Research  相似文献   


8.
Ozone treatment for preventing the biofouling in cooling water systems is investigated.

In the fresh water system, the separating effect of the ozonated water on the microorganisms such as the sphaerotilus and the zoogloea which adhere to the piping and form the slime is recognized. When the ozonated water is supplied intermittently to the piping without stopping the flow of the cooling water, a constant volume of cooling water can be maintained. At the velocity of 1 m/sec, the amount of metal corrosion produced by the ozonated water is reduced on the mild steel, increased on the copper and does not change on the cast iron, when compared with that produced by the water containing no ozone.

In the seawater system, since many substances are oxidized by the ozone, the same treatment as that in the fresh water system cannot be applied. However, if the seawater in the cooling system can be replaced with ozone-containing air intermittently once a week, the adhesion of organisms such as barnacles and mussels to the piping can be prevented without having a bad influence on the other living oceanic organisms.  相似文献   


9.
Objectives: To investigate the effect of different self-etch adhesive systems application techniques: active or passive in a single or double layer on adhesive–dentin microshear bond strength.

Methods: Occlusal surfaces of 48 extracted human molars were ground to expose flat superficial dentin surfaces. Specimens were randomly divided into two main groups according to the tested self-etch adhesive system either: One-step self-etch (AdperTM easy-one) or two-step self-etch (AdperTM SE Plus). Each adhesive system was applied on the prepared dentin surfaces followed one of these techniques: (1) Passive application of a single layer, (2) Active application of single layer, (3) Passive application of double adhesive layer (with light curing in between), and (4) Active application of double adhesive layers. Resin composite was packed inside micro-tubes fixed on the bonded dentin surfaces and light cured for 40 s. All specimens were stored in artificial saliva either for 24 h or 3 months before testing. Microshear bond strength test was employed using a universal testing machine at a crosshead speed of 0.5 mm/min.

Results: AdperTM SE Plus showed higher significant microshear bond strength in compared with AdperTM easy-one. For both adhesive systems active application showed higher significant microshear bond strength to dentin than passive application. Double application of adhesive systems showed lower microshear bond strength than single application.

Conclusion: Active application of self-etch adhesives could improve the dentin microshear bond strength. Double application with curing in between the layers did not improve the bond strength to the tested adhesive.  相似文献   


10.
Objectives: The aim of this in vitro study was to evaluate the effect of different desensitizers’ application on the microleakage of previously restored Class V composite resin restorations.

Materials and methods: Class V cavities were prepared on the buccal surfaces of 40 extracted human third molars. Forty box-shaped cavities were divided into four groups, based on the desensitizers used (n = 10). All teeth were restored with the same bonding agent and composite material. No desensitizer was applied in the control group. In the experimental groups, BisBlock, Gluma and Universal bonding agents were the desensitizers. The desensitizers were applied after completion of composite restorations according to manufacturers’ instructions. All specimens were then thermocycled at 5–55 °C, with a 10-s dwell time for 500 cycles. The samples were then immersed in 0.5% methylene blue dye for 24 h, sectioned into two equal halves, evaluated for microleakage using a stereomicroscope at 30× magnification and scored on a scale of 0–3. The data were analysed using the Kruskal–Wallis test at the significance level p < 0.05.

Results: There were no significant differences in microleakage after desensitizer application (p > 0.05). However, based on the obtained numerical values in our study, while the BisBlock and bonding groups showed lower microleakage at the occlusal margin, BisBlock, Gluma and bonding group showed lower microleakage at the gingival margin compared to the control group.

Conclusions: The application of desensitizers as a post-treatment option could be considered an advisable procedure to minimize microleakage.  相似文献   


11.
Purpose: To investigate the effects of phosphoric acid esters (PAEs)-containing primers on the micro-tensile bond strengths (MTBS) of etched enamel, the micro-morphologies of the resin–enamel interfaces, and the enamel surfaces.

Materials and Methods: Thirty-three bovine incisors were used in this study. After the labial enamel surfaces were highly polished, they were etched, water sprayed, and air-dried. Afterward, the enamel surfaces were treated with or without (control) one of three PAEs-containing primers (40%MDP, Ivoclar Vivadent; Resulcin AquaPrime A + B, DMG; Xeno V, Dentsply), water sprayed, and air-dried. Subsequently, an adhesive Heliobond (Ivoclar Vivadent) was applied and resin composite (Core Build-up, Bisco) was placed incrementally. They were prepared into multiple beams of about 1 × 1 × 8 mm for MTBS tests. The enamel surfaces and resin–enamel interfaces were analyzed by SEM and TEM. The data were analyzed by two-way ANOVA and LSD test.

