首页 | 官方网站   微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
A selective, rapid and simple liquid chromatography-tandem mass spectrometry (LC-MS/MS) method is described for assay of donepezil in human plasma using escitalopram as an internal standard. Chromatographic separation was achieved on a Betabasic-C(8), 5 microm, 100 x 4.6 mm column using methanol:water:formic acid (90:9.97:0.03, v/v/v) as mobile phase. Detection of donepezil and internal standard was achieved by ESI MS/MS in positive ion mode using 380.20/91.10 and 325.13/262.00 transitions, respectively. The linearity over the concentration range of 0.15-50 ng/mL for donepezil was obtained and the lower limit of quantification was 0.15 ng/mL. For each level of quality control samples, inter-day and intra-day precisions (RSD) were < or =8.92 and 10.35% and accuracy (%RE) were < or =7.33% and 9.33%, respectively. The recovery was more than 88.50% for both donepezil and internal standard by solid-phase extraction, eliminating evaporation and reconstitution steps.  相似文献   

2.
Crizotinib is a small molecule inhibitor of anaplastic lymphoma kinase (ALK) and can be used to treat ALK‐positive nonsmall‐cell lung cancer. A rapid and simple high‐performance liquid chromatography–tandem mass spectrometry (LC‐MS/MS) method was developed and validated for the quantification of crizotinib in rat plasma using a chemical synthetic compound buspirone as the internal standard (IS). The plasma samples were pretreated by a simple protein precipitation with methanol–acetonitrile (1:1, v/v). Chromatographic separation was successfully achieved on an Agilent Zorbax XDB C18 column (2.1 × 50 mm, 3.5 µm). The gradient elution system was composed of 0.1% formic acid aqueous solution and 0.1% formic acid in methanol solution. The flow rate was set at 0.50 mL/min. The multiple reaction monitoring was based on the transitions of m/z = 450.3 → 177.1 for crizotinib and 386.2 → 122.2 for buspirone (IS). The assay was successfully validated to demonstrate the selectivity, matrix effect, linearity, lower limit of quantification, accuracy, precision, recovery and stability according to the international guidelines. The lower limit of quantification was 1.00 ng/mL in 50 μL of rat plasma. This LC‐MS/MS assay was successfully applied to the quantification and pharmacokinetic study of crizotinib in rats after intravenous and oral administration of crizotinib. The oral absolute bioavailability of crizotinib in rats was 68.6 ± 9.63%. Copyright © 2015 John Wiley & Sons, Ltd.  相似文献   

3.
Huang Y 《色谱》2011,29(10):962-966
建立了饲料中维吉尼霉素M1的超高效液相色谱-串联质谱(UPLC-MS/MS)分析测定方法。样品用乙腈-0.2%(v/v)甲酸水溶液(8:2, v/v)超声提取两遍后,通过UPLC-MS/MS进行分析,以BEH C18色谱柱为分析柱,乙腈-0.3%(v/v)甲酸水溶液(35:65, v/v)为流动相,采用电喷雾电离正离子模式,以多反应监测模式进行定性和定量分析。在0.3~226.6 μg/L范围内线性关系良好(相关系数r=0.9995)。维吉尼霉素M1的检出限和定量限分别为2 μg/kg和7 μg/kg,平均回收率为82.6%~102.7%,相对标准偏差为0.9%~10.5%。结果表明,该方法具有操作简单、准确度和灵敏度高、重现性好的特点,适合用于检测饲料中维吉尼霉素M1的含量。  相似文献   