Results: Using PAEs-containing primers could increase the enamel MTBS (p < 0.05). The primer MDP produced higher MTBS than the primer Resulcin AquaPrime A + B and Xeno V. The SEM findings revealed the primed enamel surfaces were covered with a thin or glue-like layer of monomer-calcium salts of PAEs and the residual enamel crystallites, and various micro-porosities were detected within the hybrid layers. The TEM findings revealed the hydroxyapatite crystallites were tightly covered by the adhesive, the adhesive mixed with resin composite, or sparse irregular enamel crystallites.

Conclusion: The application of PAEs-containing primers on the etched enamel substrate could significantly increase the immediate enamel bond strengths. However, this effect was dependent on the individual PAEs-containing primer used.  相似文献   


12.
We describe a new method for focusing and concentrating a stream of moving micron-sized aerosol particles in air. The focusing and concentrating process is carried out by the combined drag force and optical force that is generated by a double-layer co-axial nozzle and a focused doughnut-shaped hollow laser beam, respectively. This method should supply a new tool for aerosol science and related research.

Copyright © 2018 American Association for Aerosol Research  相似文献   


13.
Objective: The aim of the present study was to assess the influence of an in vitro aging regime (NaOCl storage) on dentine microtensile bond strength (μTBS) of five one-step one-bottle self-etch adhesives in comparison with bond strength of two-step self-etch adhesive.

Material and methods: Flattened dentine surfaces from 30 bovine incisors were bonded with five one-step one-bottle self-etch adhesives (iBond, Clearfil S3 Bond, AdheSE One F, G-Bond, Optibond all-in-one) and one two-step self-etching adhesive (Clearfil SE Bond). Composite buildups were done with microhybrid resin composite. Bonded samples were sectioned into resin–dentine sticks of 0.8 mm2 cross section. Randomly selected 20 sticks were tested directly by microtensile bond strength testing machine, whereas another randomly selected 20 sticks were tested after being stored in solution of 10% NaOCl for 5 h. Data were analyzed by two-way analysis of variance (ANOVA) and Tukey’s honest significant difference (HSD) tests (p < 0.05).

Results: All adhesives exhibited similar dentine bond strength with exception of G-Bond. After NaOCl storage, μTBS reduced in all groups significantly. The lowest μTBS were found for G-Bond. Rest of one-step self-etch adhesives presented similar μTBS with two-step self-etch adhesive.

Conclusion: Interfaces of resin–dentine bonding are susceptible to NaOCl degradation. The amount of the destruction depends on adhesive system. NaOCl degradation of the nonresin encapsulated collagen fibers might decrease long-term stability of resin bonding with dentine.  相似文献   


14.
Primary biological aerosol particles (PBAP) such as pollen and fungal spores can induce allergenic responses and affect health in general. Conditions such as allergic rhinitis (hay fever) and asthma have been related to pollen concentrations. Likewise some pollen have been shown to induce ice nucleation and cloud condensation at higher temperatures than those associated with some chemical species, thereby affecting planet Earth's albedo and overall radiative balance. Hence, the near real-time (on-line) monitoring of airborne pollen and other PBAP using a variety of spectroscopic and light scattering techniques represents an area of growing development and consequence.

In this study, two separate field campaigns (one at a rural site in Ireland and the other at an urbanized location in Germany) were performed to detect and quantify pollen releases using a novel on-line fluorescence spectrometer (WIBS-4). The results were compared with results obtained using more traditional Hirst-type impactors. Size, “shape,” and fluorescence characteristics of ambient particles were used to determine the concentrations and identity of the PBAP likely to be pollen grains.

The concentration results obtained for both methodologies at both the Irish and German sites correlated very well, with R 2 values >0.9 determined for both campaigns. Furthermore, the sizing data available from the WIBS-4 approach employed in Ireland indicated that pollen grains can be identified in appropriate conditions. WIBS-4 measurements of Yew pollen both in the laboratory and at the rural site indicated almost identical size ranges of 25 to 27 μm. Yew pollen is generally reported to be in this range, but the measurements reported here are the first of their type providing data on the size of in-flight Yew pollen.

Copyright 2014 American Association for Aerosol Research  相似文献   


15.
Cleanable dust filter media are typically used in huge baghouse filter apparatuses. Thereby, the regeneration by back-pulsing from the clean gas side is done by either time-controlled or pressure-controlled operation, whereas the latter is more common. Hence, the need for a detailed knowledge of the clogging and filtration mechanisms during long time operation of a pressure-controlled filter aging arises.

A mathematical model describing the pressure drop evolution during time-controlled filter aging has been developed. The core of the developed model is the concept of dust masses that distribute themselves on a specific particle deposition area inside and on the surface of the filter medium. By altering this particle deposition area, various clogging mechanisms, occurring during an aging procedure, are covered by the model.