4.
Boldine is a potential anti‐inflammatory agent found in several different plants. Published bioanalytical methods using HPLC with ultraviolet and fluorescent detection lacked enough sensitivity and required tedious sample preparation procedures. Herein, we describe the development of a novel ultra‐high performance LC with MS/MS for determination of boldine in plasma. Boldine in plasma was recovered by liquid–liquid extraction using 1 mL of methyl tert‐butyl ether. Chromatographic separation was performed on a C18 column at 45°C, with a gradient elution consisting of acetonitrile and water containing 0.1% (v/v) formic acid at a flow rate of 0.3 mL/min. The detection was performed on an electrospray triple‐quadrupole MS/MS by positive ion multiple reaction monitoring mode. Good linearity (r2 > 0.9926) was achieved in a concentration range of 2.555–2555 ng/mL with a lower limit of quantification of 2.555 ng/mL for boldine. The intra‐ and inter‐day precisions of the assay were 1.2–6.0 and 1.8–7.4% relative standard deviation with an accuracy of ?6.0–8.0% relative error. This newly developed method was successfully applied to a single low‐dose pharmacokinetic study in rats and was demonstrated to be simpler and more sensitive than the published methods, allowing boldine quantification in reduced plasma volume. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

5.
This study describes the development of a rapid and sensitive high‐performance liquid chromatography–electrospray ionization tandem mass spectrometry (LC‐MS/MS) assay for the quantification of [6]‐gingerol in mouse plasma and application to a pharmacokinetic study after dose ranging in mice. The assay involved a protein precipitation step with acetonitrile and an isocratic elution using a mobile phase consisting of acetonitrile and water containing 0.1% formic acid (80:20 v/v). The multiple reaction monitoring was based on the transition of m/z = 277.2 → 177.1 for [6]‐gingerol and 294.2 → 137.1 for nonivamide (internal standard). The assay was validated to demonstrate the specificity, linearity, recovery, accuracy, precision and stability. The calibration curves were linear over the wide concentration range of 10–10,000 ng/mL (r ≥ 0.9988). The lower limit of quantification was 10 ng/mL using a small volume of mouse plasma (20 μL). The method was successfully applied to a pharmacokinetic study in mice after intravenous injection of [6]‐gingerol at 1.5, 3 and 6 mg/kg doses. The pharmacokinetics of [6]‐gingerol were linear over the dose range studied as demonstrated by the linear increase in area under the concentration‐time curve (AUCinf) with no significant change in the systemic clearance (Cls), volume of distribution (Vss) and elimination half‐life (t1/2) as a function of dose. Copyright © 2011 John Wiley & Sons, Ltd.  相似文献   

6.
Trigonelline is a pyridine alkaloid found in fenugreek seeds and coffee beans. Most of the previous studies are concerned with the quantification of trigonelline along with other constituents in coffee herbs or beverages. Only a few have focused on its determination in animal or human tissues by applying different modes of HPLC with UV or MS detection. The aim of the study was to develop and validate a fast and simple method for trigonelline determination in serum by the use of hydrophilic interaction liquid chromatography (HILIC) with ESI‐MS/MS detection. Separation of trigonelline was achieved on a Kinetex HILIC column operated at 35°C with acetonitrile–ammonium formate (10 mm , pH = 3) buffer mixture (55:45, v/v) as the mobile phase. The developed method was successfully applied to determine trigonelline concentration in mouse serum after intravenous administration of 10 mg/kg. The developed assay is sensitive (limit of detection = 1.5 ng/mL, limit of quantification = 5.0 ng/mL) and linear in a concentration range from 5.0 to 250.0 ng/mL. Sample preparation is limited to deproteinization, centrifugation and filtration. The application of the HILIC mode of chromatography with MS detection and selection of deuterated trigonelline as internal standard allowed a rapid and precise method of trigonelline quantification to be to developed.  相似文献   

7.
A simple, rapid, sensitive and specific liquid chromatography-tandem mass spectrometry method was developed and validated for quantification of tamsulosin (I), a highly selective alpha1-adrenoceptor antagonist used for the treatment of patients with symptomatic benign prostatic hyperplasia. The analyte and internal standard, mosapride (II) were extracted by liquid-liquid extraction with diethyl ether-dichloromethane (70:30, v/v) using a Glas-Col Multi-Pulse Vortexer. The chromatographic separation was performed on a reverse phase Waters symmetry C18 column with a mobile phase of 0.03% formic acid-acetonitrile (30:70, v/v). The protonated analyte was quantitated in positive ionization by multiple reaction monitoring with a mass spectrometer. The mass transitions m/z 409.1 solidus in circle 228.1 and m/z 422.3 solidus in circle 198.3 were used to measure I and II, respectively. The assay exhibited a linear dynamic range of 0.1-50.0 ng/mL for tamsulosin in human plasma. The lower limit of quantitation was 100 pg/mL with a relative standard deviation of less than 10%. Acceptable precision and accuracy were obtained for concentrations over the standard curve ranges. A run time of 2.0 min for each sample made it possible to analyze a throughput of more than 400 human plasma samples per day. The validated method has been successfully used to analyze human plasma samples for application in pharmacokinetic, bioavailability or bioequivalence studies.  相似文献   

8.
A rapid, sensitive and specific high-performance liquid chromatography/electrospray ionization mass spectrometric (LC-ESI-MS) method was developed and validated for the quantification of madecassoside, a major active constituent of Centella asiatica (L.) Urb. herbs, in rat plasma. With paeoniflorin as an internal standard (IS), a simple liquid-liquid extraction process was employed for the plasma sample preparation. Chromatographic separation was achieved within 6 min on a Shim-pack CLC-ODS column using acetonitrile and water (60:40, v/v) containing 0.1% (v/v) formic acid as the mobile phase. The detection was performed by MS with electrospray ionization interface in negative selected ion monitoring (SIM) mode. The linear range was 11-5500 ng/mL with the square regression coefficient (r(2) ) of 0.9995. The lower limit of quantification was 11 ng/mL. The intra- and inter- day precision ranged from 4.99 to 9.03%, and the accuracy was between 95.82 and 111.80%. The average recoveries of madecassoside and IS from spiked plasma samples were >92%. The developed method was successfully applied to the pharmacokinetic study of madecassoside in rats after an oral administration.  相似文献   

9.
高效液相色谱-串联质谱法检测牛奶中头孢洛宁残留   总被引:3,自引:0,他引:3  
李帅鹏  郭春娜  孟蕾  黄显会 《色谱》2014,32(5):519-523
建立了牛奶中头孢洛宁残留检测的高效液相色谱-串联质谱方法。1 g牛奶经乙腈沉淀蛋白质后,上清液于37 ℃水浴下氮气吹干,用1 mL甲醇-0.1%甲酸水溶液(3:7,v/v)复溶,正己烷除脂净化后检测。流动相为乙腈和0.1%甲酸水溶液,梯度洗脱,经C18色谱柱分离,采用多反应监测正离子模式对头孢洛宁进行定性定量分析。采用基质匹配法对牛奶中头孢洛宁的含量进行标准校正,在2~200 μg/L范围内,头孢洛宁质量浓度与其对应峰面积的线性关系良好,相关系数>0.999。牛奶中加标样品的检出限(按S/N≥3计)为0.5 μg/kg,定量限(S/N≥10计)为2 μg/kg。在定量限、1/2最高残留限量、最高残留限量、2倍最高残留限量添加水平下,牛奶中头孢洛宁的平均回收率为78.5%~86.2%,日内相对标准偏差为1.5%~6.2%,日间相对标准偏差为2.9%~5.6%。该方法可用于牛奶中头孢洛宁的残留检测。  相似文献   

10.
《Analytical letters》2012,45(7):1381-1391
Abstract

A rapid, sensitive, and specific liquid chromatography‐electrospray ionization mass spectrometric (LC‐ESI‐MS) method has been developed for quantification of gliclazide in human plasma. The analyte and tolbutamide (internal standard, I.S.) were extracted from plasma samples with n‐hexane–dichloromethane (1:1, v/v) and analyzed on a C18 column. The chromatographic separation was achieved within 4.0 min by using methanol–0.5% formic acid (80:20, v/v) as mobile phase and the flow rate was 1.0 mL/min. Ion signals m/z 324.0 and 271.0 for gliclazide and internal standard were measured in the positive mode, respectively. The method was linear within the range of 2.5–2000 ng/mL. The lower limit of quantification (LLOQ) was 2.5 ng/mL. The intra‐ and inter‐day precisions were lower than 2.8% in terms of relative standard deviation (RSD). The inter‐day relative error (RE) as determined from quality control samples (QCs) ranged from ?1.93% to 1.85%. This validated method was successfully applied for the evaluation of pharmacokinetic profiles of gliclazide modified‐release tablets in 20 healthy volunteers.  相似文献   