In this work, the model was adapted and coefficient parameters adjusted for pressure-controlled filter regeneration operation. A multitude of pressure-controlled test runs were performed in a specially designed filtration apparatus. From these tests, process-specific parameters were regressed and used to model the respective pressure drop curves. These model pressure drop curves show good accordance both quantitatively and qualitatively to experimental data and give a detail view on different clogging mechanisms.  相似文献   


16.
Pure starch has been isolated from different samples: oak acorn, sorghum, and potato using alkali steep and wet-milling procedure. The structure of the extracted starches was analyzed using Fourier transform infrared (FT-IR) spectroscopy and X-ray diffraction. Their physicochemical properties (water content, ash content, pH, amylose content, swelling power, and water solubility index) were determined. The FT-IR spectra of isolated native starches have shown the main bands characterizing the starch. For sorghum starch (SS) and oak acorn starch (OAS), X-ray diffractograms exhibited an A-type diffraction pattern, while potato starch (PS) displayed typical B-type pattern. Compared to sorghum and oak acorn, potato starch has shown the highest level of both swelling power and water solubility index.

To estimate the color removal quality of the extracted starches, a sorption of a dye named maxilon red GRL has been carried onto them.

The results of equilibrium isotherms in batch adsorption process were analyzed according to the Langmuir and Freundlich model. The characteristic parameters were determined for each model. Furthermore, the effect of initial pH and ionic strength on adsorption capacity was considered, and regeneration studies were carried out.  相似文献   


17.
It is currently admitted that for each filtration process using pleated filters, at least three steps can be distinguished: depth and surface filtration, which are common to flat filters, and surface reduction. This step is caused by inefficient filling of the pleat due to the filter geometry. For combustion aerosol, it has been proved that this third step strongly depends on the filtration velocity resulting in an increase of the resistance when air flow decreases. This observation leads one to think that Brownian diffusion, higher for low velocities, could influence the clogging dynamic of a pleated filter.

In this article, a protocol derived from the dust cake preparation method published by Schmidt is developed. The aim of this study is to measure the aerosol penetration inside a filter media as well as in a pleat using a scanning electronic microscope and energy dispersive X-ray spectroscopy elementary detection. This method has also been extended to the study of pleated filters to measure the particle distribution inside the pleat. Filters were loaded with nanoparticles in order to evaluate the specificity of the diffusional regime on the clogging of pleated HEPA filters. For pleated filters, two filtration velocities were investigated: 2.5 and 0.2 cm/s.

Copyright 2014 American Association for Aerosol Research  相似文献   


18.
In four groups of patients with chronic conditions receiving an ozone application (intravascular administration of ozone/oxygen mixtures with or without autohemotherapy), the immunoglobulins IgA, IgG and IgM were determined in serum; in groups 1 and 2, lysozyme and vitamin A values also were measured. The groups were broken down as follows:

Group 1: 19 patients with carcinoma of the cervix. Group 2: 20 patients with carcinoma of the ovaries. Group 3: patients with chronic conditions (80% patients with rheumatoid arthritis), shortterm study (34 patients). Group 4: patients with chronic conditions (80% patients with rheumatoid arthritis), long–term study (47 patients). A further breakdown into statistical categories in groups 1 and 2 showed no significant changes in the immunoglobulins examined, including the vitamin A and lysozyme values.

A short-term influence in group 3 became evident through a significant increase in immunoglobulin G, whereas no significant decrease was observed in all immunoglobulins in group 4. An immunosuppressive effect of the ozone applied could not be detected in any of the 4 groups.  相似文献   


19.
Separating a mixture of CO2 and H2S into two products through distillation is both difficult and complicated because of similar relative volatility between the two gasses, particularly when a CO2 concentration exceeds 80%. Therefore, the separation process can involve many separating stages. However, adding a solvent (agent) to the distillation column during the separation process makes this procedure easier.

In this study, different solvents (ethylbenzene, o-xylene, m-xylene, and toluene) and operating conditions (temperature, pressure, and reflux ratio) for separating CO2 from H2S have been simulated through distillation using Aspen HYSYS software. Furthermore, four different aromatic compounds (solvents) for different concentrations (from 0 to 40 mol%) have been evaluated to increase the CO2/H2S relative volatility, reducing the quantity of the solvent required and energy consumption.

m-xylene was found to be the best solvent for separating CO2 from H2S because of the significant effect on relative volatility, the low quantity required for high CO2 recovery, and the low energy for generating the solvent.  相似文献   


20.
Accurate refractive index values are required to determine the effects of aerosol particles on direct radiative forcing. Theoretical retrievals using extinction data alone or extinction plus absorption data have been simulated to determine the sensitivity of each retrieval. A range of aerosol types with a range of different refractive indices were considered. The simulations showed that the extinction-only retrieval was not able to accurately or precisely retrieve refractive index values, even for purely scattering compounds, but the addition of a simulated absorption measurement greatly improved the retrieval.

Copyright 2014 American Association for Aerosol Research  相似文献   


设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司    京ICP备09084417号-23

京公网安备 11010802026262号