11.
A sensitive and convenient high-performance liquid chromatography-tandem mass spectrometry(HPLC-MS/MS) assay is described for the (5-HT(lB/lD)) receptor agonist sumatriptan in human plasma. Sumatriptan was recovered from plasma (81.8 +/- 6.8%) by liquid-liquid extraction. The mobile phase flow rate was 0.3 mL/min and consisted of methanol:water:formic acid (90:10:0.1, v/v/v). The analytical column (4.6 x 100 mm) was packed with Partisil C(8) (5 micro m). The standard curve was linear from 0.7 to 70.4 ng/mL (r(2) > 0.99). The lower limit of quantitation was 0.7 ng/mL. The assay was specific, accurate (percentage deviation from nominal concentrations were <15%), precise and reproducible (within- and between-day coefficients of variation <10.3%). Sumatriptan in plasma was stable over three freeze/thaw cycles and at room temperature for one day. The utility of the assay was demonstrated by following sumatriptan plasma concentrations in two healthy subjects for 8-12 h following a single 20 mg intranasal dose.  相似文献   

12.
Cucurbitacin B (CuB), one of the most abundant forms of cucurbitacins, is a promising natural anticancer drug candidate. Although the anticancer activity of CuB has been well demonstrated, information regarding the pharmacokinetics is limited. A rapid, selective and sensitive UPLC‐MS/MS for CuB was developed and validated using hemslecin A (HeA) as internal standard (IS). Plasma samples were pre‐treated by liquid–liquid extraction with dichloromethane. Separation was achieved on a reversed‐phase C18 column (50 × 4.6 mm, 5 µm) at 35°C using isocratic elution with water–methanol (25:75, v/v) at a flow rate of 0.3 mL/min. The analytes were monitored by a triple quadrupole tandem mass spectrometer with positive electrospray ionization mode. The calibration curve was linear (r > 0.995) in a concentration range of 0.3–100 ng/mL with a limit of quantification of 0.3 ng/mL. Intra‐ and inter‐day accuracy and precision were validated by percentage relative error and relative standard deviation, respectively, which were both lower than the limit of 15%. This assay was successfully applied to a pharmacokinetic study of CuB in Wistar rats. Copyright © 2015 John Wiley & Sons, Ltd.  相似文献   

13.
A simple, robust and specific liquid chromatography tandem mass spectrometry (LC‐MS/MS) method was developed and validated to determine the concentration of corticosterone (Cort) which is usually regarded as a stress biomarker in mouse serum. Since Cort is an endogenous hormone, a ‘surrogate analyte’ strategy was adopted using the stable isotope‐deuterated corticosterone as a surrogate of the authentic analyte to generate the calibration curve. With telmisartan as the internal standard, the analytes were extracted with methanol, ethanol and acetone (1:1:1, v/v/v) and separated on a XTerra C18 (2.1 × 50 mm, 3.5 µm) column using a mobile phase consisting of 0.2% formic acid in water–methanol (30:70, v/v). Detection was performed in multiple reaction monitoring mode with an electrospray ionization source operated in positive ion mode. The standard curves were linear (r2 > 0.999) over the dynamic range of 8.60–430 ng/mL, with a lower limit of quantification of 8.60 ng/mL. The intra‐ and inter‐assay precisions were less than 15.0% of the relative standard deviation. This method was further used for analysis of serum samples from C57B/L tumor‐bearing mice before and after the treatment of fluoxetine. Validation of the assay and its application to the analysis demonstrated that the method was applicable to determine meaningful changes in Cort concentrations in serum samples of the tumor‐bearing mice for the stress status evaluation. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

14.
A simple, sensitive, and rapid method for determination of L‐trantinterol in rat plasma was developed for the first time by using LC coupled to MS/MS based on chiral stationary phase. A baseline separation of the enantiomers of trantinterol was achieved on a Chirobiotic V column, using a mixture of acetonitrile–methanol–ammonia–acetic acid (80:20:0.01:0.02, v/v/v/v) as the mobile phase. The detection was performed on a triple‐quadrupole tandem mass spectrometer by multiple reaction monitoring mode via ESI. The calibration curve was linear in concentration range from 0.270 to 108 ng/mL in plasma with the lower limit of quantification of 0.270 ng/mL. The intra‐ and interday precision (relative standard deviation) values were within 10.9% and the accuracy (relative error) was from 2.6 to 9.2% at all quality control levels. The method has been successfully applied to a study of L‐trantinterol pharmacokinetics in rats.  相似文献   

15.
朱峰 《色谱》2015,33(1):68-74
建立了快速测定纺织助剂中双(氢化牛脂基)二甲基季铵化合物(DHTDMAC)的超高效液相色谱-串联质谱(UPLC-MS/MS)分析方法.样品经5%(v/v)甲酸甲醇超声波提取、稀释后,采用Eclipse Plus C18柱(50 mm×2.1 mm, 1.8 μm)分离,甲醇和0.1%(v/v)甲酸水溶液为流动相梯度洗脱,电喷雾离子源正离子多反应监测模式进行定性和定量分析.实验结果表明,DHTDMAC在10~280 μg/L范围内与峰面积呈良好的线性关系,相关系数(r2)为0.9991;以不低于3倍信噪比计算方法检出限(LOD, S/N=3)为3 mg/kg;方法定量限(LOQ, S/N=10)为10 mg/kg.3种纺织助剂基质中DHTDMAC在3个不同加标水平的平均回收率为97.2%~108.3%,相对标准偏差(RSD)为1.5%~4.6%.该方法灵敏度高、操作简便、快速准确,适用于纺织助剂中DHTDMAC的分析测定.  相似文献   

16.
A sensitive, rapid and selective ultra‐performance liquid chromatography–tandem mass spectrometric (UPLC‐MS/MS) method was developed for the determination and pharmacokinetic study of domperidone in human plasma. Diphenhydramine was used as the internal standard. Plasma sample pretreatment involved a one‐step liquid–liquid extraction with a mixture of diethyl ether–dichloromethane (3:2, v/v). The analysis was carried out on an Acquity UPLCTM BEH C18 column. The mobile phase consisted of methanol–water containing 10 mmol/L ammonium acetate and 0.5% (v/v) formic acid (60:40, v/v). The detection was performed on a triple quadrupole tandem mass spectrometer in multiple reaction monitoring mode via electrospray ionizationsource with positive mode. Each plasma sample was chromatographed within 2.1 min. The standard curves for domperidone were linear (r2 ≥ 0.99) over the concentration range of 0.030–31.5 ng/mL with a lower limit of quantification of 0.030 ng/mL. The intra‐ and inter‐day precision (relative standard deviation) values were not higher than 13% and accuracy (relative error) was from ?7.6 to 1.2% at three quality control levels. The method herein described was superior to previous methods and was successfully applied to the pharmacokinetic study of domperidone in healthy Chinese volunteers after oral administration. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

17.
A rapid, selective and sensitive method using UPLC‐MS/MS was first developed and validated for quantitative analysis of koumine in rat plasma. A one‐step protein precipitation with methanol was employed as a sample preparation technique. Plasma samples were separated on an Acquity UPLC BEH C18 column (50 × 2.1 mm, i.d. 1.7 µm) with a gradient mobile phase consisting of methanol with 0.1% (v/v) formic acid and water containing 0.1% (v/v) formic acid at a flow rate of 0.3 mL/min. Detection and quantification were performed on a triple quadrupole tandem mass spectrometer by multiple reaction monitoring mode via positive eletrospray ionization. Good linearity (r > 0.9997) was achieved using weighted (1/x2) least squares linear regression over a concentration range of 0.025–15 µg/mL with a lower limit of quantification of 0.025 µg/mL for koumine. The intra‐ and inter‐ precisions (relative standard deviation) of the assay at all three quality control samples were 5.6–14.1% with an accuracy (relative error) of 5.0–14.0%, which meets the requirements of the US Food and Drug Administration guidance. This developed method was successfully applied to an in vivo pharmacokinetic study in rats after a single intravenous dose of 20 mg/kg koumine. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

18.
A simple, sensitive and specific ultra‐performance liquid chromatography–tandem mass spectrometry (UPLC‐MS/MS) method was developed and validated to determine the concentrations of 7‐hydroxymitragynine in rat plasma. Following a single‐step liquid–liquid extraction of plasma samples using chloroform, 7‐hydroxymitragynine and the internal standard (tryptoline) were separated on an Acquity UPLCTM BEH C18 (1.7 µm, 2.1 × 50 mm) column using an isocratic elution at a flow rate of 0.2 mL/min. The mobile phase consisted of 0.1% acetic acid in water and 0.1% acetic acid in acetonitrile (10:90, v/v). The run time was 2.5 min. The analysis was carried out under the multiple reaction‐monitoring mode using positive electrospray ionization. Protonated ions [M + H]+ and their respective product ions were monitored at the following transitions: 415 → 190 for 7‐hydroxymitragynine and 173 → 144 for the internal standard. The calibration curve was linear over the range of 10–4000 ng/mL (r2 = 0.999) with a lower limit of quantification of 10 ng/mL. The extraction recoveries ranged from 62.0 to 67.3% at concentrations of 20, 600 and 3200 ng/mL). Intra‐ and inter‐day assay precisions (relative standard deviation) were <15% and the accuracy was within 96.5–104.0%. This validated method was successfully applied to quantify 7‐hydroxymitragynine in rat plasma following intravenous administration. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

19.
A rapid, simple, selective and sensitive LC‐MS/MS method was developed for the determination of curculigoside in rat plasma. The analytical procedure involves extraction of curculigoside and syringin (internal standard, IS) from rat plasma with a one‐step extraction method by protein precipitation. The chromatographic resolution was performed on an Agilent XDB‐C18 column (4.6 × 50 mm, 5 µm) using an isocratic mobile phase of methanol with 0.1% formic acid and H2O with 0.1% formic acid (45:55, v/v) at a flow rate of 0.35 mL/min with a total run time of 2.0 min. The assay was achieved under the multiple‐reaction monitoring mode using positive electrospray ionization. Method validation was performed according to US Food and Drug Administration guidelines and the results met the acceptance criteria. The calibration curve was linear over 4.00–4000 ng/mL (R = 0.9984) for curculigoside with a lower limit of quantification of 4.00 ng/mL in rat plasma. The intra‐ and inter‐day precisions and accuracies were 3.5–4.6 and 0.7–9.1%, in rat plasma, respectively. The validated LC‐MS/MS method was successfully applied to a pharmacokinetic study of curculigoside in rats after a single intravenous and oral administration of 3.2 and 32 mg/kg. The absolute bioavailability of curculigoside after oral administration was 1.27%. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

20.
Methyl-3-quinoxaline-2-carboxylic acid (MQCA) is the last major remaining detectable metabolite of Olaquindox in animal tissue. A rapid, sensitive and specific ultra performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) method was developed for the detection and quantification of MQCA in fish tissue using deuterated quinoxaline-2-carboxylic acid (d(4)-QCA) as internal standard. Various parameters affecting sample preparation, LC separation and MS/MS detection were investigated, and the optimal conditions concerned were determined. Fish tissue samples were subject to hydrochloric acid hydrolysis followed by Oasis MAX solid-phase extraction clean-up; analysis was performed using UPLC coupled to electrospray MS/MS. The chromatographic separation was achieved in less than 5 min. The limit of detection and the limit of quantification were 0.1 and 0.25 ng/g, respectively. The average recoveries of MQCA, spiked at levels of 0.25-50.0 ng/g, were from 92.7 to 104.3%. The relative standard deviation values were <6%. The validated method was successfully applied to analyze 60 batch samples collected from the local market.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司    京ICP备09084417号-23

京公网安备 11010802026262号